Meeks Bay Fire Protection District

Similar documents
RESOLUTION NUMBER RESOLUTION SETTING SERVICE FEES FOR OF FIRE & LIFE SAFETY ACTIVITIES.

FIRE DEPARTMENT SYSTEM PERMIT APPLICATION

Construction and Development Guide

ENGINEERING/PLAN REVIEW - FEE SCHEDULE Exhibit A

TRI-LAKES MONUMENT FIRE PROTECTION DISTRICT

OCFA Planning and Development Section Fees Effective September 28, 2015

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

WELLINGTON FIRE PROTECTION DISTRICT RESOLUTION #

CCCFPD RESIDENTIAL BUILDING REQUIREMENTS

FIRE DEPARTMENT DESCRIPTION OF SERVICE UNIT FEE I. INSPECTION FEE

C I T Y O F B A N N I N G BANNING FIRE SERVICES 3900 W. WILSON STREET (951) PHONE (951) FAX

VACAVILLE FIRE PROTECTION DISTRICT 420 Vine Street Vacaville, California (707)

SACRAMENTO FIRE DEPARTMENT FIRE PREVENTION DIVISION FIRE DEPARTMENT DEVELOPMENT SERVICES UNIT CONTRATOR INFORMATION PACKET

TABLE OF CONTENTS ADOPTED FIRE CODES... 3 AFPD SERVICE AREA... 3 SITE AND DEVELOPMENT SUBMITTAL REQUIREMENTS... 4 PLAN REVIEW FEES...

Brighton Fire Rescue District

30 DAY TEMPORARY TENT APPLICATION ON EXISTING COMMERCIAL PROPERTY

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

CITY OF PETALUMA FIRE DEPARTMENT. FIRE PERMIT AND HAZARDOUS MATERIALS (CUPA) FEE SCHEDULE (September 2002)

Norfolk Fire Department Fire Prevention & Information

Building Permit Type & Sub-Type Definitions

PINETOP FIRE DEPARTMENT TIMBER MESA FIRE AND MEDICAL DISTRICT

7/1/2018-6/31/2019 PROTECTION AND PLANNING FEE SCHEDULE

To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified as an R-3.1.

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

To expedite the plan review and inspection processes, please refer to the information below.

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

September 30, Dear Fire Suppression System Contractor/Designer:

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

FIRE ALARM APPLICATION CITY OF MADISON HEIGHTS

This guide is intended to provide assistance in the application of the fire code in all areas served by Tualatin Valley Fire & Rescue.

TAMARAC FIRE RESCUE DEPARTMENT FIRE PREVENTION BUREAU 6000 North Hiatus Road Tamarac, Florida Telephone: (954) , Fax: (954)

Fire Sprinkler Submittal Requirements and Acceptance Testing

Plan Submittal Checklist

TETON COUNTY FIRE PROTECTION RESOLUTION FOR NEW SUBDIVISIONS 2008 Edition. Chapter I General Provisions

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

FONTANA FIRE PREVENTION DISTRICT USER FEE LIST 2015 DEVELOPMENT SERVICES FEES PLANNING APPLICATION FEES Administrative Site Plan 516 Conditional Use

COMMUNITY RISK REDUCTION BUREAU MANUAL TABLE OF CONTENTS EFFECTIVE: APRIL 1, 2016 AUTHORIZED: R. Pearce

New Construction Fire Inspection Process

May 1, Dear Fire Suppression System Contractor/Designer:

Fire Department Fee Schedule

CITY OF PASADENA FIRE DEPARTMENT

2. Building Code Permits and Related Fees 2018

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

Pismo Beach, CA Municipal Code. Chapter 8.08 FIRE PREVENTION REGULATIONS

CAMP VERDE FIRE DISTRICT

Tents and Temporary Membrane Structures Permit Procedure

Rocky Mountain Fire Protection District 4390 Eldorado Springs Drive Boulder, CO

Tents and Temporary Membrane Structures Packet

Fire District Dwelling Construction Requirements

Construction and Development Guide

Fire Protection Systems Plan Review

Appendix D Fire Safety Requirements

ST. LUCIE COUNTY FIRE DISTRICT FIRE PREVENTION CODE

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST

Residential Care Facilities Having 6 or Fewer Clients Classified in the California Building Code as R-3.1 Occupancies

Photovoltaic (Solar) Array Installation Guide

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

S000 SITE REVIEW APPR NO. FIRE CODE COMPLIANCE ITEM

Fire Department Fees.

