CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Similar documents
CM-RQE70 PIR REQUEST TO EXIT DETECTOR

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

DS160/161 Request To Exit PIR sensors Installation Instructions

DS160/DS161 Request To Exit PIR sensors Installation Instructions

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

Installation Instructions

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

STANDARD FEATURES SPECIFICATIONS

SP-1000X. Panic Device Power Controller Installation Guide. Rev

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Addendum for STI-6406 with Dual Access Control

WIRING DIAGRAM AND INSTRUCTIONS

Installation & Operations Manual

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

705 Emmett Street Bristol, CT DynaLock MODEL 3101C-TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS

DOLKPL1KB DOLKPS1KB DOLKSF1KB

DOLKPS1KB Programming & Installation Manual

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

DE5300 Delayed Egress System. General Information

LS800S Intruder Alarm System. Engineering Manual

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

Remote Chexit Module (RCM) System. General Information

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

EXTINGUISHING AGENT RELEASE MODULE

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Section 1 General Description

KP-100A BACKLIT DIGITAL KEYPAD FOR ELECTRIC LOCK AND SECURITY SYSTEM INSTALLATIONS

Installation Guide for models:

NetworX NX-548E Receiver Installation Instructions

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD AND CARD READER

Wireless D.I.Y. Alarm Kit

Honeywell ENERGY SAVINGS KIT

MR-2602 Two Zone Fire Alarm Control Panel

Installation, Operating and Maintenance Manual

HAA2866 HAA2866 ERRATUM

SECTION INTRUSION DETECTION

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE SYSTEM. HANDLE THE EQUIPMENT CAREFULLY.

Beacon 800 Gas Monitor Operator s Manual

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

4700 SERIES PLC INTERLOCK CONTROLLER

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

OPTICAL TURNSTILE SYSTEM

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

General Purpose IO Technical Manual

MANUAL RESET ALARM RELEASE

Power Transfer Devices. Access Control Accessories. How To Order. How to Order

Premium 8 Zone Wireless Alarm Kit

Series. Access Power Controllers. Installation Guide

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

RMS/RPX Reader. User Manual

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

MODEL B2 INSTALLATION MANUAL

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

SPLIT-DECODED CONTROLLER

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Installation Instructions

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

DYGIZONE GJD910 Lighting Controller & Enunciator

ACM4 Series UL Listed Sub-Assembly Access Power Controllers

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

FMR Installation Instructions. Addressable Fire System Controller

English. Italiano. Português. Françias. Español

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Reflective Optical Beam Smoke Detector User Guide

HX-80NRAM. High Mount Outdoor Detector

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Ethernet General Purpose

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

LUX Hardwired - Installation Notes

Installation & User Manual V1.1

Caliber Series LED Edgelit Exit Sign EXPORT AC Only or Emergency Operation READ AND FOLLOW ALL SAFETY INSTRUCTIONS

QD-ENG-68 Controller for Thermoelectric Thermal Management

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

PSC-ID-x-CM Series Ceiling Mount Occupancy Sensor

MANUAL RESET ALARM RELEASE BOX

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

International ECO Door Controller Installation Guide

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

"Pegaso" wireless alarm system

HR-Robus. Included INSTALLATION INSTRUCTIONS. Industrial Door Microwave Motion Sensor

Installation Guide & User Manual

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

300 SERIES MINI MAGNETIC LOCK 1000 SERIES INDUSTRIAL MAGNETIC LOCK 1100 SERIES ARCHITECTURAL MAGNETIC LOCK 1100 SERIES MORTISE MAGLOCK & DOOR PULL

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

ACM8 Series UL Listed Sub-Assembly Access Power Controllers. Installation Guide. ACM8 - Eight (8) Fuse Protected Outputs

S INTRUSION&FIRE ALARM AND ACCESS CONTROL PANEL

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

Installation Guide for models:

Transcription:

Door Activation Devices CM-RQE70A PIR REQUEST TO EXIT DETECTOR THIS PACKAGE INCLUDES (2) #6 x 3/4" Screws (2) 3/16" Wall Plugs (2) MOV's BP7175 1. GENERAL DESCRIPTION Camden CM-RQE70A Request-to-Exit Sensor is a passive infrared (PIR) detector designed for interior use. This device is UL listed as an access control device under UL 294 Standard and is listed for Class I for UL Canada under ULC-S319 when it is connected to a UL approved access control system. 2. FEATURES Compact size, designed to mount on door frames On-board programming buttons. No dip switches (4) factory default operating modes, with the ability to customize mode attributes Makes installation easy and fast Selectable Fail Safe/Fail Secure (2) Form C contacts Momentary and latching relay modes Secondary activation device input Self-Test FIGURE 1 - MOUNTING LOCATIONS When power is first applied to the CM-RQE70A, the sensor will beep once, then the unit performs a self-test to ensure its major functions are within acceptable operating parameters. The self-test checks the input voltage, switch operation and sensor function. If the sensor passes all tests, there is a single beep and normal operation begins. If the sensor fails any of the tests, the unit will provide a series of audible beeps indicating the failure. This is take approximately 30 seconds. Post-Test Failure Beeps If the sensor fails a test, the unit will perform one or more short beeps, followed by a long beep. This series of beeps is repeated continuously. Card/keypad input Door position switch input Request to exit input Built-in sounder (adjustable) Tamper switch 3. OPERATION OUTPUT RELAY SOUNDER MODE PARAMETER ADJUST TAMPER SWITCH FIGURE 1 - COMPONENT LOCATIONS LED LENS LOCK DOWN SCREW # of Short Beeps 1 The IR sensor did not settle to an acceptable level during the test. 2 One of the 3 buttons, Mode, Parameter or Select is detected as being pressed. 3 The Source Voltage to the CM-RQE70A is outside of the range of 12 24V 4 The IR sensor is not changing over a large enough range of values to reach its settle point Fail Safe vs Fail Secure: Field Selectable These terms are used to describe the normal operating state of the output relays. In Fail Safe Mode, the relays will be normally energized. The relays will de-energize when a person is in the field of view (normal operation) or when the power is removed due to an outage or other external reasons. In Fail Secure Mode, the relays remain de-energized normally. The relays will energize when a person is in the field of view (normal operation). The relays remain de-energized during a power outage, therefore, keeping the controlled device secure. Page 1 of 6

