Nov-201 - FLEXIBLE SPRINKLER HOSE FITTINGS FOR USE WITH COMMERCIAL SUSPENDED CEILING AND CLEAN ROOM CEILING - - FLEXIBLE SPRINKLER HOSE FITTINGS FOR USE IN DUCTS -
- WITH COMMERCIAL SUSPENDED CEILING AND CLEAN ROOM CEILING Certification FM Approvals
WITH CLEAN ROOM CEILING SFT TYPE SEUNGJIN s SFT is used for clean room piping system of semi-conductor factories (PDP, TFT-LCD and etc) such as Samsung and LG Electronics. The product is certificated by FM Approvals. Mould Reducer is welded on the hose. It should be used in combination with sprinkler for use clean room where mould-bar on the ceiling is connected.
WITH CLEAN ROOM CEILING SFT TYPE SFT Reducer and Nipple used for exclusive use of clean rooms are welded on the both edges of the flexible tube. Generally, it is used for clean room ceilings. The customers can choose one of the two Nipple types, the Union Type(Slip Nut Type) or Welded Nipple Type. It is designed for better safety of earthquake-proof facilities.
WITH CLEAN ROOM CEILING SFT TYPE (SJ-CR-XX-B2, SJ-CR-XX-B2)
WITH CLEAN ROOM CEILING SFT TYPE (SJ-CR-XX-B1) Model Rated Pressure, psi (Bar) Outlet NPT/BSPT in inch. Assembly length, ft(mm) Number of Bends Minimum Bend Radius in. (mm) k- Factor Equivalent Length of 1 in. Schedule 40 Pipe, ft / (m) SJ-CR-07-B1 175 (12,1) ½ 2.3 (700) 1 9 (230) 5.6 18.9 (5,7) SJ-CR-10-B1 175 (12,1) ½ 3.3 (1000) 2 9 (230) 5.6 23.3 (7.1) SJ-CR-12-B1 175 (12,1) ½ 3.9 (1200) 2 9 (230) 5.6 26,3 (8) SJ-CR-15-B1 175 (12,1) ½ 4.9 (1500) 3 9 (230) 5.6 30,7 (9.3) SJ-CR-18-B1 175 (12,1) ½ 5.9 (1800) 4 9 (230) 5.6 33,5 (10,2) SJ-CR-07-B1 175 (12,1) ¾ 2.3 (700) 1 9 (230) 8 9,6 (2,9) SJ-CR-10-B1 175 (12,1) ¾ 3.3 (1000) 2 9 (230) 8 13,9 (4,4) SJ-CR-12-B1 175 (12,1) ¾ 3.9 (1200) 2 9 (230) 8 16,2 (4,9) SJ-CR-15-B1 175 (12,1) ¾ 4.9 (1500) 3 9 (230) 8 22,3 (6,8) SJ-CR-18-B1 175 (12,1) ¾ 5.9 (1800) 4 9 (230) 8 27,1 (8,3)
WITH CLEAN ROOM CEILING SFT TYPE (SJ-CR-XX-B2) Model Rated Pressure, psi Outlet NPT/BSPT in inch. Assembly length, ft(mm) Number of Bends Minimum Bend Radius in. (mm) k- Factor Equivalent Length of 1 in. Schedule 40 Pipe, ft / (m) SJ-CR-07-B2 175 (12,1) ½ 2.3 (700) 1 9 (230) 5.6 18.9 (5,7) SJ-CR-10-B2 175 (12,1) ½ 3.3 (1000) 2 9 (230) 5.6 23.3 (7.1) SJ-CR-12-B2 175 (12,1) ½ 3.9 (1175) 2 9 (230) 5.6 26,3 (8) SJ-CR-15-B2 175 (12,1) ½ 4.9 (1500) 3 9 (230) 5.6 30,7 (9.3) SJ-CR-18-B2 175 (12,1) ½ 5.9 (1800) 4 9 (230) 5.6 33,5 (10,2) SJ-CR-07-B2 175 (12,1) ¾ 2.3 (700) 1 9 (230) 8 9,6 (2,9) SJ-CR-10-B2 175 (12,1) ¾ 3.3 (1000) 2 9 (230) 8 13,9 (4,4) SJ-CR-12-B2 175 (12,1) ¾ 3.9 (1200) 2 9 (230) 8 16,2 (4,9) SJ-CR-15-B2 175 (12,1) ¾ 4.9 (1500) 3 9 (230) 8 22,3 (6,8) SJ-CR-18-B2 175 (12,1) ¾ 5.9 (1800) 4 9 (230) 8 27,1 (8,3)
