Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Similar documents
Use of the application program

UP 258E11 OPTISENS OFFICE

DOCUMENTATION IPS640

DOCUMENTATION IPS640

Connections, displays and operating elements C D E G H. Installing the control unit

Product and functional description

Product and Applications Description

Product and Applications Description

Product DELTA i-system DELTA profil titanium white 5WG HB11 pearl grey 5WG AB01 Motion detector

Motion detector UP 255, UP 256, UP 257, UP 258 5WG AB 5WG AB 5WG HB

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

Devices for Special Applications

Operating instructions

SHUTTLE BELL-PRESS DIMMER DATA SHEET

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Use of the application program. Functional description. instabus EIB Application program description. October CO Touch-Manager wave

RVL479. Heating Controller. for use with a partner unit

0701 CO Light, HVAC, Monitoring, Brightness

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

PRELIMINARY EDITION

Room Temperature Controller

OPERATING INSTRUCTIONS

Room Temperature Controllers

RVL480. Heating Controller

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

Room thermostat with 24-hour time switch and large LCD

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

B.E.G. LUXOMAT KNX-OCCUPANCY DETECTOR

RVL481. Heating Controller. including d.h.w. heating

PresenceLight 180A-KNX.. PresenceLight 360A-KNX.. PresenceLight 180B-KNX.. PresenceLight 360B-KNX..

Trailing Edge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Description of the application programme for KNX occupancy detectors version 3.1

TrailingE dge Dimmer. 32E450T Series. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Universal pushbutton dimmer etd U2 etd 2e

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

Electronic timeswitch

Semi flush-mount communicating room thermostats

Universal Dimmer. 31E2RUD Series ROTARY CONTROL. Installation Instructions. Integrally Switched Rotary Controlled INTEGRALLY SWITCHED 240V

Device Technology. Supply Operating voltage Implemented via the bus KNX: V DC XIB: 12 V DC (rated voltage) Voltage range: 10.

Room thermostats with LCD RDD100..

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

Zone Terminal, 2-fold, FM MT/U , GH Q R0111

SMART BASIC BASIC-IR DAYLIGHT

1592P01. for liquids in piping DN

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

2. Safety. 4. Function

Motion detector themova P360 KNX UP WH themova P360 KNX UP GR

Operating Manual MS220KA and MSR220KA

18/2 General. 18/4 Dimensional Drawings N. 18/7 Switches and Pushbuttons. 18/14 Socket Outlets. 18/16 Dimmers. 18/31 Motion Detectors

Product Bulletin for Decora Rocker Slide Controls

DALI Product Range. Designed in Australia to be compatible for all DALI systems. gerardlighting.com.au

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Local Control Network - building controls in perfection

Room thermostat with Auto Timer, Option External Input

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

Wireless room thermostat with LCD

TROPO 15W Dimmable LED Driver

TSXAEY1614C analog input module - 16 inputs - thermocouple - 16 bits

Room air quality sensors

Installer Manual KNX Touchscreen Thermostat

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

Sensors SR Programming manual

Monitoring Devices 11/1

Controlling LEDs to meet. Russ MacAdam Director of Engineering Development

DALI MSensor 02 Multi-sensor for DALI system

RVL470. Heating Controller. Use. Functions. Series B

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

Info-Display xx

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

Fume Hood Operating Display Panel

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

KNX/EIB - Product database - Application description

Room thermostat with Auto Timer, Option External Input

Panel Mounted Fault Annunciator Series

Technical Manual MDT Motion Detector

Install intelligent room automation flexibly and future-proofed

QFM21... Duct sensors. Symaro. for relative humidity and temperature

No. Icon Name Function

Application Sheet Chilled/heated ceiling (4 pipe) with 6-way valve on analog output

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Duct Temperature Sensors

C-Bus Four Channel Analogue Output Unit Installation Instructions

Room Air Quality Sensors

Flush-mount room sensor KNX S-Mode / KNX LTE- Mode / KNX PL-Link

Room thermostat with independent DHW control

Skydance offers a complete AC Triac control system that contains Triac dimmer/ switch, Traic dimmable LED driver, and DMX512 Triac Converter.

