R410A. High Performance Air-Conditioning. FD series. Inverter Packaged Air-Conditioners

Similar documents
FDUA/M Series Inverter Ducted Air Conditioners. MHIAA is proudly sponsoring Monika s Doggie Rescue

DX Range. Proudly supporting

for Light Commercial Use

VRF inverter multi-system Air-Conditioners. 50Hz 13KX02E EU/EEA

Heat Pump Air Conditioning Systems

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

R410A. High Performance Air-Conditioning. SR series. Inverter Residential Air Conditioners

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

Energy-saving operation

INVERTER DUCTED SYSTEMS

Inverter Ducted Air Conditioners

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

DC Inverter Smart VRF Products(R410A)

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

Technology that works fast. Inverter Ducted Systems

Inverter Ducted Air Conditioners

JUNE & 3-4 Head Multi System

2 &3-4 Head Multi System

MiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL

Product 2012Catalogue. People

Inventor of the Inverter Digital Inverter System

DESIGN & TECHNICAL MANUAL

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

3 rd Generation of VRV. The professional solution for your professional project

Integrated VarIable refrigerant flow ahu/pau (r410a)

Technical Guide. Multizone: Multi-Split Type Heat Pump Systems

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

DUCTED. SYSTEMS Enhanced for superior comfort and smart energy management by AirTouch 3. fordanddoonan.com.au 1800 AIR CON

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

GUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date.

Product Brochure 2017

DESIGN & TECHNICAL MANUAL

Product Brochure Smart Power. Low Profile Ducted

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool

AIR CONDITIONING REVERSE-CYCLE INVERTER

LIGHT COMMERCIAL RANGE Inverter heat pumps suitable for both homes and commercial premises

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

250mm dia straight pipe length SP4 SP3. Air volume

TECHNICAL DATA & SERVICE MANUAL

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Ducted Air Conditioning

Super. Digital Inverter. Inverter Air Conditioning for Light Commercial Use

KSD-35 DR11 KUE-35 DVN11

Blending Commercial and Residential. MiNi VRF

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

DAIKIN Modular Inverter Air Cooled Chiller

Just feel well. 2017/2018 Air conditioning

Ducted inverter reverse cycle air conditioning

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

SUBMITTAL DATA: PEAD-A12AA7 & PUZ-A12NKA7(-BS) 12,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A12NKA7

Now with WiFi as standard Find out more at

11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER Split system, Air cooled cooling only type

MRVIII-S. 007 Features & Benefits 017 MRVIII-S Outdoor

DESIGN & TECHNICAL MANUAL

WHY A MHI HEAT PUMP?

360 round flow, ensuring uniform airflow distribution across the room. Independent louvre control allows each louvre to be set at the desired angle

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOU9RLS2H AOU12RLS2H AOU15RLS2H

Catalogue 2010 Residential Light Commercial Commercial

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

SERVICE MANUAL VRF INVERTER MULTI-SYSTEM AIR-CONDITIONERS. Manual No. '14 KX-SM-202 (OUTDOOR UNIT)

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

Inverter Wall Mounted Series

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION

Comfort. Health Clean. Saving. The new era in air conditioning. Multi-Split Systems

USER S MANUAL HSC-14/18/24/24A

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

PUHZ-SHW140YHA PUHZ-SHW230YKA

HI-WALL SPLIT SYSTEMS

Ducted Air Conditioning

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Cassette type Duct type Ceiling type INVERTER AO* G45LETL AO* G54LETL

A GUIDE TO COMFORT EXCLUSIVELY DISTRIBUTED BY TEMPERZONE AUSTRALIA

Ceiling Mounted Cassette ( Round Flow with Sensing ) Type

Ductless Split Systems Concealed Duct Heat Pumps

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

Owner s Manual Super-Slim Four-Way Cassette

Air Conditioner CONTENTS

Cozy Hi Wall Inverter Air Conditioner

RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS

Compact 4-way Cassette ( ) Type

Small VRF system. for light commercial and home use SERVICE MANUAL

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL AW22AL AW28AL AW38AL

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

AIR CONDITIONING AGAIN, AGAIN & AGAIN ONLY PANASONIC GETS 5 STARS #AIRTHATMOVESYOU

Instruction manual Harmo PAC ZVWX1017/1022/1032/1041/1055/1056/1061

Residential and Light Commercial Ductless Systems Catalog

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

Transcription:

R410A High Performance Air-Conditioning FD series Inverter Packaged Air-Conditioners

Individual flap control system According to room temperature conditions, four directions of air flow can be controlled by individual flap as preferred. Individual flap control is available even after installation. Individual Flap Control System The Thinnest Design High Efficiency Index Our inverter technology 4 Product line up 7 FDT cassette 8 FDTC compact cassette 10 FDU ducted 12 FDUM ducted 14 FDEN ceiling suspended 16 Outdoor unit 18 Controls system 19 Outdoor unit dimensions 22

