AP200 SERIES INTELLIGENT ALARM DEVICES

Similar documents
AP200 SERIES INTELLIGENT ALARM DEVICES

VTG-32E Spatial Sounder 24Vdc EN54 part 3 approved

SOUNDER BASES AND SOUNDER BEACON BASES

Conventional Fire Detection

Xenex Conventional Fire Detection & Alarm System

Opal TM AV Devices. Data Sheet. Benefits

Opal TM AV Devices. Data Sheet. Benefits

Nexus 120 DC Sounder Nexus 120 DC Sounder with 5J Xenon Beacon Nexus 120 DC Sounder with LED Beacon

Intellia Sounder Bases and Sounder Beacon Bases

Sonos-SB Siren/Beacon

PATROL SOUNDERS 110/120 db(a) PA 10 / PA 20

PATROL SOUNDERS 100/105 db(a) PA 1 / PA 5

XP95 Sounder VAD Base

Multi Tone Alarm Sounders A

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

INSTRUCTION MANUAL A105NAPPX & AL105NAPPX APPELLO Alarm Tone and Voice Annunciation Sounder

X10 Mini, Midi & Maxi

PRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10

INSTRUCTION MANUAL A121APPX, AL121APPX & MV121 APPELLO Alarm Tone and Voice Annunciation Sounder

INSTRUCTION & SERVICE MANUAL

CONTROL PANELS. Tech Data Sheet D01688GB1 10/2012 Fire Detection. Control Panels of the FX 3NET (ALC) Fire Detection System

Conventional Audible Visual Range

INSTRUCTION & SERVICE MANUAL

SOUNDER WITH BEACON FOR FIRE DETECTION PANEL

Addressable Detectors & Bases

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

Product Manual Standard Asserta Sounder Range

Optical-Audible Signal Devices

SAFE AREA AUDIBLE & VISUAL SIGNALLING PRODUCTS

VIMPEX BS Evacuation. Fire Alarms EN Banshee. Beacons. FlashDome. Electronic Sounders. Audible Alarm

E2S Datasheet v10a

Bulb Overview DESCRIPTION PART NO. TOTAL VOLTAGE FOR USE WITH: LENGTH(mm) Free-standing Beacons Accessories. Optical Signal Devices

Consultant Specification AGILE Wireless Fire Detection System

Auer - Signal tower ECO Ø70 mm modular

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

Fire Product Catalog

TrueAlert Addressable Notification Appliances

Input/Output Modules Data Sheet

TrueAlert Addressable Notification Appliances

Analogue addressable devices

4) Intrinsic Safety Certification

INPUT / OUTPUT MINI MODULES

INSTRUCTION MANUAL (ATEX / IECEx)

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E

INSTRUCTION MANUAL (ATEX)

L-Series, Emergency Communication Devices

DB5 Intrinsically Safe Sounder Type DB-5

Technical Manual for the Horn DB1P UL DB1HP UL

Fire Signalling. Signalling Solutions

The EN54 Part 2 and 4 Fire System

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

Fire Signalling. Signalling Solutions

EFBW series - BiWire Ultra control panel

YO3 - YO4 / YL4 - YO5 / YL5

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

System 800 Addressable Fire Detection & Alarm System

L-Series, Indoor Strobes and Horn Strobes

Solution F2. Fire Alarm Control Panels one step ahead.

L-Series, Indoor Strobes and Horn Strobes

2000 Series Sensors Installation Guide

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

ATEX. IECEx. culs GOST-R. VdS

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Fire Signalling. Signalling Solutions

Quick Selection Guide Fire Systems LSN Periphery

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

Explosion Proof Combination Signal db (A) / 5 Joule

AU MX Digital Loop Card Installation Instructions

Multiple Status Indicators Series MEXE, MS25, MS35, MS45, MS55

EXTINGUISHING AGENT RELEASE MODULE

TrueAlert Notification Appliances

Addressable and Conventional Fire Protection

Interface and EOL Modules 8

The complete conventional fire warning system

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

Intelligent addressable fire alarm control panel

Synova TM product catalog.

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

Addressable Loop Powered Visual Alarm Devices

MINERVA MZX125 Digital Addressable Fire Detection System

Conventional Fire Alarm System 2014 V1.2

Half-Dome. the Design-Tower. Compact

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

Vega Devices.

