Chapter 5 Heat-transfer Equipment

Similar documents
Evaporation System: Types and Design Aspects

2. HEAT EXCHANGERS MESA

Heat Exchangers. Heat Exchangers 1

2. PROCESS DESIGN OF SHELL AND TUBE EXCHANGER FOR TWO PHASE HEAT TRANSFER

Gandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

All rights reserved, Armando B. Corripio, PhD, PE, Solid Dryer Design Introduction Continuous Dryer Design...

Mechanical Engineering Department Sheet (1)

Heat Transfer Equipments

Heat exchangers are devices that facilitate the exchange of heat between

Experimental Investigation of Tube Configuration for a Surface Condenser

How is the heat transfer?

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

Chapter 10. Refrigeration and Heat Pump Systems

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

Falling Film Heat Exchangers for Solar Water Heaters

The Condensate Water Systems

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System


As we discussed early in the first chapter that heat can transfer through materials and the surrounding medium whenever temperature gradient exists

Refinery Vacuum Towers. State of the Art. (Extended Abstract)

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

CHAPTER 8 EVAPORATION. The basic factors that affect the rate of evaporation are the:

In the name of God. Jami Institute of Jami - Mehdi Rasti

Homework Chapter2. Homework Chapter3

Techniques of Heat Transfer Enhancement and their Application. Chapter 4. Performance Evaluation Criteria for Two-Phase Heat Exchangers

Some Heat Transfer Problems. A hydrocarbon oil (mean heat capacity = 0.50 BTU/(lb m

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

Steam Power Cycles Part II

CHAPTER 7 COMPARISON OF HEAT EXCHANGERS

Jurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015

For an ideal gas mixture, Dalton s law states that the sum of the partial pressures of the individual components is equal to the total pressure.

Experimental Investigation Of A New Low- Approach Evaporator With Reduced Refrigerant Charge

Physical Mechanism of Convection. Conduction and convection are similar in that both mechanisms require the presence of a material medium.

THE GATE COACH All Rights Reserved 28, Jia Sarai N.Delhi-16, ,-9998

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Chapter 14, Problem 27.

Thermodynamics: Homework A Set 7 Jennifer West (2004)

[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

Homework #4 (group) Tuesday, 27 by 4:00 pm 5290 exercises (individual) Tuesday, 27 by 4:00 pm extra credit (individual) Tuesday, 27 by 4:00 pm

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS

ENSC 388: Engineering Thermodynamics and Heat Transfer

ME Mechanical Engineering Systems Laboratory. Experiment 3 - Mass and Energy Balances in Psychrometric Processes

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Modelling of divided wall column

Integral effects 567 Iron oxide deposition 462. Kettle Reboiler Modelling 732

Lecture # 5: SOLVED PROBLEM

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

HEAT EXCHANGER FORMULAS & EXAMPLE

Modeling of a regenerative indirect evaporative cooler for a desiccant cooling system

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Heat transfer property of refrigerant-oil mixture in a flooded evaporator: The role of bubble formation and oil retention

TROUBLESHOOT PACKING MALDISTRIBUTION UPSET PART 2: BOILING AND FLASHING IN PACKED TOWER DISTRIBUTORS

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

Efficiency of Application the Condensing Heat Utilizers in the Existing Boiler's Unit in Heat Power Station

Pressure Enthalpy Charts

Shalaby Institute of Fire Protection Heyrothsberge, Germany.

Experimental Measurement of Water Evaporation Rates Into Air and Superheated Steam

J. LINES, Graham Corp., Batavia, New York

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Introduction to Material and Energy Balance

There are a number of factors in a process which may result in liquid entrainment. Some of the commonly observed causes are discussed below.