Ceiling Cassette -4way- units FDT For the person who is far away from the indoor unit For when one person feels hot and the other cold Can cool both the kitchen and the guests

High Efficiency QUICK CONTROL & HIGH EFFICIENCY DC PAM inverter An inverter system has a number of advantages over a constant speed system. It s variable speed compressor outputs can ensure quick cooling or heating after start up and attains a set temperature more quickly. The air conditioner can slow down the compressor speed to save energy whilst keeping comfortable conditions. The compressor is DC motor driven so it provides higher performance. DC compressor motor Motor Efficiency(%) Magnet Motor Improving Improving Induction Motor DC PowerActiveModule PAM INVERTER Low Revolution speed High New Inverter Control (Vector control) New Inverter Control has applied the new advanced technology of Vector control enabling:- Smooth operation from low to high speed Smooth Sine Voltage Wave form is achieved Energy effi ciency has improved in low speed range DC PAM INVERTER Room Temp. Time CONVENTIONAL INVERTER Room Temp. Time PAM PWM Set Temp. Set Temp. Even Temperature DC PAM INVERTER Rated Capacity ON Compressor (rps) CONVENTIONAL ON OFF Rated Capacity OFF Compressor (rps) Utmost comfort and energy efficiency achieved with large output power and control optimisation Less advanced technology does not address the ON/OFF cycle issue. Wide Operation Range Heating and cooling operations are possible at an outdoor temperature as low as 15 C. Our new advanced technology has improved the heating and cooling operation range. Units can be installed when heating or cooling operation is required at low ambient conditions down to -15 C. -15 C Heating +21 C -15 C Cooling +46 C -20-10 0 10 20 30 40 50 4 High Performance Air Conditioning

High Efficiency New remote control RC-E4 New remote control for all indoor units Non-polar 2 core wiring now used. Installation is easier. Previous 3-core New 2-core Individual flap control system Four directions of air flow can be arranged by individual flap control. Our new outlet design enables the right amount of air to reach all corners of the room. Pressure loss caused by airflow in the indoor unit has been reduced. The thinnest design The heat exchanger has been re-designed and energy efficient DC fan motors have been used to enable us to reduce the height of the indoor unit. Heat exchanger piping modification and design increases heat transfer efficiency. FDT60~71 270mm 246 mm 9% reduction!! FDT125~140 Shape of Heat exchanger 365mm Current New 298 mm 18% reduction!! Packaged Air Conditioners 5

High Efficiency High performance and energy efficiency are achieved at the same time by an increase in the heat exchanger capacity and by using DC fan motors. Cool Only Wall-split System - Non Inverter Compact design Size reduction and high efficiency performance of the DC twin rotary compressor The DC twin rotary compressor can operate at speeds as high as 120 rps to achieve the required capacity. Vector control and has provided the optimum compressor control. Starting current has improved significantly and vibration has been reduced. Height at 440 mm Outside diameter of shell ø185mm Former compressor Reduction in height by 22.3% Reduction in volume by 44.1% ø133mm Height at 342mm New model DC rotary compressor Improved efficiency of heat exchanger Re-designing the fins to a straight shape has reduced the pressure loss of the air flow in the heat exchanger. A new surface treatment on the fins has enhanced the frost resistance capacity compared to former models. A high speed fan motor has increased the airflow which allows cooling capacity to be maintained even at high outdoor air temperatures. DC fan motor The outdoor fan motor has improved efficiency by 60% compared to former models. Former model New model CnT terminal A dry contact is fitted to each indoor unit which is used when a signal output is required. The CnT simpliflies connection to BMS, home automation systems and external timers CnT XR1 XR2 XR3 XR4 XR5 XR1~5 : approx. DC12v XR5 XR1 XR2 XR3 XR4 common output1 (run) output2 (heat) output3 (comp on) output4 (alarm) in put Power source New outdoor units SRC50/60ZIX-S SRC50/60ZIX-S is common for both outdoor units of SRK50/60ZIX-S wall split systems, and 5.0 & 5.6kW of Inverter Packaged Air-Conditioners. The installation procedure is the same. 6 High Performance Air Conditioning

Product line up Cool Only Wall-split System - Non Inverter R410A Model 5.0 6.0 7.1 10.0 12.5 14.0 FDT Caseette FDTC Mini Cassette HEAT PUMP DC INVERTER FDU Ducted FDUM Ducted FDEN Under Ceiling Packaged Air Conditioners 7

Unit Ceiling Cassette - 4way FDT FDT 60/71/100/125/140 Wireless remote control Wired remote control RCN-T-36W-E (Option) RC-E4 (Option) RCH-E3 (Option) Outline drawing (Unit:mm) Model FDT 60,71 Model FDT 100,125,140 Installation Detachable covers at each corner allows for easy alignment and balance. The panel does not need to be removed. Installation time is reduced. Infrared control For wireless control simply insert the infra-red receiver kit on the corner. wireless remote control RCN-T-36W-E 8 High Performance Air Conditioning

