RESIDENTIAL LIGHTING Best practices in lighting design to comply with

Similar documents
Best practices in lighting design to comply with California s Title 24 energy code

Best practices in lighting design to comply with California s Title 24 energy code

What You Need to Know About California Compliance T20, T24 and JA8 Chris Primous VP OEM National Accts and Industry Relations April 18, 2018

What s New in the 2013 Energy Code? Changes to mandatory Title 24 lighting requirements

2016 Title 24, Part 6 Reference Joint Appendices JA8 & JA10 Residential Lighting Test, Certify, & Comply

Note: A summary of the applicable code sections is shown in the CEC _Table100A.

Advances in Non-Residential Lighting Technologies

TITLE 24 ICONOGRAPHY. Iconography System

Energy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015

Code Compliance. Lightcloud. Guides for California Title 24 & ASHRAE

Energy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight

2018 Instant Lighting Rebates Product Catalog

Pacific Gas and Electric Company Energy Efficiency Rebates for Your Business. Lighting Rebate Catalog Saving energy for a brighter future

LIGHTING DESIGN STANDARDS SECTION City of Maryland Heights ZONING CODE

California s 2008 Building Energy Efficiency Standards for Residential and Nonresidential Buildings

Basics Series Surface Mount LED Fixtures. Affordable and easy-to-install, 4" and 6" fixtures. It s a. Snap

Dissecting Lighting Control Requirements ANSI/ASHRAE/IES Standard & 2013

Lighting Guidelines. Planning Services Department Corporation of the Municipality of Clarington

Reflector T2 and GU10 6,000 hours

WSA120: New Energy Codes and Lighting Controls

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

MANDATORY MEASURES. There are two major steps for exterior spaces to comply with Title 24:

Are LED s ready for Prime Time?

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Solid State Lighting

California Title Lighting and Lighting Controls Only

B. It is recognized that these standards are updated irregularly and lighting technology is changing rapidly.

LED HYBRID PATHWAY LIGHTING for The National Park Service

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

INSPECTION REQUIREMENTS: ENERGY CODE LIGHTING & ELECTRICAL NON-RESIDENTIAL

Tomorrow, at the speed of light. Long-lasting, energy-saving LED retrofit lamps

2016 BUILDING ENERGY EFFICIENCY STANDARDS RESIDENTIAL HVAC ALTERATIONS

CL001 >400 Watt lamp basecase, up to 600 Watt replacement fixture $95.00 Fixture

2018 Midstream Lighting Product Catalog

ASHRAE October 18, 2013

Technical Application Guide for PHILIPS LED Lamps

LED Lighting: Technology Selection and System Commissioning Course Number: CXENERGY1519

MANDATORY MEASURES MANDATORY LIGHTING CONTROLS (a) Area Controls: Manual controls that control lighting in each area separately

Lighting. Showroom Lighting Requirements. Introduction. Technology. Fixture and Performance

Millenium Os. Luminaire LED. For Stairwells and Public Spaces. Designed and manufactured in the USA. High Abuse Motion-Activated Lighting Product

SDG&E s Business Energy Solutions Program 2018 Product Catalog

Advanced Lighting For Office

MANDATORY MEASURES OUTDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.2)

Lighting Control Strategies. to meet code requirements save energy and improve building performance

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

Product Specifications MaxLumen MRI LED Diffused Lighting

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130)

Business Member Information Company name Billing address. City State ZIP. Installation address (if different from above) Account number.

LED RETROFIT CONVERSION KITS

Duke Tower Main Entrance Lobby Overview

Lighting Retrofit Rebate

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 26 ELECTRICAL

SECTION INTERIOR AND EXTERIOR LIGHTING FIXTURES

2017 Lighting Incentive

PSO Business Rebates Retrofit Lighting Technical Requirements

REPORT 3933 US ROUTE 11 CORTLAND, NEW YORK 13045

Fast. Precise. Versatile. UL Lighting Sciences

Nonresidential Outdoor Lighting Controls

Food Service Technology Center

SECTION LIGHTING CONTROL DEVICES AND CONTROL PANELS

2018 Business Lighting Rebate Application

Lindsey Beane. Executive Summary

ARTICLE XVI LIGHTING, NOISE AND ODOR/ODOROUS MATTER Shelby County Zoning Regulations 2013

Medical LED. Superbly balanced and colour corrected LED-modules for medical use.

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS

SENSORS. Vacancy Sensors. Occupancy Sensors A4-A7 A-1

PRESCRIPTIVE APPROACH

Technology. Occupancy & Vacancy Sensors & Timers. Technology. Occupancy & Vacancy Sensors & Timers L-2

Never forget to turn the lights off again. Motion Sensors

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL

Product Specifications MaxLumen MRI LED Diffused Lighting

A Guide for Applicants and Lighting Designers

SECTION INTERIOR LIGHTING

LED Retrofit Lighting Rebate 2017 Rebate Application

Oregon Non-Residential Building Energy Code

SECTION LIGHTING CONTROLS

2005 CERTIFICATE OF ACCEPTANCE (Part 1 of 3) LTG-1-A

Lobby Lighting Design

CS1200 WHT Pir Ceiling Mount Occupancy Sensor

1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

2018 Commercial Lighting Retrofit Rebate Program

General Kitchen, Bath & Bedroom Remodeling Notes County of Marin, Building Inspection Division

