Technical Manual for the Horn - DB1PUL DB1HP UL

Similar documents
Technical Manual for the Horn DB1P UL DB1HP UL

Technical Manual for the Manual Alarm Call Point BG

Technical Manual for the Strobe - SM87 HXB

Technical Manual for the Fire Alarm Call Point - SM87 PBL

FUNCTIONAL SAFETY CERTIFICATE. BG Break Glass Unit

Technical Manual for the Alarm Pull Station PH1

DB1 Range - HORNS - Up to 103 db(a)

DETCON MODEL SW-AV2-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

DETCON MODEL SW-AV1-DV2 Hazardous Duty Class I. Div 2, Multi-tone Alarm Station

FUNCTIONAL SAFETY CERTIFICATE

DB5 Intrinsically Safe Sounder Type DB-5

PRODUCT ATEX IECEx UL ULC CSA Inmetro CUTR CQST ABS SIL IP Rating Page DB7 66 / DB12 66 / DB15 66 / DB1 DB3 DB3V DB3B

PPA Michaël GROSSI - FSCE PR electronics

100 & 120 Series Pressure and Temperature Switches Safety Manual

SIL Safety Guide Series MS Single-Acting Spring-Return Hydraulic Linear Actuators

FUNCTIONAL SAFETY MANUAL

INSTRUCTION MANUAL (ATEX / IECEx)

Safety in the process industry

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Soliphant M with electronic insert FEM52

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

Safety Integrity Verification and Validation of a High Integrity Pressure Protection System to IEC 61511

YO3 - YO4 / YL4 - YO5 / YL5

Functional Safety Solutions

SAFETY INTEGRITY LEVEL MANUAL. IEC and IEC XP95 and Discovery SIL Approved Product Range

United Electric Controls One Series Safety Transmitter Safety Manual

FUNCTIONAL SAFETY OF ELECTRICAL INSTALLATIONS IN INDUSTRIAL PLANTS BY OTTO WALCH

Introduction. Additional information. Additional instructions for IEC compliant devices. Measurement made easy

Overfill Prevention Control Unit with Ground Verification & Vehicle Identification Options. TÜVRheinland

SOUNDERS Up to 113 db(a) EExd, Weatherproof DB1 Range

Manual Alarm Call Points

SAFETY MANUAL. Electrochemical Gas Detector GT3000 Series Includes Transmitter (GTX) with H 2 S or O 2 Sensor Module (GTS)

Technical Report Proven In Use SITRANS P500

Pressure Transmitter cerabar S PMC 731/631 cerabar S PMP 731/635 with ma output signal

Functional safety manual Liquiphant M/S with FEL57 and Nivotester FTL325P

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Digital EPIC 2 Safety manual

MANUAL CALL POINT Intrinsically Safe (EExia), Weatherproof BG3 Range ATEX

Mobrey Magnetic Level Switches

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

Liquiphant S, Nivotester FDL60/61, FTL670

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

Operating Manual MS220DA

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis. PR electronics A/S Rønde Denmark

Differential Pressure Transmitter deltabar S PMD 230/235 deltabar S FMD 230/630/633 with ma output signal

Certification Report of the ST 3000 Pressure Transmitter with HART 6

Operating Manual MS220KA and MSR220KA

INSTRUCTION & SERVICE MANUAL

An optional Ex e terminal chamber is available (see certification section for further details).

Beacons, Lights & Strobes

Session Ten Achieving Compliance in Hardware Fault Tolerance

FMEDA Report. Failure Modes, Effects and Diagnostic Analysis. KFD0-CS-Ex*.54* and KFD0-CS-Ex*.56* Project: X7300

Explosion Proof Combination Signal db (A) / 5 Joule

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

Hazardous Area Communications

Certification Report of the ST3000 Pressure Transmitter

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

Product Manual Standard Asserta Sounder Range

4) Intrinsic Safety Certification

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

X10 Mini, Midi & Maxi

RE-PR3-E-27 3-Phase Panel Mount 27kW

430128A. B-Series Flow Meter SIL Safety Manual

Proservo NMS5- / NMS7-

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis. Rosemount Inc. Chanhassen, Minnesota USA

PRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10

Proof Testing Level Instruments

Hazardous Area Communications

Safety Manual. XNX TM Universal Transmitter. Table of Contents SIL 2 Certificates Overview Safety Parameters

Functional Safety SIL Safety Integrity Level

Failure Modes, Effects and Diagnostic Analysis

Failure Modes, Effects and Diagnostic Analysis

TECHNICAL MANUAL EXPLOSION PROOF SOUNDER/ HORN & BEACON BHB 125/ BHB 150. Scope: EXcite USER MANUAL BHB 125 / BHB 150 Date: Page: Checked by: Rev.

FUNCTIONAL SAFETY: A PRACTICAL APPROACH FOR END-USERS AND SYSTEM INTEGRATORS

Approved by: Document no.: EGT

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK

INSTRUCTION MANUAL (ATEX / IECEx)

FUNCTIONAL SAFETY MANUAL

VTG-32E Spatial Sounder 24Vdc EN54 part 3 approved

HAWK Measurement Systems Pty. Ltd. Centurion CGR Series Safety Manual

OPERATING AND INSTALLATION

Pressure Transmitter cerabar M PMC 41/45 cerabar M PMP 41/45/46/48 with Output Signal ma/hart

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

Failure Modes, Effects and Diagnostic Analysis

Technical Paper. Functional Safety Update IEC Edition 2 Standards Update

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee

TECHNICAL MANUAL EXPLOSION PROOF STATUS LIGHT / LAMP BSL 125 / BSL 150. Scope: EXcite USER MANUAL BSL 125 / BSL 150. Date:

Rosemount Functional Safety Manual. Manual Supplement , Rev AF March 2015

Failure Modes, Effects and Diagnostic Analysis

Flex-Tone Explosionproof Electronic Signals ETH655 & ETH855 SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. Installation

Simply reliable: Process safety from Endress+Hauser

Transcription:

Technical Manual for the Horn - DB1PUL DB1HP UL Please note that every care has been taken to ensure the accuracy of our technical manual. We do not, however, accept responsibility for damage, loss or expense resulting from any error or omission. We reserve the right to make alterations in line with technical advances and industry standards. Eaton MEDC Ltd 2017 07/17

07/17 Eaton MEDC Ltd 2017

GENERAL ARRANGEMENT 2 - HOLES 5 /16" / 8mm 3 1 /8" / 79mm 5 1 /2" / 140mm FIXING CRS 5 1 /2" / 140mm FIXING CRS 3 1 /8" / 79mm 6 7 /8" / 175mm DIA 6 3 /4" / 171mm DIA 6 5 /8" (8 1 /2") / 168mm (216mm) 4 1 /8" (6") / 105mm (152mm) 1 3 /16" 30mm ALL DIMENSIONS IN INCHES AND MILLIMETERS Eaton MEDC Ltd 2017 07/17

