inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Similar documents
Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

THE CONTROL METHOD OF THE INFLOW TURBU- LENCE INTERACTION NOISE FOR ROUTER COOLING FAN

A Novel Approach for the Thermal Management. of PC Power Supply

EXPERIMENTAL ACOUSTIC CHARACTERIZATION OF A WET VACUUM CLEANER

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

ICSV14. Cairns Australia 9-12 July, Noise reduction of handheld vacuum cleaners according to geometric optimization of air passages

Effects of Volute Tongue Clearance and Rotational Speed on Performance of Centrifugal Blower Nitin S. Jadhav *, S. R. Patil

Experimental study of the influence of geometrical parameters on the cavitation of a small centrifugal pump

Design And Analysis Of Centrifugal Pump

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Development of Large Size Hybrid Fan

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Old style propeller New style propeller

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

The Role of Computational Fluid Dynamic and Aeroacoustic Simulations in Reducing the Noise of a Forward-Curved Blade Radial Fan

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

SSRG International Journal of Thermal Engineering (SSRG-IJTE) volume 1 Issue1 Jan to April 2015

Compression of Fins pipe and simple Heat pipe Using CFD

The Advantages of Choosing Centrifugal Fans

FLOW AND PERFORMANCE INVESTIGATIONS OF CENTRIFUGAL BLOWERS WITH AEROFOIL BLADED IMPELLERS

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

What is the correct type of fan: Axial, radial, diagonal?

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

EXPERIMENTAL ANALYSIS OF TIP CLEARANCE AND CHORD LENGTH FOR OPTIMUM DESIGN OF AXIAL FLOW FAN IN AIR COOLED HEAT EXCHANGER

Study of Hot-air Recirculation around Off-road Tier-4 Diesel Engine Unit Using CFD Abbreviations Keywords Abstract Introduction and Background

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

Introduction to Fans. The Basics of Fan Principles and Terminology

AcoustiFlo Fans: Retrofit Solutions and Beyond

Thermal Analysis of Concentric Tube Heat Exchanger Using Louvered Strip Inserts

Influence of the magnitude of the angle of attack on the voltage produced by a miniature wind turbine

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

Available online at ScienceDirect. Energy Procedia 91 (2016 ) 35 41

STANDARD, QUIET AND SUPER QUIET THE MODELLING OF FLOW AND THE REDUCTION OF TURBULENCES

Optimized fan system design for the one-year cycle of a Heat Pump. Ziehl-Abegg SE Frieder Lörcher

EC Plug Fans EC FanGrid Retrofits for High Efficiency Air Handling Units

Low-noise fans are not a product of chance

Finned Heat Sinks for Cooling Outdoor Electronics under Natural Convection

High-efficiency Turbo Chiller (NART Series)

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS

Prediction of Psychoacoustic Parameters

TITLE: Improvement in Heat Transfer Rate and Dynamics of Shrouded Fanned Radiator System

Heat pump supplemental heating system for motor vehicles

FREQUENCY ENHANCEMENT OF DUAL-JUNCTION THERMOCOUPLE PROBES

Fans: Features and Analysis

In-Situ Roll Balancing A Revolutionary Method for Improving Dryer Section Performance

Specific Energy Consumption comparative study of Hot Air dryer and Heat Pump dryer for highland drying process Sayompon Srina

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Effect of Flow Distortion in Inlet Duct on the Performance of Centrifugal Blower

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Optiline Fan Array. The optimum number of fans for every application. The Optimum in Sound Energy Size Redundancy Reliability.

Clemens Felsmann 1, Jean Lebrun 2, Vincent Lemort 2 and Aad Wijsman 3 ABSTRACT INTRODUCTION METHODOLOGY

Ducted Propeller. Airflow Volume

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

EXPERIMENTAL AND THEORTICAL STUDY OF THE THERMAL PERFORMANCE OF HEAT PIPE HEAT EXCHANGER

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe

Development of Motor Fan Noise Prediction Method in Consideration of Operating Temperature during Engine Idling

AN ANALYSIS OF THE ACTUAL THERMAL PLUMES OF KITCHEN APPLIANCES DURING COOKING MODE

CASE HISTORY: RETROFIT OF COAL MILL EXHAUST FAN STUDY OF FAN PERFORMANCE AND EROSION

Analysis of the influence of open door size on fire smoke diffusion law in protective engineering

FROM COMPONENTS TO SYSTEM APPROACH OPTIMIZATION OF AIR-WATER HEAT PUMPS

Agitation and Mixing

High-Performance, High-Reliability Gas Heat Pump

Performance Analysis Of Double Inclination Ribbed Solar Air Heater Rectangular Duct By Liquid Crystal Thermography

