ADDENDUM TO LIT91127U EVO CONFIGURED IN ODD WATER SYSTEM DESIGN

Similar documents
SuperStor Glass Lined Storage Tank

SuperStor Ultra Stainless Steel Storage Tank

INSTALLATION AND OPERATING INSTRUCTIONS

Universal Fire Tube Boiler Wall Mount Models

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Installation & Operation Manual Models:

Slant Fin Corp. Installation and Operation Instructions

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

USER S INFORMATION MANUAL

Aqua Balance. User s Information Manual. WMB-155C Wall Mount Gas-Fired Combination Boiler Heating and Domestic Hot Water

Installation & Operation Manual Models: SIT030, SIT040, SIT050, SIT065, SIT080, & SIT119

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS IBC TECHNOLOGIES INDIRECT-FIRED WATER HEATERS

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-SOLO-9/04

Installation & Operation Manual Models: TSU

Gas Fired Residential Combi Boiler Floor and Wall Mount Models

Table of Contents. Installation, Operation, and Maintenance Manual ELBPxx

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 11/10/08

Armstrong Flo-H2O Water to Water Instantaneous Heater Installation and Maintenance & Operation

Installing, Operating & Maintaining EVO DUO/EVO MICRO HIGH EFFICIENCY WATER HEATERS AND HEATING BOILERS

Installation & Operation Manual Models: SIT030 - SIT119

CAH SERIES INSTALLATION & MAINTENANCE MODELS CAH CAH

prestige Control Application Supplement - Type 5 MCBA WARNING

Installing, Operating & Maintaining EVO HIGH EFFICIENCY WATER HEATERS AND HEATING BOILERS

Indirect Fired Water Heaters

NOTICE: HTP reserves the right to make product changes or updates without notice and will not be held liable for typographical errors in literature.

Indirect Water Heater * I N S T A L L A T I O N A N D M A I N T E N A N C E * M A N U A L

TURBOMAX USE & CARE MANUAL WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR

INSTALLATION AND OPERATING INSTRUCTIONS IBC TECHNOLOGIES INDIRECT-FIRED WATER HEATERS

SuperStor Ultra Indirect Fired Water Heaters

PRO SERIES IMPORTANT SAFETY INFORMATION

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION WATER TREATMENT

NOTICE: HTP reserves the right to make product changes or updates without notice and will not be held liable for typographical errors in literature.

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

VWH Models 500 / 850 LP / HL / LPHL THIS MANUAL IS FOR USE WITH MOD CON BOILERS MANUFACTURED AFTER DECEMBER 1, 2012

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

Taco 00 Series Cartridge Circulators

VSL II QUICK START GUIDE

Installation & Operation Manual Models: SSS031, SSS041, SSS051, SSS081, & SSS119

GWC. User s Information Manual. Gas-Fired Water Boilers. Model

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

American Dish Service

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

Energy-Efficient, Environmentally-Friendly Heating Solutions. Baxi Luna HT Residential Troubleshooting Guide

Niles Steel Tank Hot Water Generator Installation and Operation Manual

95% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS REMOTE CONNECT CAPABLE CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

TABLE OF CONTENTS BRADFORD WHITE BOILERS

HPS Controls Ltd. Series 100 LTV / CTV Zone Control Stations. Heating and Radiant Floor Zone Control Stations. Installation Instructions

User s Information Manual

INSTALLATION & TECHNICAL MANUAL

prestige Control Application Supplement - TriMax

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev.

Date: Project #: Engineer: Prepared By: Bid Date:

Crown Boiler Company

prestige Control Application Supplement - TriMax

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

INSTALLATION INSTRUCTIONS

NOTICE: HTP reserves the right to make product changes or updates without notice and will not be held liable for typographical errors in literature.

/99 USA. Installation Manual SU Save These Instructions!

Dual Mixing Application

INSTALLATION INSTRUCTIONS WINTER/SUMMER KIT

INSTALLATION INSTRUCTIONS

HPS Controls Ltd. Series 600 LFI / CFI Series 700 HFS Zone Control Stations. Heating and Radiant Floor Zone Control Stations

prestige Control Application Supplement - Type 5 MCBA WARNING

OPERATING AND MAINTENANCE MANUAL

NOTES FOR AIR HANDLER APPLICATION:

Addendum H to Brute LX 1295A Document 1372

NOTICE: HTP reserves the right to make product changes or updates without notice and will not be held liable for typographical errors in literature.