IQ8Control C Fire Alarm Panel

EVA-SCM-SCI Sounder Control Module

EN54-23 Beacons & Sounder Beacons

FireNET Plus Wiring Instructions

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

SIGA-CC1 Single Input Signal Module Installation Sheet

Racal-Guardall. Countess. User Instructions. Countess

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

Fire detection and alarm

The new detector from Rafiki

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

4 wire conventional alarm system

Transcription:

Tech Data Sheet D0170GB Fire Detection /01 AP00 SERIES INTELLIGENT ALARM DEVICES Intelligent AP00 series alarm devices for FX fire detection system The intelligent AP00 series alarm devices are used in the FX NET fire detection system. They have been designed to reduce significantly the total cost of installation. Product performance has been optimised to allow the maximum permissible number of devices to be installed on an intelligent loop. The sounders and strobes are installed in exactly the same manner as an intelligent fire detector. Both the wall-mounted and detector base devices use the B01AP detector base. At final commissioning, the sounder or strobe simply twists into the base and the installation is complete. This simple but effective concept significantly reduces the time and cost of installing audible visual warning devices when compared with previous designs. In addition, fire systems designers benefit from the flexibility of being able to change the type of installed device if the protected building is reconfigured by the occupiers. Fault finding is also easy. The suspect device is removed with a simple twist action without having to disconnect any loop wiring; a replacement is then mounted into the base. Wall mount devices Detector base devices WSO-PR-I WSO-PR-N BSO-PP-I BSO-PP-N BSS-PR-I BSS-PR-N NOTE! The products BSS-PR-I and BSS-PR-N are not approved to EN- (Visual Alarm Devices) and must not be used as a visual alarm device or to provide a primary warning notification in fire.

Tech Data Sheet D0170GB Fire Detection Mechanical dimensions Wall mount devices Detector base devices 11 11 WSO-PR-xxx BSO-PP-xxx, BSS-PR-xxx Electrical installation, Base B01AP (+) (-)1 (+) SHIELD Deep Base BPW-E010 and Waterproof Base WPW-E010 FX SLC addressable loop Schneider Electric Fire & Security Oy Sokerilinnantie 11 C, 000 Espoo, Finland Telephone: +8 10 11

Tech Data Sheet D0170GB Fire Detection Mechanical installation Bases/IP rating Mounting Affix B01 AP base to suitably flat wall or ceiling. Terminate the cable to the appropriate terminals. For surface mount wiring the cable can enter the B01 AP base via the break outs provided. Select the appropriate tone and volume settings via the DIP switch. Locate the main assembly on to the base by rotating until it locks into place. Wall mount: B01AP Base (IP1C) Detector base mount: Deep Base BPW-E010 (IP) Waterproof Base WPW-E010 (IP) If the waterproof option is required then the wall gasket must be fitted behind the deep base, and the sealing o-ring fitted after attaching the low profile base. Schneider Electric Fire & Security Oy Sokerilinnantie 11 C, 000 Espoo, Finland Telephone: +8 10 11

Tech Data Sheet D0170GB Fire Detection Anti tamper lock The B01 AP base also includes a tamper resistant feature that when activated prevents removal of the unit without the use of a special tool. This method is consistent with the a tamper feature across all devices using this base. This prevents the device being turned to enable its release. Wall mount: Examples: Address setting 0 7 1 0 8 10 11 1 1 1 1 x10 7 8 1 0 x1 Address setting 1 7 1 0 8 10 11 1 1 1 1 x10 7 8 1 0 x1 Detector base mount: Note! Address setting 01 is used with the FX- LC loop controller. Volume and tone setting (WSO-, BSO- and BSS-) Volume setting is selected by SW and SW7 of the 8 way DIP switch (see table 1). The appropriate tone set is selected by SW1 to of the 8 way DIP switch (see table ). The nd stage tone (related to the 1 st stage tone) is controlled by the fire panel via the protocol. Address setting The address setting in the devices is simply done with two rotary decimal switches, thus having a range of 1 1. In addition the panel can distinguish between detector addresses, I/O-module addresses and sounder addresses, and thus providing a total address capacity per loop of 001 1 and 01, altogether 18 addresses. Two rotary switches are located either side of the dip switch unit. Table 1 7 8 1 0 10 11 1 1 1 x10 SW SW7 Volume setting OFF OFF High OFF ON Medium ON OFF Low ON ON Low OFF = 0, ON = 1 1 ON ON 1 7 8 1 8 Schneider Electric Fire & Security Oy Sokerilinnantie 11 C, 000 Espoo, Finland Telephone: +8 10 11