Energy Codes. Connected Lighting simplified by Eaton. design and application guide

ULTRA RT6 and RT6 Gimbal LED Recessed Downlight Kit

REPORT 545 E. Algonquin Rd., Arlington Heights, IL 60005

LED retrofits! 4 T8 Specification Guide. Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! Pure Bright

Richmond Building Energy Challenge. Project List - Lighting Technologies

Public Hearing, July 12, 2018

NEMA Standards Publication Temporal Light Artifacts: Test Methods and Guidance for Acceptance Criteria

GI/GN7520. Guidance on Lighting of Railway Premises. Railway Group Guidance Note

Dimming Ballast + Controls and CALCTP Bonus. New Product Overview

2. Measurements are to be made at ground level, with the light-sensor portion of the meter lying flat on the ground, pointing upward.

AVAILABLE THROUGH GRAINGER. LED Fixtures

SECTION LIGHTING

2005 Title 24 Outdoor Lighting Regulations Overview. 77 slides

Article 14. LIGHTING REGULATIONS

CA TITLE 24 QUICK SOLUTIONS GUIDE FOR

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight

VISAGE ENVIRONMENTAL LIGHTING SOLUTION. INDOOR Lighting SERIES

Lighting Controls An Introduction and Review

Transcription:

2019 TITLE 24, PART 6 RESIDENTIAL LIGHTING Best practices in lighting design to comply with NICOLE GRAEBER HATHAWAY Senior Development Engineer

2 DISCLAIMER THIS PRESENTATION IS PROTECTED BY U.S. AND INTERNATIONAL COPYRIGHT LAWS. REPRODUCTION, DISTRIBUTION, DISPLAY AND USE OF THE PRESENTATION WITHOUT WRITTEN PERMISSION OF THE SPEAKER IS PROHIBITED. THE INFORMATION IN THIS DOCUMENT IS BELIEVED TO ACCURATELY DESCRIBE THE TECHNOLOGIES ADDRESSED HEREIN AND IS MEANT TO CLARIFY AND ILLUSTRATE TYPICAL SITUATIONS, WHICH MUST BE APPROPRIATELY ADAPTED TO INDIVIDUAL CIRCUMSTANCES. THESE MATERIALS WERE PREPARED TO BE USED IN CONJUNCTION WITH A FREE EDUCATIONAL PROGRAM AND ARE NOT INTENDED TO PROVIDE LEGAL ADVICE OR ESTABLISH LEGAL STANDARDS OF REASONABLE BEHAVIOR. NEITHER PACIFIC GAS & ELECTRIC (PG&E), SOUTHERN CALIFORNIA EDISON (SCE) NOR ANY OF ITS EMPLOYEES AND AGENTS: (1) MAKES ANY WRITTEN OR ORAL WARRANTY, EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE; (2) ASSUMES ANY LEGAL LIABILITY OR RESPONSIBILITY FOR THE ACCURACY OR COMPLETENESS OF ANY INFORMATION, APPARATUS, PRODUCT, PROCESS, METHOD, OR POLICY CONTAINED HEREIN; OR (3) REPRESENTS THAT ITS USE WOULD NOT INFRINGE ANY PRIVATELY OWNED RIGHTS, INCLUDING BUT NOT LIMITED TO PATENTS, TRADEMARKS OR COPYRIGHTS. FURTHERMORE, THE INFORMATION, STATEMENTS, REPRESENTATIONS, GRAPHS AND DATA PRESENTED IN THIS REPORT ARE PROVIDED BY PG&E AND SCE AS A SERVICE TO OUR CUSTOMERS. PG&E AND SCE DO NOT ENDORSE PRODUCTS OR MANUFACTURERS. MENTION OF ANY PARTICULAR PRODUCT OR MANUFACTURER IN THIS COURSE MATERIAL SHOULD NOT BE CONSTRUED AS AN IMPLIED ENDORSEMENT.

3 LEARNING OBJECTIVES Effectively apply the mandatory residential Title 24 Building Energy Efficiency Standards Requirements specific to lighting Understand the lighting-related requirements in the 2019 Title 24 Building Energy Efficiency Standards code Identify current lighting technologies, including LED luminaires, that are available to fulfill code requirements Access resources through utility and lighting technology training centers for continued professional development Understand how to participate in the 2022 Title 24 Building Energy Efficiency Standards code and standards enhancement process.

4 CALIFORNIA LIGHTING TECHNOLOGY CENTER, UC DAVIS To stimulate, facilitate and accelerate the development, application and commercialization of energy-efficient lighting and daylighting technologies in partnership with utilities, manufacturers, occupants, builders, designers, researchers, academicians and government agencies. Mission-driven Activities: Research & Development Demonstration & Outreach Education & Training

5 FOUNDING ORGANIZATIONS UTILITIES LARGE END-USERS MANUFACTURERS

6 Provides updates to mandatory lighting Energy Efficiency Standards. There are major changes in: Color quality Marking update New light source categories added Available online for download! cltc.ucdavis.edu

7 2016 RESIDENTIAL LIGHTING DESIGN GUIDE Provides a simplified and practical approach to lighting code compliance and design. Topics include: Explanation of the code Technical guidelines Steps to compliance Lighting Design examples Available online for download: www.cltc.ucdavis.edu Printed copies available here: https://www.amazon.com/dp/1977708765

8 2019 RESIDENTIAL LIGHTING DESIGN GUIDE Provides a simplified and practical approach to lighting code compliance and design. Topics include: Explanation of the code Technical guidelines Steps to compliance Lighting Design examples Available soon for download! cltc.ucdavis.edu

10 BACKGROUND & POLICY

11 WHY TITLE 24, PART 6? EFFICIENCY BEFORE GENERATION The California Energy Commission has found energy efficiency and demand response as the preferred means of meeting the energy needs of a growing population.

