Comfort Series Instant Hot Water System

Similar documents
INSTANT HOT WATER RECIRCULATING SYSTEM

LiqTec, V GRUNDFOS INSTRUCTIONS

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

Installation and Operating Instructions

GRUNDFOS INSTRUCTIONS CMBE. Installation and operating instructions. Drinking Water System Component NSF / ANSI 61 NSF / ANSI 372

GRUNDFOS INSTRUCTIONS UPZCP-3, 4, 6. Multi-zone pump control. Installation and operating instructions

Instruction Sheet AquaMotionHot One AMH1K-1 Point of Use Hot Water Recirculation System

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

Pre-Fab Easy Installation For Model 0011-CF-USK Installation and Operating Instructions for Existing Homes Or Buildings with Standard Piping

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

WHOLE HOUSE FILTER &

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

Mini Tank water heater Electric undersink Water heaters GL GL 4 - GL 6+

Controlled Energy Corp. 340 Mad River Park Waitsfield, VT TOLL FREE

Murano Shower Cabin Installation Instruction

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

Condensate Pump. Installation and Safety Instructions CP-16 CP

Spa Control System OWNER S MANUAL

Electric Mini Tank Water Heaters ME10 ME25 ME40 ME60

ECCOTEMP. Point of Use Tankless Water Heaters EP-2.4 / EP-7.0. Installation and Operating Instruction Manual. Shop Online.

TrueClean ToteCleaner

TrueClean ToteCleaner

GRUNDFOS PLUMBING & HVAC PRODUCTS

Owner s Manual PUH1500. Electric Umbrella Heater. Model Number: Model Number Part Number. Quality checked by: R00

REMOTE FAUCET PUMP SYSTEM

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

LED LAMP: To turn on the LED Lamp, press the LIGHT BUTTON located on the front. Press again to turn off.

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

Mixing Degas Vessel (MDV) EC-1, EC-2, EC-4, Total Eclipse 2 or 4, and TrioPure-25 or TrioPure-50

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

Chilipepper CP9000. Installation Instructions READ BEFORE INSTALLING:

Thin Window FAN With Comfort Control Thermostat. Instruction Leaflet. pure indoor living MODEL: BWF0522M-CN

Instruction Leaflet. Read instructions before operating. Retain for future reference.

MODEL HBX-1 P/N 3G59332

TABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾

Model EPWHP. How to install, operate and maintain your Water Heater Protector. Do not return unit to store

IMPORTANT SAFETY INFORMATION:

GETZ MANUFACTURING PART # CYLINDER DRYER

Installation Instructions

OWNER S MANUAL & WARRANTY

GRUNDFOS INSTRUCTIONS MAGNA1. Installation and operating instructions

Model 9001, Alarm

TYPE LF/LC/LCV END SUCTION PUMPS

Viessmann B1HA Boiler Series

HUMIDITY SENSING BATH FAN

USER S OPERATING AND INSTRUCTION MANUAL

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

A2Z Ozone, Inc. PRODUCT MANUAL

Eco-Steamer SSC-0312 INSTRUCTION MANUAL CONTENTS

Model 9001, Alarm

INSTALLATION AND OPERATING MANUAL

Installation Instructions / Warranty. Starck 10111XX XX XX1

SYSTEM CONTROL KIT Model: CK-41P

SPA BLOWER OWNER'S MANUAL XXXX, XXXX, XXXX, XXXX, XXXX, XXXX fax

Installation Instructions / Warranty

OPERATION, SERVICE & PARTS MANUAL

DBF 4XL Dryer Booster Fans

IMPORTANT SAFETY INFORMATION:

EQUIPMENT Operation Manual

Model TWBS.EW.H Tempered Water Blending System

e Bath Fan with Light User s Guide

SAVE THESE INSTRUCTIONS

Instruction Manual. Bucket Oil Pump

SFH136-CN TRUSTED FOR OVER 100 YEARS. Sunbeam Heater. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

OPERATION, SERVICE & PARTS MANUAL

Installation Instructions / Warranty

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

OmniDry 2.9 Amp Centrifugal Air Mover

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS MODEL 50F / 70F / 70HS TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

CONSUMER SERVICES TECHNICAL EDUCATION GROUP PRESENTS


Installation Instructions / Warranty

INSTALLATION AND OPERATING MANUAL

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

Owner s Manual. Terpene Trap CF 1000

e Bath Fan with Light User s Guide

MOJAVE. Mojave ShowerSpa Model #1016 Owner's Manual

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG

120 VAC SYSTEM CONTROL KIT

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

Instruction Leaflet. Read instructions before operating. Retain for future reference.

