Centrifuge Biosafety. Brian Petuch, CBSP, RBP. The Usual Photo and Story

Similar documents
CYGNUS CF VI BLOOD CENTRIFUGE OPERATORS MANUAL

LSU Inter-Institutional Biological and Recombinant DNA Safety Committee (IBRDSC)

GUIDANCE NOTE 3: SAFE USE OF EQUIPMENT

Physical Hazards -Recognition, Evaluation and Control

THE COMPACT CENTRIFUGE: OPERATOR 1

CR-1730R User s Manual

Biological Safety Cabinet Failure Response Procedure

THE UNIVERSITY OF NEWCASTLE - DISCIPLINE OF MEDICAL BIOCHEMISTRY

Reliability in Laboratory Centrifuges Since Operator s Manual. Models 614B, 614L, 614U/UL and 614V/VL Laboratory Centrifuge. Rev. 5.

Chapter 10: Laboratory Equipment

Biological Safety Cabinets or Fume Hoods Which one to use?

Packing Instructions Heraeus Primo R

OVATION 56 EGG INCUBATORS CLEANING / SERVICE GUIDE

PRO 2000i LOW LEVEL DEPOSITOR

Centrifuge STANDARD OPERATING PROCEDURE

Electric Honey Extractor

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

HARDWOOD INDUSTRY FACILITY & SAFETY INSPECTION CHECKLIST

Research Document Type: PROCEDURE. Effective Date: January 01,2015 Author Steven Hayes

Biological Safety Cabinets. Biological Safety Cabinets

Florida International University. Biosafety Cabinet Program

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

INSTRUCTION MANUAL. Instruction Manual High Throughput Homogenizer

Low-voltage motors SIMOTICS GP, SD, DP Safety instructions for SH

Centrifuge STANDARD OPERATING PROCEDURE

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

Centrifuge/Vortex for PCR plates CVP-2

In this issue of the Environmental Health and Safety (EHS) Listserv, December 15, 2011:

557X-558X Comfort Care & Cozy Comfort, Premier Recliner 567X-5680 XL Cozy Comfort & XL Cozy Comfort Swing-Arm, Premier Recliner

'' Stone Fireplace Model# SRFP41301 Instructions Manual

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

LABORATORY INSPECTION CHECKLIST

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

3-1/2 GALLON PARTS WASHER OPERATING INSTRUCTION AND PARTS MANUAL. Model # 4KTV9

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

Teflon Rotary Drum Pump

Owner s Manual. FMI BRANDS INC Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F

Hydraulic Crimping Head, PN 69069

Contents. Ultrawave baths are manufactured in the UK and conform to exacting international standards.

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

PERFORM Operating Document

4-GALLON MOBILE PARTS WASHER

INSTRUCTIONS AND PARTS LIST. Model 3A LORTONE Cyrus Way Mukilteo, WA (425)

ROTARY TUMBLER LORTONE INSTRUCTIONS AND PARTS LIST. Model 3-1.5B. Model 45C. Model 33B Cyrus Way Mukilteo, WA (425)

SuperKlean Washdown Products

451 Black Forest Road Hull, IA Ph: (712) Fax: (712) TS g/hr Turnkey Ozone Generation System

Owner s Manual. FMI BRANDS INC th Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F

METALÚRGICA SIEMSEN LTDA. INSTRUCTION MANUAL CENTRIFUGAL JUICER MODELS CS / CSE

Instructions for Use Spinal Punches IFU

SCIF SOP for BSL 2 samples on Aria3

REFRIGERATED PREP TABLES Installation, Operation and Maintenance Instructions

HydroFlux Welder Torch System T0-102 / T0-103

Commit 2 Clean TM/MC. Bloodborne Pathogens Awareness Program

Floor cleaning procedures for slip, trip and fall prevention

Safety Checklist When Using Your Hedgecutter

Hydraulic Crimping Head, PN

DUAL FUNCTION ROWING MACHINE SF-RW5612 USER MANUAL

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

Model CWA200 Owner s Manual

Operator s Manual. Model G17 Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Owner s Manual. FMI BRANDS INC th Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2A

MULTIWASH XL OPERATOR S MANUAL & PARTS LIST PFMW18. Save These Instructions

Operation Manual R205BV, R209BV

Part#: 26B113 HEAVY DUTY CAST IRON ROTARY DRUM PUMP

Oil and Water Retort Instruction Manual

INSTALLATION & MAINTENANCE

Bob White Systems. the Bucket Milker Manual - Cow

10 and 12 Meat Slicer MS250 & MS300 Operating Manual

46920 County Rd E Center, CO Phone: Fax: Pump Rebuild Report. Union/Flowserve 6x8 MQF, 7 stage

Cleaning and Sterilization for Instruments & Posts

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT

WorkSafe ACT. Safe Work Procedures. Updated: Thu, 11 Nov :39: Overview

Flexible Nasopharyngoscope. Operator Manual. Manufactured by Henke-Sass, Wolf Distributed by Anthony Products, Inc.

user manual Model #: BLZ-HOOD

ELSTON 52 CEILING FAN

One Operator Bottling.

