Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Similar documents
Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100U4PSBA TAG:

Downflow/Horizontal Right Induced Draft Gas Furnace

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

Upflow/Horizontal Condensing, Gas-Fired Furnace

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080D3PSBA TAG:

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 60,000 BTUH S9V2B060D3PSBA TAG:

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

Split System Cooling Product & Performance Data

Product Data. Split System Cooling A. November 2013

Downflow/Horizontal Right or Downflow/Horizontal Left Induced Draft Gas Furnace

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Split System Heat Pump Product Data

Split System Cooling Product Data

Upflow/ Horizontal Left/Right, Downflow Two Stage Condensing Gas Fired Furnace

Split System Heat Pump Product Data

Split System Heat Pump Product Data

SPLIT SYSTEM HEAT PUMP 2, 3, 4 & 5 ton HERITAGE 20 MODELS 4A6Z0024, 036, 048, & 060A. with AccuLink and Charge Assist

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XB 80 TDD-D-1 PUB. NO

Split System Cooling Product Data

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Product Data. Split System Heat Pump D-EN. February 2016

Product Data. Split System Cooling H-EN. January 2017

Split System Heat Pump Product Data

Split System Heat Pump Product Data

AMERICAN STANDARD 14 MODELS 4A7B E

Product Data. Split System Heat Pump B-EN. February A6H6024H1000A

Split System Heat Pump Product Data

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

Split System Cooling Product Data

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

4YCC3048A3096A /3/ /

Product Data. Split System Heat Pump A-EN. March 2016

Split System Cooling Product Data

Split System Cooling Product Data

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A

Split System Cooling Product Data

Split System Cooling Product Data

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

Split System Cooling Product Data

13 GEP A L P - 1 A

Product Data. Split System Cooling D-EN. August 2016

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

Split System Cooling Product Data

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Split System Cooling Product Data

Split System Cooling Product Data

Product Data. Split System Cooling E-EN. November 2016

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

Split System Heat Pump Product & Performance Data

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

Split System Cooling Product Data

36,000-62,000 BTUH Nominal Capacity

RGE 13 A T - 1 A

Product Data Split System Cooling

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Upflow/ Downflow Horizontal Right or Left Gas-Fired Furnace

Product Data YCZ6036A through 4YCZ6060A Single Packaged Convertible Gas/Electric 16 SEER 3, 4 & 5 Ton, MBTU R-410A

Vertical Upflow Horizontal Left Air Handlers

Cooling/Heat Pump Convertible Air Handlers

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

Cooling/Heat Pump Convertible Air Handlers

Product Data. Side Discharge AC Models 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

Split System Cooling Product & Performance Data

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

Modular Multi-position Air Handler

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

Cooling/Heat Pump Convertible Air Handlers

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Variable Speed Convertible Air Handler 5 Ton

MACH N-407 Heat Pump Air-Cooled Chiller

Product Data DCZ6036A through 4DCZ6060A Single Packaged Convertible Dual Fuel 16 SEER 3, 4 & 5 Ton, MBTU R-410A

Product Data. Split System Heat Pump 4TWR4018G1000A 4TWR4024G1000A 4TWR4030G1000A 4TWR4036G1000A 4TWR4042G1000A 4TWR4048G1000A 4TWR4060G1000A

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

2 shp 13 lc 1 36 t - 1 a

Variable Speed Convertible Air Handler 4 Ton

Product Data. Split System Heat Pump

MAC N-407 Air-Cooled Chiller

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

X341119P10 Gas Furnace Var. Speed Blower Var. Speed Inducer Two Stage Heat Direct Vent Models:

HIGH EFFICIENCY AIR HANDLER

Transcription:

Submittal Prepared For: All Bidders Sold To: Date: January 8, 209 Customer P.O. Customer Project Job Job Name: City of Carrollton Fire Splits 623 Beltline Road CARROLLTON, TX 75006 Trane U.S. Inc. dba Trane is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 4 Split System Air Conditioning Units (Small) The attached information describes the equipment we propose to furnish for this project, and is submitted for your approval. Scott Sherbit Trane 67 HUTTON DRIVE Carrollton, TX 750068336 Phone: (469) 7583077 Product performance and submittal data is valid for a period of 6 months from the date of submittal generation. If six months or more has elapsed between submittal generation and equipment release, the product performance and submittal data will need to be verified. It is the customer s responsibility to obtain such verification. Table of Contents Product Summary... Split System Air Conditioning Units (Small) (Items A A3) Tag Data... 2 Product Data... 2 Mechanical Specifications... 4 Unit Dimensions... 6 J:\JOBS\63\320936\2\City of Carrollton Fire Splits submittal.doc

