- FLEXIBLE SPRINKLER HOSE FITTINGS FOR USE WITH COMMERCIAL SUSPENDED CEILING AND CLEAN ROOM CEILING -

Similar documents
Seung-Jin Ind.Co.,Ltd.

I-VICFLEX.AB3. Victaulic VicFlex Style AB3 Sprinkler Fittings for Surface Mount Applications WARNING WARNING INTRODUCTION

BROCHURE COMMERCIAL FIRE SPRINKLER CONNECTIONS. Product Submittal A PART OF

10.85 VicFlex Sprinkler Fittings

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

FLEXIBLE CORRUGATED TUBE

Technical Data. Outlet Connections (Ref. Figure 2) ISO 7-Rc 3/8 1/2 inch NPT 3/4 inch NPT. Nominal Assembly Lengths Ref. Table A

WARNING. Flexible Hose AH2 With AB6 With AB6. AH2-CC With AB6 With AB6

MAGNETIC DRIVE PUMPS AMERICA S MOST VERSATILE LINE OF CENTRIFUGAL PUMPS THINK QUALITY...THINK DELIVERY...THINK PRICE

TRUST THE ORIGINAL. SUBMITTAL PACKAGE

Cooling Strip Model SPB

VM99 TANK REPLACEMENT PARTS 1. COVER BOLT BOLT (4 REQ'D FOR 21-34), 1/4"-20 x 1" THERMAL CUT-OUT THERMAL TRIP PLUG

PRICE BID. UNIT QTY Rate in Figure Rate in words Amount DESCRIPTION OF ITEM D: FIRE PROTECTION SYSTEM

Victaulic VicFlex Sprinkler Fittings Series AH2 and AH2-CC Braided Flexible Hoses 10.85

SUPPLY,INSTALLATION,TESTING AND COMMISSIONING OF SPRINKLER SYSTEM AND FIRE ALARM SYSTEM FOR AIR INDIA LIMITED AT SHAMSHABAD, HYDERABAD.

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

SECTION FIRE PROTECTION

Victaulic Vic-Flex Sprinkler Fittings Series AH2 Braided Flexible Hose 10.85

TECHNICAL DATA. Wet 26a. February 22, 2009

Installing Protectowire Linear Heat Detector

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

Fight or Flee? Extinguisher Basics Extinguisher Use Extinguisher Placement and Spacing Hydrostatic Testing OSHA Requirements Test Your Knowledge

SPRINKLER ALARM TECHNICAL DATA SPRINKLER ALARM MODEL - GA

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

KRS data sheet parts list exploded view dimensional drawing sectional drawing performance curve. parts list as Excel-spreadsheet

Subchapter 7. General Industry Safety Orders Group 27. Fire Protection Article 157. Portable Fire Extinguishers. Return to index New query

Flow Switches. Liquid Flow Switches. Mounting Methods

Husky Diaphragm Pump Suction Kits

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Basic Vehicle Fire Protection Manual

5000TC Series Toroidal (Electrodeless) Conductivity Sensors. Specification. Overview. Features. Description /00 Page 1 of 8

VK3021 QUICK RESPONSE PENDENT SPRINKLER (K5.6) TECHNICAL DATA

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

Settlement Agreement. Schedule 1: Covered Products

SPRINKLERS TABLE OF CONTENTS

1 Exam Prep. Questions and Answers

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES

Integrated Process Solutions. Series 49. Thermal Management System

TECHNICAL DATA OBSOLETE

Model: FT110 Dishwasher

Cold water compact class HD 1.8/13 C Ed

Specialties Quality, Durability, Reliability. FIrE ProTECTIon

B. Related Sections: The following Sections contain requirements that relate to this Section.

A HEATER KIT With Diesel Engine Connection Fittings

SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL /

Quick closing oil drain valve, type QDV 15 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

