The size & look of this panel is designed by our Engineers keeping in mind that even a single thing not to disturb attraction of the location.

Similar documents
GAS SUPRESSION CONTROL PANEL:

RE 102 RE Fire Alarm Control Panel. Installation, Commissioning & Operating Manual

Fire Alarm Control Panel. Installation, Commissioning & Operating Manual

Fire Alarm Control Panel. Installation, Commissioning & Operating Manual RAVEL ELECTRONICS PVT LTD.,

Excel-EN Conventional Fire Control Panel

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Electric Release Panel Wiring Tips

Installation, Operating and Maintenance Manual

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

OPERATION AND INSTALLATION MANUAL

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

RE-120GR. Fire Alarm Control Panel. Installation, Commissioning & Operating Manual

RE Fire Alarm Control Panel. Installation, Commissioning & Operating user Manual

Application, Installation, Operation & Maintenance Manual

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

EXTINGUISHING AGENT RELEASE MODULE

System 800 Addressable Fire Detection & Alarm System

Conventional Fire Alarm System 2014 V1.2

Door Release Power Supply

Intelligent Security & Fire Ltd

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

FEC400 Series. Installation Manual

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014

ORENA BRAND CONVENTIONAL (ORENA Brand) CE

Fire Alarm Control Panel. System Maintenance and Log Book

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Precept Marine Control Panel Application Guide

The Remote alarm Panel, TYPE RAPv2

INSTRUCTION MANUAL FIRE ALARM CONTROL PANEL NATIONAL MODEL : DIGITAL ERTL APPROVED AS PER IS: NATIONAL SECURITY DEVICES

Fire Alarm Control Panel EN54 2 & Operation & Programming MAN

QA16 Addressable System

Intelligent Security & Fire Ltd

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

RE 2554 RE Automatic Fire Alarm Control Panel (Protective premises Unit) Installation, Commissioning & Operating User Manual

CONVENTIONAL CONTROL PANEL FL2/4/8/12 LT-XP

SYSTEM 3400 ANALOGUE ADDRESSABLE FIRE DETECTION. (with Devices) Operating Manual Version 3.3X Issue 2 September 1996

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

Surveyor Envoy-MINI 4

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

Fire Product Catalog

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

DMWD 1 to 4 Zone Water Detection Alarm with Distance to Leak Measurement Installation and Operation Manual

Control Panel Engineering and Commissioning Instructions

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

Installation and Operating Instructions

Technical Speci fications 220V AC 50Hz or 110V AC 60Hz Accessories operational voltage. 2x 12V / 7Ah sealed lead acid gel batteries

FSTP2-2-wire 2 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS2 Issue 01 April 2012

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

USER MANUAL & MAINTENANCE GUIDE OG OO

FSTP4-2-wire 4 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS4 Issue 01 April 2012

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Document No Issue 02 operation & installation manual. ZXr-A ZXr-P

An introduction to... Sigma

IFP-2.32 Manual 1) DESCRIPTION ICAS FIRE PANEL IFP 2.32

Installation and user manual for the BiWire / Conventional Repeater Panel

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

Operation and Maintenance Manual

CW9000 Wireless Fire System. Installation Manual

CONTENTS. GST102A/104A/108A/116A Conventional Fire Alarm Control Panel Installation and Operation Manual

Fire Alarm Panel - User Manual

FIRE CONTROL PANEL. Revision 1.1 January 1997 USER MANUAL. Emergi-Lite Safety Systems Ltd Bruntcliffe Lane Morley Leeds LS27 9LL

NFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

intelligent solutions

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

RE 25AR. Agent Release Control Panel (Protective premises Unit) Installation, Commissioning & Operating User Manual

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

Interface Modules for SENTRI

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

The EN54 Part 2 and 4 Fire System

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

RP1r-Supra / VSN-RP1r+ / ESS-RP1r-Supra Extinguishing Control Panel User Manual. HLSI-MN-103I v.06 September 2017

FIRE ALARM CONTROL PANEL FVC01-08

Temporary wireless battery operated fire system from Channel Safety Systems

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

Conventional Fire Control Panel

The EN54 Part 2 & 4 Fire System

ZXSe Range Data Sheet

LF-4000 Series Conventional Fire Alarm Control Unit

AL600ULADA. NAC Power Extender. Installation Guide

Functional Performance Test

Transcription:

ITROUCTIO From very initial, we were very keen about the Security. As generation is going towards the modernization, we want to secure each life by latest technologies, in the field of safety & security products company has taken the responsibility of fire detection & alarm system by using Hi-Tech superior technologies. ABOUT THE COMPAY:- We proud to introduce ourselves, as (Brand name: AI SURAKSHA) a well known name in the field of fire alarm system. We are in this field from last 12 years. We have reached the remarkable height because of our professionalism and best qualities of one products. We have our own R & department for Researching technologies, Programming & quality control assurance. ow a days, Agni Suraksha is one of the most popular brand in the market. Agni Suraksha is continuously appointing ealers Authorized System integrator all over India. For getting knowledge of our product range you can visit our website www.asesindia.com. There are wide ranges of our products according to the requirement of customer. We manufacturers conventional as well as semi Addressable Fire etection & Alarm Systems. ABOUT THE PROUCT ASES is very proud of to introduce FIRE SCA the completely digital microprocessor based panel in Indian fire industry by using the digital technology. FIRE SCA can give you accuracy in its performance. For the ease of user there are 16 x 2 character LC display in the panel by which situation can be visually identify as well as LE. indications are also available. There are control switches in front of panel for handling ZOE ISOLATE, ALARM ACKOWLEE, LAMP TEST A RESET. There are LE display for MAIS O, SYSTEM O, LOW BATT, FIRE, CHARER O and Fault conditions in the panel. The size & look of this panel is designed by our Engineers keeping in mind that even a single thing not to disturb attraction of the location. ASES hope the satisfaction from user of this panel. This instruction manual will guide you to understand your system well. 437/2, Main Road, Mandawali Fazalpur, elhi-110092 Page 1

FEATURERS: 1. Fully confirms IS 2189 2. Operates on 230 V AC, 50 Hz AC supply 3. Battery backup with built in charger 4. Fire / fault status in unambiguous colored LE indications. 5. 16 x 2 line dot matrix LC display 6. Zone wise fire, open, short LE indications. 7. External s/w to test each zone fire, open, short status manually. 8. External s/w for reset, Silence, Lamp test. 9. Zone isolation facility with loop voltage cutoff. 10. Relay O/P for actuators. 11. Mains on, System On, Charger on, visual indications. 12. Battery Low& Common fire indications 13. Auto dialer attachable facility 14. Enough inside space for battery 15. Attachable with all types of fire detectors. MECHAICAL COSTRUCTIO The enclosure of the Panel is constructed by CRCA sheet with powder coated finish. The20mm knock outs are given for cable entry at the top of the cabinet. The panel also has a built in battery provision to accommodate 2 os. of 12v, 7Ah batteries. The front side of the panel consists of the following: a. Tactile switches. b. LE indications c. 16X2 line dot matrix LC ISTALLATIO A COMMISSIOI: ISTALLATIO The installation of the fire detection and alarm should comply with: a. The Institute of Electrical Engineers (IEE) wiring regulation. b. The Indian Standard of Fire etection and Alarm for building. c. The installation cable should not be in the area of proximity of high voltage cable or induce electrical interference. Place the panel in its mounting position and fix the panel to the wall using the slots of the four screws. Ensure the enclosure and the inner parts of the panel are given sufficient protection during installation period. All external cables are to be entered via the 20mm preformed knockouts located at the top of the panel. When the installation of all the cables has been completed, clean the interior of the enclosure ensuring all masonry debris and drilling swords are removed. 437/2, Main Road, Mandawali Fazalpur, elhi-110092 Page 2