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

A study of Transient Performance of A Cascade Heat Pump System

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

DESIGN AND FABRICATION OF OMNI MULTI AXIS CEILING FAN

MINIATURE HEAT TRANSPORT SYSTEMS WITH LOOP HEAT PIPES

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations

DR AS 5389:2016 Space heating and cooling and ventilation systems Calculation of energy consumption. The physical testing

Development of a Compact High Efficiency Cooling Device for the PA8000 Processor*

Thermal Simulation of a Heat Pipe Tempered Injection-Mould Tool

Qualification of Fan-Generated Duct Rumble Noise Part 1: Test Facility

Andrzej Kesy Kazimierz Pulaski University of Technology and Humanities, Radom, Poland, and

Performance Analysis of Centrifugal Fan by CFD

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Fan Laws. Keith Miller. Samuel Tepp Associates. Paul Cenci, P. E.-Principal Brian England-Principal. Samuel Tepp Associates 1/6/10

A CEILING CONDENSING UNIT WITH PELTIER ELEMENTS FOR DRYING AND COOLING

Fan Performance and Selection. Overview

Water Pumps. turbo-hydraulic pumps, positive-displacement pumps.

AUDITORIUM OF THE MORGAN LIBRARY, COMPUTER AIDED DESIGN AND POST-CONSTRUCTION RESULTS

Experimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a)

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

FLIGHT UNLOADING IN ROTARY SUGAR DRYERS. P.F. BRITTON, P.A. SCHNEIDER and M.E. SHEEHAN. James Cook University

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Numerical Simulation of Fluid Flow and Heat Transfer in a Water Heater

MODELLING AND SIMULATION OF A ROOM WITH A RADIANT COOLING CEILING. Technicka 4, Prague 6, Czech Republic

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

Heat transfer enhancement in an air process heater using semi-circular hollow baffles

EXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Technical Selection. elevent ceiling diffusers. Swirl, Jet, Louvred and Curved ceiling diffusers

R718 TURBO CHILLERS AND VACUUM ICE GENERATION TWO APPLICATIONS OF A NEW GENERATION OF HIGH SPEED, HIGH CAPACITY R718 CENTRIFUGAL COMPRESSORS

Transcription:

1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 1.0 STUDY OF AEROACOUSTIC PHENOMENONS AT DUCTED COOLING FANS D. Lohmann DLR, Lilienthalplatz 7, 38108, Braunschweig, Germany Tel.: +49(531)295-2289 / Fax: +49(531)295-2914 / Email: dieter.lohmann@dlr.de Keywords: COOLING FAN, FAN AEROACOUSTICS, OPTIMIZATION, ROTOR ABSTRACT Germany s vehicle industry is greatly concerned with advancing their engines to make them environmentally compatible. This often leads to higher temperatures which have to be reduced by improved fans. However, less experience exists for high efficient fans of large diameters and power as used for trucks and busses. Therefore, two ducted full-scale fan models have been investigated to reduce noise and energy losses. Aerodynamic design parameters were planform, blade number, hub to tip ratio and the size of the slit. The experiments were conducted with a sucking wind tunnel and afterwards with the bus. The first model fan was designed such that the temperature is reduced by 3 degree and the noise by 1.3 db(a) when mounted inside the bus. However, more than 6 db(a) less noise was obtained with a second model due to an improved airfoil and a special localization inside the duct. The results indicate some important guidelines for the optimization of fans in the future. 1 - INTRODUCTION High technologies, developed at Aerospace Research Centers can also be used for other industrial branches as e. g. process engineering or automotive industry. Here, especially the transfer of numerical design tools for propellers, rotors or fans from aviation to ground-bounded vehicles or machines has been effective. During the last decade, several fan blade planforms were optimized to obtain quieter and more efficient cooling fans. At the early eighties the technology transfer started with a 6 db(a) noise reduction design for a customer of the German car industry [1]. Some further successful designs followed which all led to prototypes that are used in cars or fork lifts today. The computation of the complete cooling system is very complicated. Only isolated fans with an according disturbed onset flow are optimized at the state of art. The aerodynamics of such isolated ducted fans are computed with classical 2-D cascade flow methods [2], modern 3-D singularity or field methods [3]. For the computation of the periodic noise field a modified acoustic analogy method is applied whereas for the stochastic noise field a half-empirical method is developed which is based on turbulence models. All methods are validated with experiments before coupled with an optimization code. The goal of this work is a noise reduction of 4 db(a) and an increase of the flow rate of 15 %. Reference fan is an 8-bladed conventional fan. All possibilities to increase the performance were ladled out which led to the following design data: reference fan fan to be designed diameter [mm] hub/tip ratio blade number l [mm] M rot ϕ ψ 750 0.40 8 0.76 0.31 0.17 0.20 750 0.48 12 0.87 0.31 0.21 0.23 Table 1: Design parameter (M rot rotational Mach number).