EVO DUO/EVO MICRO HIGH EFFICIENCY WATER HEATERS AND HEATING BOILERS

Boiler Manual. Gas-fired water boilers. Featuring. Flexibility

Q - Series Boiler. Troubleshooting Manual

AQUAS POOL PACKAGE INSTALLATION INSTRUCTIONS FOR MODELS: AP AQUAS Pool Package

M2 Series Startup Form

H 2 INDIRECT-FIRED WATER HEATERS FOR SINGLE WATER HEATER INSTALLATIONS INSTALLATION, OPERATION & MAINTENANCE MANUAL

IBC Technologies Venables Street, Vancouver, BC, V5L 2G8 - Ph Fax E -

Insta-Therm Series Service, Installation and Operation Manual

User s Information Manual

Everlast Electric. Water Heaters. Use and Care Manual. Installation. Start-Up. Maintenance. Parts. Warranty. Residential EVR Models

ML180UH SERIES GAS FURNACE WARNING WARNING

WB90. Boilers. As an ENERGY STAR Partner, PB Heat, LLC has determined that this product meets the ENERGY STAR guidelines for energy efficiency.

Bulletin (Jan 2011) And User s Guide

Munchkin Gas-Fired Boiler

DIVISION FINNED WATER-TUBE BOILERS

AMERICAN EQUIPMENT SYSTEMS A Division Of Trevor-Martin Corporation th Terrace North Clearwater, Florida 33762

Light Duty Commercial Electric Water Heaters

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

Indirect-Fired Water Heaters

Boiler & Water Heater

Application Guide. Vitodens 100-W B1HA/B1KA Residential Boiler

Pipe: ASTM B88, hard drawn copper, Type K. Fittings: ASTM B16.22 Wrought copper and copper alloy.

Instruction manual. WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules

6 Zone 120/60/1vac 3A 24 VAC class 2 2 x 40 VA 2 x 5 amp fuses 1/6 hp, 120 VAC

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

BOILER APPLICATION GUIDE for:

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-315(C)

WARNING FIRE OR EXPLOSION HAZARD.

NOTICE: HTP reserves the right to make product changes or updates without notice and will not be held liable for typographical errors in literature.

GOLD Plus 30/40/60/80

USER'S INFORMATION MANUAL

Transcription:

INNOVATIVE CONDENSIN TECHNOOY By Hamilton Engineering, Inc. ADDENDUM TO IT91127U EVO 79-599 CONFIURED IN ODD WATER SYSTEM DESIN WARNIN These appliances MUST be installed by a properly licensed individual in the City and State which the unit is being installed. All start up adjustments and subsequent service work must be done by a similarly licensed contractor or a factory trained service individual. Failure to comply could result in loss of warranty and or severe personal injury, death and or substantial property damage. These instructions are required to be kept with the appliance on the left side, in the pocket provided.

All safety precautions referenced to in IT91127U (EVO 79-599 Universal Installation and Operating Manual) should be STRICTY adhered to! There are two basic system configurations. lease determine which style you have and refer to the specific instructions where indicated. lease contact Hamilton Engineering, Inc. at 800.968.5530 if you have any questions regarding system configurations. (FIURE 1) SYSTEM DESIN A This system design employs a storage tank with integral heating coils and will require only one circulating pump. (FIURE 2) SYSTEM DESIN B This system design employs an external heat exchanger and requires one circulating pump for the closed loop (boiler) side and a bronze pump for the fresh water (storage tank) side. age 2 of 9