ROTARY VANE VACUUM PUMPS Exploded View DuraVane Rotary Vane Pumps Oil-Lubricated RVL301HH

standard response/ quick response extended coverage

DISCONTINUED. Widespread Lavatory Faucet TL170DD RENESSE. Contents. Installation and Owner s Manual. English Español Français

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

Storage Sprinkler. Model LP-46 (SIN) V4603, K25, Standard Response Storage Upright Sprinkler, Patent Pending

Electrical Mini Tank Water Heater anual, and Warranty nformation

Flow Switches. Liquid Flow Switches. Mounting Methods

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

North Hanover Township School District North Hanover Township, New Jersey

FireSystems PROTECTOWIRE. Installing Protectowire Linear Heat Detector

Repair Parts List DRYER MODEL NUMBER MDG51PDAWW. When requesting service or ordering parts, always provide the following information:

(EE1500, EE2000, EE2500, EE3000)

Quick closing oil drain valve QDV

Explosion Proof 160 W Class 1 & 2 Fluorescent UV Light With 4 Lamps - Class 1 Division 1

MIG-FLEX EXTENSIBLE, FLEXIBLE METAL HOSES

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

Micro/Ultra Filtration System StamoClean CAT 430

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS

SPEAKMAN SAFETY PRODUCTS Installation Instructions SEF-TW

CATALOG OF REPLACEMENT PARTS

VDC. Wireless AC Voltage Detection Sensor. The Leader in Low-Cost, Remote Monitoring Solutions. General Description. Monnit Sensor Core Specifications

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

Toroidal (Electrodeless) Conductivity Sensors Series 5000TC Specifications

1 Exam Prep NFPA 14 Stand Pipe Systems Questions and Answers (Plumbing Contractors)

SECTION WET-PIPE SPRINKLER SYSTEMS

Explosion Proof Emergency Fluorescent Light Combination - Dimmable Ballast - C1D1-2 T8 lamps - 4'

QUICK RESPONSE ELO PENDENT SPRINKLER VK377 (STORAGE-DENSITY/AREA) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3.

TANKER & STORAGE TANK PRODUCTS

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

MATRIX 2 - COD REV.02

R7521SS COLORS/FINISHES. Stainless Steel 21 15/16" 1 3/16" 8 5/64" 1 25/32" 2 1/8" 23 5/8" Max. 1 3/8" G1/2" Female

CITY OF MADISON FIRE DEPARTMENT (MFD) FIRE PROTECTION SYSTEM PLANS

SECTION METERS AND GAGES FOR HVAC PIPING

MAIN FEATURES ADVANTAGES BENEFITS BOSS TRANSFORMER COMBI HF 110 CHEMICAL AND PHYSICAL FEATURES PACKAGING FEATURES

A sprinkler operates automatically when the heat-actuated element is heated to, or above, its thermal rating.

MATRIX 2 - COD REV.00

INSTALLATION INSTRUCTIONS

ADDITIONAL PRODUCTS 65

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

AKOCABLE Heating Cable Solutions Electrical Tracing

GAS FLOODING SYSTEM FOR CIFF AT BASEMENT

TECHNICAL INSTRUCTIONS FOR AFTER SALES ULTRA ELECTRIC PASTA COOKER

R7520SS COLORS/FINISHES. Stainless Steel 16 9/16" 7 15/16"

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

Page 1 of 7. Form No. F_ Rev Replaces Form No. F_ Rev 17.1 (added 205deg version)

4-11/16 Square Boxes. With Knockouts. Knockout Description Sides Ends Bottom. Catalog Number (Universal No.) Depth (inches) Wiring Cubic Inch Capacity

Reference Guide 2.1. Certificate Number

Instantaneous Oil-Fired Water Heater. Installation Manual OM-148. (Type B)

Transcription:

Nov-201 - FLEXIBLE SPRINKLER HOSE FITTINGS FOR USE WITH COMMERCIAL SUSPENDED CEILING AND CLEAN ROOM CEILING - - FLEXIBLE SPRINKLER HOSE FITTINGS FOR USE IN DUCTS -

