2 The RQPM & RQRM series of Package Heat Pumps are designed to be the most efficient, quickest to install, easiest to service, and most reliable units in the industry while still maintaining an affordable price. This platform provides you with a full line of nominal capacities from 2 through 5 tons. RQPM models are SEER and RQRM models are 5/ SEER, each AHRI-certified. Starting at the bottom, the base rails ( ) allow for separation between the unit base and the ground level, protecting the base from ground moisture and providing air circulation around the unit. Constructed from sturdy 8-gauge G-90 sheet metal, the base rails also allow for easier maneuverability during installation. As with all units offered by Ruud, we started our design process with input from the customer. From fan grille to the base rails, Ruud has combined 0 years worth of package unit design experience with input from Dealers to meet the latest application requirements. Rely on Ruud.
2 To provide flexibility in space-limited installations, the unit can be installed flush to the structure without blocking airflow over the outdoor coil or making any screws inaccessible for maintenance. Furthermore, the cabinet is a slim " wide. Full-louver coil protection ( 2 ) makes Ruud unique in the industry and also totally protects the outdoor coil from vandalism and weather extremes. Two round " duct collar ( ) are included with the unit, which makes attaching duct a snap. The collar is crimped around the leading edge, making it easier to install duct onto the collar. A metal bead around the circumference prevents the attached ducting from sliding off after installation. Keeping service technicians in mind, Ruud takes pride providing easy access to internal components. The outdoor-section top cover ( ) is easily removed to allow access to the scroll compressor ( 5 ), outdoor fan motor ( ), and refrigerant tubing ( 7 ). 5 7 Rely on Ruud.
9 The controls are located in a large, easy-to-access control box ( ), which provides plenty of space in which to troubleshoot. A demand defrost control ( 2 ) is used to manage the defrost cycle. The transformer ( ) is protected by a in-line fuse, which protects the transformer during a low-voltage electrical short. The lowvoltage ( ) and high-voltage ( 5 ) wiring connections are easily accessed and have ample room around which to maneuver. Troubleshooting is further aided with number- and color-coded wiring, which corresponds with the large, easy-to-read wiring diagram located on the inside of the control box access panel. 8 0 The indoor-section top cover also easily opens to access the removable blower housing and motor ( 8 ). This also gains total access to the indoor coil for cleaning and service ( 9 ). 2 The indoor motor and blower system will achieve nominal 00 CFM per ton up to a minimum of.8 inches of static pressure, which helps to eliminate customer dissatisfaction over poor airflow brought about by high-static duct designs. 5 Optional electric heat ( 0 ) can be easily installed in the field, with either dual- or single-point power, and is designed to easily install into the unit. Electric heat can also be specified as factory installed. 0 Rely on Ruud. 5
High and low pressure can easily and accurately be measured using the two gauge ports ( ) located inside the control box. Foil-faced insulation is securely glued and captured to the cabinet. On the base of the unit, closed-cell insulation is used to prevent moisture from being absorbed and help reduce mold content to provide better indoor air quality. For reliability and long-lasting operation, Ruud uses 00% scroll compressor technology ( 9 ) on all package platforms. With over 8 years of history, the scroll compressor has proven to be reliable, efficient, and quiet during operation. (Note: The RQRM- A00 uses a two stage scroll compressor). A small side panel grants access to a removable, sloped drain pan ( 7 ), which helps to ensure indoor air quality (IAQ) throughout the life of the unit. A /" drain trap ( 8 ) assembly is provided for convenience. 9 Patent 7,0,877 7 Low pressure control standard on all models ( 20 ). High pressure control standard on -00 model. 8 20 Rely on Ruud.