2 In order to obtain a quiet fan it was decided to use laminar airfoils realized by a 4-digits NACA 65 thickness distribution on a circular meanline or by a numerical airfoil design. 2 - DESCRIPTION OF TESTS For a maximum power of 37 kw and the large fan diameter of 750 mm a sucking wind tunnel with a low speed chamber was built at the Fachhochschule Braunschweig-Wolfenbu ttel. All requirements of DIN 24 136/2 were met to obtain a smooth flow with no swirl (see Fig. 1). Figure 1: Test rig with wind tunnel and fan 1. The low speed chamber on the right side has a size of 2.7 3.3 2.9 m and consists of hard wooden surfaces. The cooler with the housing or the conical inlet is mounted at the right wall side where the fan sucks air form the tube. The static pressure of the fan performance was measured with Betz manometer inside the tube on the left side of Fig. 1, where the flow is controlled by plates. A second fan was installed to compensate the losses. The microphone is mounted 1.45 m above ground and in a distance of 800 mm from the fan center. The angle between the fan axis and the microphone radius is 45 degrees. Acoustic tests around the fan inlet inside the chamber have shown that the sound pressure level is approximately constant within 2 db. Only relative sound pressure level were considered, so that acoustic reflection effects could be ignored. The acoustic test results have been recorded as db(a)-weighted Overall Sound Pressure Level (OASPL) or narrow band spectra. As test conditions three operating speeds of 1700, 2400 and 2700 rpm s were selected. Furthermore, the slit size and the location of the fan inside the duct were varied (see Fig. 2). Figure 2: Geometric parameter definition. 3 - AERODYNAMIC DESIGN AND FIRST EXPERIMENTAL RESULTS Model 1 is a pure aerodynamic design and was computed by the Technical University of Braunschweig, Institute of Fluid Mechanics. The design method used combines the radial-equilibrium calculations

3 for the fan trailing edge plane with blade-to-blade calculations on non-axisymmetric, twisted stream surfaces [2]. The result of the computation is a 12-bladed fan which was built as a full-scale model 1 from aluminum and is shown in Fig. 3. (a): 8-bladed reference fan. (b): 12-bladed designed fan. Figure 3: Used full-scale fan models. The fan models were measured first as isolated fans. The maximum rpm was 2600. To obtain the performance at 2700 rpm, the flow rate and the static pressure were multiplied by a factor of 1.038 respectively its square, which is obtained from the ratio of the rpms (see Fig. 4a). (a): Static pressure. (b): Efficiency. Figure 4: Static pressure performance of the isolated reference fan and fan model 1. The size of the slit is 12 mm which is 3 mm smaller than inside the bus. At 2700 rpm the reference fan produces a flow rate of 8 m3 /s at the design point, whereas model 1 generates a flow rate of 10 m3 /s there. This is a flow rate increase of 25 %. At the same point the efficiency of model 1 is about 5 % higher than that of the reference fan (see Fig. 4b). The effect still increases with decreasing rpm. But, the efficiency, approximately ηstat = ψts ψtt ϕ2 =1 2 ψtt 4ξ ψtt with ξ = r/rtip, t for total and s for static is reduced due to the large flow and pressure coefficient. This limits the possibilities here to increase the efficiency by more than 5 %. Fan and cooler can be considered as a module. Because the losses of the cooler have to be added to the losses of the fan, the efficiency is about the half of the efficiency of the isolated fan. This explains why the efficiency and the flow rate in Fig. 5 are smaller than in Fig. 4. Around the design point the experimental values of module 1 are larger than those of the reference module. A further remarkable increase of the performance data could be obtained by reducing the slit from 12 to 7 mm. However, the flow rate increase due to the better design becomes smaller when the cooling modules instead of the isolated fans were compared. Instead of 25 % here only the half respectively 12,5 % were obtained. 4 db(a) noise reduction were obtained when the fan model 1 was measured. Also the acoustic results got worse with the cooler. Only 2 db(a) instead of 4 db(a) noise reduction were observed. Measurements inside the bus have shown that the temperature could be reduced by 3 K due to the increased airflow of fan model 1. However, the noise reduction was only 1.3 db(a).