WITH CLEAN ROOM CEILING SFT TYPE (SJ-CR-XX-B1, SJ-CR-XX-B2) Model SJ-CR-XX-B2 SJ-CR-XX-B2 SJ : SEUNG JIN CR : Clean Room Description Flexible Hose Length : 07=700 mm(2.3ft) 10=1000 mm(3.3ft) 15=1500 mm(4.9ft) 12=1175 mm(3.9ft) 18=1800 mm(5.9ft) B2=Bracket 1 (Thin panel Model) B2=Bracket 2 (Thick Panel Model) Part Material Quantity Flexible Tube Mould Reducer STS304 1 STS304 1 Nipple STS304 or HR 1 Fitting STS304 or S10C 1 Nut STS304 or S10C 1 Band Ring STS304 2 Max Ambient Temp, F 225 F (107 C) Adapter STS304 2 O-Ring NBR 1 Working Pressure 175psi Bracket STS304 2 K-Factor 1/2" outlet 5.6 gpm 3/4" outlet 8.0 gpm Braid STS304 1 O-Ring NBR 1
WITH COMMERCIAL SUSPENDED CEILING SGP TYPE SEUNGJIN s SGP is used for commercial ceiling or clean room piping system of semiconductor factories. The product is also certificated by FM Approvals. Union Type(Slip Nut Type) There are two types of SEUNG JIN s SGP. One is Union Type(Slip Nut Type) and the other is Welded Reducer Type. Welded Reducer Type
WITH COMMERCIAL SUSPENDED CEILING SGT TYPE Instead of the reducer used for exclusive use clean rooms, this product is developed for use commercial ceiling. It is very easy to install and assemble the products in building and office. (1) SGP Union Type(Slip Nut Type) The customers can choose various shapes and materials(sts or HR etc.) of Reducers and Nipples.
WITH COMMERCIAL SUSPENDED CEILING (1) SGP Union Type(Slip Nut Type) Part Material Quantity Flexible Tube STS304 1 Reducer STS304 or HR 1 Nipple STS304 or HR 1 Fitting STS304 or S10C 2 Nut STS304 or S10C 2 O-Ring NBR 2 Braid STS304 1 Braid Ring STS304 2 Adapter STS304 2 Square Bar SPCC 1 Bracket L1 SPCC 1 SGP Union Type and Accessories Bracket S1 SPHC 2
- FLEXIBLE SPRINKLER HOSE WITH FITTINGS FOR USE WITH COMMERCIAL SUSPENDED CEILING - The above photos show the shape of the installed Flexible Sprinkler Drops on the ceiling.
WITH COMMERCIAL SUSPENDED CEILING (1) SGP Union Type(Slip Nut Type)
WITH COMMERCIAL SUSPENDED CEILING (2) SGP Welded Reducer Type Bushing(Wing Nut) Type Aluminum Connect Type There are two types of SGP Welded Reducer Type. One is Bushing(Wing Nut) Type and the other is Aluminum Connect Type.