Cool Only Wall-split System - Non Inverter Easy checking of drain pan To check the drain pan simply remove the corner lid. 700mm Drain Pump The drain pump can discharge up to 700mm from the ceiling surface. Flexible hose less than 700mm FDT Series FDT60ZIXVD FDT71VNVD FDT100VNVD FDT125VNVD FDT140VNV FDT60VD FDT71VD FDT100VD FDT125VD FDT140V SRC60ZIX-S FDC71VN FDC100VN FDC125VN FDC140VN Power Supply Outdoor Unit 1 phase 230V 50Hz Capacity 5.6 (2.8~6.3) 7.1 (3.2~8.0) 10.0 (4.0~11.2) 12.5 (5.0~14.0) 14.0 (5.0~14.5) kw Heating H1 6.7 (3.1~7.1) 8.0 (3.6~9.0) 11.2 (4.0~12.5) 14.0 (4.0~16.0) 16.0 ( 4.0~16.5) Input 1.57 1.90 2.76 4.05 4.98 kw Heating H1 1.85 2.07 2.74 3.77 4.57 Energy Label Cooling 2.5 2 1.5 1 Stars Heating 2.5 2.5 3 2 Grandfathered EER 3.56 3,73 3.62 3.08 2.81 COP Heating H1 3.62 3.86 4.08 3.71 3.5 Current 7.0 8.3 12.1 17.7 22.0 Amp Heating H1 8.2 9.0 12.0 16.6 20.2 Recommended Circuit Breaker Amp 16 20 32 Sound Pressure Level (JIS C9612) db 46-33-31-30 46-35-33-31 51-40-37-35 51-42-40-37 51-43-41-38 48 49 51 Sound Power Level (JIS C9612) Outdoor db(a) 65 63 70 72 73 Airfl ow l/s 466-300-266-233 466-350-316-283 616-450-400-333 616-500-450-383 616-500-450-383 Panel T-PSA-3AW-E mm 35 950 950 External Dimensions (HXWXD) 246 840 840 298 840 840 mm Outdoor 640 800 290 750 968 340 845 970 370 Net Weight Unit 24 Panel 5.5 Unit 27 Panel 5.5 kg Outdoor 43 60 81 Liquid line Ø6.35 (1/4 ) Ø9.52 (3/8 ) Refrigerant Piping Gas line mm(in) Ø12.7 (1/2 ) Ø15.88 (5/8 ) Connection Method Flare Refrigerant R410A Pre-charged Amount kg 1.4 2.95 3.8 m 15 30 Maximum Piping Length m 30 50 Controller RC-E4 or RCN-T-36W-E For additional information please reference 10.PAC.DB.142A Sound pressure level indicates the value in an anechoic chamber Packaged Air Conditioners 9

Unit Cassette - 4way Compact (600x600mm) Cool Only Wall-split System - Non Inverter FDTC FDTC 50 Wireless remote control Wired remote control RCN-TC-24W-ER (Option) RC-E4 (Option) Outline drawing (Unit:mm) 10 High Performance Air Conditioning

Clearer airflow Cool Only Wall-split System - Non Inverter The new shape and angle of the louver directs the air current away from the ceiling reducing ceiling stains. Infrared control High Efficiency For wireless control simply insert the infra-red receiver kit on the corner. Compact design Height dimension is only 248mm Panel size is only 700x700mm. The indoor unit is 570x570mm ideal for suspended ceilings. 248 Opening for exit wiring Installation Wired or infra-red wireless remote control option. Light weight only18.5kg 600mm Drain Pump The drain pump can discharge up to 600mm from the ceiling surface. Flexible hose 600mm FDTC Series FDTC50ZIXVD FDTC50VD SRC50ZIX-S Power Supply Outdoor Unit 1phase 230V 50Hz Capacity Input Energy Label 5.0 (2.2~5.6) kw Heating H1 5.4 (2.5~6.3) 1.56 kw Heating H1 1.45 Cooling 2 Stars Heating 2.5 EER 3.205 COP Heating H1 3.724 Current 6.9 Amp Heating H1 6.4 Recommended Circuit Breaker Amp 16 Sound Pressure Level (JIS C9612) 47-42-36-32 db Outdoor 47 Sound Power Level (JIS C9612) Outdoor db(a) 62 Airfl ow l/s 225-191-150-133 Panel TC-PSA-25W-E mm 35 700 700 External Dimensions (HXWXD) Net Weight Refrigerant Piping Refrigerant R410A 248 570 570 mm Outdoor 640 800 290 Unit 15 Panel 3.5 kg Outdoor 43 Liquid line Ø6.35 (1/4 ) mm(in) Gas line Ø12.7 (1/2 ) Connection Method Pre-charged Amount Flare kg 1.4 m 15 Maximum Piping Length m 30 Controller For additional information please reference 10.PAC.DB.142A Sound pressure level indicates the value in an anechoic chamber RC-E4 or RCN-TC-24W-ER Packaged Air Conditioners 11