COMMISSIOI Check the all entered wiring is correctly identified and also check the cables are free from fault conditions by a multimeter. Connect the external wiring into their respective terminals and ensure the End Of Line (EOL) resistor is placed at the last device of circuit. Prior to the initial power up of the panel, conduct the following preliminary checks: a. Check for any external signs of damage caused during installation b. Check all the PCBs are secure in its monitoring position c. Check the cables are secure and correctly connected. d. Check all the cable termination is tight & secure. e. Connect the batteries ensuring the correct polarity. All damages/faults must be rectified before proceeding Switch O the Panel. uring this period the following LE s have to glow to ensure system is in healthy condition. A. SYSTEM O B. AC POWER C. CHARER O ote: Apart from the above green LE s if any other amber or red LE is O, it is indicating respective fire or faults. Rectify the fire or faults before proceeding to any other operation. IICATORS A COTROLS IICATORS ormal: In the ormal Condition, MAIS O, SYSTEM O, ZOE O green LE s will be illuminated along with CHARI O AMBER led. There should be no other amber/red LE visual indication or audible tone. Power Fault: When power fault conditions like AC Zone Fault: When the fault OPE/SHORT is occurred in the zone, it will be identified by zone fault LE. The fault zone LE will glow continuously until the fault is rectified. ote: uring the above fault condition, apart from the specific fault identification LE, common fault relay and Local buzzer with intermittent tone will be activated. uring this time, if SILECE is activated, intermittent tone will be silenced. Fire: When Fire is detected by the control panel via the etector/mcp, the corresponding zone fire red LE will be illuminated along with the commom fire red LE. By the time hooter, potential free contact and local buzzer (continuous tone) will be activated. If SILECE is accepted by the panel after the fire, it will mute the external hooters and internal buzzer. It can be identified by silenced LE O. The FIRE LE indication will remain O condition till the panel is RESET. 437/2, Main Road, Mandawali Fazalpur, elhi-110092 Page 3

Isolation: The zone isolation can be identified by the Zone ISOLATE LE of amber colour. The O status indicates, the zone is isolated from the monitoring with loop voltage cut. The OFF status indicates, the zone is in monitoring condition. COTROLS: RESET Key: This key is used to reset the entire system. While in reset condition, all detector loop voltages are cut off up to 2 seconds for etector and MCP become reset and then voltages are put O to the loop. ote: We strongly recommend to avoid to do the RESET unless there is fire in the zone. SILECE Key: While in the faults condition, when it is pressed, the local buzzer will be silenced. uring in fire condition, the SILECE Key press mutes the external hooters and silence LE lows. LAMP TEST Key: As long as we are keeping this key in hold condition, all the LE s will glow to identify whether all the LE s are in working condition or not. ZOE TEST: For this function there are seven switches of thw different types. Four switch nemed TEST is for every zones & three other- FIRE, OPE, SHORT for test condition. Exm: For testing zone-1 fire steps to be followed- Press the zone-1 TEST switch followed by FIRE switch at the same time. B: Zone-1 fire LE will glow up, external sounder will be activated & internal buzzer will also be activated in different tone. These three condition will continue until the switches are left free. The above process will be same for OPE/SHORT condition testing for any zone. TECHICAL ATA Panel Operating Condition Operating Voltage AC Power : 220v AC, 50Hz ± 10% Standby : 24v C Operating Temperature : 0 C to 40 C Operating Humidity : 95% (non-condensing) Zone Operating Condition ormal Loop Voltage : 23v C Open Threshold Current : 4.4 ma Short Threshold Current : 35 ma Fire Threshold Current : 15 35 ma Alarm Outputs Hooter Output : 1 A (24v C) (ormal) B: Hooter output current can be increased as per customer requirement. Remote Outputs Fire Contact1 (C,O,C) : 240v AC/24v C@ 5A Fault Contact (C,O,C) : 240v AC/24v C@ 5A 437/2, Main Road, Mandawali Fazalpur, elhi-110092 Page 4

eneral Weight Size Color : Kgs (approximate) : x x mm (width x height x depth) : Broken white / Red COECTIO IARAM: Z1 Z2 Z3 Z4 H FIRE FAULT C C O C C O 1 220vAC 2 50Hz 3 X-mer 4 I/P 5 X-mer 6 O/P 12vC 24vC Batt O S: * The panel and detectors should be within the temperature range of 0 C to 40 C. * We strongly recommends you to check the panel on daily basis and the detectors on weekly basis. *Ensure 230 voltage input level before switching O the Panel. If the voltage fluctuation is more than 10% use UPS supply or voltage stabilizer. O T: *on t fix the panel/ detector in high range of vibrating area *on t put the panel cables near to the high voltage area *on t fix the panel in highly moisture surrounded area *on t connect the power cable wrongly, this will brake the warranty 437/2, Main Road, Mandawali Fazalpur, elhi-110092 Page 5

437/2, Main Road, Mandawali Fazalpur, elhi-110092 Page 6