14 WARREN-ALQUIST ACT STANDARD DEVELOPMENT OBLIGATIONS Technically feasible Cost-effective Performance-based and prescriptive compliance path

15 Focus Area Goal Now 2020 2025 2030 2050 Residential Buildings Commercial Buildings State Buildings New Construction ZNE 1 100% Existing Homes (reduction relative existing stock) 1 40% New Construction ZNE 1 100% Existing ZNE 1 50% New Construction & Major Retrofit ZNE 2 50% 100% Existing ZNE (by square footage) 2 50% SB 350 Increase energy efficiency in existing buildings 50% Existing Buildings New and enhanced codes & standards, code simplification, increased compliance, asset X X X X ratings, purchase agreements, etc. 3 GHG Emissions Statewide GHG Emissions (all sources) 4 1990 Levels 40% Below 1990 80% Below 1990 Water Efficiency 25 percent reduction in urban water use 5 X 1. Strategic Plan 2. Executive Order B-18-12 3. Assembly Bill 758; Existing Buildings Action Plan 4. Assembly Bill 32 for 2020; Executive Order B-30-15 for 2030 and 2050 5. Executive Order B-29-15

16 TITLE 24 CODE CYCLE TIMELINE The most recent revision, the 2019 Title 24 Building Energy Efficiency Standards, will be effective soon! Any application for a Building Permit submitted on or after January 1, 2020 must meet the 2019 standards. The 2022 Title 24 Building Energy Efficiency Standards are currently being researched and developed. If you are interested in following the Codes and Standards Enhancement (CASE) process please participate in public events and docketing of comments on the California http://www.energy.ca.gov/title24/2022standards/ http://title24stakeholders.com/ https://caenergyalliance.org/2022-title-24/ Note: This presentation is not intended to be used in lieu of the Title 24 Building Energy Efficiency Standards. Please visit www.energy.ca.gov/title24 to download the official Title 24 Building Energy Efficiency Standards as well as the Nonresidential Compliance Manual.

19 COMPLIANCE REQUIREMENTS

20 DOES MY PROJECT TRIGGER CODE? 1 2 3 NEW CONSTRUCTION New construction refers to construction of entirely new structures. New residential construction must comply with the mandatory lighting measures contained in 150.0(k) and Table 150.0-A. ADDITIONS Additions are any change that increases the floor area and volume of a building of an occupancy group or type regulated by the Energy Standards. Additions are also any change that increases the illuminated area of an outdoor lighting application regulated by the Standards. New residential additions must comply with the mandatory lighting measures contained in 150.0(k) and Table 150.0-A. ALTERATIONS Alterations involve replacing any lighting component, system, or equipment regulated by the Standards. Alterations to existing residential lighting systems must comply with the mandatory lighting measures contained in 150.0(k) and Table 150.0-A.

21 THE COMPLIANCE PROCESS 1 2 3 DESIGN Architects, engineers and designers must understand both the requirements and the underlying intent of the standards if they are to design buildings and systems that are inherently energy efficient and cost effective. PERMIT APPLICATION Design teams must make sure that the plans contain all the information that the building official will need to verify that the building or system satisfies the requirements. PLAN CHECK The plans examiner of the local building department must verify that the building or system satisfies the requirements of the standards and that the plans (not just the compliance forms) contain the information to be verified during field inspection.

22 THE COMPLIANCE PROCESS 4 5 6 CONSTRUCTION Contractors must carefully follow the approved plans and specifications, and the building department field inspector(s) must verify that the building is constructed according to the plans and specifications. ACCEPTANCE COMMISSIONING After completion of construction, the contractor and/or the design team must properly commission the building and its systems and provide information and/or training to the building operators on maintenance and operation of the building and its equipment. OPERATION After occupancy, the building and its systems must be correctly operated and properly maintained. The building must provide new homeowners with a luminaire schedule that includes a list of installed lamps and luminaires. This ensures that homeowners know what lighting products they are entitled to when they take possession of a new home.

23 LOCALLY ADOPTED ENERGY STANDARDS Local governmental agencies, primarily cities and counties, may adopt and enforce standards for newly constructed and existing buildings that are more stringent than Title 24. These can include: Shorter timeframes Additional energy conservation measures More stringent energy budgets CALGreen or GreenPoint Rated It is critical to check with your local building agency for additional requirements. A list of all local ordinances exceeding the 2016 standards is located at: http://www.energy.ca.gov/title24/2016standards/ordinances/ The 2019 list will be available soon!

