Residential Fire Protection Sprinklers & Systems

Similar documents
AESTHETIC SPRINKLERS.

S p e c i a l P u r p o s e S p r i n k l e r s. Attic Spaces Retail Windows High Security Institutions Minimal Water Damage Conditions

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

Simple On The Outside...

ESCUTCHEON PLATE SEATING 3/4" NPT SURFACE. 1-1/2" (38,1 mm) CROSS SECTION PENDENT RECESSED PENDENT

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

Page 1 of 8 DECEMBER 2018 TFP408. Worldwide Contacts.

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Domed-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

HELP THEM PROTECT THEIR WORLD.

Sprinkler Solutions for Storage Applications

FIGURE 1 MODEL RFIII ECLH CONCEALED HSW SPRINKLER ASSEMBLY AND FEATURES. 5/16" (7,9 mm) MIN. 9/16" (14,3 mm) MAX.

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

Series DS-1 Dry-Type Sprinklers 5.6K Pendent, Upright, and Horizontal Sidewall Quick Response, Standard Coverage General Description

TECHNICAL DATA MODEL V-HIP SPECIFIC APPLICATION ATTIC SPRINKLER VK660

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

as required for residential sprinklers intended for use in dry pipe systems.

STORAGE FIRE PROTECTION SPRINKLERS

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

ATTIC UPRIGHT SPECIFIC APPLICATION SPRINKLER VK696 TECHNICAL DATA

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems

WATERSIDE BUILDING GROUP E4

Sprinkler Identification Numbers

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

culus Listed: Category VNIV Refer to the Approval Chart on page 3. VK697 Attic Upright Sprinkler Specifications:

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

Sprinkler Identification Number (SIN)

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Fire Protection Products Technical Data Book Table of Contents, August 2017

Sprinkler Identification Numbers

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

MODEL V-BB SPECIFIC APPLICATION TECHNICAL DATA

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Pendent Wet Pipe and Dry Pipe Systems General Description

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

* Temperature rating is FIGURE K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331) SPRINKLERS

The Series LFII (TY3596) Residential

Submittal Packages Detailed with Items and Reviewers

Review of Residential Fire Sprinkler Systems for One- and Two-Family Dwellings

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

Sprinkler Identification Number. Page 1 of 6 AUGUST 2018 TFP288. Worldwide Contacts.

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

Models BB, SD, HIP, and AP Specific Application Sprinklers For Protecting Attics General Description

Sprinkler Identification Number (SIN) TY4234. Page 1 of 8 APRIL 2012 TFP Technical Services

E x t E N d e d Co v e r ag e S p r i n k l e r s. Office Buildings Hotels Hospitals Libraries. High-Piled Storage Big-Box Retailing

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

Model F3 Dry Sprinklers

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response)

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA

quick response sprinkler vk194 Sprinkler 104j January 1, 2011

quick response Sprinkler 105a October 25, 2010

Full-scale tested, for use in wood truss construction. Listed for specific roof slopes from 4:12 to 12:12.

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

RAPID RESPONSE Series LFII Residential Sprinklers 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe and Dry Pipe Systems

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

5.6K Pendent, Upright, and Horizontal Sidewall Standard Response, Standard Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

The Viking Corporation s Web site at Rated to 175 psi (12 bar) water working pressure

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

Model WS TM 5.6 K-factor Specific Application Window Sprinklers, Horizontal and Pendent Vertical Sidewall General Description

C. All components of the systems described shall meet the requirements as stated herein and shall be approved by the Architect and Consultant.

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

Standard Spray concealed horizontal sidewall sprinkler VK481

standard response dry horizontal sidewall sprinklers

TECHNICAL DATA. The Viking Corporation s Web site at Frame Casting: Brass UNS-C84400

standard response/ quick response extended coverage

December 14, 2015 Page 1 of 7 TECHNICAL DATA

Solutions at every turn.