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

MECHANICAL ENGINEERING ME.2017 FUNDAMENTAL OF REFRIGERATION AND AIR CONDITIONING. Sample Questions and Answers

EXPERIMENTAL EVALUATION OF CONDENSATION HEAT TRANSFER COEFFICIENT OF R-417A IN HORIZONTAL TUBES

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

Yogesh B Desale, J. H. Bhangale. Abstract

International Association of Certified Practicing Engineers

Steam Site Guide. Steam Site Guide. Heat Exchange Applications - SI Units

Investigation of Multiple Effect Evaporator Design

Eliminating Condensation and Resulting Corrosion. Sulphur Tail Gas and De-Gas Lines

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

A Comparison Between Refrigerants Used In Air Conditioning

Sant Gadge Baba Amravati University. Amravati, Maharashtra, India, Maharashtra 2

Shortcut Model for Predicting Refrigeration Cycle Performance

Water Cooled Condenser Using Nano Fluids

Agitation and Mixing

The theory behind heat transfer

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

A Thermal Assessment for Vertical Helical Immersion Coil Evaporator in a Water Chiller

Experimental correlation of falling film condensation on enhanced tubes with HFC134a; low-fin and Turbo-C tubes

Heat Transfer Equipment Overview Core COPYRIGHT. Types of Heat Exchangers and Their Common Applications in Oil and Gas Processing Facilities

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

Module 3: Liquid Fossil Fuel (Petroleum) Lecture 25: Refinery Equipments

Evaporators. Direct Expansion Flooded Recirculated Over Feed

Design of Flat-Plate Dehumidifiers for Humidification Dehumidification Desalination Systems

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Introduction to Heat Exchangers

Paper No. : 04 Paper Title: Unit Operations in Food Processing Module- 14:Evaporation

Chapter 9. Refrigeration and Liquefaction

Process Simulation and Optimization of Cryogenic Operations Using Multi-Stream Brazed Aluminum Exchangers

Exhaust. a) For an arbitrary ambient temperature develop an expression for Q chiller in terms of M amb and M total.

SHELL AND TUBE HEAT EXCHANGER (STHE) - part b

APPLICATION OF HYDROCARBON REFRIGERANTS IN LOW TEMPERATURE CASCADE SYSTEMS

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

Postprint.

Transcription:

Chapter 5 Heat-transfer Equipment

1. Condenser Four condenser configurations are possible: 1. Horizontal, with condensation in the shell, and the cooling medium in the tubes. 2. Horizontal, with condensation in the tubes. 3. Vertical, with condensation in the shell. 4. Vertical, with condensation in the tubes. Horizontal shell-side and vertical tube-side are the most commonly used types of condenser. A horizontal exchanger with condensation in the tubes is rarely used as a process condenser, but is the usual arrangement for heaters and vaporizers using condensing steam as the heating medium.

1. Condensation outside horizontal tubes

1. Condensation outside horizontal tubes In a bank of tubes the condensate from the upper rows of tubes will add to that condensing on the lower tubes. If there are N r tubes in a vertical row and the condensate is assumed to flow smoothly from row to row, Figure 12.42a, and if the flow remains laminar, the mean coefficient predicted by the Nusselt model is related to that for the top tube by: In practice, the condensate will not flow smoothly from tube to tube, Figure 12.42b, and the factor of Nr -1/4 applied to the single tube coefficient in equation 12.49 is considered to be too conservative. Based on results from commercial exchangers, Kern (1950) suggests using an index of 1/6. Frank (1978) suggests multiplying single tube coefficient by a factor of 0.75.

1. Condensation outside horizontal tubes

1. Condensation outside horizontal tubes Using Kern s method, the mean coefficient for a tube bundle is given by: For low-viscosity condensates the correction for the number of tube rows is generally ignored. A procedure for estimating the shell-side heat transfer in horizontal condensers is given in the Engineering Sciences Data Unit Design Guide, ESDU 84023.