24 PRESCRIPTIVE VS. PERFORMANCE STANDARDS PRESCRIPTIVE STANDARDS Simpler, but does not allow as much flexibility in design Each individual component of the proposed building must meet a prescribed minimum energy requirement Applicant needs only to show that a building meets each minimum or maximum level prescribed in the set of requirements contained in a package PERFORMANCE STANDARDS Allows the builder more freedom, but the standards are more complex and involved Detailed accounting of energy trade-offs between measures is possible Uses Energy Commissionapproved computer software to calculate energy trade-offs based on Title 24 guidelines piece together the building I want while complying with Title 24?

25 2019 APPROVED COMPLIANCE PROGRAMS The following 2019 compliance software research versions currently are only available for testing and is strictly for non-compliance use only; only approved 2016 compliance software is valid for compliance. www.energy.ca.gov/title24/2019standards/2019_computer_prog_list.html

26 2016 APPROVED COMPLIANCE PROGRAMS http://www.energy.ca.gov/title24/2016standards/2016_computer_prog_list.html

27 MANDATORY MEASURES Mandatory measures required by both prescriptive and performance approaches include the following areas: Building envelope Space conditioning, water heating and plumbing Ducts and fans Pools and spas Fireplaces Lighting

28 WHAT FORMS APPLY? CF2R-LTG-01-E for single-family dwellings CF2R-LTG-02-E for multi-family dwellings DOWNLOAD FORMS HERE: http://www.energy.ca.gov/title24/ 2019standards/residential_manu al.html The appropriate CF2R form must be posted on site and provided to the home owner once the lighting project has been completed.

29

30

31

32

33

34 MODERNIZED APPLIANCE EFFICIENCY DATABASE SYSTEM (MAEDBS) http://www.appliances.energy.ca.gov/advancedsearch.aspx The 2019 JA8 list will be available soon!

35 CONSTRUCTION & INSPECTION Starting 2016 code cycle, the builder must provide new homeowners with a luminaire schedule that includes a list of installed lamps and luminaires. Lighting inspections are made easier since all luminaires are high efficacy and there is a completed luminaire schedule for the owner. In the 2016 and 2019 code: 10-103(b) 2

Photo: CLTC, UC Davis

37 CONCEPTS & PRINCIPLES Photo: CLTC, UC Davis

38 LIGHTING & ENERGY EFFICIENCY Light Sources One-time, long-term change Reduction of baseline Light Source Efficacy Luminaire Efficacy Application Efficacy Light Controls Continuous, real-time change Fluctuations from baseline Dimming Occupancy / Vacancy

39 Select the Appropriate SOURCE + LUMINAIRE + CONTROLS (for the application)

40 ELECTROMAGNETIC RADIATION

41 SPECTRAL POWER DISTRIBUTION SPD: The radiant power emitted by a light source over a range of specified wavelengths, typically the visible range (approximately 360 nm to 830 nm) spectral power distribution (SPD) Why does this matter?

42 INTEGRATING SPHERE

43 TERMINOLOGY Luminous flux: rate of flow of visible light emitted from a light source over time, measured in lumens (lm). luminous intensity of the measured solid angle (lm), where: 1 lumen = 1 candela * 1 steradian Illuminance: the amount of luminous flux that covers a surface (measured in lux or footcandles). Footcandle: equal to one lumen per square foot (1 footcandle = 10 lux).

44 LUMINOUS FLUX (LUMEN) Total amount of light emitted Measured in all directions Unit is lumen (lm) Used to quantify the output of lamps Luminous Flux Measured in Lumens (lm)

45 GONIOPHOTOMETER

46 LUMINOUS INTENSITY (CANDELA)

47 LUMINOUS INTENSITY (CANDELA) Intensity of light emitted in a specific direction Unit is candela (cd) Used to rate the output of directional lamps and light distribution of luminaires The luminous intensity of a source expressed in candelas is called its candlepower (cp) Photo Credit: PG&E Pacific Energy Center 2016

48 TERMINOLOGY Luminous Intensity: the concentration of light emitted from a given source in a particular direction, measured in candela (cd) (1 cd = 1 lm per steradian). LED MR16 4 Watts 12 Volts Beam Angle: 25 CBCP: 760 cd Brightness: 190 lm LED MR16 4 Watts 12 Volts Beam Angle: 15 CBCP: 1550 cd Brightness: 190 lm *Note: color represents intensity, not CCT or CRI

49 LUMINANCE (CANDELA PER METER 2 ) Light emitted, reflected, or transmitted from or through a surface Specific to the direction of travel of the light US Unit is candela per square foot SI Unit is candela per square meter

50 ILLUMINANCE (FOOTCANDLE OR LUX) Density of light incident on a surface Surface can be real or imaginary A plane or a point in space US Unit is footcandle (fc) One Lumen per one square foot SI Unit is lux (lx) One lumen per one square meter Horizontal and/or vertical levels may be critical depending on the application and type of task 10.76 lux = 1 foot-candle, ~10 lux = 1 foot-candle

51 IES ILLUMINANCE RECOMMENDATIONS Category A (3fc) B (5fc) C (10fc) D (30fc) E (50fc) F (100fc) G (800fc) Building Types Public spaces (Movie theater, observatory) Orientation for short visits (Public auditorium, night club, arcade) Working spaces for simple visual tasks (Art gallery, restaurant, parking garage, public restroom) Performance of visual tasks of high contrast and large size (Coliseum/arena, school gymnasium, chapel, grocery store, commercial building) Performance of visual tasks of high contrast and small size or tasks of low contrast and large size (School, medical laboratory, computer processing office, vehicle repair center) Performance of visual tasks of low contrast and small size (Hospital facilities, veterinary clinic) Performance of visual tasks near threshold (Operating table)

52 ELECTRICAL CHARACTERISTICS Efficiency: the ratio between the useful output of energy and the input of energy. Luminous Efficacy compares the amount of light produced by a lamp (lumens), to amount of power consumed to produce it (watts).

