NewsLetter Volume 24, No. 6

Similar documents
Easy Installation & Service

Commercial Gas Water Heaters

Commercial Gas Water Heaters

MECHANICAL VENTING VERSATILITY

ef Series Ultra High Efficiency Commercial Gas Water Heaters

Take Charge of Your Commercial Water Heating with the New Commander Series from Bradford White Bradford White s Commander Series The Commander Series

Commercial Gas Water Heaters

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

Newsletter. Western Michigan Chapter. Thoughts From Your Elected President... This months Meeting info: Date: September 11, 2013

Residential & Commercial

HIGH-EFFICIENCY COMMERCIAL GAS WATER HEATER 3-Year Tank Warranty 1-Year Parts Warranty

High Efficiency Commercial Gas Water Heaters

Commercial. Phoenix. up to 96% Efficient Commercial Water Heater. Advanced Heating & Hot Water Systems

Commercial. Phoenix. Advanced Heating & Hot Water Systems. 96% Efficient Commercial Water Heater

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

iq751/iq1001/iq1501 Specifications (Floor-standing units)

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

Up to 98% Thermal Efficiency CONDENSING COMMERCIAL GAS WATER HEATERS CONTROL WITH CASCADING SEQUENCER UP TO 98% THERMAL EFFICIENCY

Residential/Commercial Gas Condensing Tankless Models

Boilers Variable Fire Boilers

iq251, Gen II Submittal Data

Endless water. Zero waste. Commercial. High-output, on-demand water heaters. iq Series, Gen II

MAXIM. Power Combustion Storage Water Heater Gas, Oil or Combination Gas/Oil. 199 to 1200 MBH 125 and 250 Gallon Tanks 15-year Warranty. PVI.

Commercial Tankless Rack System

Advanced Heating & Hot Water Systems. High Efficiency Residential & Commercial Space Heating

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Automatic Circulating Water Heaters

Commercial Tankless Rack System

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

Highlights MBH 95% efficiency ENERGY STAR Qualified Low NOx emissions Space-saving design. 95% Efficient. Modulating Technology

FXLF-9. High Efficiency Water Heaters and Boilers

DEMAND DUO 80-GALLON HYBRID WATER HEATING SYSTEM SUBMITTAL SHEET

C1050ES Tankless Water Heater

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

Tankless Condensing High Efficiency Water Heaters

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Residential/Commercial Gas Tankless Water Heaters TANKLESS HIGH EFFICIENCY CONDENSING MODELS FEATURES INDOOR MODELS ATI-240H, ATI-340H, ATI-540H

iq1001, Gen II Submittal Data

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out!

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

POWER VTX. Condensing Storage Water Heater. 500 to 1000 MBH 225 Gallon Tank 15-year Warranty. PVI.com ENGINEERED DUPLEX ALLOY

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

Hydronic Air Handler Powered by Tankless Technology

AM Rapid Recovery Water Heaters

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

Commercial Tankless Rack System

C1210ES Tankless Water Heater

RHEEM WATER HEATERS

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Rheem Prestige Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Qualifies for up to $ 1500 Energy Tax Credit! CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ALL NEW, ADVANCED USER FEATURES

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

Commercial Tankless Rack System

ef Series Residential Condensing Power Vent Water Heaters

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

Suggested Specifications Prestige Excellence 110

UTICA BOILER. SSV Submittal. Project Name: Project Location: Contractor:

ULTRA SERIES 4 HIGH EFFICIENCY CONDENSING BOILER HIGH EFFICIENCY CONDENSING BOILER

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

DOM-5. Domestic Hot Water Heaters & Boilers

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

G215 G315 Cast Iron Residential Boilers

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

Rheem Classic Series Multi-position Gas Furnaces

Rheem Classic Plus Series Two Stage Multi position Gas Furnaces

Innovators in Waste to Energy Products

Residential Gas Tankless Water Heater

Models 1005, 1505, 2005 Up to 99% thermal efficiency!

Models 1005, 1505, Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

Utica Boilers MAC Submittal

DIVISION FINNED WATER-TUBE BOILERS

High Efficiency Commercial Gas Water Heaters

FOR 24/7 EXPERT SUPPORT PLEASE CALL: Technical Support: Warranty Support:

Product Brochure Water Heaters Tankless Gas WELC ME TO CONTINUOUS HOT WATER. Indoor and Outdoor Tankless Gas Water Heaters. Rheem.