TECHNICAL DATA. Page 1 of 5

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

G3/8" DIN ISO 228 THREAD SHOULDER AND DUST CAP MATING SURFACE. STYLE H ESCUTCHEON (SEPARATELY ORDERED) 85 mm DIA. (3-3/8")

Model G5-56 Dry (SIN RA5114) K5.6 (80 metric) Concealed Dry Pendent Sprinkler

Transcription:

Residential Fire Protection Sprinklers & Systems Product Guide LFII Residential Sprinklers Sprinkler System Components CPVC Pipe & Fittings Specific Application Attic Sprinklers LFP Antifreeze for Fire Sprinkler Systems

Developed specifically for residential occupancies The most complete system on the market today from a single manufacturer Features BlazeMaster CPVC pipe and fittings, making installation quick, easy flexible, and affordable LFP Antifreeze is the first and only UL Certified solution for fire sprinkler systems Exclusive ten-year limited warranty lets you install with confidence Product line meets all NFPA standards Components are all UL listed for residential installations

Residential Fire Protection Sprinklers & Systems Product Guide Table of Contents Series LFII Sprinklers 2-6 Series LFII Dry Sprinklers 7 Series LFII NFPA 13 Optimized Sprinklers 8-11 CPVC Pipe and Fittings 12-13 Specific Application Attic Sprinklers 14 LFP Antifreeze for Fire Sprinkler Systems 15 System Components 16

Series LFII Sprinklers LFII (TY2234) Pendent, Recessed Pendent and Domed Concealed Approved for special applications with beamed ceilings Used in wet pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D Used in wet pipe residential occupancies up to and including four stories in height per NFPA 13R Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 Can also be used in dry pipe systems per NFPA 13D, 13R, and 13 hydraulic design criteria We can match any Sherwin Williams color for Flat Plate and Domed Concealed sprinklers you install. See the cover plate chart on page 7 for standard colors and finishes. K Factor K=4.9 (70,6) Thread Size 1/2 (15 mm) Escutcheon Style 20 Bulb Type 3 mm White, Chrome, Brass, Custom Tech Data TFP400 (TFP450 Domed Concealed) LFII (TY1234) Pendent and Recessed Pendent Used in wet pipe residential sprinkler systems for one-and twofamily dwellings and mobile homes per NFPA 13D Used in wet pipe sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R K Factor K=3.0 (43,2) Thread Size 1/2 (15 mm) Bulb Type 3 mm White, Chrome, Brass Tech Data TFP402 2 Rapid Response

Always refer to the technical data sheet for complete description and all listing criteria, design parameters, installation instructions, care and maintenance guidelines and limited warranty. LFII (TY1334) Horizontal and Recessed Horizontal Sidewall Used in wet and dry pipe residential sprinkler systems for oneand two-family dwellings and mobile homes per NFPA 13D Used in wet and dry pipe residential occupancies up to and including four stories in height per NFPA 13R Used in wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 K Factor K=4.2 (60,5) Thread Size 1/2 (15 mm) Escutcheon Style 20 Bulb Type 3 mm White, Chrome, Brass Tech Data TFP410 LFII (TY2334) Horizontal and Recessed Horizontal Sidewall Used in wet pipe residential sprinkler systems for one- and two-family dwellings and mobile homes per NFPA 13D Used in wet pipe residential occupancies up to and including four stories in height per NFPA 13R Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 K Factor K=4.4 (63,4) Thread Size 1/2 (15 mm) Escutcheon Style 20 Bulb Type 3 mm White, Chrome, Brass Tech Data TFP412 www.tyco-rapidresponse.com 3

Series LFII Sprinklers LFII (TY3596) Flat Plate Concealed Pendent Solder type Can be used for horizontal and sloped ceilings Used in wet and dry pipe residential sprinkler systems for oneand two-family dwellings and mobile homes per NFPA 13D Used in wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R Cover plate conceals sprinkler components above ceiling Can also be used in dry pipe systems per NFPA 13D, 13R, and 13 hydraulic design criteria We can match any Sherwin Williams color for Flat Plate and Domed Concealed sprinklers you install. See the cover plate chart on page 7 for standard colors and finishes. K Factor K= 4.9 (70,6) Thread Size Tech Data 1/2 (15 mm) White, Chrome, Brass, Custom TFP442 New LFII intermediate temperature cover plates feature a reduced gap between the plate and the ceiling surface for a more flush appearance. Flat Plate Concealed Cover Plate Tool Specially designed for installing and removing TYCO LFII, RFII and RFIII Flat plate concealed cover plates Contains foam insert to prevent scratching of cover plate finish Attaches to painter s pole, or a length of 1 CPVC pipe No need for ladder or scaffold to install cover plates 4 Rapid Response