Tamper Switch Dry contact outputs N/C are provided for interface to an alarm or access control systems. The Tamper Switch is connected to a spring that compresses and closes the switch when the housing cover is installed. Removing the cover will open the switch contacts providing a change in state to the monitoring system. Indicator Lights: LED s A Red & Green LED indicates secure vs unsecured status of the REX. The red LED is normally lit to indicate the door is secure. When a person walks within the detectable range of the sensor, the green LED will light and the red will be off. Access Control : Dry N/O A dry contact closure on this input allows a card reader or keypad on the secure side of the door to activate the REX sensor allowing access through the secured door. Control : Dry N/O A dry contact closure from an external device will hold this sounder on until it is released. The sounder will not affect the operation of the relays or relay timers. Sequential Logic : Dry This mode allows a secondary detection device to be connected to the REX sensor. The REX sensor is active only while this input is opened or for 10 seconds after it has closed. For example, when the secondary activation device is activated, the REX sensor functions normally. When a person is in the field of view, the sensor is activated and the door is released. If the secondary activation device is deactivated, the REX Sensor will continue to be activated if a person is in the field of view for an additional 10 seconds. Door Monitor Contacts : Dry Operating Functions Function 1: Latched When the REX sensor is activated, the relay will remain active as long as the sensor is activated. Once the sensor is deactivated, the relay will remain on for the duration of the Relay On Time. If the door is opened, the Relay On Time is reduced to 2 seconds. Function 2: Door Prop Open Alarm The door contact input is used to monitor the status of the door. If the door is held open during the last 10 seconds of the timer relay set time, the sounder will annunciate until the door is closed again. If the door is opened without the REX being activated the sounder will annunciate until the door is closed or someone has moved into the REX Sensor s field of view. Function 3: Unauthorized Access Mode In this mode, when the REX sensor is activated but the door is not opened, the relay returns to a secured state in 10 seconds. If the REX sensor is activated and the door opens, then closes, the relay returns to secured state in 2 seconds. Function 4: Timed When the REX sensor is activated, the relay will remain active for the duration of the Relay On Time. Once the Relay On Time has expired, the relay drops out. If motion continues, the relay will activate for another full cycle. If the door is opened, the Relay On Time is reduced to 2 seconds. /Enable : Dry In this mode, the REX is enabled or disabled by an external device, such as an access control system or security alarm panel. While this input is held open, the REX sensor will function normally. When this input is closed, the REX sensor operates the same as in Sequential Logic Mode. Rex Sensor Default Modes In an effort to make installation easier, we have defined different installation modes. These modes will cover 90+% of the applications. For the other 10%, there will be a Custom Mode where all settable functions can be adjusted. Mode 1: Normal Latched REX Sensor The most common mode, the sensor, when activated will enable the output relay for the duration of the Relay On Time (30 seconds). If a door contact is connected to #1, when the door is sensed to be opened, then closed, the Relay On Time is reduced to 2 seconds. Relay On Time: 30s (If the door is opened and closed, the timer is reduced to 2s) Fail Mode: Fail Safe Operating Function: Latched Mode 2: Door Prop Alarm The sensor monitors the status of the door. When activated, the sensor enables the output relay for 30 seconds. If the door is held open during the last 10 seconds of the Relay On Time, the piezo will sound until the door is closed. This mode requires a to be connected to #1. Relay On Time: 30s (If the door is opened and closed, the timer is reduced to 2s) If the door is held open during the last 10 seconds of the relay on time, the piezo will sound until the door is closed. Fail Mode: Fail Safe Operating Function: Door Prop Open Alarm Mode 3: Access Control The sensor will activate normally on motion. #3 is used to connect to an access control system. A contact closure on #3 will activate the sensor. A maintained closure on #3 will activate the sensor indefinitely. Relay On Time: 0.5 sec (If the door is opened and closed, the timer is reduced to 2s) Fail Mode: Fail Safe Operating Function: Timed Card Page 2 of 6

Mode 4: Secondary Activation Mode The sensor requires activation of #3 before activating the output relay. Relay On Time: 30s (If the door is opened and closed, the timer is reduced to 2s) Operating Function: Latched, Door Prop Open Alarm or Unauthorized I Sequential In this mode, the sensor would behave as described above. Mode 5: Custom Settings The sensor may be programmed as required by the installation. Relay On Time: 0.5, 1, 2.5, 5, 15, 30 45, and 60 seconds (unauthorized mode is 10 sec) Fail Mode: Fail Safe or Fail Secure Operating Function: Latched, Door Prop Open, Unauthorized or Timed PIR Sensitivity: 1 to 5 Sound Vol: 0 to 4 Unused,,, Sequential,,, Card Unused,,, Sequential,,, Card Unused,,, Sequential,,, Card 4. INSTALLATION Remove the sensor cover Install the Back Plate 1. Insert a small flat screwdriver into the bottom end of the housing cover and gently pry the cover from the main assembly. 2. Loosen the sensor vertical adjustment screw. 3. Rotate the sensor PCB assembly until it is removed from the back plate. 1. Using a 3/16 drill, drill 2 mounting holes 3 ¼ apart at the desired height of installation. 2. Insert the 2 x 3/16 wall plugs into the holes 3. Align the sensor back plate with the mounting holes and screw in the 2 x #6 screws, securely fastening the sensor back plate to the wall. 4. Rotate the sensor PCB assembly into the back plate. Wiring the Sensor The Camden CM-RQE70A uses a plug-in wiring harness for all electrical connections. The Pin out is described below. 1 Power + 2 1 3 2 4 3 5 Ground 6 Tamper Switch 1 7 Tamper Switch 2 1 Relay 1b Normally Closed (NC2) 2 Relay 1b Normally Open (NO2) 3 Relay 1b Common (C2) 4 Relay 1a Normally Closed (NC1) 5 Relay 1a Normally Open (NCO1) 6 Relay 1a Common (C1) 7 Power - Adjusting the Sensor Detectable Range EMF spike protected relay The sensor s detectable range can be adjusted vertically and horizontally. Horizontal Adjustment The horizontal adjustment of the sensor is accomplished by adjusting the 2 louvers inside the lens area. The louvers are adjusted using a small flat head screwdriver. On the bottom of the sensor housing there are 2 adjustment screws. Turning the screws adjusts the louvers left and right horizontally, therefore changing the beam direction and width. Once the horizontal adjustment is complete, place the tamper label (provided) over the set screws to avoid accidental adjustment. Vertical Adjustment The sensor beam is vertically adjusted by rotating the PCB assembly barrel within the mounting back plate. Once the vertical adjustment is complete, tighten the lock down screw to prevent the barrel from moving. Once all adjustments are made, install the sensor cover and install the set screw provided. Page 3 of 6