4 (a): Static pressure. (b): Efficiency. Figure 5: Performance of the reference fan and fan model 1 with cooler at different slit sizes. 4 - ACOUSTIC DESIGN AND COMPARISON OF EXPERIMENTAL RESULTS To reduce the noise by further 2 db(a) another laminar airfoil was selected. This airfoil was numerically designed especially for fans and has less camber than the NACA 65 airfoil [1]. The difference in camber was added to the twist to obtain the same performance. Then the Lifting Surface Code LBS was validated with the experimental results of model 1 and applied for computing the static pressure of model 2 with the new airfoil (see Fig. 6). (a): Validation of the LBS-Code. (b): Computation of static pressure curves. Figure 6: Performance computations with the DLR Lifting Surface Code LBS. In a second computation the planform was optimized in aeroacoustics to obtain a further noise reduction of 3 db(a) by sweep (see Fig. 7). However, this optimized planform was not investigated due to the strong centrifugal forces which appear up to 1000 kp at an rpm of 2600. Fig. 8 shows, that the fan module 2 is aerodynamically equivalent to module 1 at the design point. Outside the design point the efficiency of module 2 is very much smaller. The reason for the losses at lower flow rates is probably a bubble on the upper side of the airfoil as could be shown by laminar RANS CFD-computations [3], (see Fig. 9). The acoustic results of module 2 confirm the earlier results of the DLR2-airfoil: Fan model 2 shows a noise reduction of 4 db(a) for both, with and without the cooler (see Fig. 10). From simple analyses it follows under consideration of the experimental values that the noise level of the cooler is 11 db higher than the noise level of the fan. Therefore, in the case of a module the noise reduction at the fan has to be more than 4 db(a). This indicates that the fan model 2 generates another mass flow which reduces the noise of the cooler. To reduce the peak level at the blade passage frequency, the position of the fan model 2 inside the duct was changed till a minimum noise level at the fan location L = 13 mm was found (see Fig. 11). The difference between the minimum tone noise level and the noise level at L= 33 mm is about 8 db. This reduces the Overall Noise Level by about 2,5 db(a) as can be seen in Fig. 12a. Thus, all together the total noise reduction of fan module 2 is more than 6 db(a). On the other side, the change of the performance with L is relatively small and can be accepted. E.g., the static pressure difference between the two different fan positions of L is 6 % only (see Fig. 12b). 5 - CONCLUSIONS A test rig was put up which fulfills the requirements of DIN 24 136/2. To improve the efficiency and the aeroacoustics of a cooling fan for busses two full-scale model fans were designed and measured. The 1 st

5 (a): Fan model 2 with (b): Fan model 2 with optimized DLR2-airfoil. sweep. Figure 7: Geometry modifications for noise reduction. (a): Static pressure. (b): Efficiency. Figure 8: Performance of the fan modules reference fan, model 1 and model 2. model was designed with the radial equilibrium method. As a module it delivers 15 % more flow rate at the design point which increases the engine cooling temperature by 3 K. However, because of the high flow rate the cooler is about 11 db(a) more noisy than the fan. Therefore, the module is still to noisy by 2 db(a). To improve the acoustics of the fan, the NACA65 airfoil was exchanged by a proven laminar DLR airfoil for fans with less camber. The loss in camber was compensated by an according increase of the twist. Finally, at the design point the module 2 shows the same aerodynamic performance as module 1 but the noise was reduced by more than 4 db(a), probably caused by a better mass flow. Further 2,5 db(a) noise reduction could be obtained by optimizing the location of the fan inside the duct. Because of the high flow rate the efficiency could be increased by 5 % only. The benefit was obtained due to a better fan blade design and halving the size of the slit. ACKNOWLEDGEMENTS The author wishes to acknowledge Mr. J. Rosenkranz and Mr. H. Suhr for initialising and supporting this project as well as Mr. J. Huebner and Dr. Ch. Ehrhard for the technical management and the rest of the technical staff of the Evobus GmbH, Ulm, for their cooperative work. Furthermore, the author is indebted to Prof. U. Stark and Mr. W. Bookjans, TU Braunschweig, for the aerodynamic design and Prof. Beelte, Mr. C. Oppermann, Mr. R. Sabath and Mr. R. Jassens from the FH BraunschweigWolfenbuettel for putting up the test rig, conducting the experiments and data acquisition and for the fruitful discussions. REFERENCES 1. D. Lohmann, Prediction of Ducted Radiator Fan Aeroacoustics, In DGLR/AIAA 14th AEROACOUSTIC CONFERENCE, Aachen, Germany, pp. 576-606, 1992 2. U. Stark and al., Kennlinienberechnung fuer Axialventilatoren mit gesichelten Schaufeln, FortschrittBerichte VDI, VDI-Verlag, pp. 1-59, 1999

6 Figure 9: Bubble causing losses at 5.6 m3 /s. 3. D. Lohmann and al., CFD-Analysis of Fan Aeroacoustics, In 5th Int. Congress on Sound and Vibration, University of Adelaide, Australia, pp. 669-690, 1997

7 Figure 10: OASPL of the 3 models. (a): Spectra. (b): Peak level of BPF over L. Figure 11: BPF noise level at different fan positions L. (a): OASPL variation over L. (b): Static pressure variation over L. Figure 12: OASPL and static pressure at different fan positions L.