Item Tag(s) Qty Description Model Number A No Tag Kitchen 4TTR4060L0000 S8XC00M5PSA 4TXCC009DS3HC A2 No Tag 2 Dorm Area, Toilet Area 4TTR4036L0000 S8XB060M3PSA 4TXCB004DS3HC A3 No Tag Workout 4TTR408L0000 S8XA026M2PSA 4TXCA002DS3HC Product Data Split System Air Conditioning Units (Small) Item: A Qty: Split System Cooling Outdoor Unit 5 Ton Nominal Cooling Capacity 200 230 Volt Phase 60 Hertz Single Stage Gas NonCond. 2" Wide 00,000 Heating input BTUH 4Way (Upflow/Horz Left/Right, Downflow) 5 Ton Capacity Permanent split capacitor Two Speed Standard 24 Volt Major Design Squence A Cased upflow/dnflow/horiz left 2.0"/9.8" cabinet Brazed 60,000 Nominal cooling capacity Hi efficiency TXVNon bleed Convupflow/dnflw,left airflow coil st Year labor warranty Item: A2 Qty: 2 Split System Cooling Outdoor Unit 3 Ton Nominal Cooling Capacity 200 230 Volt Phase 60 Hertz Single Stage Gas NonCond. 7.5" Wide 60,000 Heating input BTUH 4Way (Upflow/Horz Left/Right, Downflow) 3 Ton Capacity Permanent split capacitor Two Speed Standard 24 Volt Major Design Squence A Cased upflow/dnflow/horiz left 7.5"/6.3"cabinet Brazed 36,000 Nominal cooling capacity Hi efficiency TXVNon bleed Convupflow/dnflw,left airflow coil st Year labor warranty Item: A3 Qty: Split System Cooling Outdoor Unit.5 Ton Nominal Cooling Capacity 200 230 Volt Phase 60 Hertz Single Stage Gas NonCond. 4.5" Wide 26,000 Heating input BTUH 4Way (Upflow/Horz Left/Right, Downflow) 2 Ton Capacity Permanent split capacitor Two Speed Equipment Submittal Page 2 of 6

Standard 24 Volt Major Design Squence A Cased upflow/dnflow/horiz left 4.5" /3.3"cabinet Brazed 24,000 Nominal cooling capacity Hi efficiency TXVNon bleed Convupflow/dnflw,left airflow coil st Year labor warranty Equipment Submittal Page 3 of 6

Mechanical Specifications Split System Air Conditioning Units (Small) Item: A A3 Qty: 4 4TXC General Upflow, Downflow, or Horizontal coils shall be designed for cooling and heat pump applications. The coil shall be 3/8" seamless aluminum tubing me chanically bonded to aluminum plate fin. Refrigerant for the TXC coils shall be controlled with factory installed NonBleed TXV refrigerant control. Refrigerant connections are brazed fittings with an additional Schrader Valve for system service. The coil cabinet shall have a removable front and interior access panel for evaporator coil entering air surface cleaning. The coil includes a drain pan with drain connections for vertical or horizontal operation and a horizontal auxiliary drain pan. These coils are A.R.I. certified with Trane's matching condensing units. 4TXC Accessories Evaporator Defrost Control installed on coil for lower ambient operating conditions. 4TTR4 General The Outdoor Units are fully charged from the factory for up to 5 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 5F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 995. Exterior is designed for outdoor application. 4TTR4 Casing Unit casing is constructed of heavy gauge, G60 galvanized steel and painted with a weather resistant powder paint on all louvered panels and prepaint on all other panels. Corrosion and weatherproof CMBPG30 base. 4TTR4 Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory supplied liquid line drier is standard. Some models may require field installation. 4TTR4 Compressor The compressor features internal over temperature, pressure protection and total dipped hermetic motor. Other features include: Centrifugal oil pump and low vibration and noise. 4TTR4 Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. 4TTR4 Low Ambient Cooling As manufactured, this system has a cooling capacity to 55F. The addition of an evaporator defrost control permits operation to 40F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30F. S8X GENERAL OPERATION The SSeries furnace utilizes a Silicon Nitride Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter b. Vent proving pressure switches. S8X NATURAL GAS MODELS Central Heating furnace designs are certified by Intertek for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. S8X SAFE OPERATION The Integrated System Control is a solid state device which continuously monitors for presence of flame when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide additional safety. S8X QUICK HEATING Durable, cycle tested, heavy gauge tubular aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a discharge of gas fumes to the outside. Equipment Submittal Page 4 of 6

