Trench Heating Katherm QK Tested acc. to: EN 16430 March 2015
EC technology: the ace up your sleeve New EC technology is a revolution in electronic drive technology. High output, yet whisper quiet, even with low water temperatures. 1 I 6
Wide ranging Choose from a huge standard range of sizes - 3 different widths each available at 12 different lengths. 2 I 6
Tailor-made Your customer gets the thing you appreciate about Kampmann: individual made-to-fit trenches for all façades. Regardless of whether you need mitred corners, curved trenches, column cutouts etc. 3 I 6
Design in mind So many standard grille finishes and always with a matching frame. The icing on the cake for a perfect look. 4 I 6
Flexible Katherm QK trench units can be equipped as standard with a 0-10V BMS interface for Fan speed control. Units can be supplied individually or in banks with a choice of Class 2 Transformers. All units have been designed specifically for the North American market and are therefore fully certified to UL/cUL 1995 (CSA C22.2). 5 I 6
Design with confidence Design around our standard trenches in the knowledge that we have short delivery times, fast and easy installation and our support throughout to meet your individual project needs. 6 I 6
Slip joints possible High-performance convector Grille finish Eurokonus valve connection Control terminal box Roll-up grille: aluminium, natural anodised Extra long EC fan Anti-twist device for heating connection Positive fixing to concrete slab Load-bearing height adjustment feet Katherm QK at a glance
Slip joints possible To allow continuous grille appearance 1 I 9
Cover plate As visual cover and protection against dirt ingress 2 I 9
Control terminal box With BMS-Interface Electrical connections: 1 x BMS and 1 x 24V Supply connection per unit up to 3200mm (126 ) long For an easy and safe electrical connection Saves installation time Included in standard 3 I 9
Anti-twist device for heating connection Prevents damage to the convector when screwing in the valves Optional valves (accessories) 4 I 9
High-performance convector A proven combination of copper/aluminium Optimised for airflow and heat transfer Coated graphite-grey 5 I 9
Extra long EC fan For uniform convector airflow Resulting in high heat outputs at low sound emissions 6 I 9
1 2 1 2 3 4 5 6 Aluminium, natural anodised Aluminium, brass anodised Aluminium, bronze finish Aluminium, black anodised Aluminium, painted DB 703 Stainless steel 3 4 Choice of grilles (examples shown are roll-up grilles) 5 6 More grille finishes at Kampmann.ca/grilles 7 I 9
We can even cope with challenging sites with ease with our range of possible shapes and sizes. The following options are possible: Mitred corners Any angle possible Curved Curves Design of all components in a curved shape Cut-outs in the grille itself Integration of building parts, such as columns, mullions, etc. Cover plates at mullion positions Polygonal shapes along building façade Cover plate for an electrical installation Luminaires Sockets Cut-outs with a cover plate Integration of building parts, such as columns, mullions, etc. 8 I 9
Control options Power supply 24 V Optional DIN rail Class 2 Transformers for 120 V/60 Hz supply Fan speed control 20 to 100% via 0-10 V BMS signal 9 I 9
Heat output Katherm QK (with unit lengths 1000mm (39.4") to 3200mm (126") 1) Water temperatures Unit height Katherm QK 182 Katherm QK 207 Katherm QK 232 Sound pressure Width 7.16" Width: 8.15" Width: 9.13" level Sound power level [ C] [ F] [mm] [in] [W] [BTU] [W] [BTU] [W] [BTU] [db(a)] [db(a)] 82/71 180/160 112 4.41 517 3237 1764 11044 890 5580 3036 19038 1087 6818 3708 23263 28 36 36 44 75/65 167/149 112 4.41 455 2851 1552 9727 788 4938 2688 16848 954 5982 3255 20410 28 36 36 44 60/50 140/122 112 4.41 314 1967 1071 6711 552 3457 1883 11795 651 4084 2221 13934 28 36 36 44 49/43 120/110 112 4.41 230 1444 785 4927 410 2568 1399 8762 474 2971 1617 10137 28 36 36 44 40/35 105/95 112 4.41 157 985 535 3361 284 1778 969 6066 320 2005 1092 6841 28 36 36 44 1) Room air temperature = 20 C (68 F); 100 % fan speed Heat outputs tested in accordance with EN 16430 Parts 1 & 2. 1 I 2
Dimensions Overall unit length L 4 mm 0.16" 112 mm 4.41" Window side max. 146 mm max. 5.75 Room side Front view Cross-sectional view Katherm A Unit height Unit length [mm] [mm] Overall unit length L Finned convector length Window side QK 182 182 QK 207 207 112 (+4) 1000-3200 QK 232 232 Katherm A Unit height Unit length ["] ["] QK 182 7.16 QK 207 8.15 4.41 (+0.16) 39.4-126.0 Plan view, e.g. QK 207 Room side QK 232 9.13 2 I 2
Kampmann offers you the following service benefits: On-site consultation Diverse sampling Benefits for you! Design support Site-surveys Training After sales service Find your contact person here: Kampmann.ca/contact 1 I 2
Best solutions. Best support. Kampmann GmbH Friedrich-Ebert-Str. 128 130 49811 Lingen (Ems) Germany Kampmann Heating, Cooling, Ventilation Ltd. 600-890 West Pender Street Vancouver BC, V6C 1J9 Canada Kampmann.ca T + 49 591 7108-660 T + 49 591 7108-173 E export@kampmann.de W Kampmann.de T + 1 604 362 0180 F +1 604 687 1327 E info@kampmann.ca W Kampmann.ca 2 I 2