Bench Model of Electrical Control System for Inflatable Hemi- Spherical Structure

Similar documents
Boiler Steam Water Drum Automation using D.C.S

Implementation of Auto Car Washing System Using Two Robotic Arms

Fin-Fan Control System

Implementation of Multivariable Self Tuning Temperature Controller and LIW Feeder for an Extruder Machine

II. METHODS AND MATERIALS

Continuous, real-time detection, alarming and analysis of partial discharge events

[Patil* et al., 5(7): July, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

Intelligent monitoring system for automobiles

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Leak Detection. Ron Threlfall Manager, Leak Detection, Maintenance and Integration

Design & Control of an Elevator Control System using PLC

Automated Polyhouse for Optimal Growth of Plants

Intelligent Fire Detection and Visual Guided Evacuation System Using Arduino and GSM

The IPPS was developed on IBM-PC platform under QNX real time operating system (RTOS) and uses QNX-Windows GUI.

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

Design specifications and test of the HMPID s control system prototype in the ALICE experiment

Real Time Automation Applications Using Millenium Crouzet PLC

PLC Based Washing Machine

A Cost Effective Embedded Design for Security and Automation in Industries

"A Case Study of Three Drum Parameter Control in Boiler Using Discrete PID Controller Based on Simulation"

Design and Development of General Purpose Alarm Generator for Automated System

SYNERGY IN LEAK DETECTION: COMBINING LEAK DETECTION TECHNOLOGIES THAT USE DIFFERENT PHYSICAL PRINCIPLES

International Journal of Advance Engineering and Research Development DESIGN OF TEXTILES INDUSTRIES BATCH MANGEMENT USING PLC AND SCADA

ENACTMENT OF SCADA SYSTEM FOR JUDICIOUS DWELLING

BOILED WATER TEMPERATURE MEASUREMENT SYSTEM USING PIC MICROCONTROLLER

C&I SYSTEM DIAGNOSTICS WITH SELF MONITORING AND REPORTING TECHNOLOGY (SMART)

POWER PLANT MONITORING AND CONTROL USING GSM MODEM Syed Zeeshan Ali* 1, Abhijeet Bajpayee 2

Smart Personal Security Alert Walking Stick For Visually Challenged People

GSM BASED GARBAGE AND WASTE COLLECTION BIN OVERFLOW INDICATOR

Autonomous Waste Sorter Design Project

For Complete Fire and Gas Solutions

Performance Neuro-Fuzzy for Power System Fault Location

Lecture 4 Power System Protection. Course map

6340(Print), ISSN (Online) Volume 4, Issue 2, March - April (2013) IAEME AND TECHNOLOGY (IJMET)

GSM Based Computer Lab Security System Using PIR Sensors

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

6367(Print), ISSN (Online) Volume (IJCET) 3, Issue 2, July- September (2012), IAEME

AUTOMATIC STREET LIGHT CONTROL SYSTEM USING MICROCONTROLLER

Temperature Control of Heat Exchanger Using Fuzzy Logic Controller

MECHANICAL VACUUM BOOSTERS:-

Sequence of operation

CTT8 TEMPERATURE MONITOR DEVICE

Real Time Pipeline Leak Detection on Shell s North Western Ethylene Pipeline

Wearable Carbon Monoxide Warning System Using Wireless Sensors

RAMSES: THE LHC RADIATION MONITORING SYSTEM FOR THE ENVIRONMENT AND SAFETY

CONVENTIONAL FIRE CONTROL PANELS FS 5100 and FS 5200

Android Controlled Fire Fighting Robot

AUTOMATION OF BOILERS USING LABVIEW

RLDS - Remote LEAK DETECTION SYSTEM

MO n : 12JMC rév A

Proceedings Design, Fabrication and Optimization of a Silicon MEMS Natural Gas Sensor

