Troubleshooting Guide

Similar documents
Troubleshooting Guide

Gas Safety Products. Installation, operating and maintenance 28/10/2015. Merlin CT1250 Gas Interlock System. S&S Northern Ltd 1

Gas Safety Products. Installation, operating and maintenance 09/05/2016. Merlin CT1650+ Gas Interlock System. S&S Northern Ltd 1

Product Data Sheet. Merlin GDP2. Gas Safety Products. Merlin GDP2. Installation, operating and maintenance 23/08/2016. S&S Northern Ltd 1

Gas Safety Products. Installation, operating and maintenance 23/08/2016. Merlin 1000BH Gas Proving/Gas Detection System

Gas Safety Products. Installation, operating and maintenance. Merlin 1000VW+ Gas Interlock, Gas Proving, Electric & Water Isolation System

MERLIN RANGE KITCHEN EQUIPMENT CT1200S CT1250

Gas Safety Products. Installation, operating and maintenance. Merlin 1000BH Gas Proving/Gas Detection System

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. American Gas Safety LLC 1 05/10/2016

Gas Safety Products. Installation, operating and maintenance. Merlin 1500S Gas Interlock System. Rev: 03 Date:

Gas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Read these instructions carefully before operating or servicing.

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 4500PPM. Merlin CO2 Monitor. Rev: 11 Date:

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:

Gas Safety Products. Installation, operating and maintenance. Merlin Gas Detectors. Merlin Gas Detectors. Rev: 09 Date: Product Data Sheet

MERLIN RANGE GAS DETECTION EQUIPMENT

Gas Safety Products. Installation, operating and maintenance. Merlin CO2 Monitor 2800PPM. Merlin CO2 Monitor 2800ppm. American Gas Safety LLC 1

Gas Safety Products. Installation, operating and maintenance 11/26/2015. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1

Gas Safety Products. Installation, operating and maintenance 10/12/2017. Merlin Gas Detectors. Merlin Gas Detectors. American Gas Safety LLC 1

Boiler Room Control THE MERLIN RANGE GAS DETECTION EQUIPMENT ENGINEERED TO DELIVER EXCEPTIONAL LEVELS OF SAFETY

Installation Instructions

INSTALLATION & OPERATION MANUAL

100 Series Gas Ventilation Interlock System

Ozone Generator and Ozone PCB Tests and Fault Troubleshooting

1 Dimensions Installation Mains/boosted cold water inlet Connection to the system Drain Dimension for fixing 6

Pneumatic Heat Press. Revision: 3 Operators Manual

Please read this sheet as it contains important information

GROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer. Users Manual

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Controlled Thaw Cabinets

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

DMWD 1 to 4 Zone Water Detection Alarm with Distance to Leak Measurement Installation and Operation Manual

BX444-Mc Gas Detector

Installation, Operation and Maintenance Manual

VGPS-evo V3.3. Installation Instructions. The VGPS-evo is a gas pressure proving system with ventilation interlock and optional CO2 detection.

POWERFOIL X3.0 ELECTRICAL SPECS & DIAGRAMS

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Manitex Operation Manual

Installation Instructions. The SEC-L is a gas pressure proving system with water and electric isolation, gas detection and ventilation interlock.

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

M113S Users Manual. MERLIN STEALTH M113S Electric Fence Energizer GROUP OF COMPANIES. PDF created with pdffactory trial version

Humidifiers Dealer Parts List

The CAB & DAB Air Curtains

Touchpad controller User Manual installation operation

MAXI & MAXI PLUS Floor mounted Pressure manager TECHNICAL DOCUMENTATION. Issue 06/14

Humidifiers. Model 400/400M Humidifiers NO. BLUE/GRAY UNITS - PART NAME QTY/CTN PART NO. PART NO.

GS100M Gas Detection Controller

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY

Portable Refrigerator

TWZ/CT/ODV Series. Oil-Fired Hot Water Boilers (Less Tankless Heater) These instructions must be affixed on or adjacent to the boiler

INSTRUCTION MANUAL FOR OIL BURNER MODELS

GPPS-evo V3.3. Installation Instructions

ICM Simple Systems. CC750 Comfort Control Center CC and CC Application Guide

GS100M Gas Detector. Technical Specification

BX444-M Gas Detector. Features. Application. Operation

ULTRA-SAFE Explosion-proof Duct Heaters

BOSCH CONDENS 5000W ZSB18-2A

NXM2G Installation and Operating Manual

Frost Units for air temperature monitoring

Insight Operating Manual

Gas interlock system S & 100 CS

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

PORTAPAC / DELTA HOT. Installation and Operation Manual. ! WARNING

OPERATING INSTRUCTIONS

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for unvented systems.

www. ElectricalPartManuals. com GADP Ground Fault Indication System Instruction Manual Ground Fault Protection

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

AquaSaver DISPOSER CONTROL CENTER Installation Manual. Model AS-101K

November 11, City of Sparks 215 S. 21 st St. Sparks, NV

VF X Series. User Manual. SKOPE Vertical Freezer. MAN11137 Rev. 1.1 Sep VF650X

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

Catalogue. ActionpacEMSStandard. Electro Mechanical Control & Monitoring System.