Vibracon LVL-A* Level limit switch for liquids, compact design

Mimic display driver, LED ribbon cable

64.7 Ø85. (1) Sensor inset (2) Lens pluggable. (3) Protection cover (covers the high-voltage terminals). (4) Ceiling (drill hole Ø70mm).

ST3124. KNX Blind Actuator DC 4-fold. Operation and Installation Manual

Oil Burner Controls LMO24... LMO44...

Rev KNX Technical Reference Manual Busch Präsenz tech 6131/ /11-500

RVP310. Heating Controller. Building Technologies HVAC Products

QPA63... CO 2 /VOC Sensors. Siemens Building Technologies HVAC Products

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

Application Sheet Fan coil unit with staged fan, 6-way heating/cooling coil (4 pipe) on analog output

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

Transcription:

Gamma instabus Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG1 528-1DB01 Technical Product Information Universal Dimmer for switching or dimming of dimmable lamps Supports dimmable lamps including LED Output load up to 2 x 300 VA individually or 1 x 500 VA No minimum load required Operation mode leading or trailing edge Automatic load detection Protected for short circuit, over load and temperature with LED indication Functions with commissioning with ETS Operating hours counter with threshold overrun warning Switching cycle counter with threshold overrun warning Integrated 8-bit scene control and assign of each output to up to 8 scenes

Use The universal dimmer is a 4 MU-wide device for DIN-rail mounting with N-system dimensions. It is designed for lighting control, i.e. for switching and dimming resistive, inductive or capacitive loads ranging up to 300 VA with 230V AC, 50/60 Hz per output. The bus is connected via a bus terminal block. The device electronics are supplied via the bus voltage. Application The device can be connected with loads on two outputs or for a higher load only with one output. A minimum load is not required. Fig. 1 shows a 2-channel application with two independent controlled outputs. Optional a 1-channel application uses only one output A or B with higher load. Note: Neutral (N) is not connected internally. External connection is needed for each channel. L1 L1 A B A B A B Fig. 1 Schematic applications Types summary Type Article number Description Applications KNX PL-Link N 528D01 5WG1 528-1DB01 Universal Dimmer Switching Dimming Scene control Yes 2 / 13

Technical design Operating elements A1, A2 Terminals channel A, B B1, B2 Status LED channel A, B C LED for indicating normal operating mode (LED off) or addressing mode (LED on); returns to normal operating mode automatically after receiving the physical address D Learning button for switching between normal operating mode and addressing mode and for receiving the physical address E Label for physical address F Bus terminal block Fig. 2 Location of operating elements Protection against short-circuit In a short-circuit condition the dimmer turns the load off for 3 seconds and automatically tries to switch the output on to the currently set dimming value. If the short-circuit condition still persists the output is turned off permanently. Turn the output on again by receiving a telegram on or dimming value >0. Protection against over temperature / overload In case the maximum permissible temperature is exceeded, which also can indicate an overload, the dimmer turns off immediately. If after 1 minute the dimmer has cooled down sufficiently, it automatically dims back to the currently set dimming value, if there was received a telegram turn on or a dimming value > 0. Immunity to ripple control signals and electrical grid frequency fluctuations In the ex-factory settings the influence of ripple control signals is compensated to reduce flickering of the lamp. This measure increases the influence of electrical grid frequency fluctuations on the brightness of the lamp. A mostly undisturbed operation for an electrical system without a synchronous connection to the electrical grid can be achieved when the ripple control compensation is disabled via the associated parameter. The dimmer becomes less sensible to frequency fluctuations in the electrical system. Yet, ripple control signals will lead to an increased flickering of the load. Building Technologies Divison 6300 Zug Subject to change December 2018 3 / 13