RUUD HYBRID WATER HEATERS Super HP-SERIES. 2.0 energy factor FAST recovery EASYinstallation 40 & 50 gallon capacities ECOfriendly

DIVISION FINNED WATER-TUBE WATER HEATERS

Tankless Water Heaters

Project Name: Location: Engineer: Contractor: I. GENERAL

TANKLESS PRODUCT GUIDE CANADA TANKLESS PRODUCT GUIDE. A. O. Smith

BUDERUS. Quality. Versatility. Efficiency. Superior Design. Comfortable. Efficient. Intelligent Heating. Conventional Gas Boilers

FINNED WATER-TUBE POOL HEATERS

Date: Project #: Engineer: Prepared By: Bid Date:

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Hubbell NX500 High Efficiency Gas Condensing Water Heater

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY

Rheem Prestige Series Communicating Two Stage Variable Speed Multi position. Gas Furnaces

Rheem Prestige Series EcoNet Enabled Modulating Upflow Gas Furnaces

Raypak Residential Products

FINNED WATER-TUBE POOL HEATERS

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Series Two- Stage Multi-position Gas Furnaces. Ruud Achiever Plus. R96T- Series 96% A.F.U.E. * Input Rates from 40 to 115 kbtu [11.72 to 33.

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

Versatility 96 % ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO. DOE AFUE Efficiency.

ENGINEERED DUPLEX ALLOY

COMMERCIAL CONDENSING GAS WATER HEATER GALLONS, 55,000 BTU/HR 94% THERMAL EFFICIENCY

Transcription:

NewsLetter Volume 24, No. 6 Western Michigan Chapter THOUGHTS FROM YOUR ELECTED PRESIDENT... Upcoming Events: February 10, 2011 February 18, 2011 Griffin s Game March 10, 2011 Board Meeting 4:15 p.m. Social 5:00 p.m. Dinner 5:30 p.m. With Meeting to Follow Cost : $25 per meal February will be a busy ASPE month! We start off with our monthly meeting on the 10th (refer to Tom s article for topic) and then move on to our 2nd annual Griffins Hockey Game. This is a great time to socialize, and for you reps to get to know your engineers, soften them up for your sales calls and lunch and learns. Yes, engineers have hearts and will take time with you if you support them and their organization. Good time to ask for rep help in sponsoring the hockey night! I have asked Ashley to recognize and pay special attention to the sponsors in the newsletter. ASPE will have a sponsor board at the game. Will your firm s name be on it? Okay, okay, I'll stop. March will also have 2 meetings, our regular meeting on the 10th and a Mechanical & Plumbers Trade Show in Mount Pleasant. I will be there and make sure I take pictures of all the reps and their products for our newsletter. Hope to see you at the next meeting. Gordy

Volume 24, No. 6 VICE PRESIDENT LEGISLATIVE One anonymous reader writes: Page 2 I have received one code related e-mail for the Legislative Open Forum Column. I actually received this e-mail back in October but have been quite busy with deadlines at work and unable to find the time to put a column together the past few months. I apologize for my lack of attention to my column. I m still pretty busy but figured even if I can t find time to research and comment on the question I better get it posted so perhaps others may comment on it if they wish. After all, the original concept of the column was to post the questions and comments and have others submit their two cents.so here we go. What is the sizing method required as prescribed by the 2009 plumbing Code, paragraph 1003.3.1 through 1003.3.5.? How do we arrive at the flow rate and retention time for sizing outdoor interceptor? New code language exception: 500 gallon and larger outdoor interceptor shall not be required to meet chapter 10 This new exception will likely default to size selection that only meets minimum Grand Rapids ordinance requiring a 1000 volume interceptor. I do feel that it is proper to default on the selection of a concrete outdoor G.I. that only meets minimum 1000 gallon Grand Rapids city ordinance. Various Food Service Establishments, i.e., Mom & Pop 25-Seat Restaurant, Fast Food Restaurants, Schools, 300 Bed Prison, 500 Bed Hospital, University Student Union Centers and Large Banquet Halls do not have the same flow rate, kitchen equipment, building drain line size, etc. The cleaning intervals necessary for a 1000 gallon G.I. to meet the effluent quality of 100mg/L, as required by the same ordinance, would be much more costly to maintain than a larger passive grease interceptor that is engineered, tested and certified. Signed, ASPE WMC Member Not a very exciting pen name but a topic for good discussion. Please feel free to comment. As stated previously, you may remain anonymous if you prefer. Send comments and further discussion points to leathermanp@progressiveae.com Paula

Volume 24, No. 6 Page 3 Want to go to the February 18th Grand Rapids Griffin s game for free? Come to the February Meeting to hear more information! Friday nights are $1 Beer Nights @ the Griffin s!

