CERTIFICATE of Product Conformity (QAL1 )

Similar documents
CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

Certificate: _02 / 9 September 2014

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 28 July 2016

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

Certificate: _01 / 29 April 2014

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: _03. V-CEM5100 for waste gas velocity. TÜV Rheinland Energy GmbH

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: ENDA-5000 with analysing module CMA-5800 for NOx. S0 2, CO, co2 and 02

CERTIFICATE of Product Conformity (QAL1)

Certificate: / 9 September 2014

Certificate: / 9 February 2011

Certificate: _01 / 2 February 2015

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: _02

Certificate: / 29 April 2014

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE. EN tested QAL 1 certified TUV approved Annual inspection. The certificate is valid until: 19July2017. Köln, 17 August2012

Certificate: _01 / 20 August 2013

CERTIFICATE of Product Conformity (QAL1 )

Certificate: _01 / 22 March 2013

Certificate: _02 / 22 March 2013

Certificate: _01 / 22 March 2013

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1 )

CONFIRMATION of Product Conformity (QAL1)

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE. about Product Conformity {QAL 1) Number of Certificate: _02

CERTIFICATE of Product Conformity (QAL1 )

CERTIFICATE of Product Conformity (QAL1 )

_03 / 28 July 2015

Certificate: / 29 April / /D1 of 07 July 2006 Addendum 936/ /C of 20 September 2013

Certificate: _01 / 19 August 2011

PRODUCT CONFORMITY CERTIFICATE

Certificate: / 29 April 2014

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE AR500 Open Path Monitor with ER120

PRODUCT CONFORMITY CERTIFICATE

PRODUCT CONFORMITY CERTIFICATE

Title: Standard Operating Procedure for Measurement of Total Hydrocarbon Using a Flame Ionization Detection

Complete Gas Analysis

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

Test reports for the determination of B 10d values for emergency stop switches of families 800F, 800H, 800T and D7 of Rockwell Automation

PRODUCT CONFORMITY CERTIFICATE

This SOP and the B.C. Field Sampling Manual are available at: www2.gov.bc.ca.

The licensee shall take the actions specified to close out the non-compliances and observations raised in this Site Visit Report.

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

HFID Heated Total Hydrocarbon Analyzer Module

EuroFID Gas Analyzers for Measurement of the Total Hydrocarbon Content

Proforma for Surveillance of Recognized Environmental Laboratory under the Environment (Protection) Act, 1986

Emissioni convogliate in atmosfera: Sistemi di monitoraggio in continuo delle emissioni SME

including the locations according to annex

Competency: Critically evaluate the function of the ionisation chamber in the Linear Accelerator and its importance for correct treatment delivery

Stand Alone DYNAGARD SP Operation Manual

Automation, Software und Informationstechnologie

CALIDUS tm the Modular micro Gas Chromatograph

International comparison of validation methods for dust concentration measurement

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

GMS800 FIDOR TOTAL HYDROCARBON ANALYZER CONTINUOUS MONITORING OF HYDROCARBON EMISSIONS

This document is a preview generated by EVS

continuous emissions monitoring Combustion & Environmental Monitoring

Thermo Scientific TVA2020 Introduction

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

PRODUCT CONFORMITY CERTIFICATE

Gas Detection - GD -

Flexible Schedule of Accreditation. SIRA CERTIFICATION SERVICE Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US.

ALTAIR 5X Multigas Detector Product Specification

FPD - Flame Photometric Detector

Series 9000 Total Hydrocarbon Analyzer

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

AS/NZS :2008

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

6915 Highway 225, Deer Park, TX 77536

SENSOR O2 O2-A

In accordance with the Radio Waves Act Chapter 58 Article 8(3), the document below is a

Rules for Classification and Construction Additional Rules and Guidelines

LET S PLAY IT SAFE. robecco secure center (RSC) G.A.S. inert control (RIC) dust control (RDC) silo automation (RSA)

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

METPOINT OCV. e. g. SAFE PROCESS THROUGH MONITORING. FOR CHALLENGING COMPRESSED-AIR APPLICATIONS Pharmaceuticals. Food Chemical Coating

Glenside Environmental Services Ltd

Transcription:

ATÜVF}heinland Precisely Right. CERTIFICATE of Product Conformity (QAL1 ) Certificate No.: 0000059868 AMs designation: Manufacturer: Test Laboratory: FIDAMAT 6 MEASURING SYSTEM fortoc SIEMENS AG Östliche Rheinbrückenstraße 50 76187 Karlsruhe German This is to certify that the AMS has been tested and ceriified according to the standards EN 15267-1: 2009, EN 15267-2: 2009, EN 15267-3: 2007 and EN 14181: 2015. Certification is awarded in respect of the conditions stated in this certificate (this certificate contains 6 pages). Suitability Tested EN 15267 QALI Certified Fiegular Surveillance www.tuv.com ld 0000059868 Publication in the German Federal Gazette (BAnz) of 17 July 2018 German Federal Environment Agency Dessau, 4 September 2018 /^,_:_f J /, Dr Marcel Langner Head of Section 114.1 www.umwelt-tuv.eu tre@umwelt-tuv.eu Phone: + 49 221806-5200 This ceriificate will expire on: 16 July 2023 Cologne, 3 September 2018 (/ Ü, # Ö, > ppa. Dr Peter Wi[bring Am Grauen Stein 51105 Köln Test institute accredited to EN ISO/lEC 17025:2005 by DAkks (German Accreditation Body). This accreditation is limited to the accreditation scope defined in the enclosure to the ceriificate D-PL-11120-02-00. all.de Pa e 1 of 6

Test Report: 936/21235670/A dated 12 December 2017 Initial certification: 17 July 2018 Expiry date: 16 July 2023 Publication: BAnz AT 17.07.2018 B9, chapter I number 3.1 Approved application The tested AMS is suitable for use at combustion plants according to Directive 2010/75/EU, chapter III (13 th BImSchV), the 30 th and 31 st BImSchV and TA Luft. The measured ranges have been selected so as to cater for as broad a field of application as possible. The suitability of the AMS for this application was assessed on the basis of a laboratory test and a three-months field test at a waste incineration plant. The AMS is approved for an ambient temperature range of +5 C to +40 C. The notification of suitability of the AMS, performance testing and the uncertainty calculation have been effected on the basis of the regulations applicable at the time of testing. As changes in legal provisions are possible, any potential user should ensure that this AMS is suitable for monitoring the limit values relevant to the application. Any potential user should ensure, in consultation with the manufacturer, that this AMS is suitable for the installation at which it will be installed. Basis of the certification This certification is based on: Test report 936/21235670/A dated 12 December 2017 issued by Suitability announced by the German Federal Environment Agency (UBA) as the relevant body The ongoing surveillance of the product and the manufacturing process qal1.de Page 2 of 6

Publication in the German Federal Gazette: BAnz AT 17.07.2018 B9, chapter I number 3.1, UBA announcement dated 3 July 2018: AMS designation: FIDAMAT 6 MEASURING SYSTEM for TOC Manufacturer: SIEMENS AG, Karlsruhe Field of application: For plants according to 13 th BImSchV, 30 th BImSchV, 31 st BImSchV and TA Luft Measuring ranges during performance testing: Component Certification range Supplementary measuring ranges Unit TOC 0 15 0 50 0 150 0 500 mg/m³ Software version: 1.3.6 Restriction: To operate this measuring system, an oxygen analyser is required at the same measurement point to compensate for cross-sensitivity. That oxygen analyser must be certified to EN 15267 and operated in accordance with EN 14181. Note: The maintenance interval is four weeks. Test Report:, Cologne Report no.: 936/21235670/A dated 12 December 2017 qal1.de Page 3 of 6

Certified product This certification applies to automated measurement systems conforming to the following description: The AMS FIDAMAT 6 MEASURING SYSTEM is a flame ionisation detector (FID). The conductivity of a hydrogen flame in which the sample gas is burned serves as a physical indicator. Sample gas is ionised in that flame. Ions thus released are collected and their number determined. The quantity of detected ions serves as an indicator for the number of organic carbon atoms present in the sample gas. The tested AMS consists of: FIDAMAT 6 analyser Analyser cabinet Heated sample probe (180 C) c/w controller, M&C SP2000 Heated line (180 C), max 50 m, c/w controller, inner liner made of Teflon Software version: 1.3.6 An integrated diaphragm pump supplies the sample gas to the FIDAMAT 6 measuring system via a heated line and an additional filter, and to the flame ionisation detector via a clogresistant quartz glass limiter. Inside the detector, hydrocarbons present in the sample gas are burned in an oxygen-hydrogen flame. Organic hydrocarbons are ionised during the combustion process. Ions thus released are converted into an ion current as a result of the polarisation potential between the electrodes and are measured with the help of a highly-sensitive amplifier. The measured current is proportional to the number of organic C atoms of the hydrocarbons present in the sample gas. A pressure controller keeps the hydrogen pressure at a constant level. A dove-tailed system consisting of a pump, capillaries and combustion-air pressure control ensures constant sample gas pressure. qal1.de Page 4 of 6