Heatrix Electric Duct Heater HXOB Installation Instructions

SERIES FAN VAV TERMINAL BOXES TYPE CVFB & SFTB

User Manual THR842DUK Wireless Digital Thermostat

24V PCU CORE FIRE PROTECTION INSTALLATION SUMMARY

EBC12-EU-01. Product Instruction fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

SERVICE MANUAL. Ecoboiler Model range: T20 ( ) T30 ( )

TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C)

Powers Controls Low Temperature Detection Thermostat

Liebert Small System MCD and PFH Condensers (1-5 Ton) Warranty Inspection Check Sheet

EC Series Wall Unit Humidifier

OPERATION & MAINTENANCE MANUAL

ULTRA-SAFE Explosion-proof Duct Heaters

SUPREME 140, 155, 170

AlertMaxx2. Installation & Operating Manual. Ground Water (DMS-298) Pump Station High Level Alarm

Multi Function Control System for Boiler and Plant rooms SEC-B. The Home of Control & Automation in Ireland

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Humidifiers Dealer Parts List Model 400/400M Humidifiers

GS300M Gas Detector. Features. Application. Operation

Installation Instructions Owner s Manual

FUNCTIONAL DESIGN SPECIFICATION

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

READ AND SAVE THESE INSTALLATION INSTRUCTIONS

Scully ST-15 WX. Technical Manual. Multi-Point Liquid-Level Detection System

GB24 & GB30. User Manual

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

Transcription:

Gas Safety Products 26/01/2016 S&S Northern Ltd 1

Table of contents 1 General information... 3 2 Fault LED... 3 2.1 No Power LED Illuminated... 3 2.2 Emergency Stop Fault... 3 2.3 Fan Fault... 3 2.4 Additional common faults... 3 3 Operation Instructions... 4 3.1 How to turn the system on and off... 4 CT1200S Wiring Diagram... 4 S&S Northern Ltd 2

1 General information The Merlin CT1200S is a ventilation interlock panel. The Merlin CT1200S can receive connections from remote air pressure differential switches or current monitors and remote emergency shut-off buttons. It can also be integrated with a BMS and fire alarm. 2 Fault LED 2.1 No Power LED Illuminated 1 If the system is connected to the mains supply, the Power LED will illuminate. Please ensure there is in fact 230/240V going to the Power IN terminal. 2 If the system is connected to the mains supply and the power LED is not illuminated please check to see if the 3A fuse is still intact. 3 If none of the above have rectified the fault please contact S&S Northern for further assistance. 2.2 Emergency Stop Fault 1 If the front fascia emergency stop has been pressed, please re-press the button to release then reset the panel using the key switch. 2 If you have a remote emergency stop connected to the Merlin CT1200S please ensure this has not been activated. If this has please reset the emergency stop then reset the CT1200S with the key. 3 If you have multiple remote emergency stops connected to the same control panel, please ensure these have been wired in a loop series to our panel and connected to the EM REM terminal in the Merlin CT1200S. 4 If you are not using an additional emergency stop, please ensure the EM REM terminal is linked out. Check that the link is securely connected by ensuring you have continuity. 5 If none of the above have rectified the fault please contact S&S Northern for further assistance. 2.3 Fan Fault 1 Ensure the fan(s) are operational. 2 If you are using an air pressure differential switch please ensure this is correctly wired using the normally open contact on the air pressure differential switch so that a closed signal is sent back to the Merlin CT1200S when air flow is seen. For further information on the location and installation please contact S&S Northern for further assistance. 3 If you are using an external switch, please ensure that the red on LED light is illuminated. If it s not illuminated firstly confirm that the fan is in fact on, if it is, to increase the sensitivity of the switch you may need to increase the number of loops the live wire is taken through the coil. 4 If none of the above have resolved the issue or you would like any technical assistance please contact S&S Northern. 2.4 Additional common faults 1 Gas is on without the fans running - The fan PD terminal links have been left in? 2 Incorrect air pressure differential switch wiring. 3 The air pressure differential switch is not picking up airflow. The probe may have to be located to a more sensitive area in the duct. 4 Service LED is illuminated The service dipswitch will be set to the ON position. This may have been done to bypass one of the 2.3 faults for maintenance purposes. S&S Northern Ltd 3

3 Operation Instructions 3.1 How to turn the system on and off 1. Turn the Fans On. 2. Turn the key switch to on position. 3. To turn the system off, turn the key switch to off position. CT1200S Wiring Diagram 1. Mains Input 230VAC Single Phase. 2. Gas Solenoid Valve Power Output, 230VAC. 3. BMS output contacts. Normally Closed, Common and Normally Open. 4. Input for remote EM Stop buttons & / or Fire Alarm input wired in series (purchased separately). VOLT FREE INPUT 5. Supply Fan pressure differential switch or current switch. VOLT FREE INPUT 6. Extract Fan pressure differential switch or current switch. VOLT FREE INPUT 7. Service Switch Please note, Mains wires and low voltage wires should not be run in the same conduit as per the LOW VOLTAGE DIRECTIVE S&S Northern Ltd 4

CONTACT US: S&S Northern Head Office Tel: +44(0) 1257 470 983 Fax: +44(0) 1257 471 937 www.snsnorthern.com info@snsnorthern.com South East Division Tel: +44(0) 1702 291 725 Fax: +44(0) 1702 299 148 south@snsnorthern.com Rev Date Author Description 03 26.01.16 S&S Northern SH + BT Merlin CT1200S Third issue S&S Northern is the owner of this document and reserves all rights of modification without prior notice. S&S Northern Ltd 5