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

FIRE CODE APPLICATION GUIDE FOR DEVELOPMENT IN UNINCORPORATED MULTNOMAH COUNTY

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

Sandwich Community Fire Protection District. Plan Review Submittal Guidelines and Requirements

GOLDEN FIRE DEPARTMENT FIRE & LIFE SAFETY DIVISION

Type BUILDING PERMITS Permits Fee Collected Valuation Units

Access Aisle (Van) (Flow Test) Water Mains (Location & Sizes) Building Entrances. Building, Facilities, Element. Curb Ramps (Built-up)

ATTACHMENT B FIRE CODE REQUIREMENTS FOR EXHIBITS AND SPECIAL EVENTS

TENTS AND TEMPORARY MEMBRANE STRUCTURES PERMIT PROCEDURE

2006 INTERNATIONAL FIRE CODE WITH PHOENIX AMENDMENTS

Type BUILDING PERMITS Permits Fee Collected Valuation Units

SPECIAL EVENTS INSTRUCTIONS AND REQUIREMENTS Must apply at least 2 weeks PRIOR to Event Date

City of Santa Monica Fee Schedule Effective July 1, 2012

South Davis Metro Fire Agency

COMMUNITY DEVELOPMENT SERVICES PLANNING AND BUILDING DEPARTMENT PLACERVILLE OFFICE:

DOUGLAS L. BARRY FIRE CHIEF

PLAN REVIEW FEES. Sprinkler Systems. NUMBER OF Without With SPRINKLERS Inspections Inspections

CLOVERDALE FIRE PROTECTION DISTRICT FEE SCHEDULE

Type BUILDING PERMITS Permits Fee Collected Valuation Units

Outdoor Festival and Special Event Guidelines

Large Family Daycare Guideline

Community Development Planning Division

HIGH-RISE RETROFIT ORDINANCES - NO and NO

South Elgin & Countryside Fire Protection District

FIRE PREVENTION STANDARDS

Planning Commission Application Summary

RESIDENTIAL FIRE SPRINKLER SYSTEMS POLICY

Permit Application Packet

CITY OF CYPRESS 5275 Orange Avenue Cypress, California (714) DESIGN REVIEW COMMITTEE PERMIT PROCESS

City of Laredo Building Development Services Department Monthly Report for May Type BUILDING PERMITS Permits Fee Collected Valuation Units Bldgs

FIRE PLAN CHECK FORM/CORRECTION List for Single Family Residences, Duplexes, and Garages

City of Vista Fire Department

CITY OF OKLAHOMA CITY SPECIAL EVENT REQUIREMENTS Revised January, 2011

Type BUILDING PERMITS Permits Fee Collected Valuation Units

FIRE PLAN CHECK CORRECTION List for Commercial Occupancies

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST STANDPIPE SYSTEMS

Secondary Suites. Guidelines for the construction of Accessory Secondary Suites in the City of Abbotsford August

The Home Ignition Zone

Transcription:

Meeks Bay Fire Protection District Plan Review - On-site Inspection - Fee Collection - Sign-Off Process Meeks Bay Fire reviews construction projects for compliance with California State Fire, Building, Residential Codes, El Dorado County Building Codes, Fire Codes and MBFPD Fire Code Amendments. The process may trigger several fees for Cost Recovery of work performed and/or Mitigation fees. Generally, the process involves the following steps: 1. Pre-TRPA defensible space and fire apparatus access submittal required by TRPA, as a result of Tahoe Fire Commission findings. Items reviewed include: Vegetation clearance types Fire apparatus access and roadway/driveway standards for width, height, clearance, slope, weight loading and radius curves. Length of the driveway with turnouts, with turnarounds. Fire hydrant access per the Section 7 of the California Fire Code, El Dorado County and MBFPD. Wet stamped plans are turned into TRPA and El Dorado County Building Department after the Pre-TRPA review. At that time, El Dorado County will issue a temporary building Permit. 2. After the El Dorado County Building Department review and comment, construction plans are dropped off at Meeks Bay Fire Station 61, located at 8041 Hwy 89 (Emerald Bay Road), Meeks Bay; between 0800 and 1600 Monday through Friday. The fire district will review and comment on the following areas: Building set-backs. Roof materials are CBC 7a compliant, without wood shake or shingle. Gas meter location and protection requirement per MBFPD Fire Code. Electric meter location and shut-off switch. Auto transfer electric generator has signage, disconnect/shunt switch. Driveway gates meet El Dorado County standard with fire apparatus access and Knox Box (gate key) entry. Fire sprinkler, Knox Box (house key), smoke and carbon monoxide detector requirements, per California Fire and Residential codes. If the project is an addition, increasing the project living, storage and garage space by 50% and 3000 square feet, residential sprinkler retrofit is required. 3. Plan Review and Developer fees are collected. 4. MBFPD staff will work with contractors and project managers during the pre- construction, plan check, sprinkler rough-in, sprinkler final, defensible space final and related inspections. Staff will access the El Dorado County Building Department computer system for various sign-offs. C:\Users\Shawn\Documents\Office\Forms\Plan Checks\0-Plan Review Information.wpd