SWITCH TONE TONE FREQ/DESCRIPTION SETTING DESCRIPTION 12345 1 Alt Tones 800/970 Hz at 1/4 sec 11111 2 Sweeping 800/970 Hz at 7Hz 11110 Fast Sweep(LF) 3 Sweeping 800/970 Hz at 1 Hz 11101 Med Sweep(LF) 4 * Continuous at 2850 Hz 11100 5 Sweeping 2400-2850 Hz at 7 Hz 11011 Fast Sweep 6 Sweeping 2400-2850 Hz at 1 Hz 11010 7 Slow Whoop 11001 Slow Whoop 8 Sweep 1200-500 Hz at 1 Hz 11000 Din Tone 9 Alt Tones 2400/2850 Hz at 2 Hz 10111 10 Int Tone of 970 Hz at 1 Hz 10110 Back-Up Alarm(LF) 11 Alt Tones 800/970 Hz at 7/8 Hz 10101 12 Int Tone at 2850 Hz at 1Hz 10100 Back Up Alarm(HF) 13 970Hz at 1/4 sec on 1 sec off 10011 14 * Continuous at 970 Hz 10010 15 554Hz for 100mS / 440 Hz for 400mS 10001 French Fire Sound 16 Int 660 Hz 150 ms on 150 ms off 10000 Swedish Fire Alarm 17 Int 660 Hz 1.8 sec on 1.8 sec off 01111 Swedish Fire Alarm 18 Int 660 Hz 6.5 sec on 13 sec off 01110 Swedish Fire Alarm 19 * Continuous 660 Hz 01101 Swedish Fire Alarm 20 Alt 554/440 Hz at 1 Hz 01100 Swedish Fire Alarm 21 Int 660 Hz at 7/8 Hz 01011 Swedish Fire Alarm 22 Int 2850 Hz 150 ms on 100 ms off 01010 Pelican Crossing 23 Sweep 800-970 Hz at 50 Hz 01001 Low Freq Buzz 24 Sweep 2400-2850 Hz at 50 Hz 01000 High Freq Buzz 25 3 970Hz pulses 0.5on/0.5off, 1.5 off 00111 26 3 2850Hz pulses 0.5on/0.5off, 1.5 off 00110 27 Int 3100 Hz 0.32s on / 0.68s off 00101 28 Spare/Customer Tone 00100 29 Spare/Customer Tone 00011 30 Spare/Customer Tone 00010 31 Spare/Customer Tone 00001 32 Spare/Customer Tone 00000 * DB1P Tone 4 is acceptable for Public mode use. DB1P Tones 14 & 19 are acceptable for Private mode use. DB1HP Tones 4 & 14 are acceptable for Public mode use. DB1HP Tone 19 is acceptable for Private mode use 07/17 Eaton MEDC Ltd 2017

3. OPERATION 3.1 The unit is initiated directly from the power source. The DB1P & DB1HP units include two 5-way DIL switches to select any two tones from the list. Use SW2 to select tone 1 & SW1 to select tone 2. 3.2 Single Stage Alarm (d.c. version only) To operate as a single stage alarm, set the appropriate tone using SW1 and connect input wires to TB1 (+ve) (red) and TB5 ( ve) (blue). Loop in and loop out is then TB2 and TB6. To operate in supervisory mode, reverse the voltage between TB1 and TB5 (such that TB1 is -ve and TB5 +ve). Note that there is a diode mounted on the PCB which will inhibit the operation of the sounder in the supervisory (reverse voltage) mode. 3.3 Two Stage alarm (d.c. version only) To operate as a two stage alarm, set the required tones using SW2 for tone 1 and SW1 for tone 2. 3.3.1 Reverse Polarity Set Up Connect input wires to TB1 (+ve) (red) and TB3 ( ve) (black), tone 1 will sound. Reverse the voltage so that TB3 is +ve and TB1 is ve, tone 2 will sound. 3.3.2 Common +ve Set Up Connect input wires to TB1 (+ve) and separate ve s to TB3 and TB5. When TB3 is ve tone 1 will sound, when TB5 is ve tone 2 will sound. 3.4 Single Stage Alarm (a.c. version) When the unit is powered with a.c. only a single stage alarm is available. Tones should be selected using SW1. Connect input wires between TB1 and TB3. Note: In all set ups, loop in and loop out is facilitated by TB2, TB4 and TB6 as appropriate. 4. MAINTENANCE During the working life of the unit, little or no maintenance is required. However, if abnormal or unusual environmental conditions occur due to plant damage or accident etc., then visual inspection is recommended. If a fault should occur, it is recommended that the unit be returned to MEDC for repair. All parts are replaceable. If you have acquired a significant quantity of units, it is recommended that spares are also made available. Please discuss your requirements with the Technical Sales Engineers at MEDC. Eaton MEDC Ltd 2017 07/17