Unit Ducted - Medium Static Pressure FDU RCH-E3 (Option) Wired remote control FDU71/100/125/140 RC-E4 (Option) RCN-KIT3-E Return air option Outline drawing (Unit:mm) FDU71 FDU100,125,140 Quiet, Lightweight and Compact The FDU71 noise level is only 37dB on low fan. Weight is only 40kg and height 297mm. In addition a 600mm drain pump is mounted in all models. The indoor unit is concealed in the ceiling making it the ideal choice for homes and commercial premises. Height 297mm 12 High Performance Air Conditioning

High Efficiency FDU Series FDU71VNVD FDU100VNVD FDU125VNVD FDU140VNV FDU71VD FDU100VD FDU125VD FDU140V FDC71VN FDC100VN FDC125VN FDC140VN Power Supply Outdoor Unit 1 phase 230V 50Hz Capacity 7.1 (3.2~8.0) 10.0 (4.0~11.2) 12.5 (5.0~14.0) 14.0 (5.0~14.5) kw Heating H1 8.0 (3.6~9.0) 11.2 (4.0~12.5) 14.0 (4.0~16.0) 16.0 (4.0~16.5) Input 2.08 2.88 4.04 4.95 kw Heating H1 2.21 2.99 3.79 4.43 EER 3.41 3.47 3.09 2.82 COP Heating H1 3.61 3.74 3.69 3.61 Current 9.2 12.7 17.8 21.7 Amp Heating H1 10.2 13.1 16.6 19.5 Recommended Circuit Breaker Amp 20 32 Sound Pressure Level (JIS C9612) Hi :41 Lo : 37 Hi : 42 Lo : 37 Hi : 43 Lo : 38 Hi : 43 Lo : 38 db Outdoor 48 49 51 Sound Power Level (JIS C9612) Outdoor db(a) 63 70 72 73 Airfl ow l/s Hi : 333 Lo : 283 Hi : 566 Lo : 450 Hi : 700 Lo : 558 External Static Pressure Pa 60/130 @ 333 l/s 60/130 @ 566 L/S 60/130 @ 700 L/S External Dimensions (HXWXD) 297 850 650 350 1,370 650 mm Outdoor 750 968 340 845 970 370 Net Weight 40 63 kg Outdoor 60 81 Liquid line Ø9.52 (3/8 ) mm(in) Refrigerant Piping Gas line Ø15.88 (5/8 ) Connection Method Flare Refrigerant R410A Pre-charged Amount kg 2.95 3.8 m 30 Maximum Piping Length m 50 Controller RC-E4 For additional information please reference 10.PAC.DB.142A Sound pressure level indicates the value in an anechoic chamber Packaged Air Conditioners 13

Unit Ducted - Medium Static Pressure FDUM Wired remote control RCN-KIT3-E RC-E4 (Option) RCH-E3 (Option) Point 1 Adaptable Point 2 600mm Drain Pump Selectable static pressure and Flexible duct design with selectable air suction (direct suction /duct suction) can meet a wide range of installations. Static pressure Pa model 50/60 Standard 50 Max 85 Drain can be discharged upwards by 600mm from the ceiling surface. It allows a piping layout with a high degree of freedom depending on the installation location. Flexible hose less than 600mm Outline drawing(unit:mm) Model FDUM50 Models FDUM60 14

Unit High Efficiency FDUM Series FDUM50ZIXVD FDUM60ZIXVD FDUM50VD FDUM60VD SRC50ZIX-S SRC60ZIX-S Power Supply Outdoor Unit 1 phase 230V 50Hz 5.0 (2.2~5.6) 5.6 (2.8~6.3) Capacity kw Heating H1 5.4 (2.5~6.3) 6.7 (3.1~7.1) 1.52 1.86 Input kw Heating H1 1.41 1.96 EER 3.28 3.01 COP Heating H1 3.82 3.41 6.7 8.2 Current Amp Heating H1 6.3 9 Recommended Circuit Breaker Amp 16 35-34-31-28 38-34-31-28 Sound Pressure Level (JIS C9612) db Outdoor 47 48 Sound Power Level (JIS C9612) Outdoor db(a) 62 65 Airfl ow l/s 233-216-200-183 300-266-250-233 External Static Pressure Pa 85 @ 233 l/s 85 @ 300 l/s 299 750 635 299 950 635 External Dimensions (HXWXD) mm Outdoor 640 800 290 34 40 Net Weight kg Outdoor 43 Liquid line Ø6.35 (1/4 ) mm(in) Refrigerant Piping Gas line Ø12.7 (1/2 ) Connection Method Flare kg 1.4 Refrigerant R410A Pre-charged Amount m 15 Maximum Piping Length m 30 Controller RC-E4 For additional information please reference 10.PAC.DB.142A Sound pressure level indicates the value in an anechoic chamber Packaged Air Conditioners 15