SYSTEM REQUIREMENTS System requirements beyond what is listed here can be found in IT91127U (EVO 79-599 Universal Installation and Operating Manual): Electrical: System B: 208 240 volt amperage per system rating plate, 208-230 volt per stainless steel pump rating plate. Wiring diagram is located on page 9 of this Manual. Service Clearances: System B: rovide adequate access to heat exchanger for periodic acid cleaning and or removal for additional service as required System operation: System A The 4006A storage tank temperature control shall be set at the desired storage tank water temperature (per original design), on approximately a 5 F drop from desired setpoint, the SST switch in the 4006A will make, closing the heat enable circuit on the heating boiler. After receiving this signal, the boiler control will start the cast iron pump and initiate a firing sequence and provide the required closed loop water temperature (generally 150 F 180 F; see system design specifications) as set by user on the red wheel located next to the temperature display on the front of the boiler, to provide the designed recovery rate through the tank heat exchanger. If there is more than one boiler providing the required BTU capacity, the setting and control wiring shall be done on the ead labeled boiler only. System B - The 4006 storage tank temperature control shall be set at the desired storage tank water temperature (per original design), on approximately a 5 F drop from setpoint, the control will close both internal SST switches, simultaneously starting the bronze circulating pump and closing the heat enable circuit on the heating boiler. After receiving this signal, the boiler control will start the cast iron pump and initiate a firing sequence and provide the required closed loop water temperature (generally 150 F 180 F; see system design specifications) as set by user on the red wheel located next to the temperature display on the front of the boiler, to provide the designed recovery rate through the external heat exchanger. If there is more than one boiler providing the required BTU capacity, the setting and control wiring shall be done on the ead labeled boiler only. Filling Instructions: The Odd Water system comes equipped with a pressure reducing fill station for the boiler (closed loop) side of the system, that is pre-piped to EVO system city water connection. Included in this package are a low pressure switch, pressure gauge, air vent, pressure reducing fill valve, expansion tank, check valve, backflow preventer, isolation valves, optional water meter, and a union for easy disassembly. Once the city water connection is made, open the air vent in the fill package and on the top of boiler(s) (models 299-599 ONY). Once the air vent(s) is open, turn on the city water supply and open the (3) isolation valves, each located on the expansion tank, near the city water connection, and after the pressure reducing valve. When air is no longer bleeding out of the air vent(s), turn the boiler(s) on, which will cycle the pump(s), purging any air remaining in the system. NOTE: There MUST be a city water supply connected that is regulated down to 12 SI (via the RV supplied) for the system to work properly! age 3 of 9

2 3 2 1 1 3 4 4 5 6 5 (FIURE 3) SYSTEM DESIN A WITH ARTS H I J K F (Optional) A City Water Connection E (Optional) Q N B D M O (TABE 1) SYSTEM DESIN A - ARTS C A B C D E F H I J K M N O Q etter on diagram Description EVO unit Cast Boiler Side ump Condensate Neutralizer Hydronic Expansion Tank - 12 SI air charge Storage Tank 4006A Temperature Control ow ressure Switch ressure auge Air Vent Fill Valve Check Valve Water Meter (optional) Backflow reventer Hot Water Connection Drain Valves Cold Water Connection Domestic Expansion Tank (optional) age 4 of 9

SYSTEM B - ARTS (FIURE 4) SYSTEM DESIN B WITH ARTS H I J O City Water Connection K M N B A T C D R E F S (Optional) Q (TABE 2) SYSTEM DESIN B - ARTS etter on diagram A B C D E F H I J K M N O Q R S T Description EVO unit Electrical Disconnect Cast Boiler Side ump Condensate Neutralizer Hydronic Expansion Tank - 12 SI air charge Stainless Steel Domestic Hot Water ump Brazed late Heat Exchanger Air Vent ressure auge ow ressure Switch Fill Valve Check Valve Backflow reventer Water Meter (optional) Storage Tank External Heat Exchanger Cleaning and Draining orts Brass Wye Strainer Normally Closed Cleaning Bypass Valve Domestic Expansion Tank (optional) 4006 Temperature Control age 5 of 9

ADDITIONA INFORMATION Both system designs are completely factory assembled and tested prior to shipping, following assembly at the installation site, however, filling the system requires that proper practices be followed: The boiler is designed to operate in a closed-loop system. As such, the system should be tight and not require make-up water. A high percentage of untreated make-up water may cause premature failure due to buildup of scale; such failure is not covered by warranty. Scale can also reduce efficiency. For example, a scale thickness of 1/16 will result in a 12.5% loss of efficiency. NOTE: Minimum system fill pressure is 12 SI! Water ph The ph of the hydronic system fluid must be between 6.5 and 7.5, for untreated water only. A periodic check of the system ph should be conducted to ensure these ph levels are maintained. IMORTANT! lycol and other additives must be approved by the chemical manufacturer for use in 316 stainless steel boilers as well as the circulating pumps used with the boilers and heating system, and you must maintain the required ph levels as recommended by the glycol or treatment chemical manufacturer to prevent damaging the boiler and or pumps. If the water quality exceeds our known safe thresholds, we wave the red flag of caution: Water hardness can be no more than 12 grains (205 ppm or mg/l) TDS (Total Dissolved Solids) can be no more than 450 ppm (mg/l) H - below 6.5 or above 7.5 For total combined hardness over 15 grains (250 ppm or mg/l) or longer pipe lengths, contact Hamilton Engineering for correct pump sizing. Combined, the hardness and TDS can be no more than 450 ppm. Our internal term for this is the TCH (Total Combined Hardness). The amount of oils, fats, grease, and other organic matter should be limited to 10 ppm. Consult your water conditioning or chemical treatment supplier for analysis and recommendations. Flushing the System Before filling the boiler, flush the system to remove any debris from construction or maintenance. Clean and flush old piping thoroughly before installing the boiler. IMORTANT! Under no circumstances should the hydronic system be flushed while the boiler is attached to the system since the debris or corrosion products could accumulate in the boiler and plug the boiler heat exchanger. IMORTANT! If the piping system attached to this unit will be chemically cleaned, the boiler must be disconnected from the system and a bypass installed so that the chemical cleaning solution does not circulate through the boiler. Following chemical cleaning, the system should be thoroughly rinsed to remove cleaning agents prior to reconnecting the boiler to the system. age 6 of 9