Flat Plate Concealed Cover Plate Colors & es Grey White (RAL 9002) Signal White (RAL 9003) Pure White (RAL 9010) Light Ivory (RAL 1015) Beige (RAL 1001) Terra Brown (RAL 8028) Jet Black (RAL 9005) Brushed Brass Brushed Chrome Custom Colors Available tyco-fire.com/custompaint Before Making A Final Color Selection The purpose of this color chart is to provide a basic representation of Rapid Response Flat Plate Concealed Cover Plate finish colors. This color chart shall not be used for final color selection, as color differences may occur in print and on monitors when compared to the actual product. Actual custom color selection should be made from a Sherwin Williams paint swatch. Please contact your Rapid Response representative for more information. www.tyco-rapidresponse.com 5

Series LFII Sprinklers LFII (TY2284) Flush Pendent Solder type Approved for special applications with beamed ceilings Used in wet and dry pipe residential sprinkler systems for oneand two-family dwellings and mobile homes per NFPA 13D Used in wet and dry pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R Used in wet and dry pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 K Factor K=4.2 (60,5) Thread Size 1/2 (15 mm) White, Chrome, Brass, Black Tech Data TFP420 LFII (TY2284) Flush Horizontal Sidewall Solder type Approved for special applications with beamed ceilings Used in wet pipe residential sprinkler systems for one- and twofamily dwellings and mobile homes per NFPA 13D Used in wet pipe residential sprinkler systems for residential occupancies up to and including four stories in height per NFPA 13R Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 K Factor K= 4.2 (60,5) Thread Size 1/2 (15 mm) White, Chrome, Brass Tech Data TFP425 6 Rapid Response

Series LFII Dry Sprinklers LFII (TY2235) Residential Dry Sprinkler, Recessed Pendent For residential occupancies per NFPA 13D, 13R and residential portions of any occupancy per NFPA 13 UL listed for use in wet pipe, dry pipe and pre action systems K Factor K=4.9 (70,6) Thread Size 1 NPT (25 mm) Bulb Type 3 mm White, Chrome, Brass Tech Data TFP460 LFII (TY2335) Residential Dry Sprinkler, Horizontal Sidewall For residential occupancies per NFPA 13D, 13R and residential portions of any occupancy per NFPA 13 UL listed for use in wet pipe, dry pipe and pre action systems K Factor K=4.4 (63,4) Thread Size 1 NPT (25 mm) Bulb Type 3 mm White, Chrome, Brass Tech Data TFP461 www.tyco-rapidresponse.com 7

NFPA 13 Optimized Sprinklers LFII (TY4234) Pendent, Recessed Pendent and Domed Concealed Used in wet pipe residential sprinkler sys tems for one- and twofamily dwellings and mobile homes per NFPA 13D Used in wet pipe residential occupancies up to and including four stories in height per NFPA 13R Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 We can match any Sherwin Williams color for Flat Plate and Domed Concealed sprinklers you install. See the cover plate chart on page 7 for standard colors and finishes. K Factor K=6.9 (99,4) Thread Size 3/4 (19.05 mm) Escutcheon Style 30 Bulb Type 3 mm White, Chrome, Brass, Custom Tech Data TFP408 8 Rapid Response

LFII (TY3934) 5.8K Pendent, Recessed Pendent UL and C-UL Listed Used in wet pipe residential sprinkler systems for one- and twofamily dwellings and mobile homes per NFPA 13D Used in wet pipe residential occupancies up to and including four stories in height per NFPA 13R Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 K Factor K=5.8 (83,5) Thread Size 1/2 (19.05 mm) Escutcheon Style 20 Bulb Type Tech Data 3 mm Natural Brass, White, Black, Chrome TFP401

NFPA 13 Optimized Sprinklers LFII (TY3334) Horizontal and Recessed Horizontal Sidewall Used in wet pipe residential sprinkler systems for one- and twofamily dwellings and mobile homes per NFPA 13D Used in wet pipe residential occupancies up to and including four stories in height per NFPA 13R Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 K Factor K=5.6 (80,6) Thread Size 1/2 (15 mm) Escutcheon Style 20 Bulb Type 3 mm White, Chrome, Brass Tech Data TFP415 10 Rapid Response