53 CORRELATED COLOR TEMPERATURE (CCT) A specification of the color appearance of light emitted by a lamp, relating its color to the color of light from a source when heated to a particular temperature.

54 CORRELATED COLOR TEMPERATURE (CCT)

55 COLOR RENDERING INDEX of an illuminant on the color appearance of objects by conscious or subconscious comparison with their color appearance under a R1 R2 R9 R10 1987) It is the only color rendering metric with wide spread acceptance It is calculated by comparing the color appearance of the test source to a reference source for 8 reflective samples (Score from 1 100) All other aspects of the source for a true comparison should be the same R3 R5 R7 R4 R6 R8 R11 R12 R13 R14

56 COLOR RENDERING INDEX

57 LIGHTING FACTS LABEL

59 TECHNOLOGY REQUIREMENTS

CONTROLS SOURCES 60 TWO STRATEGIES, THREE MAIN TECHNOLOGIES HIGH EFFICACY LIGHT SOURCES These light sources are designed and built to operate only high-efficacy light sources, as defined by the California Energy Commission. Select sources are automatically considered high-efficacy, while others must meet criteria. SENSORS Occupancy/vacancy sensors and daylight sensors are all devices that automatically turn lights off (or dim them) in response DIMMERS Dimmers, which are already common in many residential applications, allow room occupants to lower lighting levels (and thus energy use) as desired.

61 MODERNIZED APPLIANCE EFFICIENCY DATABASE SYSTEM (MAEDBS) http://www.appliances.energy.ca.gov/advancedsearch.aspx The 2019 JA8 list will be available soon!

63 LIGHT SOURCES

64 2019 LUMINAIRE REQUIREMENTS Luminaire Efficacy Blank Electrical Boxes Recessed Downlight Luminaires Electronic Ballasts Night Lights Lighting Integral to Exhaust Fans Screw Based Luminaires Enclosed Luminaires In the 2016 code: 150(k)1

65 2019 HIGH EFFICACY LIGHTING In the 2019 code: 150(k)1 A

66 2019 HIGH EFFICACY LIGHTING Light Sources that are always considered - 1. Pin-based linear or compact fluorescent light sources paired with electronic ballasts 2. Pulse-start metal halide 3. High pressure sodium 4. Luminaires with hardwired high frequency generator and induction lamp 5. LED light sources installed outdoors 6. Inseparable SSL luminaires containing colored light sources that are installed to provide decorative lighting In the 2019 code: 150(k)1 A

67 2016 HIGH EFFICACY LIGHTING In the 2016 code: 150(k)1 A

68 2016 HIGH EFFICACY LIGHTING Light Sources that are always considered - 1. Pin-based linear or compact fluorescent light sources paired with electronic ballasts 2. Pulse-start metal halide 3. High pressure sodium 4. GU-24 sockets containing light sources other than LED (CFL, induction, etc.) Title 20 does not permit incandescent GU-24 lamps 5. Luminaires with hardwired highfrequency generator and induction lamp 6. Inseparable solid state lighting luminaires that are installed outdoors 7. Inseparable solid state lighting luminaires containing colored light sources that are installed to provide decorative lighting In the 2016 code: 150(k)1 A

69 2019 HIGH EFFICACY LIGHTING In the 2019 code: 150(k)1 A

Photo: Designer s Fountain Photo: Juno Lighting Photo: Frederick Ramond 70 2019 HIGH EFFICACY LIGHTING Light Sources that are considered - they comply with JA8 requirements: 1. All light sources in ceiling recessed downlight luminaires. Note that ceiling recessed downlight luminaires shall not have screw-bases regardless of lamp type 2. Any light source not otherwise listed in Table 150.0-A and certified to the Commission as complying with JA8 In the 2019 code: 150(k)1 A

71 2016 HIGH EFFICACY LIGHTING In the 2016 code: 150(k)1 A

Photo: Designer s Fountain Photo: Frederick Ramond Photo: Feit Electric Photo: Juno Lighting 72 2016 HIGH EFFICACY LIGHTING Light Sources that are considered - they comply with JA8 requirements: 1. All light sources in ceiling recessed downlight luminaires. Note that ceiling recessed downlight luminaires shall not have screw-bases regardless of lamp type 2. GU-24 sockets containing LED light sources 3. Any light source not otherwise listed in Table 150.0-A and certified to the Commission as complying with JA8 In the 2016 code: 150(k)1 A

