MRXBOX95AB-WH2 (with automatic summer bypass)

Similar documents
MRXBOXAB-ECO2 MRXBOX-ECO2

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOX95-WH1 MECHANICAL VENTILATION WITH HEAT RECOVERY

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR)

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

The Range HIGHEST INDOOR AIR QUALITY IN NEW HOMES

Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

OPUSXBOX - SMALL COMMERCIAL HEAT RECOVERY SYSTEM LOW DEPTH, HEAT RECOVERY UNIT WITH MULTIPLE SPIGOTS AND ECOSMART CONTROLS.

IMPROVING INDOOR AIR QUALITY IN NEW HOMES. MECHANICAL EXTRACT VENTILATION (MEV & dmev)

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

Installation and Maintenance

OPUS PLUS TWINFANS COMPACT & POWERFUL, IDEAL FOR LARGER ROOM APPLICATIONS WHILST MAINTAINING LOW NOISE LEVELS.

Lo-Carbon Sentinel Kinetic Horizontal

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

Installation and Maintenance

Installation and Maintenance

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

Installation and Maintenance

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

SPECIFICATION GUIDE. Tel DOMUS VENTILATION

Installation and Maintenance

Small Room Heat Recovery Ventilation

Installation and Maintenance

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

MRXBOX95-WALL. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Extract air.

Installation and Maintenance

The Sentinel Kinetic Horizontal Range

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

MRXBOX95AB-WH1. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Wall Mounting. Installation and Maintenance

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

Lo-Carbon Sentinel Kinetic Range Overview

MEV Ecosmart. Installation and Maintenance. Continuous Mechanical Extract Ventilation Units. 1.0 Introduction

Lo-Carbon Sentinel Kinetic Range Overview

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

MRXBOX95-WM2. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

ONE FAN FITS ALL CYFAN CENTRIFUGAL EXTRACT FAN

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

FLAT2000L/R. Low Energy Positive Input Ventilation Unit. Installation and Maintenance. Alternative inlet position. 2.1 Spigot Inserts.

MEV-DC. Continuous Mechanical Extract Ventilation Units Installation and Maintenance. Figure 3. Fixing screw hole.

SLIMAIRE 230V & 12V SINGLE SPEED FANS

ENERGY RECOVERY VENTILATION (ERV)

HRXD MVHR UNIT Mechanical Ventilation with Heat Recovery.

MRXBOX95-WM2H. Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance

Sentinel Demand Energy Recovery Ventilation

CREATING A HEALTHY INDOOR ENVIRONMENT POSITIVE INPUT VENTILATION (PIV)

Domestic & Commercial Fans

MODEL: BV400 Part No:

RESIDENTIAL VENTILATION DUCTING SOLUTIONS

energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

VENTILATION FOR STUDENT ACCOMMODATION

Kair. ieco 4 RANGE. Appendix Q Eligible VENTILATION LIMITED. Continuous Mechanical Supply and Extract Ventilation with Heat Recovery

HOTLINE:

DRI-ECO-HEAT-HCS Whole House Ventilation Unit with Hall Control

Building Regulations 2010: What it means to you.

KOMFORT EC DB Suspended heat recovery air handling units

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

Decentralised Mechanical Extract Ventilation 2 Speed Axial Extract Fan with Humidity Enabler Installation Guide

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

Apartment Ventilation. "Microbox" Continuous Mechanical Extract Units

DRI-ECO-LINK-HC 1.0 INTRODUCTION 4.0 DIFFUSER INSTALLATION 2.0 IMPORTANT NOTES TO INSTALLERS 3.0 LOFT INSPECTION

The new Xcell EC High Efficiency Range Fresh air pure and simple

CI/SfB (57.7) 2nd edition

DRI-ECO-HEAT-HC. Whole House Ventilation Unit with Hall Control. Installation, Maintenance and Operation

WIDE RANGE OF ENERGY EFFICIENT HEAT RECOVERY UNITS WITH OPTIONAL INTEGRATED CONTROLS.

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

WHHR Midi & Midi Lite

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

230V/24V DC SELV Surface and Semi-Recessed Mounted Domestic Fans INSTALLATION AND MAINTENANCE. n Wall mounting kit

Sentinel. Kinetic MVHR Range. Installation & Commissioning. Stock Ref. N PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Thank you for choosing EnviroVent

FLUEBOOST. flueboost 350 gas fire model

Installation and Maintenance. Opus OK / Genie NKF1 Kitchen Extract Unit. Contents IMPORTANT WARNING IMPORTANT! Introduction WARNING!

dmev Unit Quietest dmev available. Discreet, tasteful styling. Single fan for use in all applications.