ODD WATER WIRIN DIARAMS EAD OR SINE BOIER ONY - SYSTEMS A & B A B C D E F H I J K M ST-1 ST-2 ST-3 ST-4 ST-5 ST-6 ST-7 1 2 3 4 5 6 Outdoor Sensor External Sensor Indirect Sensor or Aquastat 7 + - 0-10 VDC 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Additional ock Out Heat Source Signal Dry Contact Dry Contact Remote Thermostat + - Cascade Connection not in use 1 2 1 open com. close Divertor Valve Indirect 2 1 ump 2-indirect 1 2 ump 1 2 ump 3 1 26 27 28 1 2 ower Supply 208-240 Vac For use with Central heating for outdoor reset Used for storage tank or common line sensing Used for indirect tank Building management system For use with additional heat needed w/cascade For use with alarm bell / light Connection from 4006 thermostat Must connect + to + and - to - between appliances in cascade Used in a boiler system with both CH & DHW ump 2: Used in a boiler system with both CH & DHW ump 1: Boiler ump ump 3: Heater ump To round Service Switch Fused switch or from a maximum 15 amp dedicated circuit breaker age 7 of 9

ODD WATER WIRIN DIARAMS EAD OR SINE BOIER ONY - SYSTEM A 240v ower Supply Tank Stat TST 63000 ressure Switch HYD 47001 EVO ower/control Terminal Strip ST-1 ST-2 ST-3 ST-4 ST-5 ST-6 ST-7 1 3 4 5 6 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 + - 1 2 1 1 2 1 2 Outdoor External Indirect + - Additional ock Out Remote Cascade open com. 0-10 close Heat Signal ump 1 Sensor Sensor Sensor Thermostat Connection Divertor Valve Indirect ower Supply VDC Source Dry 2 1 208-240 Vac or 2 1 Dry Contact Aquastat ump 2-indirect Contact ump 3 208-240 v 1 ph ower Supply SETOINT TEMERATURE RESET SERVICE - + BURNER ON 240V Boiler ump Service Disconnect HAMITON ENINEERIN Dwg. No.: 34000 Autry St. ivonia, MI 48150 H: (800) 968-5530 Fax: (734) 419-0209 Checked. By: Dwg. By: Customer: Description: Date: Scale: NTS 2 7 8 9 not in use AE 10/29/10 Control wiring diagram for Odd Water system Type A (with Indirect tank) age 8 of 9

EAD OR SINE BOIER ONY - SYSTEM B 240v ower Supply Tank Aquastat TST 54006 ressure Switch HYD 47001 EVO ower/control Terminal Strip ST-1 ST-2 ST-3 ST-4 ST-5 ST-6 ST-7 1 3 4 5 6 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 + - 1 2 1 1 2 1 2 Outdoor External Indirect + - Additional ock Out Remote Cascade open com. 0-10 close Heat Signal ump 1 Sensor Sensor Sensor Thermostat Connection Divertor Valve Indirect ower Supply VDC Source Dry 2 1 208-240 Vac or 2 1 Dry Contact Aquastat ump 2-indirect Contact ump 3 208-240 v 1 ph ower Supply SETOINT TEMERATURE RESET SERVICE - + BURNER ON 240V Boiler Side ump 240V Tank Side ump Service Disconnect HAMITON ENINEERIN Dwg. No.: 34000 Autry St. ivonia, MI 48150 H: (800) 968-5530 Fax: (734) 419-0209 Checked. By: Dwg. By: BD 06/17/09 NTS Customer: Description: Date: Scale: 2 7 8 9 not in use Boiler #2 Boiler #1 Control wiring diagram for Odd Water system Type B age 9 of 9