S8X BURNERS Multiport, Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas with LP conversion kit. S8X INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. S8X ENERGY EFFICIENT OPERATION AirTite? cabinet design is certified to <% air leakage per ASHRAE 93?Method of Test for Determining the Airtightness of HVAC Equipment.? S8X AIR DELIVERY The 9 speed constant torque blower motor has sufficient airflow for most heating and cooling requirements and will switch from heating to cooling speeds on demand from room thermostat. S8X STYLING Heavy gauge steel and "wraparound" cabinet construction is used in the cabinet with bakedon enamel finish for strength and beauty. Every orientation has at least two venting options. There are no knockouts on cabinet. Equipment Submittal Page 5 of 6

Item: A Qty: 37 /4" UNIT DIMENSTIONS DIM D 7/8" DIM E 3/8" SERVICE PANEL SEE NOTE 2 34 /4" NOTES. TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 60" ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUNOFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 2" FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. 2. ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES. " ELECTRICAL SERVICE PANEL 7/8" DIA. HOLE LOW VOLTAGE 20" /8" DIA. K.O. WITH 7/8" DIA. HOLE IN CONTROL BOX BOTTOM FOR ELECTRICAL POWER SUPPLY " 37 /8" LIQUID LINE SERVICE VALVE, "E" I.D. FEMALE BRAZE 8 5/8" 6" 8 5/8" 6" LIQUID LINE SERVICE VALVE, "E" I.D. FEMALE BRAZE 3 3/8" 3 7/8" GAS LINE /4" TURN BALL SERVICE VALVE, "D" I.D. FEMALE BRAZED 3 3/8" 3 7/8" GAS LINE SERVICE VALVE, "D" I.D. FEMALE BRAZED Equipment Submittal Page 6 of 6

Item: A Qty: ELECTRICAL / GENERAL DATA GENERAL Model: Voltage: Unit Hertz: Unit POWER CONN. 4TTR4060 Minimum Circuit Ampacity: 3.0 208 230 60 Maximum Circuit Breaker: Minimum Protection Rating: 50.0 50.0 COMPRESSOR Rated Load Amps: Locked Rotor Amps: 23.7 52.5 OUTDOOR MOTOR Horsepower: Motor Speed (RPM): Full Load Amps: Locked Rotor Amps: 0.20 0.95 NOTES:. Certified in accordance with the Unitary AirConditioner equipment certification program which is based on AHRI Standard 20/240. 2. Calculated in accordance with N.E.C. Use only HACR circuit breakers or fuses. 3. Standard line lengths 60'. Standard lift 60' Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub# 323320 4. * = 5, 20, 25, 30, 40 and 50 foot lineset available. REFRIGERANT Charge: Line Size O.D. Gas: Line Size O.D. LIQ: R40 7.6 lb 7/8" 3/8" NET SHIPPING WEIGHT 2.0 lb 246.0 lb NOTES: C. TOP DISCHARGE SHOULD BE UNRESTRICTED FOR AT LEAST 60" ABOVE UNIT C2. PLACE UNIT FROM WALL C3. PLACE SHRUBBERY AT LEAST 2" FROM UNIT ON TWO SIDES, OTHER SIDES UNRESTRICTED C4. PLACE UNIT SO ROOF RUNOFF DOES NOT FALL DIRECTLY ON UNIT C DISCHARGE C4 C3 C2 C3 WEIGHT AND CLEARANCE Equipment Submittal Page 7 of 6