Tech Data Sheet D0170GB Fire Detection Table DIP setting O=Off/1=On SW 1,,,, No Pattern Nominal Frequency Switching Frequency Description Standard 0,0,0,0,0 1 Alternating /0 Hz French Fire Sound (100ms/00ms) AFNOR NFS -001 7 1,0,0,0,0 Alternating 800/70 1Hz BS8 Pt1 8 0,1,0,0,0 Alternating 800/70 Hz Alternating tone BS8 Pt1 telecoms FP10.1 8 1,1,0,0,0 Alternating 00/00 Hz Alternating High Frquency 10 0,0,1,0,0 Alternating 00/100 Hz Security Alarm 10 1,0,1,0,0 Alternating 88/ Hz 8 0,1,1,0,0 7 Continuous 0 All Clear 1 1,1,1,0,0 8 Continuous 70 BS8 Pt1 0,0,0,1,0 Continuous 100 1,0,0,1,0 10 Continuous 80 HF Continuous 0,1,0,1,0 11 Sweep 00-1000 Raising from 10Hz to 1000Hz in 10 seconds, then 0 seconds at 1000Hz, then falling from 1000Hz to 10Hz in 10 seconds, then 0 seconds at 10 Hz, then repeating. Total period 80 seconds. Gasalarm Tone 1,1,0,1,0 1 Intermittent 0 0.s on,0.s off AS0 alert tone AS0 1 0,0,1,1,0 1 Sweep 00-100 0.s off,.7s off AS0 evacuate tone AS0 1 1,0,1,1,0 1 Intermittent 0.Hz 10ms on, 10ms off Swedish Alarm Tone 7 0,1,1,1,0 1 Intermittent 70 0.8Hz 0.s on, 1s off Intermittent Tone BS8 Pt1 8 1,1,1,1,0 1 Intermittent 70 0.Hz 1s on, Backup alarm LF & 1s off BS8 Pt1 BS8 Pt1 8 0,0,0,0,1 17 Intermittent 80 1Hz Backup alarm HF & BS8 Pt1 nd Tone BS8 Pt1 10 1,0,0,0,1 18 Intermittent 70 1Hz 00ms on, 00ms off BS8 Pt1 BS8 Pt1 8 0,1,0,0,1 1 Intermittent 0 0.Hz (0.s on, 0.s off)*, 1.s off ISO801 1 1,1,0,0,1 0 Continuous 800 Hz 10ms on, 100ms off BS8 Pt1 0,0,1,0,1 1 Sweep 00-100 (0.s on, 0.s off)*, Temporal ISO801 1.s off Evacuation tone Temporal 1 1,0,1,0,1 Sweep 100-00 0.Hz 1s on, Evacuate, DIN tone & 0.01s off PFEER DIN, PFEER 0 0,1,1,0,1 Sweep 00-80 7Hz Fast Sweep Vds Vds 10 1,1,1,0,1 Sweep 00-100 0.sec off.sec on Slow whoop evacuate Netherlands NEN 7 8 0,0,0,1,1 Sweep 800-70 0Hz LF buzz BS8 Pt1 BS8 Pt1 8 1,0,0,1,1 Sweep 800-70 7Hz Fast sweep LF BS8 Pt1 BS8 Pt1 8 0,1,0,1,1 7 Sweep 800-70 1Hz Medium sweep LF buzz BS8 Pt1, BS8 Pt1 VdS 8 Vds 1,1,0,1,1 8 Sweep 00-80 0Hz High frequency buzz 10 0,0,1,1,1 Sweep 00-1000 7Hz Fast whoop 8 1,0,1,1,1 0 Sweep 00-100 - 0.1 Hz rise 1 s, 00 stable s, fall 1s Siren style tone 8 0,1,1,1,1 1 Sweep 800-1000 Hz 8 1,1,1,1,1 Sweep 00-80 1Hz 10 nd Stage Tone Schneider Electric Fire & Security Oy Sokerilinnantie 11 C, 000 Espoo, Finland Telephone: +8 10 11