WITH COMMERCIAL SUSPENDED CEILING (2) SGP Welded Reducer Type - Bushing(Wing Nut) Type Part Material Quantity Bushing (Wing Nut) S10C or Brass 1
WITH COMMERCIAL SUSPENDED CEILING (2) SGP Welded Reducer Type - Aluminum Connect Type Part Material Quantity AL Clean Connect AL6061 2 O-Ring NBR 2
WITH COMMERCIAL SUSPENDED CEILING SGP Type (SPB-BXX-B1) Model Rated Pressure, psi (Bar) Outlet NPT/BSPT in inch. Assembly length, ft(mm) Number of Bends Minimum Bend Radius in. (mm) k- Factor Equivalent Length of 1 in. Schedule 40 Pipe, ft / (m) SPB-B700-B1 175 (12,1) ½ 2.3 (700) 1 9 (230) 5.6 18.9 (5,7) SPB-B1000-B1 175 (12,1) ½ 3.3 (1000) 2 9 (230) 5.6 23.3 (7.1) SPB-B1200-B1 175 (12,1) ½ 3.9 (1200) 2 9 (230) 5.6 26,3 (8) SPB-B1500-B1 175 (12,1) ½ 4.9 (1500) 3 9 (230) 5.6 30,7 (9.3) SPB-B1800-B1 175 (12,1) ½ 5.9 (1800) 4 9 (230) 5.6 33,5 (10,2) SPB-B700-B1 175 (12,1) ¾ 2.3 (700) 1 9 (230) 8 9,6 (2,9) SPB-B1000-B1 175 (12,1) ¾ 3.3 (1000) 2 9 (230) 8 13,9 (4,4) SPB-B1200-B1 175 (12,1) ¾ 3.9 (1200) 2 9 (230) 8 16,2 (4,9) SPB-B1500-B1 175 (12,1) ¾ 4.9 (1500) 3 9 (230) 8 22,3 (6,8) SPB-B1800-B1 175 (12,1) ¾ 5.9 (1800) 4 9 (230) 8 27,1 (8,3)
WITH COMMERCIAL SUSPENDED CEILING SGP Type (SPB-BXX-B2) Model Rated Pressure, psi Outlet NPT/BSPT in ïnch. Assembly length, ft(mm) Number of Bends Minimum Bend Radius in. (mm) k- Factor Equivalent Length of 1 in. Schedule 40 Pipe, ft / (m) SPB-B700-B2 175 1/2 2.3 (700) 1 9 (230) 5.6 18.9 (5,7) SPB-B1000-B2 175 1/2 3.3 (1000) 2 9 (230) 5.6 23.3 (7.1) SPB-B1200-B2 175 1/2 3.9 (1200) 2 9 (230) 5.6 26,3 (8) SPB-B1500-B2 175 1/2 4.9 (1500) 3 9 (230) 5.6 30,7 (9.3) SPB-B1800-B2 175 1/2 5.9 (1800) 4 9 (230) 5.6 33,5 (10,2) SPB-B700-B2 175 3/4 2.3 (700) 1 9 (230) 8 9,6 (2,9) SPB-B1000-B2 175 3/4 3.3 (1000) 2 9 (230) 8 13,9 (4,4) SPB-B1200-B2 175 3/4 3.9 (1200) 2 9 (230) 8 16,2 (4,9) SPB-B1500-B2 175 3/4 4.9 (1500) 3 9 (230) 8 22,3 (6,8) SPB-B1800-B2 175 3/4 5.9 (1800) 4 9 (230) 8 27,1 (8,3)
WITH COMMERCIAL SUSPENDED CEILING SGP Type(SJ-CR-XX-B2, SPB-BXX-B2) Model SPB-BXX-B2 SPB-BXX-B2 Description Flexible Hose Length : 07=700 mm(2.3ft) 10=1000 mm(3.3ft) 15=1500 mm(4.9ft) 12=1175 mm(3.9ft) 18=1800 mm(5.9ft) B2=Bracket 1 (Thin panel Model) B2=Bracket 2 (Thick Panel Model) Part Material Quantity Flexible Tube STS304 1 Reducer STS304 or HR 1 Nipple STS304 or HR 1 Fitting STS304 or S10C 2 Max Ambient Temp, F Working Pressure K-Factor 225 F (107 C) 175psi 1/2" outlet 5.6 gpm 3/4" outlet 8.0 gpm Nut STS304 or S10C 2 O-Ring NBR 2 Braid STS304 1 Braid Ring STS304 2 Adapter STS304 2
SEUNG JIN IND. CO., LTD IN DUCTS HUME DUCT TYPE In the process that the volatile gas, hydrogen chloride, or nitric acid gas made in the semi conductor factory, will be leaked outside through inner of the duct system, this product with sprinkler installed inner of duct is very helpful to extinguish the fire early. It is designed to protect sprinkler head from the corrosion resulted in hydrogen chloride, nitric acid gas and for the gas of inner duct not to leak into indoor.
