FURNISHED 5x5m 25-28 February 2019
Package Lockable tent with 2 keys Contravision busgraphic vinyl on front façade Entrance tent fascia Graphic with booth number GSMA logo Terrace 3x5m with teak tiles and teak fence Front façade - Glass panels & 1 double door Side wall of PVC panel - 3 sides Anthracite Carpet tiles False ceiling 30db Wall & ceiling insulation Perimeter walling 2 AC floor mounted units 6,6 kw free power / 12 Kw switchboard 4 Double embedded sockets 1 RJ45 sockets 8 Embedded downlights on white wooden beams 1 Power lead for plasma screen 1 Smoke detector 1 Individual light switch per pavilion 2 Power leads for AC units Fire system connection to Fira 24h Power consumption 2MBps internet line WiFi AP enable (WiFi enable- service not included) Fire extinguisher Basic final booth cleaning before handover* Furniture 12 pax meeting room furniture set: 12 White chairs + 1 White table 2 Anthracite grey armchairs + 1 glass coffee table LCD LED screen 40 wall mounted 2 Terrace furniture set. 60 x 60 cm table teak + 4 chairs each. Full wall vinyl 485x221 cm in meeting room Polycanvas to wood frame 120x80cm in reception area 1 Black waste basket 1 Coat hanger *No cleaning is included durnig event days.
AC AC double socket RJ45 embedded lights smoke detectors AC floor unit power 2MB internet line Access point individual light switch 2219 4855 AC SV1
*Render to be updated
Contravision busgraphic vinyl on front façade Full cover of all glass, doors included Material: Busgraphics windows Dimension: 3851 x 1840mm SV1 * Graphics can be personalised by the client. * No additional branding is allowed in the outside other than the façade graphic. 1839 1837 2367 233 2600 Clear view from inside 50 831 292 679 227 679 292 831 169 831 50 233 4932 233 5398
Entrance tent fascia Graphic with booth number Material: Vinyl Dimension: 400 x 120mm GSMA logo SV1 Material: Vinyl Dimension: 600 x 120mm Terrace 3 x 5m with teak tiles and teak fence * The picture is to represent the bus graphic as heater is not included in this package
Ceiling, and perimeter walls Anthracite Carpet tiles Entrance door
8 Embedded downlights on white wooden beams 1 Smoke detector DETECTOR DE HUMO CONVENCIONAL Rev.: 1.00-04/2011 CF401 DETECTOR DE HUMO CONVENCIONAL CONVENTIONAL SMOKE DETECTOR DESCRIPCIÓN El detector de humo óptico reacciona ante la presencia de productos causados por la combustión (humo visible). El principio de funcionamiento se basa en la técnica de dispersión de la luz (efecto Tyndall). Estos detectores han sido pensados para formar parte de sistemas convencionales de detección de incendios. ndio MANTENIMIENTO Para el correcto funcionamiento del detector, tor es necesario realizar un mantenimiento periódico al menos 2 veces al año. Prueba del sensor: verificar el correcto o funcionamiento del detector mediante un generadorr de humo, prestando atención de no dañar/ensuciar el sensor. Una simulación de alarma a puede ser realizada mediante la activación del reed interno con un imán (atención: la prueba con el reed no verifica el correcto funcionamiento de la detección del humo). Limpieza del sensor: el detector se debe limpiar debidamente mediante un chorro de aire comprimido soplado en el interiorior de la cámara de detección. Desmontar el detector desenroscando los dos tornillos apropiados y abrir la cámara de detección. Una vez limpiada la cámara, volver a ensamblar el detector, prestando atención al montaje del disco de fondo (hacer que el reed interno coincida con el número 4 estampillado en el fondo). Cerrar DESCRIPTION The smoke detector reacts to the presence of elements caused by the combustion (visible smoke). The working principle is based on the light dispersion technique (Tyndall effect). These detectors have been made of conventional fire detection. MAINTENANCE For proper functioning of the detector, it is necessary to perform a yearly y periodic maintenance check of at least 2 interventions. Detector Test : verify the proper functioning of the detector through a smoke device by paying careful attention in not getting the internal chamber dirty or damage the sensor itself. An alarmarm simulation can be performed by activating the internal Reed by placing a magnet (note: the Reed test does not qualify as a smoke test). Detector cleaning : the detector must be cleaned by means of compressed air blown through the internal part of the detector. Unscrew the bottom counter-plate screws to take the internal chamber out from the detector head. Clean the chamber, reassemble by making sure that the bottom counter-plate properly matches the fitting (the part where the Reed is placed cooresponding to the n 4 of the