Item: A Qty: A 4 7/6" DUCT FLANGE SCHRADER VALVE GAS CONNECTION LIQUID CONNECTION /2" /6" 2 /2" 3 /6" /4" 3/4" 5 /2" 9/6" 3/6" 3 5/8" 3/4" D C B 3/4" 2 /2" PLUGGED SECONDARY DRAIN 3/4" 4 NPT FOR HORIZONTAL POSITION PLUGGED PRIMARY DRAIN 3/4" 4 NPT FOR HORIZONTAL POSITION PRIMARY DRAIN 3/4" 4 NPT FOR VERTICAL POSITION PLUGGED SECONDARY DRAIN 3/4" 4 NPT FOR VERTICAL POSITION 4TXCD009 DIMENSION (A) DIMENSION (B) DIMENSION (C) DIMENSION (D) MATCHED FURNACE WIDTH GAS CONNECTION LIQUID CONNECTION DRAIN PAN WEIGHT NET 30 /6" 2" 20 /8" 9 /4" 24 /2" 3/4" BRAZE 3/8" BRAZE REFRIGERANT CONTROL TXV (NONBLEED) PLASTIC 68.0 lb 9 5/6" 3/4" 8 /8" OPENING IN WRAPPER 2 /2" Equipment Submittal Page 8 of 6

Item: A Qty: Furnace ELECTRICAL / GENERAL DATA GENERAL POWER CONN COMBUSTION FAN BLOWER DRIVE Model: Voltage: Ampacity (Amps): Max Over. Pro. (Amps): S8XC00M5PSAA 20//60 4. 5.0 Motor HP: Motor Speed RPM: Full Load Amps: Centrifugal 3300 0.30 Drive: No. Used: Motor HP: Speed RPM: FLA: Direct.0 075 0.9 ORIFICES RATINGS (b) FILTERS Nat. Gas Qty Drill Size: L.P. Gas Qty. Drill Size: Gas Valve: 5 45 Redundant Single Stage st Stage input BTUH: st Stage Capacity BTUH (ICS): 00000 80000 2st Stage input BTUH: 2st Stage Capacity BTUH (ICS) (c,d) : Furnished: Recommended High Velocity No 20"x25"x" BURNERS 20 V SiNi Igniter 5 st Stage Temp. Rise (Min.Max.) : 2nd Stage Temp. Rise (Min.Max.): AFUE ( %) (c,d): 3060 80 WEIGHT / DIMENSIONS Shipping: Net: Dimension (Crated): 44.0 lb 36.0 lb 35 /2"x23"x30 7/8" Notes: (a) Meets Energy Star (b) For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4 % per,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4 % per,000 feet for elevations above 4,500 feet above sea level. (c) Central Furnace heating designs are certified to ANSI Z2.47 / CSA 2.3 latest edition. (d) Based on U.S. government standard tests. (e) Refer to the Vent Length Table in the Installer's Guide. (f) All S9V2 furnace models have a vent outlet diameter that equals 2 in. (g) The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. Equipment Submittal Page 9 of 6

Item: A2 Qty: 2 32 5/8" SERVICE PANEL SEE NOTE 2 29 3/4" NOTES. TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 60" ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUNOFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 2" FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. 2. ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES. " ELECTRICAL SERVICE PANEL 7/8" DIA. HOLE LOW VOLTAGE 20" /8" DIA. K.O. WITH 7/8" DIA. HOLE IN CONTROL BOX BOTTOM FOR ELECTRICAL POWER SUPPLY " 32 3/4" LIQUID LINE SERVICE VALVE, 3/8" I.D. FEMALE BRAZE 7 3/4" 5" 7 3/4" 5" LIQUID LINE SERVICE VALVE, 3/8" I.D. FEMALE BRAZE 2 3/8" 3" GAS LINE /4" TURN BALL SERVICE VALVE, 3/4" I.D. FEMALE BRAZED 2 3/8" 3" GAS LINE SERVICE VALVE, 3/4" I.D. FEMALE BRAZED Equipment Submittal Page 0 of 6