- WITH COMMERCIAL SUSPENDED CEILING AND CLEAN ROOM CEILING Certification FM Approvals

WITH CLEAN ROOM CEILING SFT TYPE SEUNGJIN s SFT is used for clean room piping system of semi-conductor factories (PDP, TFT-LCD and etc) such as Samsung and LG Electronics. The product is certificated by FM Approvals. Mould Reducer is welded on the hose. It should be used in combination with sprinkler for use clean room where mould-bar on the ceiling is connected.

WITH CLEAN ROOM CEILING SFT TYPE SFT Reducer and Nipple used for exclusive use of clean rooms are welded on the both edges of the flexible tube. Generally, it is used for clean room ceilings. The customers can choose one of the two Nipple types, the Union Type(Slip Nut Type) or Welded Nipple Type. It is designed for better safety of earthquake-proof facilities.

WITH CLEAN ROOM CEILING SFT TYPE (SJ-CR-XX-B2, SJ-CR-XX-B2)

WITH CLEAN ROOM CEILING SFT TYPE (SJ-CR-XX-B1) Model Rated Pressure, psi (Bar) Outlet NPT/BSPT in inch. Assembly length, ft(mm) Number of Bends Minimum Bend Radius in. (mm) k- Factor Equivalent Length of 1 in. Schedule 40 Pipe, ft / (m) SJ-CR-07-B1 175 (12,1) ½ 2.3 (700) 1 9 (230) 5.6 18.9 (5,7) SJ-CR-10-B1 175 (12,1) ½ 3.3 (1000) 2 9 (230) 5.6 23.3 (7.1) SJ-CR-12-B1 175 (12,1) ½ 3.9 (1200) 2 9 (230) 5.6 26,3 (8) SJ-CR-15-B1 175 (12,1) ½ 4.9 (1500) 3 9 (230) 5.6 30,7 (9.3) SJ-CR-18-B1 175 (12,1) ½ 5.9 (1800) 4 9 (230) 5.6 33,5 (10,2) SJ-CR-07-B1 175 (12,1) ¾ 2.3 (700) 1 9 (230) 8 9,6 (2,9) SJ-CR-10-B1 175 (12,1) ¾ 3.3 (1000) 2 9 (230) 8 13,9 (4,4) SJ-CR-12-B1 175 (12,1) ¾ 3.9 (1200) 2 9 (230) 8 16,2 (4,9) SJ-CR-15-B1 175 (12,1) ¾ 4.9 (1500) 3 9 (230) 8 22,3 (6,8) SJ-CR-18-B1 175 (12,1) ¾ 5.9 (1800) 4 9 (230) 8 27,1 (8,3)

WITH CLEAN ROOM CEILING SFT TYPE (SJ-CR-XX-B2) Model Rated Pressure, psi Outlet NPT/BSPT in inch. Assembly length, ft(mm) Number of Bends Minimum Bend Radius in. (mm) k- Factor Equivalent Length of 1 in. Schedule 40 Pipe, ft / (m) SJ-CR-07-B2 175 (12,1) ½ 2.3 (700) 1 9 (230) 5.6 18.9 (5,7) SJ-CR-10-B2 175 (12,1) ½ 3.3 (1000) 2 9 (230) 5.6 23.3 (7.1) SJ-CR-12-B2 175 (12,1) ½ 3.9 (1175) 2 9 (230) 5.6 26,3 (8) SJ-CR-15-B2 175 (12,1) ½ 4.9 (1500) 3 9 (230) 5.6 30,7 (9.3) SJ-CR-18-B2 175 (12,1) ½ 5.9 (1800) 4 9 (230) 5.6 33,5 (10,2) SJ-CR-07-B2 175 (12,1) ¾ 2.3 (700) 1 9 (230) 8 9,6 (2,9) SJ-CR-10-B2 175 (12,1) ¾ 3.3 (1000) 2 9 (230) 8 13,9 (4,4) SJ-CR-12-B2 175 (12,1) ¾ 3.9 (1200) 2 9 (230) 8 16,2 (4,9) SJ-CR-15-B2 175 (12,1) ¾ 4.9 (1500) 3 9 (230) 8 22,3 (6,8) SJ-CR-18-B2 175 (12,1) ¾ 5.9 (1800) 4 9 (230) 8 27,1 (8,3)