IN DUCTS HUME DUCT TYPE (DUXX-YYYY)
- FLEXIBLE SPRINKLER HOSE WITH FITTINGS FOR USE WITH COMMERCIAL SUSPENDED CEILING - Union Type(SPB-BXX) UL/FM Model Rated Pressure, psi (Bar) Outlet NPT/BSPT in inch. Assembly length, ft(mm) Number of Bends Minimum Bend Radius in. (mm) k- Factor Equivalent Length of 1 in. Schedule 40 Pipe, ft / (m) SPB-B700 175 1/2 2.3 (700) 1 9 (230) 5.6 18.9 (5,7) SPB-B1000 175 1/2 3.3 (1000) 2 9 (230) 5.6 23.3 (7.1) SPB-B1200 175 1/2 3.9 (1200) 2 9 (230) 5.6 26,3 (8) SPB-B1500 175 1/2 4.9 (1500) 3 9 (230) 5.6 30,7 (9.3) SPB-B1800 175 1/2 5.9 (1800) 4 9 (230) 5.6 33,5 (10,2) SPB-B700 175 3/4 2.3 (700) 1 9 (230) 8 9,6 (2,9) SPB-B1000 175 3/4 3.3 (1000) 2 9 (230) 8 13,9 (4,4) SPB-B1200 175 3/4 3.9 (1200) 2 9 (230) 8 16,2 (4,9) SPB-B1500 175 3/4 4.9 (1500) 3 9 (230) 8 22,3 (6,8) SPB-B1800 175 3/4 5.9 (1800) 4 9 (230) 8 27,1 (8,3)
IN DUCTS HUME DUCT TYPE (DUXX-YYYY) Model BSPT in. Hose Assembly length, ft(m) Equivalent Length of 1 in. Schedule 40 Pipe, ft(m) DUXX-YYYY 1/2 2.6(0.8) 8.3(2.6) DUXX-YYYY 1/2 8.5(2.6) 31.8(9.7) DUXX-YYYY 3/4 2.6(0.8) 7.6(2.3) DUXX-YYYY 3/4 8.5(2.6) 31.4(9.6) Model DUXX-YYYY DU : Duct Description XX : Product Length. 08 (08 is a 0.8m(2.6 ft) through 26 long hose assembly and26 is a 2.6m(8.5ft) long hose assembly. YYYY : Year and month manufactured. At present, the maximum length of a flexible sprinkler hose assembly including end connections, is up to 1.8 m(6 ft) by new FM Approvals policy. (FM Class Number 1637, Feb. 2010)
IN DUCTS HUME DUCT TYPE (DUXX-YYYY) Temperature Pressure Connection Minimum Bend Radius K-Factor 225 F (107 C) 175psi Inlet 1" Outlet 1/2" or 3/4" 8" 1/2" outlet 5.6 gpm 3/4" outlet 8.0 gpm Part Material Quantity Flexible Tube STS304 1 Nipple STS304 or HR 1 Nut STS304 or S10C 2 Fitting STS304 or S10C 2 Band-Ring STS304 2 Adapter STS304 2 Braid STS304 1 O-Ring NBR 2