Model Number Identification R Q P M A 0 J K 00 Heating Capacity (Factory Installed) 000 = No Resistance Heat 005 = 05 KW Resistance Heat 007 = 07 KW Resistance Heat 00 = 0 KW Resistance Heat 05 = 5 KW Resistance Heat 020 = 20 KW Resistance Heat Drive Package K = Direct Drive Electrical Designation J = 208-20V PH 0 Hz C= 208-20V PH 0 Hz ( SEER Only) Nominal Cooling Capacity (BTUH) [kw] 02 = 2,000 [7.0] 00 = 0,000 [8.79] 0 =,000 [0.55] 07 =,000 [0.55] 02 = 2,000 [2.] 0 = 2,000 [2.] 08 = 8,000 [.07] 09 = 8,000 [.07] 00 = 0,000 [7.59] Future Technical Variations Design Series M = R-0A Efficiency Designation P = SEER R = 5/ SEER Product Classification Q= Package Heat Pump Tradebrand R= Ruud [ ] Designates Metric Conversions Rely on Ruud. 7
General Data RQPM Series NOMINAL SIZES 2-5 TONS [7-7. kw] Model RQPM- Series A02JK A00JK A0CK A0JK Cooling Performance Gross Cooling Capacity Btu [kw] 2,000 [7.0] 29,00 [8.],000 [0.55] CONTINUED,000 [0.55] EER/SEER 2 2/ 2.05/././ Nominal CFM/AHRI Rated CFM [L/s] 800/800 [78/78] 000/000 [72/72] 200/200 [5/5] 200/200 [5/5] AHRI Net Cooling Capacity Btu [kw] 2,00 [.9] 29,000 [8.5] 5,00 [0.7] 5,00 [0.7] Net Sensible Capacity Btu [kw] 8,00 [5.9] 2,000 [.7] 27,00 [8.09] 27,00 [8.09] Net Latent Capacity Btu [kw] 5,200 [.52],000 [.7] 7,800 [2.29] 7,800 [2.29] Net System Power kw.97 2..05.05 Heating Performance (Heat Pumps) Heating Input Btu [kw] Rating 2,200 [.8] 28,000 [8.2],200 [0.02],200 [0.02] System Power KW/COP.9/.5 2.27/.2 2.78/. 2.78/. Low Temp. Btuh [kw] Rating,200 [.87] 5,200 [.5] 9,000 [5.57] 9,000 [5.57] System Power KW/COP.7/2.2 2.0/2.22 2.8/2.2 2.8/2.2 HSPF (Btu/Watts-hr) 8.0 8.0 8.0 8.0 Compressor No./Type /Scroll /Scroll /Scroll /Scroll Outdoor Sound Rating (db) 7 7 7 7 Outdoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] OD 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m] 0. [0.97] 2.5 [.8] 2.5 [.8] 2.5 [.8] Rows / FPI [FPcm] / 20 [8] / 20 [8] / 20 [8] / 20 [8] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Indoor Coil Fin Type Louvered Louvered Louvered Louvered Tube Type Rifled Rifled Rifled Rifled Tube Size in. [mm] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] 0.75 [9.5] Face Area sq. ft. [sq. m]. [0.]. [0.]. [0.]. [0.] Rows / FPI [FPcm] 2 / 5 [] / [5] / [5] / [5] Refrigerant Control TX Valves TX Valves TX Valves TX Valves Drain Connection No./Size in. [mm] / [25.] / [25.] / [25.] / [25.] Outdoor Fan Type Propeller Propeller Propeller Propeller No. Used/Diameter in. [mm] /2 [09.] /2 [09.] /2 [09.] /2 [09.] Drive Type/No. Speeds Direct/ Direct/ Direct/ Direct/ CFM [L/s] 200 [50] 200 [50] 200 [50] 200 [50] No. Motors/HP at / HP at / HP at / HP at / HP Motor RPM 825 825 825 825 Indoor Fan Type FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No. Used/Diameter in. [mm] /0x9 [25x228.] /0x9 [25x228.] /0x9 [25x228.] /0x9 [25x228.] Drive Type/No. Speeds Direct/2 Direct/2 Direct/2 Direct/2 No. Motors Motor HP /2 /2 /2 /2 Motor RPM 050 050 050 050 Motor Frame Size 8 8 8 8 Filter Type Field Supplied Field Supplied Field Supplied Field Supplied Furnished No No No No (No.) Size Recommended in. [mm] ()x20x [25x508x0] ()x20x20 [25x508x508] ()x2x2 [25x0x0] ()x2x2 [25x0x0] Refrigerant Charge Oz. [g] 90 [2552] 9 [27] 9 [27] 9 [27] Weights Net Weight lbs. [kg] 08 [0] [50] 5 [] 5 [] Ship Weight lbs. [kg] 2 [5] 55 [] 80 [72] 80 [72] See Page 5 for Notes. [ ] Designates Metric Conversions 8 Rely on Ruud.
Electrical Data RQPM Series Evaporator Fan Condenser Motor Compressor Motor Unit Information Unit Operating Voltage Range Minimum Circuit Ampacity 87-25 2/2 Minimum Overcurrent Protection Device Size 0/0 0/0 Maximum Overcurrent Protection Device Size 5/5 5/5 No. Volts 208/20 208/20 Phase HP 2 2.5 RPM 50 50 Amps (RLA).5/.5./. Amps (LRA) 58./58. 7/7 No. Volts 208/20 208/20 Phase HP / / Amps (FLA).5.5 Amps (LRA) No. Volts 208/20 208/20 Phase HP /2 /2 Amps (FLA).. ELECTRICAL DATA RQPM SERIES -A02JK -A00JK -A0CK -A0JK -A07CK -A07JK -A02CK 87-25 2/2 87-25 9/9 208/20 50 0./0. 88/88 208/20 /.5 208/20 /2. 87-25 27/27 5/5 0/0 208/20 50.7/.7 79/79 208/20 /.5 208/20 /2. 87-25 9/9 208/20 50 0./0. 88/88 208/20 /.5/.5 / 208/20 /2./. 87-25 27/27 5/5 0/0 208/20 50.7/.7 79/79 208/20 /.5/.5 / 208/20 /2./. 87-25 2/2 0/0 5/5 208/20.5 50./. 95/95 208/20 /.9 208/20 / -A02JK 87-25 / 5/5 50/50 208/20.5 50 2.8/2.8 2/2 208/20 /.9 208/20 / Rely on Ruud.