WITH CLEAN ROOM CEILING SFT TYPE (SJ-CR-XX-B1, SJ-CR-XX-B2) Model SJ-CR-XX-B2 SJ-CR-XX-B2 SJ : SEUNG JIN CR : Clean Room Description Flexible Hose Length : 07=700 mm(2.3ft) 10=1000 mm(3.3ft) 15=1500 mm(4.9ft) 12=1175 mm(3.9ft) 18=1800 mm(5.9ft) B2=Bracket 1 (Thin panel Model) B2=Bracket 2 (Thick Panel Model) Part Material Quantity Flexible Tube Mould Reducer STS304 1 STS304 1 Nipple STS304 or HR 1 Fitting STS304 or S10C 1 Nut STS304 or S10C 1 Band Ring STS304 2 Max Ambient Temp, F 225 F (107 C) Adapter STS304 2 O-Ring NBR 1 Working Pressure 175psi Bracket STS304 2 K-Factor 1/2" outlet 5.6 gpm 3/4" outlet 8.0 gpm Braid STS304 1 O-Ring NBR 1

WITH COMMERCIAL SUSPENDED CEILING SGP TYPE SEUNGJIN s SGP is used for commercial ceiling or clean room piping system of semiconductor factories. The product is also certificated by FM Approvals. Union Type(Slip Nut Type) There are two types of SEUNG JIN s SGP. One is Union Type(Slip Nut Type) and the other is Welded Reducer Type. Welded Reducer Type

WITH COMMERCIAL SUSPENDED CEILING SGT TYPE Instead of the reducer used for exclusive use clean rooms, this product is developed for use commercial ceiling. It is very easy to install and assemble the products in building and office. (1) SGP Union Type(Slip Nut Type) The customers can choose various shapes and materials(sts or HR etc.) of Reducers and Nipples.

WITH COMMERCIAL SUSPENDED CEILING (1) SGP Union Type(Slip Nut Type) Part Material Quantity Flexible Tube STS304 1 Reducer STS304 or HR 1 Nipple STS304 or HR 1 Fitting STS304 or S10C 2 Nut STS304 or S10C 2 O-Ring NBR 2 Braid STS304 1 Braid Ring STS304 2 Adapter STS304 2 Square Bar SPCC 1 Bracket L1 SPCC 1 SGP Union Type and Accessories Bracket S1 SPHC 2

- FLEXIBLE SPRINKLER HOSE WITH FITTINGS FOR USE WITH COMMERCIAL SUSPENDED CEILING - The above photos show the shape of the installed Flexible Sprinkler Drops on the ceiling.

WITH COMMERCIAL SUSPENDED CEILING (1) SGP Union Type(Slip Nut Type)

WITH COMMERCIAL SUSPENDED CEILING (2) SGP Welded Reducer Type Bushing(Wing Nut) Type Aluminum Connect Type There are two types of SGP Welded Reducer Type. One is Bushing(Wing Nut) Type and the other is Aluminum Connect Type.