Item: A2 Qty: 2 ELECTRICAL / GENERAL DATA GENERAL Model: Voltage: Unit Hertz: Unit POWER CONN. 4TTR4036 Minimum Circuit Ampacity: 8.0 208 230 60 Maximum Circuit Breaker: Minimum Protection Rating: 30.0 30.0 COMPRESSOR Rated Load Amps: Locked Rotor Amps: 4. 72.0 OUTDOOR MOTOR Horsepower: Motor Speed (RPM): Full Load Amps: Locked Rotor Amps: 0.25 0.64 NOTES:. Certified in accordance with the Unitary AirConditioner equipment certification program which is based on AHRI Standard 20/240. 2. Calculated in accordance with N.E.C. Use only HACR circuit breakers or fuses. 3. Standard line lengths 60'. Standard lift 60' Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub# 323320 4. * = 5, 20, 25, 30, 40 and 50 foot lineset available. REFRIGERANT Charge: Line Size O.D. Gas: Line Size O.D. LIQ: R40 6. lb 3/4" 3/8" NET SHIPPING WEIGHT 56.0 lb 83.0 lb NOTES: C. TOP DISCHARGE SHOULD BE UNRESTRICTED FOR AT LEAST 60" ABOVE UNIT C2. PLACE UNIT FROM WALL C3. PLACE SHRUBBERY AT LEAST 2" FROM UNIT ON TWO SIDES, OTHER SIDES UNRESTRICTED C4. PLACE UNIT SO ROOF RUNOFF DOES NOT FALL DIRECTLY ON UNIT C DISCHARGE C4 C3 C2 C3 WEIGHT AND CLEARANCE Equipment Submittal Page of 6

Item: A2 Qty: 2 A 4 7/6" DUCT FLANGE SCHRADER VALVE GAS CONNECTION LIQUID CONNECTION /2" /6" 2 /2" 3 /6" /4" 3/4" 5 /2" 9/6" 3/6" 3 5/8" 3/4" D C B 3/4" 2 /2" PLUGGED SECONDARY DRAIN 3/4" 4 NPT FOR HORIZONTAL POSITION PLUGGED PRIMARY DRAIN 3/4" 4 NPT FOR HORIZONTAL POSITION PRIMARY DRAIN 3/4" 4 NPT FOR VERTICAL POSITION PLUGGED SECONDARY DRAIN 3/4" 4 NPT FOR VERTICAL POSITION 4TXCB004 DIMENSION (A) DIMENSION (B) DIMENSION (C) DIMENSION (D) MATCHED FURNACE WIDTH GAS CONNECTION LIQUID CONNECTION DRAIN PAN WEIGHT NET 22 /2" 7 /2" 6 5/8" 5 3/4" 7 /2" 3/4" BRAZE 3/8" BRAZE REFRIGERANT CONTROL TXV (NONBLEED) PLASTIC 50.0 lb 9 5/6" 3/4" 8 /8" OPENING IN WRAPPER 2 /2" Equipment Submittal Page 2 of 6

Item: A2 Qty: 2 Furnace ELECTRICAL / GENERAL DATA GENERAL POWER CONN COMBUSTION FAN BLOWER DRIVE Model: Voltage: Ampacity (Amps): Max Over. Pro. (Amps): S8XB060M3PSAA 20//60 0. 5.0 Motor HP: Motor Speed RPM: Full Load Amps: Centrifugal 3300.39 Drive: No. Used: Motor HP: Speed RPM: FLA: Direct 0.5 075 6.8 ORIFICES RATINGS (b) FILTERS Nat. Gas Qty Drill Size: L.P. Gas Qty. Drill Size: Gas Valve: 3 45 Redundant Single Stage st Stage input BTUH: st Stage Capacity BTUH (ICS): 60000 48000 2st Stage input BTUH: 2st Stage Capacity BTUH (ICS) (c,d) : Furnished: Recommended High Velocity No 6"x25"x" BURNERS 20 V SiNi Igniter 3 st Stage Temp. Rise (Min.Max.) : 2nd Stage Temp. Rise (Min.Max.): AFUE ( %) (c,d): 3060 80 WEIGHT / DIMENSIONS Shipping: Net: Dimension (Crated): 30.0 lb 22.0 lb 35 /2"x9 /2"x30 7/8" Notes: (a) Meets Energy Star (b) For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4 % per,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4 % per,000 feet for elevations above 4,500 feet above sea level. (c) Central Furnace heating designs are certified to ANSI Z2.47 / CSA 2.3 latest edition. (d) Based on U.S. government standard tests. (e) Refer to the Vent Length Table in the Installer's Guide. (f) All S9V2 furnace models have a vent outlet diameter that equals 2 in. (g) The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. Equipment Submittal Page 3 of 6