Unit Ceiling Suspended FDEN Wireless remote control Wired remote control RCN-E1R (Option) RC-E4 (Option) Outline drawing (Unit:mm) 24 a (Suspension bolts pitch) 24 173 e 5 d 290(Suspension bolts pitch) Holes for suspension bolts (M8 to M10X 4pcs.Not included) 135 410 145 68 52 Liquid piping Gas piping 40 b 40 Drain hole connection(1) (VP20) 76 Air inlet grille c Gas piping Drain hole connection(1) (VP20) Air outlet Indication board 308 75 Liquid piping 110 135 690 10 195 235 271 Note(1) The slope of drain piping inside the unit is able to take incline of 10mm. 53 53 109 Space for installation and service Drain hole connection(1) (VP20) Dimension Table model a b FDEN100VNV 1572 1540 c 1620 d 255 e 250 100 or more or more 300 Obstacles 150 or more 5 or more 16 High Performance Air Conditioning

High Efficiency Installation Compact design Up Right Rear Height 250mm Refrigeration piping can be set in three directions and the drain pipe arranged in two directions making installation easier. The unit is serviceable from the bottom. The FDE height starts at just 250mm and weighs just 63kg s allowing for quick and easy installation. The unit is compact and fits neatly on the ceiling. The modern design with rounded corners lends style to the room. FDEN Series FDEN100VNVD FDEN100VD FDC100VN Power Supply Outdoor Unit 1 phase 230V 50Hz 10.0 (4.0~11.2) Capacity kw Heating H1 11.2 (4.0~12.5) 2.85 Input kw Heating H1 2.97 Cooling 2 Energy Label Stars Heating 2.5 EER 3.508 COP Heating H1 3.771 12.5 Current Amp Heating H1 13.0 Recommended Circuit Breaker Amp 32 P-Hi : 46 Hi : 44 Me : 41 Lo : 39 Sound Pressure Level (JIS C9612) db Outdoor 49 Sound Power Level (JIS C9612) Outdoor db(a) 70 Airfl ow l/s P-Hi :466 Hi :433 Me :383 Lo :350 250 1,620 690 External Dimensions (HXWXD) mm Outdoor 845 970 370 63 Net Weight kg Outdoor 81 Liquid line Ø9.52 (3/8 ) mm(in) Refrigerant Piping Gas line Ø15.88 (5/8 ) Connection Method Flare kg 3.8 Refrigerant R410A Pre-charged Amount m 30 Maximum Piping Length m 50 Controller RC-E4 or RCN-E1R For additional information please reference 10.PAC.DB.142A Sound pressure level indicates the value in an anechoic chamber Packaged Air Conditioners 17

Outdoor Unit OUTDOOR UNIT (4.0-14.0kW) SRC50ZIX-S SRC60ZIX-S FDC71VN FDC100VN FDC125VN FDC140VN Installation workability Enhanced installation workability thanks to the extended pipe length one of the longest levels in the industry and pre-charged refrigerant. Point 1 Piping length 50m Piping length can be extended up to 50m for single type, which allows wider design flexibility. Height difference (Outdoor>indoor) 5.0 ~ 6.0kW 20m 7.1~14.0kW 30m Piping length 5.0 ~ 6.0kW : 30m 7.1~14.0kW : 50m Point 2 Refrigerant pre-charged piping length extending to 30m Refrigerant pre-charged piping length extends up to 30m. (5.0 ~ 6.0kW: up to15m) This eliminates the need to add refrigerant on site, which sets it free from trouble of excessive or insufficient charging of refrigerant, and allows carrying out the installation smoothly. 18

Control System (Individual High Efficiency Control) Control Systems [Individual control] Remote Control line up indoor unit remote control indoor unit Cool Only Wall-split System - Non FDT Inverter wired Wired remote control with weekly timer (option) RC-E4 all models RC-E4 RCH-E3 wireless FDTC FDUM, FDU FDEN remote control RCN-T-36W-E RCN-TC-24W-ER RCN-KIT3-E RCN-E1R Run hour meters to facilitate maintenance checking RC-E4 stores operation data when an anomaly occurs and indicates the error on the LCD. It also displays cumulative operation hours of the air conditioner and compressor since commissioning. Weekly timer function as standard The RC-E4 controller enables extensive access to service and maintenance technical data combined with easy to use functions and a clear LCD display. RC-E4 provides (as a standard feature) a weekly timer, which allows one-week operation schedules to be registered. A user can specify up to four times a day to start/stop the air conditioner. (Temperature setting is also possible with the timer). Timer operation Room temperature controlled by the remote control sensor The temperature sensor is housed in the top section of the remote control unit. This arrangement has improved the sensitivity of the remote control unit s sensor, which permits more finely controlled air conditioning. Changeable set temperature ranges RC-E4 allows the upper and lower limits of a set temperature range to be specified separately. By adjusting a set temperature range, you can ensure energy saving air conditioning by avoiding excessive cooling or heating. Upper limit Lower limit Changeable range 20~30 C(effective for heating operation) 18~26 C(effective for non-heating operation) Simple remote control (option) RCH-E3 (wired) Considering specialized usage in hotel rooms, control buttons are limited only to minimum required functions such as ON/OFF, mode, temperature setting and fan speed. It is really simple and easy to use. Up to 16 units It can control up to 16 units individually by pressing the AIR CON No. button. AUTO restart This function allows starting the air conditioner automatically when power supply is restored after power failure or by turning on the power switch. Wireless remote control (option) For wireless control simply insert the infrared receiver kit on a corner of the panel. RCN-T-36W-E, RCN-TC-24W-ER RCN-KIT3-E RCN-E1R Thermistor (option) SC-THB-E3 In case the sensor in the indoor units or the remote control sensor can not sense the room temperature correctly, or individual remote control in each room is not required but only a censor is required (as when center control system is in place), install SC-THB-E3 at a proper place in the room. 19

