Dräger Pac 8500 Single-Gas Detector

Similar documents
Dräger Pac 6000 Single-Gas Detector

Dräger Pac 8500 Single-Gas Detection Device

Dräger Pac 6000 Single-Gas Detection Device

Dräger Pac 8000 Single-Gas Detection Device

Dräger Pac 3500 Single-Gas Detection Device

Dräger Pac 5500 Single-Gas Detection Device

Dräger Pac 3500 Single-Gas Detection Device

Dräger X-am 5000 Multi-Gas Detection

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

Dräger Pac 7000 Single-Gas Detection Device

Dräger X-am 5000 Multi-Gas Detector

Dräger X-am 2500 Multi-Gas Detector

Dräger X-dock 5300/6300/6600 Calibration and Bump Testing

Dräger X-am 2500 Multi-Gas Detection

Dräger REGARD -1 Control System

Dräger X-am 5000 Multi-Gas Detection

Catalytic Bead DrägerSensors for Fixed Gas Detectors

Dräger Configuration and Evaluation Software

Dräger X-zone 5500 Area Monitoring

Dräger Bump Test Station Calibration and Bump Testing

Dräger Flame 2100 Flame Detection

Dräger Catalytic Ex-Sensors DrägerSensors

Dräger Polytron 5720 IR Toxic Gas Detection

D D D Dräger Gas Detection ST Dräger: Technology for Life

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Flame 2500 Flame Detection

Dräger X-zone 5500 Area Monitoring

Dräger X-am 7000 Multi-Gas Detection

Dräger PIR 7200 Toxic Gas Detection Transmitter

Dräger Polytron Pulsar 2 Open Path Gas Detector

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger AFS 3000 Aircraft Fire Simulator

Dräger X-am 7000 Multi-Gas Detection

Training Gas Detection Level 2 User and Calibration. Basic Information

Dräger DM-6 BG 4 Mask Dryer Workshop Systems

Dräger UCF 7000 Thermal Imaging Camera

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger X-zone 5500 Multi-Gas Detection Device

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Exterior Live Fire Training System (ELFTS) the QUAD

Dräger Catalytic Ex-Sensors DrägerSensors

Training Gas Detection Level 3 Maintenance and Repair

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

Dräger REGARD -1 Control System

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

Dräger Exterior Live Fire Training System (ELFTS-C), the CAR

Dräger PointGard 2100 Detection of toxic gases and vapours

Dräger Flame 2350 (UV&IR) Flame Detection

D Realize the rewards of quality single gas detection. DRÄGER PAC 3500 DRÄGER PAC 5500 DRÄGER PAC 7000

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Flame 2370 (UV&IR) Flame Detection

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Catalytic Bead DrägerSensor Sensors for Fixed Gas Detectors

Dräger Bodyguard 1000 Warning Device

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger Flame 2500 (IR3) Flame Detection

Dräger X-pid 9000 / 9500 Multi-Gas Detection

Dräger Polytron 7000 Detection of toxic gases and oxygen

Dräger Flame 2100 (UV) Flame Detection

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Dräger PIR 7200 Detection of toxic gases and oxygen

GasAlertMicroClip X3 Specifications

Dräger Flame 2700 (Multi-IR) Flame Detection

On-site & Shutdown Safety Service CSE Monitoring

For the Safety of Your

ALTAIR 5X Multigas Detector Product Specification

Dräger REGARD -1 Control System

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

T.ex Single Gas Detector VISA

safe and your operations compliant

Dräger X-am approved as type MQG 01** Multi-Gas Monitor. Technical Handbook. CO2 Vol% CH4 %UEG. CO ppm. ppm NH _01.

Monitores Personales. Personal Monitor

Dräger REGARD 3900 Series Control System

Training Authorised Gas Tester Level 1. Basic Information

Electrochemical (EC) DrägerSensors for Fixed Gas Detectors

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 7000 Fixed gas detector

IT S WHAT S INSIDE THAT

Oxylog VE300 Emergency & Transport Ventilation

ST Safety to go. DRÄGER PORTABLE GAS DETECTION INSTRUMENTS

Dräger PIR 7000 Flammable Gas Detection

Dräger X-am approved as type MQG 0010 Multi-Gas Monitor Technical Manual _01.eps

1.1 Definitions of alert icons. For your safety

Oxylog VE300 Emergency & Transport Ventilation

ALTAIR 5X Multigas Detector

Dräger Polytron 8000 Stationary gas detector (EC)

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

Dräger Polytron 8000 Stationary gas detector (EC)

Dräger QuadGard Control System

G-TECTA TM. Portable Gas Detection Instruments

IT S WHAT S INSIDE THAT COUNTS

Dräger Polytron 8310 Stationary gas detector (DSIR)

Transcription:

Dräger Pac 8500 Single-Gas Detector The Dräger Pac 8500 single-gas detection device is a reliable and precise instrument even under the toughest of conditions. The detector can be equipped with a hydrogen-compensated CO sensor or a Dräger dual sensor. The dual sensors provide the option of measuring two gases at once: either H 2 S with CO or O 2 with CO. Easy fastening with tightly closing crocodile clip Illuminating D-Light shows detector is tested and ready for use Easily replaceable ilter membrane protects the sensor Robust housing with handy design for tough conditions Large display shows all important information D-4996-2017 Clear color coding prevents mistakes 360 alarm signal can be easily seen from all sides

02 Dräger Pac 8500 Benefits Strong performance for maximum safety You can count on the Dräger Pac 8500 to give you reliable, precise readings at any time even under extreme conditions. Our powerful sensors with a low t-90 response time ensure quick reactions. In addition to the standard alarms, you can define extra alarm thresholds for TLV * and STEL*. The Pac 8500 also provides a data and event logger for logging concentrations and events along with the date and time. The data can be loaded on a PC via an interface and processed further there. * TLV = Threshold Limit Values, STEL = Short Term Exposure Limit Two gas detection in a single-gas device The Dräger Pac 8500 series offers the following sensor combinations: hydrogen sulfide with carbon monoxide or oxygen with carbon monoxide. Dual sensors enable detection of even low concentrations all in one and the same handy device. Measuring two gases at the same time reduces downtime as well. You can take vol.% measurements of oxygen and ppm measurements of carbon monoxide simultaneously using just one gas detector. Measurement of carbon monoxide with significantly reduced cross sensitivity In industries where carbon monoxide needs to be measured with hydrogen as a background gas, the measured value for carbon monoxide may be falsified by cross sensitivity. Thanks to the special hydrogen-compensated CO sensor from Dräger, this cross sensitivity to hydrogen is significantly reduced in the display of carbon monoxide. This new feature can eliminate the need to carry two different detectors. Robust design even for the toughest conditions The Pac 8500 is easily handled in even extreme conditions. The sensors can tolerate air pressures between 700 and 1,300 mbar. A membrane filter protects the sensor from foreign matter such as dust and liquids. The shock-proof, chemical-resistant housing meets the requirements specified in the IP68 standard rating. Easy handling thanks to clear user guidance The D-Light indicates whether functionality of the device has been tested and if it is ready to use. The housing is also designed with your safety in mind: each sensor variant of the Dräger Pac 8500 features clearly visible color coding, thereby minimizing the chance of mistakes. User-friendly display with all important information The large display is word-free and clearly indicates the respective gas concentration. Other important information, such as the unit of concentration and battery capacity, is also displayed. The bright backlighting ensures that all values are clearly legible in the dark.

Dräger Pac 8500 03 Benefits 360 alarm with various functions If the Dräger Pac 8500 measures hazardous gas concentrations, it sets off an audible, visual and perceptible vibrating alarm. Two bright, flashing LEDs on the top and bottom of the device ensure that the alarm is easily visible from all sides. The acoustic signal reaches a volume of 90 db. The display can show the peak concentration measured at any given moment. Earlier alarms registered can also be retrieved at a later time, even if they have been acknowledged. The Pac 8500 with oxygen sensor has two additional alarm thresholds in addition to the standard alarm threshold settings. This provides an additional level of safety as a pre-alarm, in addition to the main alarm, can be set for both oxygen enriched and oxygen deficient atmospheres. Economical operating costs All of the versions of the Dräger Pac 8500 are equipped with extremely durable DrägerSensors and a powerful battery. The Pac 8500 is protected against water, dust and other foreign bodies by a special membrane filter. When the filter becomes heavily soiled in use, you can quickly and easily replace it yourself. The detector is then ready to use again right away. Thanks to the powerful battery, the Pac does not require charging on a daily basis and is easy to handle. Fast function test saves time and money Function tests and calibrations can be carried out especially efficiently in the Dräger X-dock calibration station. The automatic bump tests in the X-dock are a cost-efficient and convenient solution thanks to the short test duration and the extremely low consumption of test gas. The Pac 8500 is simply placed in the bump test station and automatically selects the correct setting.

04 Dräger Pac 8500 Dräger Pac product range at a glance System Components DrägerSensor XXS Dräger has developed miniature electrochemical sensors specially for the Dräger Pac and X-am 1/2/5 generation gas detectors. The sensors detect many different gases and vapors. They are also very reliable and stable over the long-term, thereby reducing your operating costs. D-12191-2010

Dräger Pac 8500 05 System Components Dräger X-dock 5300/6300/6600 Automatic bump tests, calibration, reduced test gas consumption, short testing times, and comprehensive documentation come standard in this new device from Dräger, the experts in gas detection. ST-740-2006 D-47907-2012 Dräger Bump Test Station The Bump Test Station is easy to use, stand-alone and flexible. In this regard, function tests of gas detection and warning devices can be carried out easily and independently of the location. Accessories Dräger Configuration and Evaluation Software Tailor-made Dräger software makes saving measurement results, professionally configuring gas detection instruments, and viewing performance data possible. D-30746-2015