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Installation & Commissioning

Intelligent Air Solutions

HRU ECO 3 RF APPENDIX Q ELIGIBLE NEW

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7

INTRODUCTION Flexibility Is The Key Simple Access For Maintenance

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

Efficient Cooling and Heating. Flexibility Is The Key

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

Thank you for choosing EnviroVent

POWERCUBE - CENTRAL EXTRACT SYSTEM

7 YEAR. The DRIMASTEReco Range DRI-ECO-HC NUAIRE S PIV: HALL CONTROL

Panther Fan Coil Unit

Transcription:

MRXBOX95AB-WH (with automatic summer bypass) MRXBOX95AB-WH is designed to provide optimised balanced (supply and extract) mechanical ventilation with heat recovery. Tempered air is delivered into living areas whilst extracting moisture laden air from wet areas, creating comfortable well-ventilated homes. The unit has been designed with automatic summer bypass and the facility to commission the supply & extract fans independently on both minimum and maximum speeds. This unit is listed on the Product Characteristics Database. Typical Installation ISTAATIO FEATURES Filter being removed Filter cover Filter Code MVHR-WH-FITERKIT Typical cupboard installation of MRXBOX95AB-WH 46

Performance - MRXBOX95AB-WH Fan Static Pressure (Pa) 800 700 600 500 400 300 ISO 580 007 AMCA 300 V Type D Air Density. kg/m CODE DESCRIPTIO MRXBOX95AB-WH 3 4 5 6. Multi-room supply and extract heat recovery. Product range 3. Efficiency 4. Automatic Summer Bypass 5. Wall/cupboard application 6. High Model 00 00 0 0 40 80 0 60 80 00 Air Volume Flow Rate (l/s) Sap Appendix Q Test Results MRXBOX95AB-WH Application Specific Fan Power (W/l/s) Heat Exchange Efficiency Energy Saving Trust Best Practice Compliant Kitchen + Wet Room 0.60 89% Yes Kitchen + Wet Room 0.6 88% Yes Kitchen + 3 Wet Room 0.68 88% Yes Kitchen + 4 Wet Room 0.79 87% Yes Kitchen + 5 Wet Room 0.95 86% Yes Kitchen + 6 Wet Room.5 85% Yes Kitchen + 7 Wet Room.38 85% Yes Electrical & Sound Maximum power consumption Sound Power evels db re pw dba @3m Curve (Watts) 63 5 50 500 K K 4K 8K Curve 337 Open inlet 58 56 57 63 57 5 46 45 6 Open Outlet 67 63 65 75 68 63 56 53 Breakout 6 6 60 63 53 48 40 35 Above noise measured at stated percent of maximum working pressure.. 47

Technical - MRXBOX95AB-WH DIMESIOS (MM) Weight - 44Kg View from top 39 485 = = Ecosmart connection grommets 4 x Spigots 80mm Internal Diameter 00mm External Diameter 90 Dimensions: Unit wall mounting bracket position (Viewed from back) Front view Side view Mounting = = 70 Humidistat adjustment 534 00 76 5 Fixing Points Bracket to be fitted to the wall Condensate drain B3mm outside 40.0 CRS 40.0 CRS 70 585 49 CRS 67 67 Detail of unit control on front panel. The status of the unit is indicated by a series of ED s on the front cover. The varients are listed below. ormal Mode Boost Summer Boost Frost Protection Summer Bypass Filter Change Supply Fan Fault Extract Fan Fault Ventilation Controls + - + - - + - + + - + - For commissioning: refer to user manual Post commissioning remove adhesive backing under this section Power 060905 Tamper proof label following commissioning, includes system status indication. 48

Electrical Details - MRXBOX95AB-WH Please note: the electrical connection of the unit must be carried out by a qualified electrician. The unit is supplied with a flexible cord for connection to the mains supply. OTE: In the event of kv transients the fans may stop running, normal operation will be resumed when the interference has ceased. The mains power supply cable should be connected to a fixed wiring installation, via a fused isolator, in accordance with current IEE wiring regulations. EECTRICA DETAIS: MRXBOX95 - WH Voltage: ph Consumption:.5 Amp Fuse rating: 5 Amp Wiring ote: Wiring is for reference purposes only as the connections are factory fitted. The unit is pre-wired with a metre fly lead. UIT SERVIG KITCHE & BATHROOM Pole Green/Yellow Blue Brown Black Grey UIT SERVIG OE BATHROOM ight switch (Double Pole) Room light UIT SERVIG TWO BATHROOMS 3 Pole Green/Yellow Blue Brown Black Grey ight switch (Double Pole) Room lights 3 Pole 49