2. Condensation inside and outside vertical tubes For condensation inside and outside vertical tubes the Nusselt model gives: For a tube bundle: Equation 12.51 will apply up to a Reynolds number of 30; above this value waves on the condensate film become important. The Reynolds number for the condensate film is given by:

2. Condensation inside and outside vertical tubes Above a Reynolds number of around 2000, the condensate film becomes turbulent. The effect of turbulence in the condensate film was investigated by Colburn (1934) and Colburn s results are generally used for condenser design, Figure 12.43. Equation 12.51 is also shown on Figure 12.43. The Prandtl number for the condensate film is given by:

Figure 12.43 can be used to estimate condensate film coefficients in the absence of appreciable vapor shear. Horizontal and downward vertical vapor flow will increase the rate of heat transfer, and the use of Figure 12.43 will give conservative values for most practical condenser designs. Boyko and Kruzhilin (1967) developed a correlation for shear-controlled condensation in tubes which is simple to use. Their correlation gives the mean coefficient between two points at which the vapor quality is known. The vapor quality x is the mass fraction of the vapor present. It is convenient to represent the Boyko-Kruzhilin correlation as: Where: and the suffixes 1 and 2 refer to the inlet and outlet conditions respectively. h' i is the tubeside coefficient evaluated for single-phase flow of the total condensate (the condensate at point 2).

Boyko and Kruzhilin used the correlation: In a condenser the inlet stream will normally be saturated vapor and the vapor will be totally condensed. For these conditions equation 12.52 becomes: For the design of condensers with condensation inside the tubes and downward vapor flow, the coefficient should be evaluated using Figure 12.43 and equation 12.52, and the higher value selected.

Example Estimate the heat-transfer coefficient for steam condensing on the outside, and on the inside, of a 25 mm o.d., 21 mm i.d. vertical tube 3.66 m long. The steam condensate rate is 0.015 kg/s per tube and condensation takes place at 3 bar. The steam will flow down the tube. Solution Physical properties, from steam tables:

vertical tube loading

Example It is proposed to use an existing distillation column, which is fitted with a dephlegmator (reflux condenser) which has 200 vertical, 50 mm i.d., tubes, for separating benzene from a mixture of chlorobenzenes. The top product will be 2500 kg/h benzene and the column will operate with a reflux ratio of 3. Check if the tubes are likely to flood. The condenser pressure will be 1 bar. Solution The vapor will flow up and the liquid down the tubes. The maximum flow rates of both will occur at the base of the tube.

Tubes should not flood, but there is little margin of safety.

Example Design a condenser for the following duty: 45,000 kg/h of mixed light hydrocarbon vapors to be condensed. The condenser to operate at 10 bar. The vapor will enter the condenser saturated at 60 C and the condensation will be complete at 45 C. The average molecular weight of the vapors is 52. The enthalpy of the vapor is 596.5 kj/kg and the condensate 247.0 kj/kg. Cooling water is available at 30 C and the temperature rise is to be limited to 10 C. Plant standards require tubes of 20 mm o.d., 16.8 mm i.d., 4.88 m (16 ft) long, of admiralty. The vapors are to be totally condensed and no sub-cooling is required. Solution Only the thermal design will be done. The physical properties of the mixture will be taken as the mean of those for n-propane (MW = 44) and n-butane (MW = 58), at the average temperature.

Assumed overall coefficient (Table 12.1) = 900 W/m 2 C Mean temperature difference: the condensation range is small and the change in saturation temperature will be linear, so the corrected logarithmic mean temperature difference can be used.

Try a horizontal exchanger, condensation in the shell, four tube passes. For one shell pass, four tube passes, from Figure 12.19, F t = 0.92.

Significantly lower than the assumed value of 900 W/m 2 C. Repeat calculation using new trial value of 750 W/m 2 C.

Close enough to estimate, firm up design.

Shell-side pressure drop Use pull-through floating head, no need for close clearance. Select baffle spacing = shell diameter, 45 per cent cut. From Figure 12.10, clearance =95 mm.

Shell-side pressure drop Negligible; more sophisticated method of calculation not justified.

Tube-side pressure drop acceptable.