Volume 24, No. 6 VICE PRESIDENT TECHNICAL For our meeting this month, we will be welcoming Chris Nutt from Airtech Equipment, Inc. and Bob Braam from Midwest Geothermal to discuss geothermal domestic water heating and snowmelt systems and how they can affect geothermal system operating dynamics and the financial ramifications of these systems. I am very excited to take advantage next month of the West Michigan Plumbers, Fitters and Service Trades Local Union No. 174 for a program on medical gas piping at their facility in Coopersville; they have extensive training programs on the medical gas field and the certifications for the installation of these systems. Tom 2010 2011 ASPE - Western Michigan Chapter Board and Committee Chairpersons PRESIDENT Gordon Berridge, CPD Applied Energy Engr. (616) 813-6203 glberridge@comcast.net VP LEGISLATIVE Paula Leatherman, CPD Progressive AE (616) 361-2664 x3231 leathermanp@progressiveae.com ADMINISTRATIVE SECRETARY Patrick Tanner Balfrey & Johnston, Inc. (616) 458-2266 pmtanner@balfrey-johnston.com VP TECHNICAL Tom Kingshott, CPD Hooker / DeJong, Inc. (231) 722-3407 tomk@hookerdejong.com VP MEMBERSHIP Ryan Fiebig GMB Architects Engineers (616) 796-0200 ryanf@gmb.com CORRESPONDING SECRETARY Dave Andrus Progressive Marketing & Sales (616) 916-4140 Andrus.Progressive@gmail.com VP EDUCATION Ashley Baker GMB Architects Engineers (616) 796-0200 ashleyb@gmb.com TREASURER Don Glennie, CPD GMB Architects-Engineers (616) 796-0200 donaldg@gmb.com BOARD ADDRESS: ASPE West Michigan P.O. Box 140341 Grand Rapids, MI 49514 ASPE Newsletter Editor Ashley Baker ASPEWestMichigan@gmail.com

Volume 24, No. 6 Page 5

Volume 24, No. 6 Page 6

RHEEM-RUUD COMMERCIAL WATER HEATERS Maximum delivery 460 gallons for one hour at 100 F rise 95% Thermal Efficiency Maximizes Energy Efficiency and Performance Dramatically reduces fuel costs Patented heat exchange system Eye level display for diagnostics and more! Commercial water heaters from Rheem-Ruud

SPIDERfire takes the bite out of fuel costs Rheem-Ruud INNOVATION SPIDERfire s unique multi-leg heat transfer system is where this new product gets its colorful name. The Rheem-Ruud line of condensing commercial water heaters offers a wide range of BTU inputs, all with ultra-high thermal efficiencies. The result is fuel savings and a higher recovery rate especially during periods of heavy use. The heart of the SPIDERfire is its patented heat-exchange system: a series of connected, elongated tubes immersed in the water tank and through which heat is transferred to the water. Generated by the burner at the top of the unit, combustion gases are blown down the large main flue in the center of the unit. The gases then traverse nearly the full length of the unit two more times, extracting as much heat energy as possible. By the end of the cycle, the temperature of the flue gases drops to between 110 F and 140 F and is cool enough for condensation to begin. Made in America Manufactured in Montgomery, Alabama, all SPIDERfire models come equipped with a 100- gallon storage tank and available in either natural gas or LP. Third-Party Tested The Rheem-Ruud SPIDERfire has been extensively tested by a third-party agency for water conditions and temperature, corrosive environments, dust and lint, increased cycling and venting configurations. Restaurants Hotels Laundromats Applications With its sleek modern design, the new SPIDERfire is engineered to deliver substantial amounts of hot water to meet the needs of larger commercial applications, such as restaurants, office buildings, schools, retail stores, and the like. SPIDERfire BENEFITS TO SPECIFYING ENGINEERS SPIDERfire offers ultra-high efficiency and energy savings. With up to a maximum delivery of 460 gallons, its performance will meet the needs of most businesses. Indoor air quality issues can be addressed by drawing combustion air from outside the building with a power direct vent installation. The SPIDERfire s small footprint reduces space requirements and long vent runs can be achieved through the use of low-cost PVC venting materials. TO CONTRACTORS SPIDERfire s narrow 26.25 inch diameter fits more easily down stairs and in tight places. Hot and cold water connections on both sides of the jacket provide flexibility during installation, especially during retro fits. The eye level status and diagnostic display is scrollable and reduces guess work, which helps speed up installation and service. Low-cost plastic venting materials can be used for power or power direct vent applications. TO FACILITIES MANAGERS Hot water is the second biggest energy user in most buildings, placing it right behind the HVAC system for energy costs. SPIDERfire s energy savings is an attractive solution to escalating costs. Because businesses often have heavy periods of hot water demand daily, SPIDERfire s ability to deliver up to 460 gallons for one hour helps keep you in business. In addition, the easy-to-read status and diagnostic display will help provide key information for fast installation and service. SPIDERfire s standard three year warranty can be increased to five years for additional piece of mind.