Control System WIRED Control (RC-E4) The RC-E4 control allows access to service and maintenance data and easy to use comfort functions. Improved Functionality Weekly timer function as standard RC-E4 provides a 7day 24hr timer which allows programming of weekly operating schedules to be registered. The user can specify up to four times a day to start / stop the air conditioner. Temperature setting is also possible with the timer. Run hour meters to facilitate maintenance checking RC-E4 stores operation when an anomaly occurs and indicates the error on the LCD. It also displays cumulative hours of the air conditioner and compressor since commissioning. Room temperature controlled by the remote control sensor The temperature sensor is located in the top section of the remote control unit. This has improved the sensitivity of the remote controls heat sensor and permits more finely controlled air conditioning. Changeable set temperature range The RC-E4 allows for the upper and lower limits of a set temperature range to be specified separately. By adjusting the set temperature range you can ensure energy saving air conditioning by avoiding excessive heating or cooling. Upper limit Lower limit Changeable range 20~30 C (effective for heating operation) 18~26 C (effective for non-heating operation) 20 High Performance Air Conditioning

Control System Control System SUPERLINK- Control System SUPERLINK-II KX6 series SC-SL1N-E RAC series (SRK50/60ZHX-S) SC-BIKN-E SC-ADN-E SC-SL2N-E SC-ADN-E SC-ADN-E SC-SL1N-E Central Control SC-SL2N-E SC-SL3N-AE/BE Start/stop control of up to 16 indoor units is possible either individually or collectively. With simple operations, you can effect centralized control. Centralized control of up to 64 indoor units. It can allow connection with a weekly timer without using any interface. Easy operation realized with a large color LCD and touch panel. Up to 128 indoor units can be controlled, when three SUPERLINK-II systems are connected. PC windows central control SC-WGWN-A/B* (SC-WGWN-B is with electric power calculation function) BMS interface unit SC-BGWN-A* SC-LGWN-A* (BACnet gateway) (LonWorks gateway) Up to 96 groups (64 indoor unit x 2 SUPERLINK-II systems) are controlled through an internet browser. Up to 96 groups (64 indoor unit x 2 SUPERLINK-II systems) are controlled centrally from a BMS. Up to 96 indoor units (48 indoor unit x 2) are linked as an open network. Centrally controlled through LonWorks. * Additional engineering service cost etc. is required. Packaged Air Conditioners 21

Control System SUPERLINK E BOARD (SC-ADN-E) SUPERLINK E BOARD (SC-ADN-E) This board is used when conducting control of the single package (wired remote control unit) 1-type series using a network option (SC-SL1N-E, SC-SL2N-E, etc). (1) Functions (a) Transmits the settings from the network option to the indoor units. (b) Returns the priority indoor unit data in response to a data request from the network option. (c) Inspects the error status of connected indoor units and transmits the inspection codes to the network option. (d) A maximum of 16 units can be controlled (if in the same operation mode). (2) Wiring connection diagram LED2 ON OFF Master/Sub address SL E board LED3 Run Abnormal SW3 SW1 SW2 A B X Y Network address setting switches [000]-(127) Blue Blue Black White Connected to the terminals for Superlink signal lines MVVS 0.75-1.25mm 2 A B X Y Connected to the remote controller terminals (no polarity) (the length should be 600 m or shorter) 200 m or shorter 300 m or shorter 400 m or shorter 600 m or shorter 0.5 mm 2 x 2 cores 0.75 mm 2 x 2 cores 1.25 mm 2 x 2 cores 2.0 mm 2 x 2 cores Basic Connections Outdoor unit Internal/external Crossing unit X Y Plural Controls by Multiple Remote Controls. Mixture of Multiple Units Outdoor unit Internal/external Crossing Inside Inside Inside Inside SL E Board X Y A B Network options A B Remote control X Y SL E Board Network options R R Transmit the information of plural Master units to the network. Transmit the abnormalities of the Slave units to the network. Setting the plural Master/Slave units with the dip SW of the printed circuit board. Setting the Master/Slave remote controls with the dip SW of the remote control board. Plural Controls by Multiple Remote Controls. Mixture of Multiple Units Without Remote Control Wireless Kit Outdoor unit Internal/external Crossing Inside Inside Inside Inside Outdoor unit Internal/external Crossing Inside Inside Inside Outdoor unit Internal/external Crossing Inside Inside Outdoor unit Internal/external Crossing Inside Inside SL E Board Network options R R SL E Board R R Set up 000 to 127 using address switch on the SL E board. SL E Board Network options Set the SL E board dip SW to Master SW3-1 ON. The network option SLA-1-E, SL1N-E is not allowed (This will disturb switching of the operation mode) SL E Board Network options Wireless Kit Wireless remote control SRC 50ZIX-S, 60ZIX-S (unit:mm) Terminal block 148.4 33.5 Intake L2 Intake outlet L3 L1 L4 Service space 640 Check joint B 290 12.4 43.5 83.5 D 50.6 327.3 12 327.3 89 510 201 800 17.9 93 42.5 E 71.2 24.3 312.5 14.8 351.6 Mark A B D E 40 A 40 Dimensions L1 L2 L3 L4 Item Refrigerant gas side pipe connection tap Refrigerant liquid side pipe connection tap Drain discharge port Anchor bolt hole Examples of installation Open 100 100 250 280 75 80 Open ø12.7(flare) ø6.35(flare) ø20.5x5places M10x4places 280 Open 80 250 Notes: (1) It must not be surrounded by walls on the four sides. (2) The unit must be fixed with anchor bolts.an anchor bolt must not protrude more than 15mm. (3) Where the unit is subject to strong winds, lay it in such a direction that the blower outlet faces perpendicularly to the dominant wind direction. (4) Leave a 1m or larger space above the unit. (5) A wall in front of the blower outlet must not exceed the units height. (6) The unit name plate is attached on the lower right corner of the front panel. 1 2 3 22 High Performance Air Conditioning