IoT Based Fire Alarm and Monitoring System

Solar Drying Techniques And Performance Analysis: A Review

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

Boiler drum level controller using Microcontroller

Remote Environment Monitoring & Detection Tribot

DATA SHEET BENEFITS CURRENT CHALLENGES SSM INFOTECH S X-FORCE AMS - THE IDEAL SOLUTION

CONTROLLING POWER PLANT BOILER AND DRAFT FAN USING LABVIEW

A Design of IADSS with the Earthquake Detecting Function

Smart Building using IBM Watson

Hazardous Gas Detection using ARDUINO

New fire control system design for fire fighting and rescue equipment Jianguo LUO1, a, Zehao BU2, b

DRAGER MONITORING, DETECTION OF GAS HAZARDOUS AND AUTOMATIC BOOKING

A Microcontroller-Based Monitoring System for Batch Tea Dryer

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

A study of Transient Performance of A Cascade Heat Pump System

Smart Intrusion Detection

APPLICATION OF CFD SIMULATIONS FOR LOCATING OUTDOOR UNITS ON HIGH RISE TOWER Basant Kumar Gupta 1, Anand Patil 2

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Development of Smart Phone Applications Linked with Fire Alarm Control Panel in Automatic Fire Detection System

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Virtual Boundary System Using Passive Infrared Sensor

Microgrid Fault Protection Based on Symmetrical and Differential Current Components

Design and Development of Industrial Pollution Monitoring System using LabVIEW and GSM

Post Accident Monitoring in PFBR Safety in Nuclear Power Plant

Laptop / PC Programming Manual

Fire Fighting Robot Controlled Using Android Application

Methods of Software Integration of Alarm Systems

Real Time Smart House Data Logging System Using LabVIEW


INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

EXPLORING POSSIBILITIES WITH THE DEVELOPMENT OF THE LOOP HEAT PIPE TECHNOLOGY. Roger R. Riehl

Numerical study of heat pipe application in heat recovery systems

Interactive Fire Control Panel IFS7002 four signal loops Instruction Manual

Smart Gas Booking and LPG Leakage Detection System

CITY OF WHITEHORSE SERVICING STANDARDS MANUAL SECTION 2 - CONSTRUCTION DESIGN CRITERIA SUB-SECTION 2.A SCADA STANDARDS.

Project Number: P15441

Milsoft Amelia Island June 12-14, 2018

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

Development of a Sensing Module for Standing and Moving Human Body Using a Shutter and PIR Sensor

An Embedded System for Detecting Seed Flow in the Delivery Tube of a Seed Drill

Computer Controlled Recycle Loops Unit TRLC

Functional Safety Solutions

Effects of Volute Tongue Clearance and Rotational Speed on Performance of Centrifugal Blower Nitin S. Jadhav *, S. R. Patil

Technical Paper. Auto tuning and motor protection as part of the pre-setting procedure in a heating system

Energy Commander Paralleling Switchgear

Experimental Studies on Aero Profile Thermosyphon Solar Water Heating System

THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE

Process Safety - Market Requirements. V.P.Raman Mott MacDonald Pvt. Ltd.

FIRE AND GAS DETECTION WITH GSM ALERT

Transcription:

Bench Model of Electrical Control System for Inflatable Hemi- Spherical Structure Sunil Kumar *, R. Shyam **, Amitabha Pal, P.Bala Subramaniam,,Narendra Singh Aerial Delivery Research & Development Establishment, Agra 282001, India Email: * mr.sunil.kr@gmail.com, ** drrs53@ rediffmail.com, Abstract The Development of Bench Model of Electrical Control System for Inflatable Hemi Spherical Structure (IHSS) is presented in this paper. Electrical control system is used for controlling the Air Blower System, Air Conditioning System and monitoring of complete IHSS. Electrical Control System also provides the modes of control such as Auto Control, Remote Control and Local Manual Control. A bench model is developed for achieving all these facilities and verifying design concept. Keywords:-Inflatable, Control System, Bench Model, Simulation. 1. Introduction Development of such radar and electronics equipments is always required in Defence, which can work in adverse geographical and environment condition. For achieving highest working of Radar and electronic equipments in adverse condition, the control of temperature, humidity and other environmental factors is very important. For these, the controlled environment can be provided by the IHSS. IHSS is a light weight and flexible structure made of coated fabric which provides the controlled environment in limited area for working of Radar. Due to transparent fabric for Micro-waves, it does not affect the working of Radars. IHSS consists of Fabric Structure (without any metallic support), Air Blower System, Air Conditioning System, Electrical Control System and Emergency Power Backup System (EPBS). Electrical Control System is one of critical part of IHSS which controls the other part of IHSS such as Air Blower System and Air Conditioning System. Electrical Control System maintains the shape of structure and temperature inside of IHSS by controlling the Air Blower System and Air Conditioning System with the help of Differential Pressure Sensors, Wind Speed Sensors and Temperature Sensors. The IHSS system is shown in Fig. 1. For developing the technology of Electrical Control System, the bench model is developed. Figure1 Inflatable Hemi Spherical Structure (IHSS) system 2. ELECTRICAL CONTROL SYSTEM Watermark embedding algorithm Electrical Control System is used to control Air Blower System to maintain the Hemi spherical shape of flexible structure of IHSS. It is also used to control the Air Conditioning System for maintaining the temperature inside of IHSS. Block Diagram of Electrical Control System is shown in Fig.2. For controlling the Air Blower System and Air Conditioning System, the signal from Differential Pressure Sensors, Wind Speed Sensors and Temperature Sensors are used in Electrical Control System. Differential Pressure Sensors are used for measuring the differential pressure of IHSS. This differential pressure maintains the Shape of Fabric Structure without any solid metallic support. The differential pressure of IHSS is maintained by pushing the air inside the structure using the Air Blower System. For Controlling the Air Blower System, the deferential pressure and Wind Speed is measured and corresponding signal of sensors are sent as feedback to the Electrical Control System. For example: if wind speed is less than 50Kmph, to maintain a differential pressure of 3mbar, control of one blower 1

is required. If wind speed is more than 50Kmph, a differential pressure of 9mbar is required to be maintained. For controlling the Air Conditioning System, Temperature sensors are used for temperature measurement and feedback signal is sent to Electrical Control System. On failure of Power Supply from Grid, Electrical Control System operates the emergency Air Blower of Air Blower System through EPBS and keeps off all other Air blower and Air Conditioners. All information of IHSS is send to Remote Operating Station for monitoring purpose. Same information is also displayed at panel of Electrical Control System. Electrical Control System also schedule the operation of Air Blowers of Air Blower System and Air Conditioners of Air Conditioning System, i.e. after a certain time period, the duties of Air Blowers or Air Conditioners are changed. First Air Blower will work as second Air Blower and Second Air Blower will work as First Air Bower. Electrical Control System provides the Auto Control mode, Remote Control mode and Local Manual Control mode for controlling the Air Blower System and Air Conditioning System. Fig.2 Configuration of Electrical Control System Fig.3 Bench Model of Electrical control System 3. NEED OF ELECTRICAL CONTROL SYSTEM Inflatable Structure is a hemispherical structure of coated fabric without any solid metallic structure and provides a controlled environment in limited area. For maintaining the shape of IHSS and temperature in it, Air Blower System and Air Conditioning System are used. Electrical Control System is required for controlling the Air Blower System and Air Conditioning System. Electrical Control System is required for following purpose:- For maintaining the hemi spherical shape of Inflatable Structure. For controlling of Air Blower System and Air Conditioning System as per requirement. For Auto control of Air Blower System & Air Conditioning System. For Remote control of Air Blower System & Air Conditioning System. 2