Functions with commissioning with ETS The device is configured and commissioned with Engineering Tool Software (ETS) version ETS4 or higher. With the ETS (Engineering Tool Software) the specific parameters and addresses are assigned appropriately, and downloaded into the device. The actuator output may be set to one of the following operating modes: - Normal mode - 1-level time switch mode - 2-level time switch mode - Flashing Dependent on the selected operating mode, objects for the functions switching, dimming brighter / darker and dimming value are available for the actuator output. Furthermore, if required, time-limited switching instead of permanent switching on can be enabled for each channel via an optional "Night mode" object (e.g. for lighting while cleaning), if needed with a warning before switching off by multiple switching the output off and on (flashing). Dependent on the configuration, additional objects are available for the output channel for the functions locking and status request. The following schema shows the named features in a logical overview. Fig. 3 Schematic design of a dimming actuator channel The application program includes optional a switching cycle and operating hours count with threshold monitoring for each output and an integrated 8-bit scene control, in which each output can be incorporated into up to 8 scenes. Behavior on bus voltage failure / recovery On bus voltage failure the current switching status and dimming values are saved for restoration on bus voltage recovery. On bus voltage recovery the configured actions are executed and, if applicable, new status values are reported. 4 / 13

Building site function The building site function provided ex-factory enables switching the building site lighting on and off via bus wall switches and actuators, even if these devices have not yet been commissioned with ETS. Behaviour on unloading the application program When the application program is unloaded with ETS the device does not function. Resetting the device to factory default settings A very long push of the programming button (> 20 s) effects a reset to factory settings. This is indicated by constant flashing for 8 seconds. All configuration settings are lost. The building site function is re-activated. Functions with commissioning with Desigo Room Automation Additional information like Desigo system description, product catalog for Room automation etc. is available here: www.siemens.com/bt/en/desigo-tra Product documentation Additional information like operating and mounting instruction, application program description, Product database, additional software, product image, CE declaration etc. is available here: http://www.siemens.com/gamma-td Building Technologies Divison 6300 Zug Subject to change December 2018 5 / 13

Notes Security DANGER The device must be mounted and commissioned by an authorized electrician. A safety disconnection of the device must be possible. The device must not be opened. Use only loads that allow dimming operations. Conventional transformers may be used. If they comply with the relevant standards and contain a thermal fuse. For planning and construction of electric installations, the relevant guidelines, regulations and standards of the respective country are to be considered. Connecting inductive loads together with capacitive or resistive loads to the same dimmer output is not permitted and leads to damage or destruction of the universal dimmer! Dimming of inductive loads with trailing edge mode could damage the device. Notes Indication LED The channel A/B LED indicates the status and error messages. Indicator Off Red, on Green, on Orange, 0.2 Hz Orange, 0.5 Hz Orange, 1 Hz Orange, 5 Hz Description Device is not powered by KNX. Channel output is turned on. Channel output is turned off. Channel failure / power failure Overtemperature: temperature too high Over load: load too high Short circuit: current too high Note: In case of exceeded temperature, overload, or short circuit, the dimmer turns off the output. Restart the dimmer by using an on or dimming value > 0 command. In case of overtemperature, wait at least 1 minute and then restart the dimmer (cooling down time). Note: Trailing edge mode occurs sometimes with a limited dimming range and an irregular dimming curve, but with less power-loss. Manual adjustment of control mode (trailing /leading edge) or min./max. dimming value is possible by Software. 6 / 13

Commissioning of dimmable LED and CFL Not all LED and CFL are dimmable, because they have electronic components included. Only dimmable lamps can be dimmed properly. Lamp manufactures note this feature on lamps, on packages or in the datasheets. The maximum load also depends on operating mode, current peak. Dimmable LED CFL LED retrofit LED driver Fig. 4 Dimmable LED and CFL Operation mode for load control LED driver can control LED via constant current or voltage and are similar to Low voltage halogen lamps with electronic transformers LED Retrofit lamps have a built-in LED driver, replace mostly incandescent lamps and fit into standard sockets (E27, E14, ). Always prefer the recommended operation mode of the lamp manufacturer. Universal dimmers support two kinds of operation modes: Leading Edge: Mostly used to get a proper dimming behavior and the lamp can be dimmed very smooth. Trailing Edge: Mostly used to control more or higher load at the output, because there is less powerloss. Note: Dimming of inductive loads with trailing edge mode is not permitted. Automatic load detection The universal dimmer sets LED mostly in Trailing edge mode. Via parameter settings the mode can be changed in two options: optimized dimming behavior less power-loss to control higher loads. Building Technologies Divison 6300 Zug Subject to change December 2018 7 / 13