73 2019 HIGH EFFICACY LIGHTING JA8 High efficacy products include any luminaire that contains a JA8- compliant lamp or other approved light source (Section 150.0(k) and Joint Appendix JA8) Manufacturers must test their products at an accredited test laboratory and submit the results to the California Energy Commission to gain JA8 certification Must be certified and marked as either JA8-2019 or JA8-2019-E Compliant products may be found at http://www.appliances.energy.ca.gov/ AdvancedSearch.aspx Appendix JA8: Qualification Requirements for High Efficacy Light Sources Partial List Specification Initial Efficacy Power Factor at Full Rated Power Correlated Color Temperature (CCT) Color Rendering Index (CRI) R1 8; R9 Rated Life Minimum Dimming Level Requirement general service LED lamps, the efficacy must be 68 lumens/watts or greater) R1 for all else In the 2019 code: 150(k)1 A Flicker < 30% for frequencies of 200 Hz or below, at 100% and 205 light output

74 2016 HIGH EFFICACY LIGHTING JA8 High efficacy products include any luminaire that contains a JA8- compliant lamp or other approved light source (Section 150.0(k) and Joint Appendix JA8) Manufacturers must test their products at an accredited test laboratory and submit the results to the California Energy Commission to gain JA8 certification Must be certified and marked as either JA8-2016 or JA8-2016-E Compliant products may be found at http://www.appliances.energy.ca.gov/ AdvancedSearch.aspx In the 2016 code: 150(k)1 A

75 2019 VS. 2016 HIGH EFFICACY LIGHTING JA8 Appendix JA8: Qualification Requirements for High Efficacy Light Sources Partial List Specification Initial Efficacy Requirement Meet Title 20 requirements for general service LED lamps, or be at least 45 lumens/watt. Title 20 requires general service LED lamps to be at least 68 lumens/watt Power Factor at Full Rated Power Correlated Color Temperature (CCT) Color Rendering Index (CRI) R1 8; R9 90 for all else R1 Rated Life Minimum Dimming Level < 30% for frequencies of 200 Hz or Flicker In the 2016 code: 150(k)1 below, A at 100% and 205 light output

76 BLANK ELECTRICAL BOXES APPLIES TO THE ENTIRE RESIDENCE: mean? Electrical box that does not contain a luminaire or other device AND Higher than 5 feet above the finished floor Number of blank electrical boxes shall be no greater than the number of bedrooms in the residence. How many blank electrical boxes is this residence allowed? 3 Bedrooms = Up to 3 blank electrical boxes! 2 1 3 Additionally: Blank electrical boxes must be controlled by dimmer, vacancy sensor control, or fan speed control. In the 2019 code: 150(k)1 B

Photo: Cree 77 RECESSED DOWNLIGHT LUMINAIRES IN CEILINGS MUST BE: Approved for insulation contact (IC) by UL or equivalent laboratory Labeled certifying airtight (AT) according to ASTM E283 Air leakage is <2.0 CFM at 75 Pascals Does not apply to exhaust fans! Sealed with gasket or caulking between housing and ceiling all air leak paths through luminaire assembly or ceiling opening must be sealed! For luminaires with hardwired ballasts/drivers, allow for readily accessible maintenance from below ceiling without cutting holes. NO SCREW BASES (E26) Only paired with JA8 compliant light sources marked JA8-2019-E E means it was tested and approved for elevated temperatures In the 2019 code: 150(k)1 C

78 2019 ALTERATIONS OF RECESSED DOWNLIGHT LUMINAIRES IN CEILINGS For alterations, clarifying language has been added addressing existing screw-base sockets. If a screw-base socket is present in a ceiling-recessed luminaire, it does not have to be removed as part of the alteration. Instead, if the socket is kept, the alteration must use a JA8 compliant light source. In the 2019 code: 150.2(b)F ii J

79 ELECTRONIC BALLASTS Certified to the Energy Commission Mandated for fluorescent lamps rated 13 Watts or greater Output frequency no less than 20 khz In the 2019 code: 150(k)1 D

80 NIGHT LIGHTS HIGH EFFICACY LIGHT SOURCE Permanently installed night lights Night lights integral to installed luminaires or exhaust fans SHALL BE: 5 Watts or less NO CONTROLS REQUIRED: Not required to be controlled by vacancy sensor In the 2019 code: 150(k)1 E

81 STEP LIGHTS & PATH LIGHTS Step lights and path lights are now regulated under the Energy Standards. They are included in the same category as night lights. These light source types must adhere to the 2019 high-efficacy performance and control requirements defined in Table 150.0-A if they are: Greater than 5 Watts, or Emit more than 150 lumens. Otherwise, the light source is exempt. In the 2019 code: 150(k)1 E New in 2019!

Photo: Broan 82 LIGHTING INTEGRAL TO EXHAUST FANS Required to meet all applicable residential lighting requirements Exception: Lighting installed by the manufacturer in kitchen exhaust hoods Photo: Home Depot In the 2019 code: 150(k)1 F

Photo: Fredrick Ramond 83 SCREW BASED LUMINAIRES APPLICABLE TO: Any screw base luminaires MUST: Not be recessed downlight luminaires in ceilings Contain lamps that comply with JA8 Contain lamps that are marked with JA8-2019 or JA8-2019-E JA8-2019 lamps are appropriate for open fixtures JA8-2019-E lamps are appropriate for fixtures that experience elevated temperatures, i.e. enclosed EXCEPTION: Luminaires with hard-wired ballasts for high intensity discharge (HID) In the 2019 code: 150(k)1 G