LFII (TY4334) Horizontal and Recessed Horizontal Sidewall Used in wet pipe residential sprinkler systems for one- and twofamily dwellings and mobile homes per NFPA 13D Used in wet pipe residential occupancies up to and including four stories in height per NFPA 13R Used in wet pipe sprinkler systems for the residential portions of any occupancy per NFPA 13 K Factor K=5.8 (80,6) Thread Size 1/2 (15 mm) Bulb Type 3 mm White, Chrome, Brass Tech Data TFP417

CPVC Pipe & Fittings The Rapid Response Residential Fire Sprinkler System features CPVC Pipe and Fittings manufactured with Lubrizol s BlazeMaster compound listed by Underwriters Laboratories, Inc. for use in: Light hazard occupancies as defined in the Standard for Installation of Fire Sprinkler Systems, NFPA 13 Residential occupancies as defined in the Standard for Installation of Fire Sprinkler Systems in Residential Occupancies up to Four Stories in Height, NFPA 13R Residential occupancies as defined in the Standard for Fire Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes, NFPA 13D COUPLING PIPE (3/4 3 ) Air plenums, as defined by the Installation of Air Conditioning and Ventilating Systems, NFPA 90A and model mechanical codes Underground water pressure service, NFPA 24 Unfinished basements (Note: for complete listing and approval information, please refer to the installation instructions and technical manual IH-1900) ELBOW 90 REDUCING COUPLING ELBOW 45 TEE REDUCING TEE BACK-TO-BACK SPRINKLER HEAD ADAPTER BUSHING CROSS CAP 90 ELBOW SPRINKLER HEAD ADAPTER SPIGOT SPRINKLER HEAD ADAPTER (SLIP X FIPT) FEMALE SPRINKLER HEAD ADAPTER (EAST) FEMALE SPRINKLER HEAD ADAPTER (WEST) 12 Rapid Response

Install With Confidence Tyco BlazeMaster CPVC Piping Systems are UL and cul listed, FM approved, and exceed ASTM standards. Benefits over traditional piping systems include: Resistant to rust, scale and foreign contaminant buildup Superior flow characteristics for increased hydraulic capabilities (C-Factor=150) Easily transported, handled and modified on site Can be easily connected to copper and steel piping Resist sweating and condensation Immune to Microbiologically Influenced Corrosion (MIC) Fire Performance CPVC has an LOI (Limited Oxygen Index) that is better than wood, PVC, PB or other common building materials. It will not support combustion; therefore, it cannot be the source of a fire or cause a fire to spread. Does not contribute to flashover Low smoke generation Toxicity is extremely low when compared with common building and finishing materials; equal to wood and less than wool or cotton (University of Pittsburgh protocol) CPVC TO COPPER- MALE ADAPTER (SLIP X MALE) CPVC TO COPPER-FEMALE ADAPTER (SLIP X FEMALE) BACK-TO-BACK CROSS SPRINKLER HEAD ADAPTER GROOVED COUPLING ADAPTER (GROOVE X SLIP) Rapid Seal Sprinkler Head Adapter Fittings All-CPVC sprinkler head adapter fittings No brass, no lead, no dezincification Easier sprinkler installation No need for thread tape or sealant UL, ULc, FM, NSF, and LPCB approved Multiple sizes and styles 90 ELBOW SPRINKLER HEAD ADAPTER FEMALE SPRINKLER HEAD ADAPTER SPIGOT SPRINKLER HEAD ADAPTER (SLIP X FIPT) www.tyco-rapidresponse.com 13

Specific Application Sprinklers for Protecting Attics Specific Application Attic Sprinklers provide superior fire protection in attic spaces and, when compared to Standard Spray Sprinklers, cost savings are achieved by eliminating branch line materials and the associated installation labor. The Specific Application Sprinklers For Protecting Attics have under gone the most extensive fire testing ever performed for sloped attic spaces. They are UL Listed with their specific application guidelines for use as special sprinklers as defined by the NFPA. Listed for extended coverage in combustible construction Full-scale fire tested in both wet and dry system scenarios FLAT SPRAY PATTERN Full-scale tested for use in wood truss construction AP -Attic Plus RIDGE UP TO 120 FT 2 Listed for specific roof slopes FLOW FLOW EAVE SPAN UP TO 60 FEET BB -Back to Back 6 FEET EAVE FLOW SPAN UP TO 28 FEET 90 HIP EAVE HIP RIDGE EAVE FLOW RIDGE SD -Single Direction 6 FEET EAVE SPAN UP TO 40 FEET 14 Rapid Response