bottom plate). Close the detector by replacing the screws without screwing too tightly. CARACTERÍSTICAS TÉCNICAS M a t e r i a l : A B S C o l o r : b l a n c o A l i m e n t a c i ó n : 1 2-2 8 V c c Absorción promedio: 50µA Absorción en alarma: 25mA Visibilidad led : 3 6 0 ( doble led ) Temperatura almacenam.: -10 C +50 C Temperatura funcionam.: -5 C +70 C Humedad relativa máxima: 93% no condensada Nivel de protección: IP20 Activación prueba magnética: sí Dimensiones (con base): mm 106Øx54h Repetidor de señal: 7.5mA ó 14.5mA N o r m a t i v a s : E N 5 4-7 Fabricado in : Italia da FDP La empresa se reserva el derecho a realizar eventuales modificaciones sin previo aviso. La garantía convencional de los productos es válida 12 meses a partir de la fecha de expedición del documento fiscal que comprueba su compra. TECHNICAL CHARACTERISTICS M a t e r i a l : A B S C o l o u r : w h i t e P o w e r s u p p l y : 1 2-2 8 V d c Normal current: 50µA Alarm current : 2 5 m A Led visibility: 360 (double led) Storage temperature: -10 C +50 C Working temperature: -5 C +70 C Max. relative humidity: 93% no condensed P r o t e c t i o n : I p 2 0 Magnetic test activation: yes Size (with base): mm 106Øx 54h Outside door current: 7.5mA or 14.5mA S t a n d a r d s : E N 5 4-7 Made in : I t a l y from FDP The manufacturer reserves the right to apply or revise modifications to its equipment without any prior notice. The conventional warranantee is valid for 12 months starting from the date of the sales document to proof of purchase released. Carretera N-340 Km 1245,3 Nave B-5 Polígono industrial El Pla 08750 Molins de Rei, Barcelona (España) Tel. (+34) 93 680 03 76 Fax. (+34) 93 680 00 96 www.aqlproteccion.com aql@aqlproteccion.com
4 double embedded sockets 1 RJ45 sockets * *Note: Package inlcudes 2MBps internet line. Additional drops will need to be added if all available RJ45 points should be connected. Data Sheet 1 Individual light switch Cisco Aironet 3800 Series Access Points The Cisco Aironet 3800 Series Wi-Fi access points are highly versatile and deliver the most functionality of any access points in the industry. Product Overview For organizations paving the way for the new 802.11ac Wave 2 standard, the Cisco Aironet 3800 Series is the perfect solution. The access points go beyond getting ready for the new standard, providing the ultimate in flexibility and versatility. Access Point 3800 Series 2MBps Internet access line For large enterprise organizations that rely on Wi-Fi to engage with customers, the 3800 Series is a hands-off product that s intelligent enough to make decisions based on end-device activities and usage. This automation allows you to devote time to other pressing matters, secure in the knowledge that your Wi-Fi network is performing to its utmost potential. The Aironet 3800 Series is packed with the features and capabilities that have made Cisco the industry leader, at a price point that is ideal for managing wireless growth, capacity, and coverage gaps in dense indoor environments. Features and Benefits Feature Benefit 802.11ac Wave 2 Provides a theoretical connection rate of up to 2.6 Gbps per radio roughly double the rates offered by today s highend 802.11ac access points. support High-density experience Best-in-class RF architecture that provides high-performance coverage for a high density of client devices, giving the end user a seamless wireless experience. Features include custom hardware in 802.11ac Wave 2 radios, Cisco CleanAir, Cisco ClientLink 4.0, cross-access point noise reduction, and an optimized client roaming experience. Multiuser multiple-input Supporting three spatial streams, MU-MIMO enables access points to split spatial streams between client devices, to multiple-output (MU- maximize throughput. MIMO) technology Multigigabit Ethernet Providing multiple gigabit uplink speeds of 2.5 Gbps and 5 Gbps in addition to 100-Mbps and 1-Gbps speeds. All support speeds are supported on Category 5e cabling for an industry first, as well as 10GBASE-T(IEEE 802.3bz) cabling. 2 AC floor mounted units Portable AC unit with hot and cold air 3,5kw cooling power 2,9kw heating power Airflow 386-425 m3/h
Full wall branding vinyl Dimension: 4500 x 2210mm 12 Pax meeting room furniture set* 1 White table Dimension: Width: 2000 mm Depth:1000 mm Height: 700 mm 12 White chairs Dimension: Width: 440 mm Depth: 530 mm Height: 820 mm Seat Height:460 mm LCD LED 40 screen
2 armchair anthracite grey + 1 glass coffee table Terrace teak funiture set 2 sets.based on four chairs and one 600 x 600 mm table each One coat hanger One black waste basket *Subject to availability. Otherwise a similar one is placed.