Photo: Amazon Photo: Capital Photo: Kichler 84 ENCLOSED LUMINAIRES Light sources not marked with JA8-2019-E shall not be installed in enclosed luminaires Enclosed luminaires are luminaires which contain enclosed lamp compartments where ventilation openings are less than 3 square inches per lamp in the lamp compartment as defined by UL 1598 What are some examples of enclosed luminaires? In the 2019 code: 150(k)1 H

85 LIGHT SOURCES IN DRAWERS, CABINETS AND LINEN CLOSETS Light sources internal to drawers, cabinetry or linen closets shall not be required to comply with Table 150.0-A or be controlled by vacancy sensors provided that: They are rated to consume no more than 5 watts of power Emit no more than 150 lumens Are equipped with controls that automatically turn the lighting off when the drawer, cabinet or linen closet is closed. In the 2019 code: 150(k)1 I New in 2019!

Photo: Tech Lighting

87 INTERIOR CONTROLS Photo: Tech Lighting

88 DIMMER AND VACANCY SENSOR REQUIREMENTS Dimmers OR vacancy sensors are required to control all JA8 compliant light sources. EXCEPTIONS: Luminaires in closets less than 70 square feet Luminaires in hallways ADDITIONALLY: In bathrooms, garages, laundry rooms, and utility rooms at least one luminaire must be controlled by a vacancy sensor. In the 2019 code: see 150(k)2 J and I

Photo: Broan 89 EXHAUST FANS Exhaust fans shall be switched separately from lighting system Exception: Lighting can be on the same switch as long as the fan stays on for an extended period of time after light is switched off. In the 2019 code: 150(k)2 B

Photo: Hunter 90 INTERIOR SWITCHING DEVICES & CONTROLS Clarifying language has been added for 2019 interior lighting switching devices and controls. All light sources must have readily accessible, wall-mounted controls except for ceiling fans with integrated lighting, which can be controlled by a remote control. In the 2019 code: 150(k)2 K

91 UNDERCABINET LIGHTING Undercabinet lighting shall be controlled separately from ceiling-installed lighting such that one can be turned on without turning on the other In the 2019 code: 150(k)2 K

92 UNDERCABINET LIGHTING Undercabinet lighting shall be switched separately from lighting system In the 2016 code: 150(k)2 L

93 INDOOR VACANCY SENSOR REQUIREMENTS REQUIREMENTS Must be manual-on/automatic-off (can also be turned off manually) Time delay cannot be greater than 20 minutes automatically Provide a visible status signal indicating that the device operates properly, or that it has failed Cannot be locked in a permanent OPTIONAL FEATURES TO CONSIDER Energy-efficiency LED night-light Impact-resistant lens and switch Vacancy Sensors (top to bottom): WattStopper CS-50 PIR Wall Switch Vacancy Sensor; Lutron Maestro occupancy / vacancy sensor; WattStopper CS-350-N PIR Dual Relay Wall Switch Vacancy Sensor In the 2019 Title 24 code: 110.9(b) 4 F; In Title 20: 1605.3(l)(G) 8

Photo: Lutron 94 SWITCHING DEVICES AND CONTROL REQUIREMENTS Controls shall be readily accessible Shall have the capability of manually switching lighting ON and OFF All forward phase dimmers used with LED light sources must comply with NEMA SSL 7A* Shall be installed according to Shall not bypass any dimmer or vacancy sensor functionality installed to comply with 150(k)2 requirements Energy Management Control Systems (EMCS) can be used to comply with 150(k)2 requirements assuming it provides the same functionality and is certified *NEMA SSL 7A is an industry standard that provides compatibility requirements for dimmers and LED light sources In the 2019 Title 24 code: 150(k)2 A, 150(k)2 C, 150(k)2 D, 150k(2) F, 150(k)2 G, 150(k)2 H

Photo: Lutron 95 DIMMER REQUIREMENTS Comply with Title 20 Very subtle differences in language The dimmer shall: Reduce power consumption by a minimum of 65 percent at its lowest level Include an off position which produces a zero lumen output; and not consume more than 1 W per lighting dimmer switch leg when in the off position Reduce flicker through dimming range to be no greater than 30 percent flicker For 3-way, do not override level set by dimmer and all switches should turn light off In the 2019 code: 110.9(b) 3; In Title 20: 1605.3(f)

Photo: Lutron 96 DIMMER SPECIFICATIONS RECOMMENDATIONS SPECIFY THE CORRECT LOAD AMOUNT: Line voltage Low voltage 3-way dimmers (ex. hallway applications) Pair LED luminaires and lamps carefully with dimmers, check manufacturer websites and spec sheets for compatibility. In the 2019 code: 150(k) 2D

97 CONTROL REQUIREMENTS BY SPACE

98 OVERVIEW OF INTERIOR LIGHTING REQUIREMENTS

99 EXERCISE YOUR INDOOR LIGHTING KNOWLEDGE! Is this design compliant? 1. All high efficacy? 2. Manual on/off controls? 3. If JA8 listed, is it controlled by a dimmer or vacancy sensor? 4. Undercabinet lighting switched separately?