ST. KITTS CEILING FAN

Rutgers Environmental Health and Safety (REHS)

CS150 OWNER S MANUAL DISCRIMINATOR METAL DETECTOR

Cleaning the internal optics surfaces

Freezing of Water-Based Fire Protection Systems

COMMERCIAL COLD PRESS JUICER OWNER S MANUAL R MANUAL VERSION SERIAL #

DÉCOFIRE. Contemporary CHIMENEA. Assembly, Safety & Operating Instructions FOR OUTDOOR USE ONLY READ INSTRUCTIONS CAREFULLY BEFORE ASSEMBLY OR USE.

USER S MANUAL ATH WH220

OPERATOR'S MANUAL. IMPORTANT: READ OPERATOR'S MANUAL CAREFULLY Please fill out & return your warranty card! DP80405

V SERIES HDR GAS RANGES

CLS-1450 Series Spinner Flask Instruction Manual

FLECK 5600 WATER SOFTENER INSTALLATION

OPERATIONAL & INSTRUCTION MANUAL. Model: 2400FA (120v 1Ø) Model: 3200FA (220v-240V 1Ø) Voltage Supply to Machine:

Trouble Shooting and Help Guide TT / TTB 1840

Breezex (BX) Heavy Duty Reversible Supply/Exhaust Fans with Reversing Switch. IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

PARAGON FRYERS INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS MODEL: PF9 MODEL: PSF3 MODEL: PSPF9 MODEL: PDPF6 MODEL: PDPF9

OPERATION MANUAL. LED Coupling OM-TR355E. Please read this operation manual carefully and file for future reference.

EL400 OPERATION MANUAL

MAGNETIC ELLIPTICAL TRAINER SF-E3416 USER MANUAL

i-cube Microplate Incubator E10030

LAB SAFETY FOR CUSTODIANS

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Vibration Of Cooling Tower Fans. Barry T. Cease Cease Industrial Consulting Vibration Institute 2015

OPERATING AND MAINTENANCE MANUAL

Transcription:

Centrifuge Biosafety Brian Petuch, CBSP, RBP The Usual Photo and Story 1

INCIDENTS & OBSERVATIONS External Centrifuge Incidents Tufts University 2006 Botulinum toxin exposure Broken tube OSHA violation Emergency procedures Training PPE University Texas 2006 Genetic cross of H5N1 & H3N2 Cracked cap leaked fluid into rotor and bowl Centrifuge in open lab BSL-3 w/ respiratory PPE Postdoc placed on Tamiflu 2

Centrifuge is #1 Contaminated Instrument in rdna Lab Sampling for AdV5 strains in 5/8 Swiss labs showed significant contamination throughout the lab (Figure 1). (Guido Vogel, Biological and Chemical Safety Administration, Basel, Switzerland. ABSA Annual Meeting, October 2003) Information Courtesy of ThermoScientific CAUSES OF ROTOR FAILURES 3

Six Causes of Rotor Failure 1 Incorrect Loading or Balancing 2 Incorrect Attachment 3 Consumable Failure/Biocontainment 4 Overloading 5 Corrosion 6 Fatigue Preventing Incorrect Loading 1 Always run centrifuge with ALL buckets in place Always load buckets symmetrically Always balance adjacent and opposing loads within manufacturer s recommended tolerance 4

Ensuring Proper Attachment 2 Attachment to Centrifuge Superspeed rotors must be locked down to centrifuge drive by tightening the lock knob Low speed rotors must be fastened by locking pin General purpose, small benchtop, and micro-centrifuges must be fastened by locking nut or other mechanism as specified by manufacturer Always double check that your rotor is locked down before pressing start! Ensuring Proper Attachment 2 Swinging Bucket Rotors Buckets must be placed properly on the swinging arms Swinging bucket rotors must have all buckets in place Buckets should be cleaned and lubricated regularly to ensure a free swing out during the run For swinging bucket rotors, gently swing out each bucket to ensure a free easy motion. Always double check before pressing start 5