Tech Data Sheet D0170GB Fire Detection Table Typical current consumption DIP setting O=Off/1=On No Wall mount devises Detector base mount devises SW 1,,,, (WSO) (WSO) (WSO) (BSO/BSS) (BSO/BSS) (BSO/BSS) High Medium Low High Medium Low 0,0,0,0,0 1.0/../.8 1./../.7./. 1.1/. 1,0,0,0,0./8.7./. 1./.7./7.8.0/. 1./. 0,1,0,0,0./8..8/.1 1./.7./7.7.0/. 1./. 1,1,0,0,0./8../. 1.7/.0./7..1/. 1./.8 0,0,1,0,0.7/10.0./. 1.8/.1./8../. 1./. 1,0,1,0,0./../.8 1./.7.0/8../. 1./. 0,1,1,0,0 7.0/8../.8 1./.7.8/8.1./. 1.1/. 1,1,1,0,0 8.8/8.1./. 1./.7./7.8 1./. 1./. 0,0,0,1,0.8/8.1./. 1./.8./7.8.0/. 1./. 1,0,0,1,0 10./8..7/.0 1./.8./7.8.1/. 1./.7 0,1,0,1,0 11./8.8./.8 1./.7.0/8..1/. 1./.7 1,1,0,1,0 1./../. 1.1/../8..1/. 1.0/. 0,0,1,1,0 1 10./1.7./. 1.7/.0.1/1..0/. 1./. 1,0,1,1,0 1.0/8../.7 1./..7/8.0./. 1.1/. 0,1,1,1,0 1.8/8.1./. 1./.7./7.7 1./. 1./. 1,1,1,1,0 1.8/8.1./. 1./.7.8/8.1 1./. 1./. 0,0,0,0,1 17./8..7/.0 1./.8./7.8.1/. 1./.7 1,0,0,0,1 18.8/8.1./. 1./.7./7.8 1./. 1./. 0,1,0,0,1 1./7..1/. 1./../7.7 1./. 1./. 1,1,0,0,1 0./8../. 1./../7..0/. 1./. 0,0,1,0,1 1 11.1/1..1/. 1./. 10./1.8./.8 1./. 1,0,1,0,1 10./1../. 1.7/.0./1..8/.1 1./. 0,1,1,0,1.0/8../. 1./..8/8.1./.7 1.7/.0 1,1,1,0,1 10./1../.8 1.7/.0.0/1..0/. 1./. 0,0,0,1,1.0/7../. 1./..7/7.0 1./. 1./. 1,0,0,1,1./7.8./.8 1./.7./7..0/. 1./. 0,1,0,1,1 7.1/8..8/.1 1./.7./7..0/. 1./.7 1,1,0,1,1 8./8../. 1.8/.1./7../.7 1./. 0,0,1,1,1./8.7./.8 1./..8/8.1 1./. 1./. 1,0,1,1,1 0 10.1/1../.7 1.7/.0./1..8/.1 1./. 0,1,1,1,1 1./8..7/.0 1./.7.8/8.1.1/. 1./.7 1,1,1,1,1./8../. 1./..0/8../.7 1./. Note! For Isolated variants add 0.1mA to high, medium, low values above. Schneider Electric Fire & Security Oy Sokerilinnantie 11 C, 000 Espoo, Finland Telephone: +8 10 11

Tech Data Sheet D0170GB Fire Detection 7 Technical data Wall Mount Devices WSO-PR-xxx Description Sounder Operating voltage 1 to VDC(isolation) (VDC typical) 1 to VDC (non isolation) (VDC typical) Quiescent current 0µA Max current consumption (sound) (isolation).77ma (High Volume Tone 8@ V) Max current consumption (sound) (non isolation).8ma (High Volume Tone 8@ V) Sound Output to EN- db(a)±db (High Volume Tone 8@ V) Operating Temperature - to 70 C Relative Humidity Up to % (±%) non-condensing IP Rating IPC (with B01 AP base) IP (with Deep base BPW-E010) IP (with Waterproof base WPW-E010) Colour Red Weight 7g Terminal Size max.mm Number of Tones Volume Setting High, Medium, Low Product codes WSO-PR-I, isolation FFS071177 WSO-PR-N, non isolation FFS071178 Bases IP rating Product codes B01AP IP1 FFS071000 BPW-E010 IP FFS07117 WPW-E010 IP FFS07117 Schneider Electric Fire & Security Oy Sokerilinnantie 11 C, 000 Espoo, Finland Telephone: +8 10 11

Tech Data Sheet D0170GB Fire Detection 8 Detector Base Mount Devises BSO-PP-xxx BSS-PR-xxx Description Sounder Sounder Strobe Operating voltage 1 to VDC (non isolation) (VDC typical) 1 to VDC (isolation) (VDC typical) Quiescent current 0µA Max current consumption (sound).7ma 8.0mA (isolation) (High Volume Tone 8@ V) Max current consumption (sound) (non isolation) (High Volume Tone 8@ V).mA 7.8mA Sound Output to EN- db(a)±db (High Volume Tone 8@ V) Beacon Flash Rate N/A 1 Hz Operating Temperature - to 70 C Relative Humidity Up to % (±%) non-condensing IP Rating IPC (with B01 AP base) IP (with Deep base BPW-E10) IP (with Waterproof base WPW-E10) Colour White Weight 1g 00g Lens Colour Red Terminal Size max.mm Number of Tones Volume Setting High, Medium, Low Product codes BSO-PP-I, isolation BSO-PP-N, non isolation FFS071171 FFS07117 BSS-PR-I, isolation BSS-PR-N, non isolation FFS07117 FFS07117 NOTE! The products BSS-PR-I and BSS-PR-N are not approved to EN- (Visual Alarm Devices) and must not be used as a visual alarm device or to provide a primary warning notification in fire. Bases IP rating Product codes B01AP IP1 FFS071000 BPW-E010 IP FFS07117 WPW-E010 IP FFS07117 Schneider Electric Fire & Security Oy Sokerilinnantie 11 C, 000 Espoo, Finland Telephone: +8 10 11