Outdoor Unit Dimensions FDC71VN (unit:mm) 340 61 47.5 61 150 223 60 15 532 D 580 880 2-ø15 25.8 150 29.8 87.9 19 380 19 418 L2 Intake Examples of installation Dimensions L1 L2 L3 L4 L1 L3 1 Open 300 100 250 Intake outlet Service space 2 L4 Minimum installation space Open 250 150 250 3 500 Open 100 250 E 150 580 150 40 55 340 47 40 D 310 222 40 Terminal block 20 380 20 750 165.5 25.5 B Mark A B C D E F Item Refrigerant gas side pipe connection tap Refrigerant liquid side pipe connection tap Pipe/cable draw-out port Drain discharge port Anchor bolt hole Cable draw-out port ø15.88(flare) ø9.52(flare) ø20.3x3places M10x4places ø30.3x3places 24.1 48.5 103.3 30 A 30 Notes: (1) It must not be surrounded by walls on the four sides. (2) The unit must be fixed with anchor bolts.an anchor bolt must not protrude more than 15mm. (3) Where the unit is subject to strong winds, lay it in such a direction that the blower outlet faces perpendicularly to the dominant wind direction. (4) Leave a 1m or larger space above the unit. (5) A wall in front of the blower outlet must not exceed the units height. (6) The unit name plate is attached on the lower right corner of the front panel. FDC100VN, 125VN, 140VN B 100 40 36 51 A Mark A B C D E F Item Refrigerant gas side pipe connection tap Refrigerant liquid side pipe connection tap Pipe/cable draw-out port Drain discharge port Anchor bolt hole Cable draw-out port ø15.88(flare) ø9.52(flare) ø20.3x3places M10x4places ø30.3x3places Notes: (1) It must not be surrounded by walls on the four sides. (2) The unit must be fixed with anchor bolts.an anchor bolt must not protrude more than 15mm. (3) Where the unit is subject to strong winds, lay it in such a direction that the blower outlet faces perpendicularly to the dominant wind direction. (4) Leave a 1m or larger space above the unit. (5) A wall in front of the blower outlet must not exceed the units height. (6) The unit name plate is attached on the lower right corner of the front panel. Terminal block B A 845 F A F 50 50 50 10 110 195 242 279 195 110 150 70 970 C 55 50 15 52 27 50 C 40 C 15 50 VIEW A E 190 580 200 60 60 60 15 410 20 370 40 55 38 103 15 C L2 Intake L1 L3 Intake outlet Service space L4 Examples of installation 1 Dimensions L1 Open L2 300 L3 150 L4 5 2 Open 5 300 5 3 500 Open 150 5 20 40 262 388 D Minimum installation space Packaged Air Conditioners 23