General remarks This certificate is based upon the equipment tested. The manufacturer is responsible for ensuring that on-going production complies with the requirements of the EN 15267. The manufacturer is required to maintain an approved quality management system controlling the manufacturing process for the certified product. Both the product and the quality management systems shall be subject to regular surveillance. If a product of the current production does not conform to the certified product, must be notified at the address given on page 1. A certification mark with an ID-Number that is specific to the certified product is presented on page 1 of this certificate. This document as well as the certification mark remains property of TÜV Rheinland Energy GmbH. Upon revocation of the publication the certificate loses its validity. After the expiration of the certificate and on request of this document shall be returned and the certificate mark must no longer be used. The relevant version of this certificate and its expiration date are also accessible on the internet at qal1.de. Certification of the FIDAMAT 6 MEASURING SYSTEM is based on the documents listed below and the regular, continuous surveillance of the manufacturer s quality management system: Initial certification according to EN 15267 Certificate no. 0000059868: 4 September 2018 Expiry date of the certificate: 16 July 2023 Test report: 936/21235670/A dated 12 December 2017, Cologne Publication: BAnz AT 17.07.2018 B9, chapter I number 3.1 UBA announcement dated 3 July 2018 qal1.de Page 5 of 6

Calculation of overall uncertainty according to EN 14181 and EN 15267-3 Measuring system Manufacturer Siemens AG AMS designation FIDAMAT 6 MEASURING SYSTEM Serial number of units under test H5-301 / H5-302 Measuring principle FID Test report Test laboratory Date of report 936/21235670/A TÜV Rheinland 2017-12-12 Measured component TOC Certification range 0-15 mg/m³ Evaluation of the cross-sensitivity (CS) (system with largest CS) Sum of positive CS at zero point 0.43 mg/m³ Sum of negative CS at zero point 0.00 mg/m³ Sum of postive CS at span point 0.50 mg/m³ Sum of negative CS at span point -0.20 mg/m³ Maximum sum of cross-sensitivities 0.50 mg/m³ Uncertainty of cross-sensitivity u i 0.289 mg/m³ Calculation of the combined standard uncertainty Tested parameter u² Standard deviation from paired measurements under field conditions * u D 0.022 mg/m³ 0.000 (mg/m³)² Lack of fit u lof 0.017 mg/m³ 0.000 (mg/m³)² Zero drift from field test u d,z -0.104 mg/m³ 0.011 (mg/m³)² Span drift from field test u d,s 0.260 mg/m³ 0.068 (mg/m³)² Influence of ambient temperature at span u t 0.115 mg/m³ 0.013 (mg/m³)² Influence of supply voltage u v 0.040 mg/m³ 0.002 (mg/m³)² Cross-sensitivity (interference) u i 0.289 mg/m³ 0.084 (mg/m³)² Influence of sample gas flow u p -0.040 mg/m³ 0.002 (mg/m³)² Uncertainty of reference material at 70% of certification range u rm 0.121 mg/m³ 0.015 (mg/m³)² Variation of response factors (TOC) u rf 0.456 mg/m³ 0.208 (mg/m³)² * The larger value is used : "Repeatability standard deviation at set point" or "Standard deviation from paired measurements under field conditions" å ( ) Combined standard uncertainty (u C ) u c = u max, j 0.63 mg/m³ Total expanded uncertainty U = u c * k = u c * 1.96 1.24 mg/m³ 2 Relative total expanded uncertainty U in % of the ELV 6 mg/m³ 20.7 Requirement of 2010/75/EU U in % of the ELV 6 mg/m³ 30.0 Requirement of EN 15267-3 U in % of the ELV 6 mg/m³ 22.5 qal1.de Page 6 of 6