06 Dräger Pac 8500 Accessories Calibration gas and accessories For the safe operation of devices, applicable regulations and statutory provisions are to be met and complied with. Therefore, regular calibrations and function tests are necessary. Different systems are available so that products meet a wide range of calibration requirements. ST-5018-2005 ST-5080-2005 Calibration Adapter The communication module (including USB cable) is used to connect the equipment to the configuration and evaluation software. The module is also used for the manual bump test or manual calibration. The test gas is introduced to the Pac device through the gas inlet or outlet. Services Dräger Service When your operation s safety equipment is backed by over 125 years of experience and supported by the same team that engineered it, you can rely on service and rental solutions that are tailored to meet your unique needs. With Dräger s safety solutions, you get complete peace of mind, budget security, and full-service support that you can count on every step of the way. That s the Dräger Service Advantage. D-19072-2016

Dräger Pac 8500 07 Related Products Dräger Pac 6000 The Dräger Pac 6000 disposable personal gas detector measures CO, H 2 S, SO 2 or O 2 reliably and precisely, even in the toughest conditions. The robust design, quick sensor response times, and a powerful battery ensure maximum safety for up to two years with virtually no maintenance required. D-4987-2017 D-4977-2017 Dräger Pac 6500 The robust Dräger Pac 6500 is your reliable companion under tough conditions. The personal single-gas detection device measures CO, H 2 S, SO 2 or O 2 quickly and precisely. Quick sensor response times and a replaceable battery also ensure safety. Dräger Pac 8000 With the robust Dräger Pac 8000, you'll be well equipped for tough conditions: this non-disposable, personal single-gas detection device is a reliable and precise instrument, which detects hazardous concentrations of twenty nine different gases, including special gases like NO 2, O 3 or COCl 2. D-4989-2017

08 Dräger Pac 8500 Technical Data Dräger Pac 8500 Dimensions (without clip) (W x H x D) Weight Battery service life Protection class Air pressure Air humidity 2.5 x 3.3 x 0.8 in, 64 x 84 x 20 mm Approx. 3.7 ounces, 106 g (4.0 ounces, 113 g with clip) Min. 2 years (O 2 and dual sensors min. 12 months) IP68 700 to 1,300 hpa 10 to 90% relative humidity, non-condensing Temperature -22 F to 131 F, -30 C to +55 C (briefly down to -40 F / -40 C for 1 hr, depending on sensor) Approvals ccsa us, IECEx, ATEX, CE Ordering Information Dräger Pac 8500 Description Measuring range Alarm thresholds A1/A2 Dräger Pac 8500 H 2 S/CO 0 100 ppm H 2 S 0 2,000 ppm CO Dräger Pac 8500 O 2 /CO 0 25 Vol.-% O 2 0 2,000 ppm CO 10 / 15 ppm H 2 S 35 / 50 ppm CO 19.5 / 23.5 Vol.-% O 2 35 / 50 ppm CO Order number 83 28 263 83 28 265 Dräger Pac 8500 CO-H 2 CP 0 2,000 ppm 35 / 50 ppm 83 27 617 Dräger Pac 8500 CO-H 2 CP (Canada) 0 2,000 ppm 25 / 50 ppm 83 28 262 Dräger Pac 8500 As per customer request As per customer request 83 26 343 Calibration accessories Calibration adapter 83 18 588 Dräger X-dock 5300 Pac 83 21 881 Dräger Bump Test Station for Dräger Pac, without gas cylinder 83 17 410 Dräger Bump Test Station for Dräger Pac, including one test gas cylinder (selectable gas and concentration) Communication accessories Dräger CC-Vision Basic, available free of charge at www.draeger.com 83 18 586 Communication module, including USB cable 83 18 587 Spare parts Battery 83 26 856 Sensor grid (silver) 83 26 852 Crocodile clip set 83 19 186 TLV is a registered trademark of ACGIH.

Notes Dräger Pac 8500 09

10 Dräger Pac 8500 Notes Not all products, features, or services are for sale in all countries. Mentioned Trademarks are only registered in certain countries and not necessarily in the country in which this material is released. Go to www.draeger.com/trademarks to find the current status. 91 03 305 18.02-2 HQ PP Subject to modifications 2018 Drägerwerk AG & Co. KGaA CORPORATE HEADQUARTERS Drägerwerk AG & Co. KGaA Moislinger Allee 53 55 23558 Lübeck, Germany www.draeger.com Customer Service: USA +1 800-4DRAGER (+1 800-437-2437). CANADA +1 877-DRAGER1 (+1 877-372-4371). Technical Service: USA +1 800-4DRAGER (+1 800-437-2437). Locate your Regional Sales Representative at: www.draeger.com/contact