Before starting use Heating performance The heating performance values (kw) described in catalog are the values obtained by operating at an outdoor temperature of 7C and indoor temperature of 20C as set forth in the ISO Standards. As the heating performance decreases as the outdoor temperature drops, if the outdoor temperature is too low and the heating performance is insufficient, use other heating appliances as well. Indication of sound values The sound values are the values (A scale) measured in a chamber such as an anechoic chamber following the ISO Standards. In the actual installation state, the value is normally larger than the values given in the catalog due to the effect of surrounding noise and echo. Take this into consideration when installing. Use in oil atmosphere Avoid installing this unit in as atmosphere where oil scatters or builds up, such as in a kitchen or machine factory. If the oil adheres to the heat exchanger, the heat exchanging performance will drop, mist may be generated, and the synthetic resin parts may deform and break. Use in acidic or alkaline atmosphere If this unit is used in acidic atmosphere such as hot spring areas having high level of sulfuric gases or in alkaline atmosphere including ammonia or calcium chloride, places where the exhaust of the heat exchanger is sucked in, or at coastal areas where the unit is subject to salt breezes, the outer plate or heat exchanger, etc., will corrode. Please ask a dealer or specialist when you use an air conditioner in places differing from a general atmosphere. Use in places with high ceilings If the ceiling is high, install a circulator to improve the heat and air flow distribution when heating. Refrigerant leakage The refrigerant (R410A) used for Air conditioner is non-toxic and nonflammable in its original state. However, in consideration of a state where the refrigerant leaks into the room, measures against refrigerant leaks must be taken in small rooms where the tolerable level could be exceeded. Take measures by installing ventilation devices, etc. Use in snowy areas Take the following measures when installing the outdoor unit in snowy areas. Snow prevention Install a snow-prevention hood so that the snow does not obstruct the air intake port or enter and freeze in the outdoor unit. Snow piling In areas with heavy snow fall, the piled snow could block the air intake port. In this case, a frame that is 50cm or higher than the estimated snow fall must be installed underneath the outdoor unit. Automatic defrosting device If the temperature is low, and the humidity is high, frost will stick to the heat exchanger of the outdoor unit. If use is continued, the heating performance will drop. The Automatic defrosting device will function to remove this frost. After heating for approx, three to ten minutes, it will stop, and the frost will be removed. After defrosting, hot air will be blown again. Servicing the air-conditioner After the air-conditioner is used for several seasons, dirt will build up in the air-conditioner causing the performance to drop. In addition to regular servicing, we recommend the maintenance contract (charged for) by a specialist. Safety Precautions Air-conditioner usage target The air-conditioner described in this catalog is a dedicated cooling/heating device for human use. Do not use it for special applications such as the storage of foodstuffs, animals or plants, computer server rooms, precision devices or valuable art, etc. This could cause the quality of the items to drop, etc. Do not use this for cooling vehicles or ships. Water leakage or current leaks could occur. Before use Always read the User,s Manual thoroughly before starting use. Installation Always commission the installation to a dealer or specialist. Improper installation will lead to water leakage, electric shocks and fires. Make sure that the outdoor unit is stable in installation. Fix the unit to stable base. Usage place Do not install in places where combustible gas could leak or where there are sparks. Installation in a place where combustible gas could be generated, flow or accumulate, or places containing carbon fibers could lead to fires. Only persons that are qualified and licensed are permitted to install and service products that contain refrigerants in Australia, go to www.arctick.org. Suitable access for service must be provided in compliance with industry standards and local regulations. National Contact Information: ABN 92 133 980 275 Phone: 1300 138 007 Fax: 1800 644 329 www.mhiaa.com.au New South Wales & Head Office Victoria Queensland Western Australia 9C Commercial Road 10 Derby Street 2/27 Kingtell Place 1 Frederick Street Kingsgrove NSW 2208 Collingwood VIC 3066 Geebung QLD 4034 Belmont WA 6104 PO Box 318 Kingsgrove NSW 1480 PO Box 124, Virginia QLD 4014 PO Box 667 Belmont WA 6104 MRE SPARE PARTS www.mrespareparts.com.au Tel: +61 (0) 2 9600 7444 Fax: +61 (0) 2 9600 8044 ISO9001 Our Air Conditioning & Refrigeration Systems Headquarters is an ISO9001 approved factory for residential air conditioners and commercial-use air conditioners (including heat pumps). BIWAJIMA PLANT Mitsubishi Heavy Industries, Ltd. Air-conditioning & Refrigeration Systems Headquarters Certified ISO 9001 Certificate number : JQA-0709 MITSUBISHI HEAVY INDUSTRIES- MAHAJAK AIR CONDITIONERS CO., LTD. Certified ISO 9001 Certificate Number : 04100 1998 0813 ISO14001 Our Air Conditioning & Refrigeration Systems Headquarters has been assessed and found to comply with the requirements of ISO14001. BIWAJIMA PLANT Mitsubishi Heavy Industries, Ltd. Air-conditioning & Refrigeration Systems Headquarters Certified ISO 14001 Certificate number : JQA-EM0256 ISO 14001 Certificate 04104 1998 0813 E5 MITSUBISHI HEAVY INDUSTRIES- MAHAJAK AIR CONDITIONERS CO.,LTD. Certificate Number : 04104 1998 0813 E5 Because of our policy of continuous improvement, we reserve the right to make changes in all specifications without notice. E&OE. MHIAA185_PAC FD series Aug 2010