SPIDERfire s superb design is built to last Energy-efficient wet-base design SPIDERfire LCD diagnostic system provides scrollable diagnostics Rheem engineered a wet base for the lower portion of its flue system, suspending the first two legs of the flue network in water, rather than connecting them to the bottom of the tank. Hot spots are eliminated and the design also boosts efficiency heat is not lost through the bottom of the tank, as it is with a dry base design. Easier, less costly venting The cool temperatures of the flue gases permit venting through standard PVC or CPVC tubing. The low cost plastic venting means the contractor can install the product virtually anywhere, using almost any piping configuration. Depending on the model, an installer can use two-, three- or four-inch venting further lowering his costs and simplifying his installation. Power or power direct vent operation All models can be installed as a single-pipe, power-vented product; or as a two-pipe, power direct-vented product the latter for environments where negative air pressure or if indoor air quality is a concern. All inputs for SPIDERfire are available with ASME certification. Corrosion-protection SPIDERfire! Multi-leg heat exchanger system is porcelain coated inside and out Rheem coats the tubes inside and out with a specially formulated porcelain enamel designed to protect against the effects of condensation. Highly durable flue design The unique flue network of the SPIDERfire eliminates hot spots which can cause premature failure. It is built to last, even in heavy-commercial applications. OUR EXCLUSIVE FEATURES SPIDERfire LCD diagnostic system: This system is standard on all SPIDERfire units, enabling installers and service technicians to monitor key functions and components. LCD display is positioned at eye level offering easy-to-read status. The LCD s memory includes a scrollable, operational history to detail usage patterns and facilitate troubleshooting. Multiple water inlets and outlets: Two pairs of hot and cold water connections on either side of the water heater jacket provide installation flexibility, especially important in retrofit installations. Slim profile: Just 26.25 inches in diameter 1.5 to 2 inches smaller than competitive models the SPIDERfire fits more easily into tight commercial spaces. Full-port, full-flow brass drain valve factory installed: Allows for faster draining and servicing. Direct spark-to-flame ignition system Warranty: Standard three-year limited warranty can be upgraded to five years.