5. CERTIFICATION/APPROVALS Please refer to marking on the unit for specific approval details. USA (USL) Class 1, Zone 1, Groups IIA & IIB. 6. CERTIFIED TEMPERATURE 25 C to +55 C 13 F to +131 F 7. FUNCTIONAL SAFETY - DB1H Introduction The DB1H Sounder has been designed for use in potentially explosive atmospheres and harsh environmental conditions. The marine grade alloy or stainless enclosures are for use offshore or onshore, where light weight combined with corrosion resistance and strength is required. The safety function of the Sounder is to provide a pre-determined audible warning sound when required if the correct voltage is applied to the unit. The DC version of the Sounder is designed to operate on a supply voltage tolerance of +/- 20%, Under No fault (Normal) Operating conditions the DB1 Sounder will provide an audible warning sound when required by the system. Under fault conditions the failure mode of the Sounder is a failure to provide an audible warning sound. For the failure rate associated with this failure mode please refer to the table below. Assessment of Functional Safety This Sounder is intended for use in a safety system conforming to the requirements of IEC61508. UL has conducted a Failure Modes Effect and Diagnostic Analysis (FMEDA) of the DC version of DB1H Sounder against the requirements of IEC 61508-2 using a Proof Test Interval of 8760hrs. The results are shown below and are based on Route 1 H The Sounder is classed as a Type B device 07/17 Eaton MEDC Ltd 2017

DB1H SOUNDER Safety Function of DB1H Sounder: To provide a pre-described audible warning sound when required Summary of Clauses 2/7.4.2 and 2/7.4.4 DB1H Sounder Single Mode (1oo1) DB1H Sounder Redundant Mode (1oo2) Verdict Architectural constraints HFT=0 HFT=1 Type B Safe Failure Fraction (SFF) 65% 65% SIL 1(1oo1) SIL 2 (1oo2) Random hardware failures: [h -1 ] DD DU 6.45E+09 8.87E-08 6.45E+10 8.87E-09 Random hardware failures: [h -1 ] SD SU 0.00E+00 1.59E-07 0.00E+00 1.59E-08 PFD @ PTI = 8760Hrs MTTR = 8 Hrs Average freq. of dangerous failure (high demand-pfh)[h -1 ] Hardware safety integrity compliance Systematic safety integrity compliance Systematic Capability (SC1, SC2, SC3, SC4) Hardware safety integrity achieved 3.89E-04 3.89E-05 SIL 3(1oo1) 8.86E-08 8.86E-09 SIL 3(1oo1) Route 1 H Route 1 s SC2 Limited to: SIL 1 (1oo1) & SIL 2 (1oo2) due to SFF value. Eaton MEDC Ltd 2017 07/17

Conditions of Safe use The following conditions apply to the installation, operation and maintenance of the assessed equipment. Failure to observe these may compromise the safety integrity of the assessed equipment: 1. The user shall comply with the requirements given in the manufacturer s user documentation (This Safety Manual and Technical manual) in regard to all relevant functional safety aspects such as application of use, installation, operation, maintenance, proof tests, maximum ratings, environmental conditions, repair, etc; 2. Selection of this equipment for use in safety functions and the installation, configuration, overall validation, maintenance and repair shall only be carried out by competent personnel, observing all the manufacturer s conditions and recommendations in the user documentation. 3. All information associated with any field failures of this product should be collected under a dependability management process (e.g., IEC 60300-3-2) and reported to the manufacturer. 4. The unit should be tested at regular intervals to identify any malfunctions; in accordance with this safety manual. 5. If the product is used in a redundant installation, both hardware safety integrity and systematic safety integrity for SIL 2 can be achieved. The installation must be such as to ensure sufficient protection against common cause failures and independence from cascading fail lures. Eaton MEDC Ltd, Unit B, Sutton Parkway, Oddicroft Lane, Sutton in Ashfield, United Kingdom NG17 5FB Tel: +44 (0)1623 444444 Fax: +44 (0)1623 444531 Email: MEDCSales@Eaton.com MEDCOrders@Eaton.com Web: www.medc.com MEDC Stock No: TM107-ISS.D 07/17 Eaton MEDC Ltd 2017