101 OUTDOOR LIGHTING

102 OUTDOOR LIGHT SOURCE REQUIREMENTS Must meet the requirements in Table 150.0-A In the 2019 code: 150(k) 3

Photo: Tork 103 OUTDOOR CONTROL REQUIREMENTS Lighting for single family homes and lighting mounted to any building on the lot must be controlled by: Manual ON / OFF switch and paired with one of the following combinations: 1. Photocell and motion sensor 2. Photocell and automatic time switch controls 3. Astronomical time clock 4. EMCS with features: 1. Astronomical time clock, 2. Does not allow the luminaire to be ON during the day, and 3. May be programmed to automatically turn lighting OFF at night Photo: RAB Electric Lighting In the 2019 code: 150(k) 3 A

104 EXERCISE YOUR OUTDOOR LIGHTING KNOWLEDGE! Is this design compliant? 1. All high efficacy? 2. Manual on/off controls? 3. Does it meet one of the following control strategy requirements? 1. Photocell/motion sensor, 2. Automatic time switch, or 3. Astronomical time clock

106 INTERNALLY ILLUMINATED ADDRESS SIGNS

107 INTERNALLY ILLUMINATED ADDRESS SIGNS Consume no more than 5 watts of power OR Comply with the nonresidential sign lighting Standards in 140.8: Cannot exceed 12 watts per sq. ft. internal illumination Cannot exceed 2.3 watts per sq. ft. external illumination In the 2019 code: 150(k) 4

108 INTERNALLY ILLUMINATED ADDRESS SIGNS Alternatives when equipped only with one or more of the light sources: High-pressure sodium Select metal halide lamps Select neon or cold cathode lamps Fluorescent lamps with a minimum 80 CRI OR paired with electronic ballasts Compact fluorescent lamps with not screw-base sockets LEDs In the 2019 code: 150(k) 4

Photo: CLTC, UC Davis

110 RESIDENTIAL GARAGES AND PARKING LOTS Photo: CLTC, UC Davis

111 PARKING LOTS AND GARAGES RESIDENTIAL LOTS AND GARAGES Residential standards apply to parking lots, carports and parking garages (attached and detached from dwelling unit) for seven or fewer vehicles per site Parking lots and carports must meet the residential outdoor lighting requirements or the non-res requirements Parking garages must meet the residential indoor lighting requirements: High efficacy and Controlled by a vacancy sensor In the 2019 code: 150(k) 5 NON-RESIDENTIAL LOTS AND GARAGES Non-residential standards apply to parking lots, carports and parking garages (attached and detached from dwelling unit) for eight or more vehicles Must meet the power density limits for non-residential lighting standards Luminaires must be controlled by a photocontrol or time switch that turns lights off when daylight is present New construction or major alterations are required to comply with Backlight, Uplight, Glare ratings per IES TM-15-11 Pole mounted luminaire > 40W and < 24 ft must include motion sensors that reduce lighting levels on vacancy. Other conditions apply, see sections: 110.9, 130.0, 130.2, 130.4, 140.7 & 141.0

2019 TITLE 24, PART 6 NONRESIDENTIAL LIGHTING LIGHTING 113 MULTI-FAMILY RESIDENTIAL BUILDINGS

114 LOW-RISE MULTI-FAMILY COMMON AREAS A multi-family complex consists of four or more dwelling units. A low-rise is considered a building with three or fewer stories. If the building has more than three stories the common areas must comply with the nonresidential code. In the 2019 code: see 150(k) 6

115 LOW-RISE MULTI-FAMILY COMMON AREAS In buildings where common areas constitute > 20% of the floor space: Lighting must comply with the non-residential standards Lighting in corridors and stairwells must be controlled by occupancy sensors that reduce lighting power by at least 50% In buildings with common areas that All hardwired lighting must comply with Table 150.9-A or controlled by an occupancy sensor In the 2019 code: see 150(k) 6

116 MULTI-FAMILY OUTDOOR CONTROL REQUIREMENTS Low-rise multifamily residential buildings, outdoor for private patios, balconies, entrances, and porches must meet these requirements: Manual ON / OFF switch paired with one of the following combinations: 1. Photocell and motion sensor 2. Photocell and time switch 3. Astronomical time clock 4. EMCS with features of astronomical time clock, does not allow the luminaire to be ON during the day, and may be programmed to automatically turn lighting OFF at night In the 2019 code: see 150(k) 3C

117 MULTI-FAMILY OUTDOOR CONTROL REQUIREMENTS Carports, parking garages and parking lots with eight or more spaces must comply with nonresidential standards. Smaller parking areas may comply with either the residential or nonresidential standards. In the 2019 code: see 150(k) 3C

119 RESOURCES

120 WWW.ENERGY.CA.GOV/TITLE24/2019STANDARDS

121 WWW.ENERGY.CA.GOV/TITLE24/2016STANDARDS

122 CEC ONLINE RESOURCE CENTER

123 WWW.ENERGY.CA.GOV/EFFICIENCY/BLUEPRINT

124 WWW.ENERGYCODEACE.COM

125 ENERGYCODEACE.COM/RESOURCES

126 WWW.CLTC.UCDAVIS.EDU

127 The California Energy Commission provides contacts for energy efficiency programs related to the Energy Standards:

2019 TITLE 24, PART 6 THANK YOU! For more information and resources about Title 24, Part 6: cltc.ucdavis.edu/title24 NICOLE GRAEBER HATHAWAY Senior Development Engineer negraeber@ucdavis.edu