SPIDERfire Gas Specifications RECOVERY CAPACITIES MAXIMUM DELIVERY In U.S. Gallons/Hr. (GPH) and Liters/Hr. (LPH) at Various Temp. Rises In U.S. Gallons and Liters (Includes useable storage and recovery for indicated times) MODEL NUMBER MODEL NUMBER GAL. LITERS INPUT (BTU/HR) NAT. & LP THERMAL EFFICIENCY UNITS 100 F (56 C) 140 F (78 C) GHE100-130(A) 130,000 95% GPH LPH 150 567 107 405 GHE100-130(A) 100 379 130,000 100 F 56 C GHE100-160(A) 160,000 95% GPH LPH 184 698 132 499 GHE100-160(A) 100 379 160,000 GHE100-200(A) 199,000 95% GPH LPH 229 868 164 620 GHE100-200(A) 100 379 GHE100-250(A) 250,000 93% GPH LPH 282 1068 201 763 GHE100-250(A) 100 GHE100-300(A) 300,000 93% GPH LPH 338 1282 242 916 GHE100-300(A) GHE100-350(A) 350,000 92% GPH LPH 390 1479 279 1057 GHE100-350(A) INPUT (BTU/HR) TEMP. NAT. & LP RISE UNITS 5 MIN. 1 HR. MIN. TO RECOVER CONTENTS GAL LTR 83 313 220 833 39 100 F 56 C GAL LTR 85 323 254 964 33 199,000 100 F 56 C GAL LTR 89 338 299 1134 26 379 250,000 100 F 56 C GAL LTR 94 354 352 1333 21 100 379 300,000 100 F 56 C GAL LTR 98 372 408 1547 18 100 379 350,000 100 F 56 C GAL LTR 103 389 460 1745 15 All models have a maximum setpoint of 185 F. ZERO CLEARANCE TO COMBUSTIBLES DIMENSIONAL INFORMATION All dimensions shown in English and Metric MODEL NUMBER UNITS A B C D E F G H VENT WATER CONNECTIONS INLET OUTLET APPROX SHIP. WT. (LB) * Models with inputs of 130,000 through 199,000 BTU are certified to vent with 2" schedule 40 pvc, cpvc or abs pipe inches mm 78-3/4" 26-1/4" 66" 2001 667 1674 12-3/4" 325 73-3/4" 73-5/8" 72-7/16" 66-7/16" 2", 3", 4" 1873 1869 1839 1687 785 GHE100-160(A) inches mm 78-3/4" 2001 26-1/4" 66" 1674 12-3/4" 325 73-3/4" 73-5/8" 72-7/16" 66-7/16" 2", 3", 4" 1873 1869 1839 1687 785 GHE100-200(A) inches mm 78-3/4" 26-1/4" 66" 2001 667 1674 12-3/4" 325 73-3/4" 73-5/8" 72-7/16" 66-7/16" 2", 3", 4" 1873 1869 1839 1687 785 GHE100-250(A) inches mm 78-3/4" 26-1/4" 66" 2001 667 1674 12-3/4" 325 73-3/4" 73-5/8" 72-7/16" 66-7/16" 3", 4" 1873 1869 1839 1687 825 * Weights listed are for non-asme. Add 35 lbs. for ASME models. inches mm inches mm 78-3/4" 26-1/4" 66" 2001 667 1674 78-3/4" 26-1/4" 66" 2001 667 1674 12-3/4" 325 12-3/4" 325 73-3/4" 73-5/8" 72-7/16" 66-7/16" 3", 4" 1873 1869 1839 1687 73-3/4" 73-5/8" 72-7/16" 66-7/16" 3", 4" 1873 1869 1839 1687 GHE100-130(A) GHE100-300(A) GHE100-350(A) 667 825 130,000-199,000 BTU models are certified to be installed with 2" venting. 825 All models require a 120V power source. See use and care manual for venting details. GAS INLET EXHAUST AIR INTAKE Overall width is 27-5/16" due to exhaust cover INTAKE HOT OUT REAR T&P (For Canadian installations, please use ULC-S636 PVC and CPVC pipe.) HOT OUT FRONT EXHAUST A C F H G E TEMP SENSOR 31 COLD IN FRONT T&P DRAIN VALVE 31 42 41 TOP VIEW HAND HOLE CLEANOUT (With Optional Kit) DRAIN VALVE COLD IN REAR Complete specifications and venting information can be found on RR102C-18, SPIDERfire spec sheet. D B LEFT SIDE FRONT RIGHT SIDE (On Selected Models) REAR In keeping with its policy of continuous progress and product improvement, Rheem-Ruud reserves the right to make changes without notice. REPRESENTED BY: New Century Sales 1715 Traditional Dr Commerce Twp, MI 48390 Office: 248-960-1149 Michael Zago Cell: 616-293-2121 mikez@newcenturysales.com Commercial water heaters from Rheem-Ruud Rheem Heating, Cooling & Water Heating 101 Bell Road, Montgomery, AL 36117-4305 800-621-5622 sales@rheem.com www.rheem.com Rheem Canada Ltd./Ltée Water Heater Division 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5 Not all models are available in Canada. Printed in U.S.A 02/10 WP RR-180

SPIDERfire Sealed-Combustion Gas-Fired Commercial Water Heaters 100 Gallon Model 130,000 BTU/Hr. thru 350,000 BTU/Hr. 92-95% thermal efficiency Rheem-Ruud SPIDERfire Gas Commercial Water Heaters are specifically designed to provide customers with maximum savings on operation, space and installation. Designed with the most advanced technology available, these products optimize efficiency and operating reliability. Construction Features: Maximum thermal efficiency of 95% dramatically reduces operating costs No chimney required; power or direct vent using plastic pipe Low NOx emissions. Meets SCAQMD Rule 1146.2 Corrosion resistant, high efficiency 3-pass heat exchanger Self-diagnostic LCD electronic control Direct spark ignition 185 F maximum temperature setting Zero clearance to all combustible surfaces Full flow drain valve Front and back water connectioins Factory installed AGA/ASME rated T&P relief valve No Chimney Required Vents Up To 60 Feet Using 3" And Up To 85 Feet Using 4" Schedule 40 PVC, CPVC or ABS Pipe 130,000 BTU thru 199,000 BTU Models Are Certified To Vent With 2" Schedule 40 PVC, CPVC or ABS Pipe (For Canadian installations, please use ULC-S636 PVC and CPVC pipe.) Certifications and Ratings: Efficiency these models have been tested according to ANSI test procedures, and meet or exceed the thermal efficiency and standby loss requirements of current ASHRAE standard (Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy efficiency codes of all states including California Energy Commission (CEC). Safety and construction these products are design certified by the CSA: a) For operation at 185 F. b) To meet all safety and construction requirements of ANSI Z21.10.3. c) As an automatic storage or instantaneous water heater. d) As an automatic circulating tank water heater. e) For operation on combustible floors and in alcove installations. All models are North Carolina Code compliant. CERTIFIED FOR A 150 PSI MAXIMUM WORKING PRESSURE (160 PSI FOR ASME MODELS). Optional constructions ASME construction is available on designated models. UL Sanitation (NSF5) compliant models are available when equipped with optional seal kit. (Part No. AS42690) (On Selected Models) (With Optional Kit) Continued next page.