WITH COMMERCIAL SUSPENDED CEILING (2) SGP Welded Reducer Type - Bushing(Wing Nut) Type Part Material Quantity Bushing (Wing Nut) S10C or Brass 1

WITH COMMERCIAL SUSPENDED CEILING (2) SGP Welded Reducer Type - Aluminum Connect Type Part Material Quantity AL Clean Connect AL6061 2 O-Ring NBR 2

WITH COMMERCIAL SUSPENDED CEILING SGP Type (SPB-BXX-B1) Model Rated Pressure, psi (Bar) Outlet NPT/BSPT in inch. Assembly length, ft(mm) Number of Bends Minimum Bend Radius in. (mm) k- Factor Equivalent Length of 1 in. Schedule 40 Pipe, ft / (m) SPB-B700-B1 175 (12,1) ½ 2.3 (700) 1 9 (230) 5.6 18.9 (5,7) SPB-B1000-B1 175 (12,1) ½ 3.3 (1000) 2 9 (230) 5.6 23.3 (7.1) SPB-B1200-B1 175 (12,1) ½ 3.9 (1200) 2 9 (230) 5.6 26,3 (8) SPB-B1500-B1 175 (12,1) ½ 4.9 (1500) 3 9 (230) 5.6 30,7 (9.3) SPB-B1800-B1 175 (12,1) ½ 5.9 (1800) 4 9 (230) 5.6 33,5 (10,2) SPB-B700-B1 175 (12,1) ¾ 2.3 (700) 1 9 (230) 8 9,6 (2,9) SPB-B1000-B1 175 (12,1) ¾ 3.3 (1000) 2 9 (230) 8 13,9 (4,4) SPB-B1200-B1 175 (12,1) ¾ 3.9 (1200) 2 9 (230) 8 16,2 (4,9) SPB-B1500-B1 175 (12,1) ¾ 4.9 (1500) 3 9 (230) 8 22,3 (6,8) SPB-B1800-B1 175 (12,1) ¾ 5.9 (1800) 4 9 (230) 8 27,1 (8,3)

WITH COMMERCIAL SUSPENDED CEILING SGP Type (SPB-BXX-B2) Model Rated Pressure, psi Outlet NPT/BSPT in ïnch. Assembly length, ft(mm) Number of Bends Minimum Bend Radius in. (mm) k- Factor Equivalent Length of 1 in. Schedule 40 Pipe, ft / (m) SPB-B700-B2 175 1/2 2.3 (700) 1 9 (230) 5.6 18.9 (5,7) SPB-B1000-B2 175 1/2 3.3 (1000) 2 9 (230) 5.6 23.3 (7.1) SPB-B1200-B2 175 1/2 3.9 (1200) 2 9 (230) 5.6 26,3 (8) SPB-B1500-B2 175 1/2 4.9 (1500) 3 9 (230) 5.6 30,7 (9.3) SPB-B1800-B2 175 1/2 5.9 (1800) 4 9 (230) 5.6 33,5 (10,2) SPB-B700-B2 175 3/4 2.3 (700) 1 9 (230) 8 9,6 (2,9) SPB-B1000-B2 175 3/4 3.3 (1000) 2 9 (230) 8 13,9 (4,4) SPB-B1200-B2 175 3/4 3.9 (1200) 2 9 (230) 8 16,2 (4,9) SPB-B1500-B2 175 3/4 4.9 (1500) 3 9 (230) 8 22,3 (6,8) SPB-B1800-B2 175 3/4 5.9 (1800) 4 9 (230) 8 27,1 (8,3)

WITH COMMERCIAL SUSPENDED CEILING SGP Type(SJ-CR-XX-B2, SPB-BXX-B2) Model SPB-BXX-B2 SPB-BXX-B2 Description Flexible Hose Length : 07=700 mm(2.3ft) 10=1000 mm(3.3ft) 15=1500 mm(4.9ft) 12=1175 mm(3.9ft) 18=1800 mm(5.9ft) B2=Bracket 1 (Thin panel Model) B2=Bracket 2 (Thick Panel Model) Part Material Quantity Flexible Tube STS304 1 Reducer STS304 or HR 1 Nipple STS304 or HR 1 Fitting STS304 or S10C 2 Max Ambient Temp, F Working Pressure K-Factor 225 F (107 C) 175psi 1/2" outlet 5.6 gpm 3/4" outlet 8.0 gpm Nut STS304 or S10C 2 O-Ring NBR 2 Braid STS304 1 Braid Ring STS304 2 Adapter STS304 2