Item: A3 Qty: SERVICE PANEL SEE NOTE 2 28 /2" 25 5/8" NOTES. TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 60" ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUNOFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 2" FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. 2. ELECTRICAL AND REFRIGERANT COMPONENT CLEARANCES PER PREVAILING CODES. " ELECTRICAL SERVICE PANEL 7/8" DIA. HOLE LOW VOLTAGE 8" /8" DIA. K.O. WITH 7/8" DIA. HOLE IN CONTROL BOX BOTTOM FOR ELECTRICAL POWER SUPPLY " 28 3/4" LIQUID LINE SERVICE VALVE, 3/8" I.D. FEMALE BRAZE 7 5/8" 5" 7 5/8" 5" LIQUID LINE SERVICE VALVE, 3/8" I.D. FEMALE BRAZE /2" 2 /4" GAS LINE /4" TURN BALL SERVICE VALVE, 3/4" I.D. FEMALE BRAZED /2" 2 /4" GAS LINE SERVICE VALVE, 3/4" I.D. FEMALE BRAZED Equipment Submittal Page 4 of 6

Item: A3 Qty: ELECTRICAL / GENERAL DATA GENERAL Model: Voltage: Unit Hertz: Unit POWER CONN. 4TTR408 Minimum Circuit Ampacity: 2.0 208 230 60 Maximum Circuit Breaker: Minimum Protection Rating: 20.0 20.0 COMPRESSOR Rated Load Amps: Locked Rotor Amps: 9.0 63.0 OUTDOOR MOTOR Horsepower: Motor Speed (RPM): Full Load Amps: Locked Rotor Amps: 0.06 0.60 NOTES:. Certified in accordance with the Unitary AirConditioner equipment certification program which is based on AHRI Standard 20/240. 2. Calculated in accordance with N.E.C. Use only HACR circuit breakers or fuses. 3. Standard line lengths 60'. Standard lift 60' Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub# 323320 4. * = 5, 20, 25, 30, 40 and 50 foot lineset available. REFRIGERANT Charge: Line Size O.D. Gas: Line Size O.D. LIQ: R40 4.5 lb 3/4" 3/8" NET SHIPPING WEIGHT 33.0 lb 53.0 lb NOTES: C. TOP DISCHARGE SHOULD BE UNRESTRICTED FOR AT LEAST 60" ABOVE UNIT C2. PLACE UNIT FROM WALL C3. PLACE SHRUBBERY AT LEAST 2" FROM UNIT ON TWO SIDES, OTHER SIDES UNRESTRICTED C4. PLACE UNIT SO ROOF RUNOFF DOES NOT FALL DIRECTLY ON UNIT C DISCHARGE C4 C3 C2 C3 WEIGHT AND CLEARANCE Equipment Submittal Page 5 of 6

Item: A3 Qty: Furnace ELECTRICAL / GENERAL DATA GENERAL POWER CONN COMBUSTION FAN BLOWER DRIVE Model: Voltage: Ampacity (Amps): Max Over. Pro. (Amps): S8XA026M2PSAA 20//60 7.6 5.0 Motor HP: Motor Speed RPM: Full Load Amps: Centrifugal 3300.39 Drive: No. Used: Motor HP: Speed RPM: FLA: Direct 0.333 075 4.8 ORIFICES RATINGS (b) FILTERS Nat. Gas Qty Drill Size: L.P. Gas Qty. Drill Size: Gas Valve: 2 5 Redundant Single Stage st Stage input BTUH: st Stage Capacity BTUH (ICS): 26000 24000 2st Stage input BTUH: 2st Stage Capacity BTUH (ICS) (c,d) : Furnished: Recommended High Velocity No 4"x25"x" BURNERS 20 V SiNi Igniter 2 st Stage Temp. Rise (Min.Max.) : 2nd Stage Temp. Rise (Min.Max.): AFUE ( %) (c,d): 2555 80 WEIGHT / DIMENSIONS Shipping: Net: Dimension (Crated): 02.0 lb 94.0 lb 35 /2"x6 /2"x30 7/8" Notes: (a) Meets Energy Star (b) For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4 % per,000 feet for elevations above 2,000 feet above sea level. For Canadian applications, above input ratings (BTUH) are up to 4,500 feet, derate 4 % per,000 feet for elevations above 4,500 feet above sea level. (c) Central Furnace heating designs are certified to ANSI Z2.47 / CSA 2.3 latest edition. (d) Based on U.S. government standard tests. (e) Refer to the Vent Length Table in the Installer's Guide. (f) All S9V2 furnace models have a vent outlet diameter that equals 2 in. (g) The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. Equipment Submittal Page 6 of 6