SPIDERfire Gas continued. RECOVERY CAPACITIES Recovery in U.S. Gallons/Hr. (GPH) and Liters/Hr. (LPH) at Various Temperature Rises MODEL INPUT (BTU/HR) THERMAL 40 F 50 F 60 F 70 F 80 F 90 F 100 F 110 F 120 F 130 F 140 F NUMBER NAT. & LP EFFICIENCY UNITS (22 C) (28 C) (33 C) (39 C) (45 C) (50 C) (56 C) (61 C) (67 C) (72 C) (78 C) GHE100-130(A) 130,000 95% GHE100-160(A) 160,000 95% GHE100-200(A) 199,000 95% GHE100-250(A) 250,000 93% GHE100-300(A) 300,000 93% GHE100-350(A) 350,000 92% GPH 374 299 249 214 187 166 150 136 125 115 107 LPH 1418 1135 946 811 709 630 567 516 473 446 405 GPH 461 368 307 263 230 205 184 167 154 142 132 LPH 1746 1397 1164 998 873 776 698 635 582 537 499 GPH 573 458 382 327 286 255 229 208 191 176 164 LPH 2171 1737 1447 1241 1086 965 868 790 724 668 620 GPH 705 564 470 403 352 313 282 256 235 217 201 LPH 2670 2136 1780 1526 1335 1187 1068 971 890 822 763 GPH 845 676 564 483 423 376 338 307 282 260 242 LPH 3204 2563 2136 1831 1602 1424 1282 1165 1068 986 916 GPH 976 781 651 558 488 434 390 355 325 300 279 LPH 3698 2958 2465 2113 1849 1644 1479 1345 1233 1138 1057 MAXIMUM DELIVERY In U.S. Gallons and Liters (Includes useable storage and recovery for indicated times) MODEL INPUT (BTU/HR) TEMP. 5 10 15 20 30 45 1 2 3 MIN. TO RECOVER NUMBER GAL. LITERS NAT. & LP RISE UNITS MIN. MIN. MIN. MIN. MIN. MIN. HR. HR. HR. CONTENTS GHE100-130(A) 100 379 130,000 GHE100-160(A) 100 379 160,000 GHE100-200(A) 100 379 199,000 GHE100-250(A) 100 379 250,000 GHE100-300(A) 100 379 300,000 GHE100-350(A) 100 379 350,000 All models have a maximum setpoint of 185 F. 100 F GAL. 83 95 107 120 145 185 220 369 519 56 C LTR. 313 360 407 454 549 700 833 1400 1967 100 F GAL. 85 101 116 131 162 208 254 438 623 56 C LTR. 323 382 440 498 614 789 964 1662 2360 100 F GAL. 89 108 127 146 185 242 299 528 757 56 C LTR. 338 410 482 555 700 917 1134 2002 2871 100 F GAL. 94 117 141 164 211 281 352 634 916 56 C LTR. 354 443 532 621 799 1066 1333 2402 3470 100 F GAL. 98 126 155 183 239 324 408 746 1085 56 C LTR. 372 479 586 693 906 1227 1547 2829 4110 100 F GAL. 103 135 168 200 265 363 460 851 1241 56 C LTR. 389 512 635 758 1005 1375 1745 3224 4703 39 33 26 21 18 15 DIMENSIONAL INFORMATION All dimensions shown in English and Metric MODEL WATER CONNECTIONS APPROX. NUMBER UNITS A B C D E F G H VENT INLET OUTLET SHIP. WT. (LB)* GHE100-130(A) GHE100-160(A) GHE100-200(A) GHE100-250(A) GHE100-300(A) GHE100-350(A) inches 78-3/4" 26-1/4" 66" 12-3/4" 73-3/4" 73-5/8" 72-7/16" 66-7/16" 2", 3", 4" 785 mm 2001 667 1674 325 1873 1869 1839 1687 inches 78-3/4" 26-1/4" 66" 12-3/4" 73-3/4" 73-5/8" 72-7/16" 66-7/16" 2", 3", 4" 785 mm 2001 667 1674 325 1873 1869 1839 1687 inches 78-3/4" 26-1/4" 66" 12-3/4" 73-3/4" 73-5/8" 72-7/16" 66-7/16" 2", 3", 4" 785 mm 2001 667 1674 325 1873 1869 1839 1687 inches 78-3/4" 26-1/4" 66" 12-3/4" 73-3/4" 73-5/8" 72-7/16" 66-7/16" mm 2001 667 1674 325 1873 1869 1839 1687 inches 78-3/4" 26-1/4" 66" 12-3/4" 73-3/4" 73-5/8" 72-7/16" 66-7/16" mm 2001 667 1674 325 1873 1869 1839 1687 inches 78-3/4" 26-1/4" 66" 12-3/4" 73-3/4" 73-5/8" 72-7/16" 66-7/16" mm 2001 667 1674 325 1873 1869 1839 1687 3", 4" 825 3", 4" 825 3", 4" 825 0" CLEARANCE TO COMBUSTIBLES MODELS WITH INPUTS OF 130,000 BTU THRU 199,000 BTU ARE CERTIFIED TO VENT WITH 2" SCHEDULE 40 PVC, CPVC OR ABS PIPE (FOR CANADIAN INSTALLATIONS, PLEASE USE ULC-S636 PVC AND CPVC PIPE.) * Weights listed are for non-asme. Add 35 lbs. for ASME models. 130,000-199,000 BTU models are certified to be installed with 2" venting. All models require a 120V power source. See use and care manual for venting details. Overall width is 27-5/16" due to exhaust cover