LFP Antifreeze for Fire Sprinkler Systems LFP Antifreeze is the first and only UL Certified antifreeze solution for fire sprinkler systems. This pre-mixed solution is formulated to help protect against freeze damage failure and ensure flow in wet pipe fire sprinkler systems. Additionally, LFP Antifreeze is both more cost-effective and easier to install and maintain than alternate freeze protection methods, such as heat tracing or dry systems. Helps meet requirements for NFPA 13, 13R, 13D and 25 Freeze point -10 F (-23,3 C) Certified for use in residential, commercial and some storage applications Compatible with both CPVC and steel pipe Non-toxic* * For the purpose of this product, non-toxic means acute exposure to ingredients in the LFP Antifreeze does not pose a risk of adverse effects in humans or the environment following short-term exposure in scenarios related to fire sprinkler system installation, maintenance, and discharge.

System Components Residential Domestic Shut-off Valve 1 and 2 Used in piping systems that supply water to both domestic service and the fire sprinkler system per NFPA 13D or 13R in one/two- family dwellings and mobile homes In the set position, water is available on demand to the domestic system, and the valve acts as a check valve for the fire protection system When a sprinkler operates, the supply to the domestic system is automatically shut off, maximizing the available water supply for fire protection Eliminates the need for expensive pumps, pressurized tanks, or electrically operated domestic shutoff valves Powerball Butterfly Valves Ideal for use in residential sprinkler systems as main control valves An alternative to bulky OS&Y valves Mandated visual indicator showing that the valve is open or closed Available from 1 through 2-1/2 Resi-Riser Compact, pre-assembled, ready to install sprinkler riser Brass construction for use in potable water supply Available in 1-2 (25 mm - 50 mm) sizes Integral test and drain assembly, flow switch with retard mechanism, 300 psi gauge, and check valve Compact size allows for easy installation between 2 x 4 studs in wall Molded mounting points allow for fast and easy left or right-hand installation Available with or without pressure relief valve feature and flow switch retard mechanism RM-1 Riser Manifold Available in 1-2 Available in either threaded or grooved configurations Meets NFPA 13, 13R, and 13D requirements 16 Rapid Response

Model VS-SP WaterFlow Detector Used with wet pipe sprinkler systems in residential dwellings and mobile homes Actuation of the switch can initiate an alarm indicating that the sprinkler system is operating Sustained flow of 8 gallons per minute will deflect the vane and actuate a single-pole, double-throw snap action switch Can be wired to a local bell and/or protection panel for outside notification to an alarm company or fire department Hangers for BlazeMaster CPVC Products Rapid Response offers a full line of pipe hangers designed especially for use with BlazeMaster CPVC Products. Designed for ease of installation Hangers have rounded edges to prevent damage to pipe and fittings Meets the requirements specified in NFPA 13, NFPA 13R, and NFPA 13D Sprinkler Head Cabinet Spare sprinkler head cabinets are available. All cabinets have ample room for sprinkler wrench storage. Electric Alarm Bell Ideally suited for residential applications Unobtrusive to the homeowner, yet absolutely dependable in a fire event When used with a flow switch, if water flow occurs in a sprinkler system protecting residential occupancies, an audible alarm sounds to alert the occupants and neighbors of trouble CPVC Installation Equipment Retrofit Tools Cutting and Deburring Tools BlazeMaster Caulk & Walk Firestop One-step CPVC Cement and Daubers Hangers & Fasteners

Global Strength. Local Expertise. At Your Service. North America 1400 Pennbrook Parkway Lansdale, PA, 19446, USA Tel: +1 215 362 0700 1 800 558 5236 Middle East Internet City, Office Park Building Block D, Floor 3 Dubai, United Arab Emirates +971 4455 0700 Europe Kopersteden 1 Enschede, Overijssel 7547 TJ The Netherlands +31 (0) 53 428 4444 Asia Pacific 2 Serangoon North Avenue 5 #07-01 Singapore 554911 +65 6577 4360 www.tyco-rapidresponse.com 2018 Johnson Controls. All rights reserved. FSP2018004 11/2018