Programming Buttons There are no DIP switches to set on this Rex Sensor. 3 buttons are used for all setup and programming. The MODE Button (top): OUTPUT RELAY SOUNDER MODE PARAMETER ADJUST TAMPER SWITCH The MODE button is used to select 1 of 4 pre-set modes or a fully configurable custom Mode. Pressing the MODE button for the first time will indicate which Mode the REX sensor is currently in. The REX sensor will BEEP and the LED will flash red the number of times equal to the MODE number. I.E. 1 Beep/Flash = Mode 1. The Parameters Button (Middle) This button selects the available parameters in each mode that can be customized. From within any Mode, press this button to cycle through the parameters. LED LENS LOCK DOWN SCREW Mode Beeps Red LED Flashes The Adjust Button (Bottom) 1 1 1 Latched Mode 2 2 2 Door Prop Alarm Mode 3 3 3 Access Control Mode 4 4 4 Secondary Activation Mode 5 5 5 Custom Settings Mode The adjust button is used to change the value of the Parameter. Once a Parameter is selected, use the Adjust button to cycle through the available options for each parameter as described in the below table. Parameter 1 beep 2 beeps 3 beeps 4 beeps 5 beeps 6 beeps 7 beeps 8 beeps LED Relay On Time 0.5 1 2.5 5 15 30 45 60 Yellow Solid Fail Mode Safe Secure Red/Yellow Operation Mode Latched Door Prop Open Alarm Unauthorized Access Timed Green/Yellow PIR Sensitivity 1 2 3 4 5 Red/Green Sound Volume 0 1 3 3 4 Red/Green/ Yellow #1 Unused Card/ Door Contact Sequential Red #2 Unused Card/ Door Contact Sequential Green #3 Unused Card/ Door Contact Sequential Yellow Factory Reset The Camden CM-RQE70A Request to Exit sensor can be reset to factory defaults by pressing and holding the MODE and Adjust buttons. The Sensor will start to beep. Continue holding the MODE and ADJUST buttons while the beeping gets progressively faster until it reaches a steady tone. When the tone stops, the REX sensor has been reset to factory defaults and the MODE and ADJUST buttons may be released. Regulatory Information The unit shall be installed in accordance with National Electrical Code ANSI/NFPA 70 and part 1 of the Canadian Electrical Code CSA C22.1, Safety Standard for Electrical Installations and authorities having jurisdiction (AHJ s). Page 4 of 6