SPIDERfire Gas continued. VENTING OPTIONS Power Direct Vent Power Vent PIPE DIAMETER PIPE DIAMETER PIPE DIAMETER PIPE DIAMETER PIPE DIAMETER PIPE DIAMETER 2" 3" 4" 2" 3" 4" MODEL NUMBER MAX. VENT LENGHT FOR INLET OR OUTLET (FT.) MODEL NUMBER MAX. VENT LENGHT FOR OUTLET (FT.) GHE100-130 20 60 85 GHE100-130 20 60 85 GHE100-160 20 50 75 GHE100-160 20 50 75 GHE100-200 20 40 65 GHE100-200 20 40 65 GHE100-250 40 65 GHE100-250 40 65 GHE100-300 40 40 GHE100-300 40 40 GHE100-350 40 40 GHE100-350 40 40 For each 90 elbow, reduce pipe length by five (5) feet. For each 45 elbow, reduce pipe length by two and a half (2.5) feet. Note: Vent pipe size should not be mixed for venting these units. Use same diameter pipe for all venting of the unit. Example of Venting for 2" Power Direct Vent Setup: Refer to the chart above, Power Direct Vent, for actual length allowed on each model. NUMBER OF 90 ELBOWS NUMBER MINIMUM VENT MAXIMUM VENT EXCLIUDING VENT TERMINALS OF 45 PIPE LENGTH PIPE LENGTH INLET VENT OUTLET VENT ELBOWS IN FEET IN FEET None None None 5.0 20.0 One (1) One (1) None 15.0 One (1) One (1) One (1) 12.5 Two (2) Two (2) None 10.0 Two (2) Two (2) One (1) 7.5 Three (3) Three (3) None 5.0 Three (3) Three (3) One (1) 2.5 Example of Venting for 4" Power Direct Vent Setup (GHE100-130): Refer to the chart above, Power Direct Vent, for actual length allowed on each model. The 3" venting will follow the same format. See allowable lengths above. NUMBER OF 90 ELBOWS NUMBER MINIMUM VENT MAXIMUM VENT EXCLIUDING VENT TERMINALS OF 45 PIPE LENGTH PIPE LENGTH INLET VENT OUTLET VENT ELBOWS IN FEET IN FEET None None None 5.0 85.0 One (1) One (1) None 80.0 One (1) One (1) One (1) 77.5 Two (2) Two (2) None 75.0 Two (2) Two (2) One (1) 72.5 Three (3) Three (3) None 70.0 Three (3) Three (3) One (1) 67.5 Four (4) Four (4) None 65.0 Four (4) Four (4) One (1) 62.5 Five (5) Five (5) None 60.0 For each 90 elbow, reduce pipe length by five (5) feet. For each 45 elbow, reduce pipe length by two and a half (2.5) feet. Note: Vent pipe size should not be mixed for venting these units. Use same diameter pipe for all venting of the unit. Example of Venting for 2" Power Vent Setup: Refer to the chart above, Power Vent, for actual length allowed on each model. NUMBER OF 90 ELBOWS NUMBER MINIMUM VENT MAXIMUM VENT EXCLIUDING VENT TERMINALS OF 45 PIPE LENGTH PIPE LENGTH OUTLET VENT ELBOWS IN FEET IN FEET None None 5.0 20.0 One (1) None 15.0 One (1) One (1) 12.5 Two (2) None 10.0 Two (2) One (1) 7.5 Three (3) None 5.0 Three (3) One (1) 2.5 Example of Venting for 4" Power Vent Setup (GHE100-130): Refer to the chart above, Power Vent, for actual length allowed on each model. The 3" venting will follow the same format. See allowable lengths above. NUMBER OF 90 ELBOWS NUMBER MINIMUM VENT MAXIMUM VENT EXCLIUDING VENT TERMINALS OF 45 PIPE LENGTH PIPE LENGTH OUTLET VENT ELBOWS IN FEET IN FEET None None 5.0 85.0 One (1) None 80.0 One (1) One (1) 77.5 Two (2) None 75.0 Two (2) One (1) 72.5 Three (3) None 70.0 Three (3) One (1) 67.5 Four (4) None 65.0 Four (4) One (1) 62.5 Five (5) None 60.0 NOTE: For Canadian installations, use ULC-S636 PVC and CPVC pipe. Limited Warranty This product features a three year limited warranty against tank leaks. Please refer to Commercial Warranty Information brochure for complete warranty information. Commercial water heaters from Rheem-Ruud