For Manual control of Air Blower System & Air Conditioning System. For maintaining required Differential Pressure, if wind speed is less then 50Kmph. For maintaining required Differential Pressure, if wind speed is more then 50Kmph. For maintaining temperature comfortable range inside of IHSS. For transferring the requirement on other Air Blower, on occurrence of failure of one Air Blower in Air Blower System. For transferring the requirement on other Air Conditioner, on occurrence of failure of one Air Conditioner in Air Conditioning System. For maintenance of Air Blower and Air conditioner without shut down of IHSS. For monitoring of various parameters for complete IHSS. For controlling of emergency blower with EPBS on failure of redundant main power. Sending alarm to panel/remote location in case of failure of any Air Blower or Air Conditioner. 4. BENCH MODEL OF ELECTRICAL CONTROL SYSTEM For development of Bench Model of Electrical Control System, the Air Blower System and Air Conditioning System have to be simulated. The Bench model of Electrical Control System is shown in Fig.3. The main components of Bench Model are marked in Fig.3. Programmable Logic Controller (PLC), Supervisory Control and Data Acquisition (SCADA) view, Relay and Power Supply are the main components of Bench Model of Electrical Control System which control the simulated Air Blower System and Air Conditioning System. For simulating the different operating conditions for Electrical Control System. Signal, Fault and Manual Control (SFMC) simulator is used. Auto Control, Remote Control and Manual control mode of Electrical Control System is developed in Bench Model. 4.1 Simulated Air Blower To maintain the differential pressure of IHSS, three Air Blowers are used as Air Blower System for pressurization of Air. In Bench model of Electrical Control System, this Air Blowers System is simulated. For simulating this, two Blower fan (Blower Fan1 as Air Blower-1, Blower fan-2 as Air Blower-2) and one LED (as Air Blower -3) is used as Air Blower of Air Blower System. Simulated Air Blower system is shown in Fig.4. 4.2 Simulated Air Conditioner Three Air conditioners are used as Air Conditioning System in IHSS. These are simulated by indicator in Bench Model of Electrical Control System. Each Air Conditioner is simulated by three indicators - Blue indicator as cooling system of Air Conditioner, yellow indicator as fan of Air Conditioner and third red is heating system of Air conditioner. Simulated Air Conditioner System is shown in Fig.5. 4.3 Programmable Logic Controller (PLC) The decision for operation of Air Blower system and Air Conditioning System is made by Programmable Logic Controller (PLC). The simulated feedback signals of sensors are used in PLC and low power control signal are generated for controlling the Air Blower System and Air Conditioning System by PLC. For making the decision for operation, PLC is programmed for automatic control of system and also provides the remote control of the system. PLC is also programmed for SCADA view. Pictorial View of PLC is shown in Fig. 6. 4.4 Relay Relay are used for isolating the low power control signal generated from PLC and amplify these for operation of Air Blower System and Air Conditioning System. 4.5 SCADA View SCADA View is used for displaying the information regarding differential pressure and inside temperature of IHSS, wind speed in external environment and information of faults. It is also used for monitoring the operation of Air Blower System and Air Conditioning System of IHSS in remotely located Operating Room. It is developed with the bench model and can give the information about IHSS operation at remote. SCADA View is shown in Fig.7. SCADA View is also used for remote control of the Air Blower System and Air Conditioning System. For remote control of Air Blower System and Air Conditioning System, the switch on SCADA View is provided. SCADA view is programmed with PLC for the Remote Control Mode. 4.6 Power Supply Power Supply provides the power for bench model of Electrical Control System and for operation of Air Blower System and Air Conditioning System. 4.7 Signals, Fault and Manual Control (SFMC) Simulator SFMC Simulator is used to simulate the sensors output signals, Faults in Air Blower System and Air Conditioning System. In Bench Model of Electrical control System, the Local Manual Control is also simulated on this same simulator. With SFMC simulator, the sensors output signals according to Differential Pressure and Temperature of IHSS, and Wind Speed in external environment are simulated and various operation condition for IHSS are created for operation of the Electrical Control System. Fault in Air Blower system and Air 3