MOV Maglock MOV Maglock - 12-24 V DC Power + Vin- C1 NO1 NC1 C2 NO2 NC2 Notes: 1. Relay is set to Safe Mode in this application 2. Relay O/P2 is EMF protected. If using O/P1a diode should be place across the maglock power connections. - 12-24 V DC Power + Notes: 1. Relay is set to Safe Mode in this application 2. Relay O/P2 is EMF protected. If using O/P1a diode should be place across the maglock power connections. Vin+ I1 I2 I3 GND T1 T2 Vin- C1 NO1 NC1 C2 NO2 NC2 Vin+ I1 I2 I3 GND T1 T2 Request to Exit Push Button Control Request to Exit Push Button 1 2 3 4 5 6 7 8 9 Access Control / Reader MODE 1&2 WIRING DIAGRAM MODE 3 WIRING DIAGRAM - 12-24 V DC Power + MOV Vin- C1 NO1 NC1 C2 NO2 NC2 Vin+ I1 I2 I3 GND T1 T2 Request to Exit Push Button REX Sensor Eye Beams Maglock Notes: 1. Relay is set to Safe Mode in this application 2. Relay O/P2 is EMF protected. If using O/P1a diode should be place across the maglock power connections. 1 2 3 4 5 6 7 1 2 3 4 5 6 7 Power + 1 2 3 Ground Tamper Switch 1 Tamper Switch 2 Relay 1b - Normally Closed (NC2) Relay 1b - Normally Open (NO2) Relay 1b - Common (C2) Relay 1a - Normally Closed (NC1) Relay 1a - Normally Open (NO1) Relay 1a - Common (C1) Power - EMF Spike protected relay MODE 4 WIRING DIAGRAM 5. SPECIFICATIONS Voltage: Current Draw: Relays: Contact Rating: Programming: Modes: Coverage: 12 /24V DC operation 50mA (max) (2) Form C (DPDT) 3A @ 30VDC On-board push buttons and status LED - (4) Factory Default - (1) Fully Custom - Selectable Fail Safe/ Fail Secure - Max. 10 W x 10 H - Horizontal & vertical adjustment (mechanical) - Sensor sensitivity/range (electronic) Time Delay: Adjustable, 0.5, 1, 2.5, 5, 15, 30, 45 & 60 second : On/Off, with adjustable volume Piezo Buzzer: 92db.@ 10cm. Indicator: Activation LED Card or : (1) N/O Door Position Switch : (1) N/O Request to Exit : (1) N/O Tamper Switch Contact Rating: 50mA @ 12VDC Temp Operating Range: 32 F - 120 F (0-50 C) Humidity Range: 0-93% non-condensing Dimensions: 1 3/4 H x 7 W x 1 3/4 D (43mm x 176mm x 43mm) Weight: 0.25 lbs. (0.12kg.) Colors: White and black models UL 294 Access Control Performance Levels 1) Access Controls, Destructive Attack Level I (No Attack) 2) Line Security - Level I (No Line Security) 3) Endurance - Level IV (100,000 cycles) 4) Standby Power - Level I (No Stand by Power) Power is to be supplied by a compatible UL294 Listed control unit, or by a UL294 Listed or UL603 Listed Class 2 low-voltage power limited power supply that is capable of 4 hours of standby power, as described in the installation guide. The products shall not be installed in the fail-secure mode unless permitted by the local authority having jurisdiction and shall not interfere with the operation of Listed panic hardware. Page 5 of 6

6. COVERAGE INFORMATION The detection area changes depending on the mounting height and angle of the lens of the REX sensor. If the REX sensor is mounted on the wall above a door with the lens pointing straight, the detection areas against the wall are not detected and not shown in the illustrations. Mounting the REX sensor at higher heights,results. in a larger detection area typically. The illustrations show the REX sensor mounted at 7.5 (2.3m) Feet on a wall with the lens pointing straight down and at 8 Feet (2.4m) on a ceiling with the lens pointing straight down. 7 5 Ceiling - Above Single Door 8 Ceiling - Over the Ceiling Front View Front View Bird s-eye View Bird s-eye View 11 6 (3.5m) 12 (3.6m) Side View Side View 2 ft. (0.6m) 3 ft. (0.9m) Opening New Doors to Innovation, Quality and Support! Call: 1.877.226.3369 / 905.366.3377 Visit: www.camdencontrols.com File: CM-RQE70A Detector Manual.indd-R1 Rev. Label/Date: 1/07-26-17 Part No: 40-82B203-A Page 6 of 6