SEUNG JIN IND. CO., LTD IN DUCTS HUME DUCT TYPE In the process that the volatile gas, hydrogen chloride, or nitric acid gas made in the semi conductor factory, will be leaked outside through inner of the duct system, this product with sprinkler installed inner of duct is very helpful to extinguish the fire early. It is designed to protect sprinkler head from the corrosion resulted in hydrogen chloride, nitric acid gas and for the gas of inner duct not to leak into indoor.

IN DUCTS HUME DUCT TYPE (DUXX-YYYY)

- FLEXIBLE SPRINKLER HOSE WITH FITTINGS FOR USE WITH COMMERCIAL SUSPENDED CEILING - Union Type(SPB-BXX) UL/FM Model Rated Pressure, psi (Bar) Outlet NPT/BSPT in inch. Assembly length, ft(mm) Number of Bends Minimum Bend Radius in. (mm) k- Factor Equivalent Length of 1 in. Schedule 40 Pipe, ft / (m) SPB-B700 175 1/2 2.3 (700) 1 9 (230) 5.6 18.9 (5,7) SPB-B1000 175 1/2 3.3 (1000) 2 9 (230) 5.6 23.3 (7.1) SPB-B1200 175 1/2 3.9 (1200) 2 9 (230) 5.6 26,3 (8) SPB-B1500 175 1/2 4.9 (1500) 3 9 (230) 5.6 30,7 (9.3) SPB-B1800 175 1/2 5.9 (1800) 4 9 (230) 5.6 33,5 (10,2) SPB-B700 175 3/4 2.3 (700) 1 9 (230) 8 9,6 (2,9) SPB-B1000 175 3/4 3.3 (1000) 2 9 (230) 8 13,9 (4,4) SPB-B1200 175 3/4 3.9 (1200) 2 9 (230) 8 16,2 (4,9) SPB-B1500 175 3/4 4.9 (1500) 3 9 (230) 8 22,3 (6,8) SPB-B1800 175 3/4 5.9 (1800) 4 9 (230) 8 27,1 (8,3)

IN DUCTS HUME DUCT TYPE (DUXX-YYYY) Model BSPT in. Hose Assembly length, ft(m) Equivalent Length of 1 in. Schedule 40 Pipe, ft(m) DUXX-YYYY 1/2 2.6(0.8) 8.3(2.6) DUXX-YYYY 1/2 8.5(2.6) 31.8(9.7) DUXX-YYYY 3/4 2.6(0.8) 7.6(2.3) DUXX-YYYY 3/4 8.5(2.6) 31.4(9.6) Model DUXX-YYYY DU : Duct Description XX : Product Length. 08 (08 is a 0.8m(2.6 ft) through 26 long hose assembly and26 is a 2.6m(8.5ft) long hose assembly. YYYY : Year and month manufactured. At present, the maximum length of a flexible sprinkler hose assembly including end connections, is up to 1.8 m(6 ft) by new FM Approvals policy. (FM Class Number 1637, Feb. 2010)

IN DUCTS HUME DUCT TYPE (DUXX-YYYY) Temperature Pressure Connection Minimum Bend Radius K-Factor 225 F (107 C) 175psi Inlet 1" Outlet 1/2" or 3/4" 8" 1/2" outlet 5.6 gpm 3/4" outlet 8.0 gpm Part Material Quantity Flexible Tube STS304 1 Nipple STS304 or HR 1 Nut STS304 or S10C 2 Fitting STS304 or S10C 2 Band-Ring STS304 2 Adapter STS304 2 Braid STS304 1 O-Ring NBR 2