Date: Fire & Life Safety Cost Recovery Schedule PO Box 189 ~ 8041 Hwy 89, Tahoma, CA 96142 (530) 525-7548 ~ Fax: (530) 525-4502 Hourly Rate is $80.00, unless noted otherwise Receipt # Project Title: Project Address: Contact: Telephone: Project Description: Building & Construction LAR Landscape/Access Residential Plan Check Pre-TRPA $ 160 DRC Design Review, Consultation (1 hr min.) Includes residential construction & remodels Includes commercial construction $ 80 DFS Developer Fees < 1,000 sq. ft. $ 250 DFL Developer Fees New Homes OR > 1,000 sq. ft. $ 500 LAC Landscape/Access Commercial Plan Check Pre-TRPA (3 hr min.) $ 240 ARI Additional Re-Inspection $ 120 PRE Request Staff Review and Participation in El Dorado Co. Pre-Development Meeting (2 hr min) $ 160 EPP Engineering (site) Plan Check $ 80 PRI PRS Pre-Inspections (care facilities, day cares) < 26 $ 80 Pre-Inspections (care facilities, day cares) > 26 $ 160 nd Re-submittal Fee for 2 Re-submittal and each Subsequent Re-submittal $ 80 TIP Tenant Improvement Plan Check $ 160 INV Investigations - 2 hr min. $ 160 EPR External Plan Review, Consultation, etc. 2 hr min. $ 160 Sprinkler & Fire Alarm System SPR Sprinkler Plan Check (Residential) - NEW 1-99 sprinklers $ 320 FAL Fire Alarm System Plan Check, # devices x $2 plus $ 220 SDP Standpipe Plan Check $ 360 SPA Sprinkler Plan Check - NEW, 1-99 sprinklers $ 360 SPB SPC STP STT UGS CAS Sprinkler Plan Check - NEW, 100-199 sprinklers, plus Number of Risers > 1 x 1 hour Floors > 1 x 1 hour Sprinkler Plan Check - NEW, > 199 sprinklers, # of Sprinklers x $0.50 plus Number of Risers > 1 x 1 hour Floors > 1 x 1 hour Sprinkler Plan Check (Tenant Improvement) - 5 to 50 sprinklers Sprinkler Plan Check (Tenant Improvement) - > 50 sprinklers Underground Fire Systems - per riser/hydrant > 1 x 1/4 hour plus Clean Agent Suppression System (Spray Booth/Industrial Dry Chemical Systems) $ 560 $ 760 $ 160 $ 240 $ 200 $ 300 HDP Hood & Duct System Plan Check (per system) $ 180 Events TNT Tents, Canopies, Temporary Structure Plan Check $ 160 FWK Fireworks (Pyrotechnic) $ 640 HHH Haunted House - Halloween Plan Check $ 80 CCF Carnivals, Concerts, Circus, Fairs - Basic Plan Check, plus $ 280 # of Booths x $6 plus TBU Temporary Bldg Use Fee (incl. Safety Officer if req d) $ 80 LPG & Tank Installation LPG Propane Tank Installation - Residential $ 160 UGT Underground Tank Installation - Residential $ 200 AGT Aboveground Tank Installation - Commercial [min) $ 160 EIR Environmental Impact Report (1 hour min) $ 80 FDS Fuel Dispensing Station(s) $ 160 Miscellaneous Fees DSI Defensible Space Inspection $ 80 WSL Will Serve Letter Processing Fee $ 80 REP Report Request: $0.50 per page varies $10 for photo CD CPY Fees Collected for Photocopying $0.50 per page varies TRP Tree Removal Permit $ 80 UGS Underground Fire Systems - per riser/hydrant $ 200 > 1 x 1/4 hour plus EBL El Dorado County Business License Insp. $ 80 PBP Paint or Spray Booth Plan Check $ 220 SMI State Mandated Fire Inspection (½ hr min) varies OSN Other Services Not Covered Above, misc. varies BP Burn Permit $ 20 Fire / EMS Fees Based on Accepted OES Rates DUI EMS Response for DUI varies FW Fire Watch (equipment & personnel) varies SR Search & Rescue varies Notes: Fee Paid $ Date Paid Check #

Meeks Bay Fire Protection District Procedures for Issuance of Fire District Approval Letter Required for an El Dorado County Building Permit Post Office Box 189 Tahoma, CA 96142 Lake Tahoe PHONE 530-525-7548 FAX 530-525-4502 Steve Simons, CHIEF BOARD OF DIRECTORS: Edward I. Miller Nicholas J. Kromydas Jane L. Warmack Bruce C. Massie Stephen W. Hyde Dear Developer/Builder/Remodeler: In an effort to streamline your project s approval with the Meeks Bay Fire Protection District requirements, we have created this checklist to assist you with our procedures. 1. On your initial visit to our office at 8041 Emerald Bay Road, please bring the following: Completed Application For Agency Approval For Building Permit Plans: Owner/Contractor to provide one set of plans for our records that includes: Site Plan, including the location and size (in gallons) of the LPG tank and gas lines, if applicable. Please show distance of the tank to structures, and property lines (must be greater than 10'). Also, please show the driveway slope by percentage. Site plan(s) will be returned to you upon approval. Roof Plan, depicting the ridge line and slope of the roof. Roofing material must be indicated on plan. Electrical Plan, including the locations of all smoke alarms. Floor Plan, including the sizes of all windows and locations. Elevations, including the location of the gas regulator/meter shed. The shed must be engineered, and the meter must be located on the gabled end of the building, greater than 3' from any operable window, electrical meter, and/or vent. 2. House numbers (not lot numbers) must be on house as per State and District fire codes. Please post six inch (6") numbers within twenty feet (20') of the road and in a contrasting color to the background. Numbers must be posted upon start of construction. 3. Plan Check and Developer fees are to be paid to the Meeks Bay Fire prior to issuance of the letter of approval required by the Building Department. 4. FINAL INSPECTION BY MEEKS BAY FIRE WILL BE REQUIRED. We will make every effort to process your application, plan check and final inspection as efficiently and quickly as possible. Please plan on a five day turn-around for plan checks and call us at least 72 hours in advance for final building inspections. Thank You C:\Users\Crawford\Documents\Office\Forms\Plan Checks\0-Checklist.wpd