Dimming behavior With the parameter settings the dimming behavior of LED can be optimized to behavior of incandescent lamps. With Minimum dimming value and Maximum dimming value the range of viewable brightness changes of the LED can be adjusted. Some LED work properly only, if the maximum dimming value is set to less 100%. With Start on value some LED can be only turned on with a higher brightness value, so the LED driver gets enough power to turn on the light. Then the brightness can be dimmed down to a lower level. 8 / 13

Mounting The device is intended to be used for permanent interior installations in dry locations within distribution boards or small casings with DIN rail EN 60715-TH35-7.5. Mounting and connection Dismounting Step 1 Step 2 Step 3 Fig. 5 Mounting and connection Fig. 6 Dismounting Commissioning The learning button is used to switch between different operational modes. Press and hold <2 s: Enable addressing mode. The programming LED is on. After receiving a physical address, the dimmer returns to normal mode. Return to normal mode from other modes. (Programming LED is off). Press and hold >5 s and <20 s: Enable connection test for commissioning with Desigo. Press and hold >20 s: Reset the dimmer to factory settings. Programming LED flashes 8 s. Note: All configurations are lost. The building site function is re-activated. Building Technologies Divison 6300 Zug Subject to change December 2018 9 / 13

Technical data Power supply KNX bus voltage DC 24V (DC 21...30V) KNX bus current Typical 5 ma, max. 8 ma. Rated voltage Rated current 230V AC +10%/-15%, 50/60 Hz 2-channel: 2 x 1.3 A @ cosф=1.0 1-channel: 1 x 2.2 A @ cosф=1.0 Load output (at 35 C operating temperature; derating to 80% at 45 C) Typical lamp types Use of 2 channels 1 channel Incandescent lamps 300 W 500 W High voltage halogen lamps 300 W 500 W Low voltage halogen lamps with electronic 300 VA 500 VA transformers Low voltage halogen lamps with magnetic 240 VA 400 VA transformers Dimmable energy-saving lamps (CFL) 45 VA* ) 75 VA* ) Dimmable LED 100 VA* ) 200 VA* ) * ) The max. total power depends on the lamp type and control mode (leading/ trailing edge). The following figure shows the maximum load output of the dimmer at different operating temperatures. Max. load output [%] Operating temperature [ C] Fig. 7 max. load output derating diagram Connections KNX bus line Load connections Bus terminal block, screwless, conductor cross-section 0.6 0.8 mm Ø single core, insulation strip length 5 mm Screw-type terminals, insulation strip length 7... 9 mm The following conductor cross-sections are permitted: 0.5... 4.0 mm² single core, 0.5... 2.5 mm² finely stranded 10 / 13

Technical data Physical Specifications Housing Dimensions Mounting Weight Fire load Power loss if output is off plastic 72 x 90 x 55 mm DIN-rail EN 60715-TH35-7,5 approx. 220 g approx. 2 MJ 0.9 W / channel Environmental conditions Ambient temperature in operation -5 C +45 C Storage temperature -20 C +70 C Relative humidity (non-condensing) 5 % to 95 % Climatic withstand capability EN50491-2 Reliability Failure rate: 1501 fit at 40 C Standards Degree of pollution 2 (according to IEC 60664-1) Overvoltage category III (according to IEC 60664-1) Protection class ( according to EN 60529) IP20 Reliability Failure rate: 1501 fit at 40 C 11 / 13 Building Technologies Divison 6300 Zug Subject to change December 2018

Standards Electrical Safety Bus Devices covers Electromagnetic compatibility Markings CE mark Safety extra low voltage SELV DC 24 V EN 50428 EN 50428 KNX EIB Complies with the EMC regulations (residential and functional buildings), low voltage regulations and RoHS Directive 12 / 13

Dimensions Fig. 8 Dimensions Support The operating instructions must be handed over to the client. A faulty device shall be returned with a Return Good Note for Service provided by the appropriate Siemens sales office. If you have further questions concerning the product, please contact our technical support. +49 (911) 895-7222 7 +49 (911) 895-7223 * support.automation@siemens.com www.siemens.de/automation/support-request 13 / 13 Siemens Switzerland Ltd DS02 Update: http://www.siemens.de/gamma-td Building Technologies Divison CH-6300 Zug Änderungen vorbehalten December 2018