Ensuring Proper Attachment A Thermo plate carrier was used with a Beckman yoke. The clearance seemed OK, until the centrifuge accelerated. The metal components flexed enough to force the carrier off the swing pins, into the chamber armor. The centrifuge was destroyed, costing >$38,000. And a spill of pathogen occurred. Ensuring Proper Attachment Beckman Yoke Spacing 11.3 cm Thermo Yoke Spacing 10.5 cm A difference of +0.8 cm resulted in a destroyed centrifuge. DO NOT MIX COMPONENTS BETWEEN MANUFACTURES!!!! 6

Ensuring Proper Attachment 2 Swinging bucket rotor failed while spinning human blood. Bucket and trunnion chunk lifted the lid, spewing blood around the lab. Preventing Consumable Failure/ Biocontainment 3 Preventing Consumable Failure Ensure you are not exceeding the maximum rated speed by the manufacturer Ensure consumable is chemically compatible with your sample Make sure you have all the parts and use according to the directions Know the history of shared consumables Inspect before every use and do not use if signs of wear are apparent Implement replacement program consumables should be replaced regularly If in doubt contact manufacturer and verify proper use Biocontainment Biocontainment Certified* Lids for Swinging Buckets to enclose any kind of tubes Individual Biocontainment Certified* Tube Enclosures would provide double enclosure under the Biocontainment Certified Lids Biocontainment Certified* Rotor Lids for Fixed Angle Rotors *Biocontainment certification by CAMR in Porton Down, UK 7

Preventing Consumable Failure/ Biocontainment 3 Overfilling / Under filling Seal O-ring (if needed) d) must be present and in good condition Proper Tube Material & Chemical Resistance Polypropylene Polyethylene Polycarbonate Preventing Consumable Failure/ Biocontainment 3 O-ring (missing or damaged) 8

Preventing Overloading 4 All rotors are designed with a maximum load tolerance at the maximum speed If the maximum load is exceeded then the maximum speed MUST be derated ALWAYS check this in the manual and use the formula below. Ultraspeed swinging bucket rotors used for gradient work density of sample should be verified against speed and temperature to prevent point load failure Preventing Corrosion 5 Surface corrosion - caused by long term exposure to moisture or chemicals Stress corrosion - surface corrosion that is allowed to propagate until microcracks are formed deep into the structure of the rotor How to prevent surface corrosion: Clean rotors between every use Thoroughly dry rotors between uses Remove adapters between runs Never use metallic objects to open or remove parts Always use cleaning, disinfection and sterilization agents that are chemically compatible with the rotor If your application is corrosive consider an alternative rotor material such as carbon fiber! 9

Preventing Corrosion 5 Rotor used with improper tubes, closures and high salt solution Tubes are frozen into the rotor This rotor is a total loss! Preventing Fatigue Rotors are exposed to high g-forces and do wear out The molecular structure of the rotor changes as the metal elongates repeatedly eventually they will fail! Ultraspeed rotors have a recommended use and retirement span rated by the number of cycles or hours used Superspeed rotors are warranted for 10 years and should be considered d for retirement t even if they are in good condition All other rotors the guidelines vary and should be verified before use All rotors need to be retired even when they appear to be in good appearance metallic parts fatigue over repeated uses with no visible signs of wear 6 10

Preventing Fatigue 6 Have your rotors inspected regularly by a trained technician! Rotor instruction manuals must be available for users; they provide detailed information on operation, derating and use/care Log books are required for ultraspeed centrifuges! Log books are needed to meet manufacturer s warranty for high and low speed rotors Preventing Fatigue 6 This is the rotor manufacture date Picture dated 4/20/2017 11

Preventing Fatigue 6 This is the rotor manufacture date. According to table, the rotor was beyond useful life after 2008. Summary Be Smart, Be Proactive! Improve the life of your rotor and prevent damaging failures: Balance properly Attaching rotor and parts correctly Proactively managing consumable use Never overload Prevent corrosion with best lab practices Retire rotors Improve your lab experience by preventing messy spills or catastrophic accidents that cause potential exposures, significant repair costs, and loss of your precious samples! 12

RISK ASSESSMENT TOOLS Risk Assessment A. Bennett & S. Parks, Appl Micro 100 (2006) 658-663 13

Risk Assessment Risk Assessment 14

Risk Assessment Spray Factor, coupled with breathing rate and lab air changes can be used to estimate employee dose RESOURCES 15

Resources Manufacture s Instruction Manuals Rotor Logs for Derating Beckman Rotor Safety Guide Beckman Biosafe System Guide Eppendorf Aerosol-Tight Guide Thermo Rotor Care Guide ThermoLite Fiber Rotor Guide VWR Microcentrifugation Guide 16