Checklist for Determining Vegetation Parameters To Accomplish Defensible Space Please submit a minimum of two site plans for review (Meeks Bay Fire will retain one copy). The following parameters are to be used for determining Defensible Space needs from landscape plans for pre-approval of building permits before they are submitted to TRPA. Any final approval of Defensible Space will be made in the field, after snow has melted enough to determine compliance with PRC 4291. Please see CALFIRE s Guidelines for Creating Defensible Space at www.fire.ca.gov. This list does not represent an interpretation of any TRPA code. 1. All dead vegetation, including trees, brush and other biomass vegetation must be removed 100' from the structure or the to the property line. 2. All residual trees will be limbed to a height of ten feet (10') from the ground, on the highest side. This applies to trees that can be limbed without reducing the green canopy by more than 30%. If more than 30% of the live crown will be removed to achieve this limbing, then use the horizontal spacing guidelines listed for brush under #6 below and see spacing guidelines below for steeper slopes. 3. All residual trees will be limbed to achieve ten feet (10') of clearance from any part of the house to the branches of the tree. If less than 60% of the live crown is left after limbing, the tree should be removed. 4. All ladder fuels (brush, trees or flammable material) will be removed from under the drip line of residual trees or tree groups. 5. Within five feet (5') of the foundation or support posts of any part of the house or outbuilding, there will be no flammable material. 6. Within the five to thirty foot (5'-30') zone, tree canopies will be spaced at least ten feet (10') apart. If trees are grouped close enough together as to act as one unit, then all other requirements must be met. Within the 30-100 foot zone, stands of large trees do not have to be removed so long as the vegetation underneath them is removed. Please see spacing guidelines below for steeper slopes. 7. Within the five to thirty foot (5'-30') zone, brush fields must be spaced horizontally to a minimum distance equal or greater than two (2) times the height of the brush. Individual brush plants will not exceed 100 square feet in area and three feet (3') high. Please see spacing guidelines below for steeper slopes. For sloped properties, use the following standards for the above requirements: Trees Slope Spacing 0-20% 10 feet between edges of crowns 20-40% 20 feet between edges of crowns > 40% 30 feet between edges of crowns Brush 0-20% 2 times the height of residual brush 20-40% 4 times the height of residual brush > 40% 6 times the height of residual brush Meeks Bay Fire Protection District 8041 Hwy 89 - P.O. Box 189, Tahoma, CA 96142 Phone (530) 525-7548 - Fax (530)525-4502

Requirements for Meeks Bay Fire Protection District Pre-TRPA Submittal The following guidelines are to be used for all submittals to the Fire District for the Defensible Space Landscape Plans and Fire District Access Plans for Fire District pre-approval of building permits before they are submitted to TRPA. Please include all information for Defensible Space and Fire District Access on one sheet. Defensible Space & Fire District Access Minimum 18" x 24" sheet No larger than 2' contour lines All current and proposed structures on the property must be indicated All property boundaries must be indicated Scale indicated North Indicated Trees and vegetation, taller than 3', must be indicated Individual plants or brush fields, 20 square feet or larger in area must be indicated Drip lines of trees should be indicated Note any badly leaning, dying, or diseased trees within 50' of the structure (or boundary) All roads and driveways in, and abutting the property, must be indicated, along with lengths from road to structure Any current or proposed fire hydrants on the property must be indicated Initial review of residential driveways is done by El Dorado County Building Department Meeks Bay Fire Protection District 8041 Hwy 89 - P.O. Box 189, Tahoma, CA 96142 Phone (530) 525-7548 - Fax (530)525-4502