Consultants Specification OPERATIO The supply and extract ventilation unit shall be positioned as indicated on the drawings and shall be in accordance with the particular fan schedule in the specification. The combined supply and extract with heat recovery unit, shall supply filtered fresh air to each of the habitable rooms and vitiated air shall be extracted from the wet areas e.g. bathroom, en-suite, w.c, kitchen, utility rooms, etc. The supply air shall be pre-heated by the warm extract air via the integrated counter-flow heat exchanger element. The extracted air shall also be filtered before it reaches the heat exchanger block. The ventilation unit shall vary its speed and therefore the ventilation rate, as it receives signals from one of the following: Switched live signal from light / remote switches. When signals are received, the fan shall alter its speed to adjustable, normal and boost rates. The unit shall have the facility to commission the supply and extract fans independently on minimum speed (continuous background ventilation), boost speed, via inbuilt minimum and maximum speed adjustment. The fans shall have infinitely variable speed control. MRXBOX95AB-WH - SPECIFICATIO The unit shall be fully insulated providing excellent thermal and acoustic characteristics and shall be complete with a multi plate counter flow high efficiency heat exchanger block, with a thermal efficiency of up to 95%. The heat exchanger shall be protected by G3 grade filters on fresh air inlet and system extract. The heat exchanger and filters shall be accessible via the front access panel, enabling quick and easy maintenance. The unit shall have low energy, high efficiency EC fan/motor assemblies with sealed for life bearings, the impellers shall be backward curved centrifugal type. The motors shall be suitable of an ambient temperature of 40 C. The unit shall be supplied complete with a condensate drip tray and 3mm drain connection. The unit shall be suitable for 80 and 00mm diameter circular ducting. ote: The unit is also available in opposite handed format, refer to spigot configuration for set up. The breakout noise level and power requirements shall be as detailed by the unit manufacturer and in accordance with the ventilation equipment schedule. Units shall be MRXBOX95-WH or MRXBOX95AB-WH as manufactured by uaire and shall be listed on the Sap Appendix Q database. ITEGRA AUTOMATIC SUMMER BYPASS The bypass damper shall open automatically via a wax actuator allowing the air to bypass the heat exchanger to deliver fresh filtered air during the warmer months. ITEGRA HUMIDITY SESOR The integral humidity sensor incorporated within the extract fan chamber will automatically boost both the extract and supply fan, to the commissioned boost speed, when the humidity level exceeds that set by the side panel mounted adjustment potentiometer. OPTIOA REMOTE SWITCH (MRXBOX95-3 SWITCH) The unit shall have the facility to wire a three position remote switch to a suitable location within the property. The switch shall have 3 settings, trickle, boost and summertime boost facility. The remote switch will act as the master switch and will override all other switches. COTRO OPTIOS All versions shall have the following functions integrally mounted within the fan unit on a purpose made PCB, all such components pre-wired and factory fitted by the manufacturer: Independent control of background supply and extract flow rates. Independent control of boost speed supply and extract flow rates. Integral fan failure indication. Integral S/ terminal for boost to commissioned level, from remote switch, e.g. light switch. Integral S/ terminal for summertime boost speed, from remote switch e.g. plate switch. Integral heat exchanger frost protection. Discreet daily run monitor. Remote fail indicator (Part number-mrxbox95h-rfi). Indication and controls - The unit shall have clear ED visual indication for maintenance, servicing and operation mode i.e. summer bypass, frost protection. The unit shall be offered with a 5 year warranty. The manufacturer s recommendations should be observed at all times. The unit shall be the MRXBOX95AB-WH and shall be manufactured by uaire. MRXBOX-VSC (VISUA SYSTEM COTROER) The MRXBOX-VSC is compatible with the uaire MRXBOX95AB-WH heat recovery unit and can be purchased separately. The controller comes complete with commissioning and end user functions. The display will be a 3. CD display and will remain on standby until such time the screen is touched. The initial display will show the MVHR system status as listed below: Current Fan Speed Current indoor/outside temperature Indicate when the summer bypass is activated Indicate when frost protection is activated Indicate when the filters require cleaning/changing. 50