Conditioning System, power failure is also simulated with SFMC. The manual control for operation of Air Blower system and Air Conditioning System can be done with SFMC simulator. SFMC Simulator is shown in Fig. 8. 5. WORKING In Bench Model of Electrical Control System, Simulated Air Blower System and Air Conditioning System are controlled. The Effect of differential pressure of IHSS due to air pressurization by Air Blower System is simulated by SFMC simulator. Similarly the effect temperature variation due to Air conditioner and wind speed in external environment is simulated by SFMC simulator. SFMC simulator generates simulated signals of sensors of IHSS and faults according to different situation. These signals are used in PLC and according to program, PLC generate control signal for operation of Air Blower System and Air Conditioning System with these simulated signals. These signals are isolated and amplified by relays and simulated Air Blower System and Air Conditioning System is operated by relay. Auto control mode, Remote control mode and Local Manual control mode is developed in bench model of Electrical Control System. 5.1 Auto-Control Mode In this mode, Electrical Control System is controlled automatically by the PLC. When signal of differential pressure, temperature and wind speed correspond to 3mbar, less 19 C or more than 25 C and 50KmpH respectively are generated by SFMC simulator, PLC generates the control signals for one Air Blower of Air Blower system and one Air conditioner of Air Conditioning System according to programming and if differential pressure is less than 2mbar, PLC generates the control signals for two Air Blowers. If any Air Blower or Air conditioner is faulted in Bench Model, the corresponding fault signal is generated by SFMC and gives it to PLC and PLC stops the operation of that Air Blower or Air Conditioner and starts the operation of another one. When all the Air Blower or Air Conditioner are in healthy condition, PLC changes the duty of first and second Air blower or Air Conditioner after a certain time period. If SFMC simulator generates the signal of wind speed which corresponds to more than 50KmpH, PLC generates the control signal for Air Blower to maintain 8mbar differential pressure and if differential pressure is less than 5mbar, it operates two Air Blowers. If temperature signal for less than 16 C or more than 29 C and less then 13 C or more than 32 C are generated from SFMC simulator, PLC generate two and three Air conditioners respectively. Fig.4 Simulated Air Blower System Fig.5 Simulated Air Conditioning System 4

5.2 Remote Control Mode In this mode of control, Electrical Control System is controlled from SCADA View on Computer. The program of PLC is interrupted from the SCADA. SCADA is used as user interface for generate the control signal of PLC which controls Air Blower System and Air Conditioning System. For controlling the Air Blower System and Air Conditioning System from SCADA, there are separate switches on SCADA for each Air Blower and Air Conditioner. 5.3 Local Manual Control Mode In this mode, Electrical control System is controlled manually. PLC is by passed by manual control signal from SFMC simulator and Air Blower and Air Conditioners are controlled manually by generating the control signal from switch given in SFMC simulator for manual control. In all control modes, the information regarding operation of Air Blower, Air Conditioner and Sensors and their fault is displayed on SCADA View. Fig.6 Programmable Logic Controller (PLC) Fig. 7 SCADA View 5

Fig. 8 Signal, Fault and Manual Control (SFMC) Simulator 6. CONCLUSION The Bench Model of Electrical Control System is very helpful for understanding the functionality of the actual Electrical Control System. Auto Control mode, Remote Control mode and Local Manual Control mode is developed for Electrical Control System in Bench Model. This Bench Model is base for testing the Programming of PLC for Electrical Control System and modification in programming of PLC can be tested. The bench model of Electrical Control System can be used for training of operator for Actual System. On the basis of bench model, prototype model of Electrical Control System is also being developed, which will be used for testing of functioning of other subsystems of IHSS. Acknowledgement The authors are extremely thankful to all those involved in Development of Bench Model of Electrical Control System for IHSS. We are thankful to DIRECTOR, ADRDE for giving us motivation and moral support. Authors also wishes to acknowledge the support of the team members involved in Development of other systems of IHSS. 7. REFERENCE [1] Balraj Gupta, Aerial Delivery Systems and Technologies, Defence Science Journal, Vol. 60, No. 2, March 2010, pp. 124-136. 6