SPIDERfire Gas continued. DIMENSIONAL INFORMATION AIR INTAKE GAS INLET EXHAUST T&P HOT OUT REAR INTAKE HOT OUT FRONT A COLD IN FRONT C H F G HAND HOLE CLEANOUT E EXHAUST TEMP SENSOR 31 41 31 42 T&P DRAIN VALVE D DRAIN VALVE COLD IN REAR TOP VIEW LEFT SIDE B FRONT RIGHT SIDE REAR Recommended Specifications (for trade reference only) Water heater(s) shall be SPIDERfire model, manufactured by RHEEM-RUUD, having a gas input of Btu/hr. and recovery rate of GPH at a 100 F temperature rise when tested and certified at thermal efficiency. Water heater(s) shall have a storage capacity of gallons. Water heater(s) shall have the CSA seal of certification and supplied with a factory installed AGA/ASME rated temperature and pressure relief valve, and meet SCAQMD Rule 1146.2. Tank(s) shall be of wet-base design and furnished with U.S. Patent 7,290,503 B2 heat exchange system with two-sided coating of high temperature porcelain enamel and furnished with magnesium anode rods rigidly supported. Water heater(s) shall have 2 NPT front and rear water connections. Water heater(s) shall meet or exceed thermal efficiency and standby loss requirements of ASHRAE. Tanks shall have a working pressure of 150 psi and shall be completely factory assembled, including a pressure regulator properly adjusted for operation on gas with a down-fired burner system. Water heater(s) shall certified for schedule IV venting with power vent and powered direct vent options. Water heater(s) shall be covered by a three year limited tank warranty against tank leaks. Add for ASME construction Water heater(s) shall be constructed in accordance with the requirements of the ASME Boiler and Pressure Vessel Code, Section IV Part HLW. REPRESENTED BY: New Century Sales 1715 Traditional Dr Commerce Twp, MI 48390 Office: 248-960-1149 Michael Zago Cell: 616-293-2121 mikez@newcenturysales.com Commercial water heaters from Rheem-Ruud In keeping with its policy of continuous progress and product improvement, Rheem-Ruud reserves the right to make changes without notice. Rheem Water Heating 101 Bell Road, Montgomery, Alabama 36117-4305 www.rheem.com Rheem Canada Ltd./Ltée,125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5 P R I N T E D I N U. S. A 0 1 / 1 0 W P RR102C-18