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

Warnings 2. Installation Instructions 3. Wiring Instructions 3. Mounting Instructions 4. Replacement Element Installation 5. Replacement Parts 5

Hot Dog Roller Grills

VENTILATION FAN / LED LIGHT

Battery Powered In-line Valve with Watering Timer RBC 7000

CVS Model Inline Multi-Port Ventilators

MULTI-FUNCTION HAND VACUUM INSTRUCTION MANUAL. For Authentic Monster Replacement Parts Call Model #: H056

FLCH4R Garage and Utility Electric Heater

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Industrial Vacuums, Inc

INSTALLATION AND OPERATING MANUAL

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

HotPoly Tote Tank / IBC Heaters (TTH Series)

Installation Instructions / Warranty. Metris 31060XX XX XX1

Transcription:

GRUNDFOS INSTRUCTIONS Installation and Operation Comfort Series Instant Hot Water System ANSI/NSF61 and IAPMO listed

Shipment Inspection page 1. Pre-Installation Checklist page 1. Pump Mounting page 2. Electrical page 5. Timer Control Technical Data and Application page 5. Timer Operation page 6. Warranty page 7. CONGRATULATIONS! You are now the owner of a Grundfos Comfort System. It has been carefully inspected and tested before shipment. It should give you long, efficient, trouble-free service. For maximum performance and reliability, please follow the simple instructions in this manual. NOTE: Please understand this is not an anti-scald device. You may have some warm water in your cold water line under the sink where the valve is installed. Once the cold water line is opened, the warm water will dissipate in a very short time. Shipment Inspection Examine the components carefully to make sure no damage has occurred to the pump during shipment. Care should be taken to ensure the pump is NOT dropped or mishandled; dropping will damage the pump. Grundfos Hot Water Package Includes: One Grundfos UP15 circulator with timer and linecord One Under Sink, Thermal By-Pass Valve Two Valve mounting screws Installation and Operating Instructions Items that must be supplied by Installer: 2-1/2" NPT X 3/8" compression flex hoses 2-1/2" NPT X 1/2" NPT flex hoses Hand Tools Pre-Installation Checklist Before beginning installation procedures, the following checks should be made. They are all important for proper installation of the circulator pump. Maximum Water Temperature: UP15 pump with line cord and timer only; The maximum allowable water temperature is 150 F. In a pressurized system, the required inlet pressure is the minimum allowable system pressure. page 1

Pump Mounting: For Indoor Use Picture 1 1. Close the supply water valve to the water heater located, in most cases, above the hot water heater on the cold water inlet to the hot water heater. Disconnect 2. Drain the water from the hot water pipe by opening a hot water faucet in the house. Let the water run until it stops flowing. Then drain remaining water from hot water heater spigot. Leave the faucet open until pump installation is complete. If water does not stop flowing, check to make sure the water to the hot water heater has been completely shut off. 3. Disconnect the hot water heater at the hot water discharge. (see Picture #1) 4. Install pump onto the water heater discharge, using the 3/4" female fitting and gasket supplied on the pump ensuring that the pump shaft is horizontal. The pump should be installed so that the pump is pumping away from the hot water heater, towards the house. Confirm the direction of pumping by observing the flow arrow on the side of the pump housing. Be sure that Picture 2 the pump is not touching the exhaust vent piping (chimney) of a gas or oil fired hot water heater. (See Picture #2) 5. Connect the hot water line to the 3/4" NPT discharge of the pump. Use pipe dope or Teflon tape to seal threads when connecting to a 3/4 female NPT connection. If a gasketed flexible copper water heater connector is used pipe dope or Teflon tape is not required 6. Reopen the supply valve to the hot water heater and allow the water to run until all the air has been purged from the piping. 7. Close faucet inside the house. page 2 Direction of water

8. Plug the line cord of pump into a 115V outlet. Be sure to route the power cord so that it does not touch the exhaust vent piping of a gas or oil fired hot water heater. Picture 3 9. Using the timer (see pg. 6), set the pump to operate around your peak use times. (eg 30 minutes before the first shower until 15 minutes after last shower). Valve Location For the greatest effect, the valve should be located at a faucet with the greatest piping distance from the hot water heater. If your home has a branched hot water line, more than one valve may be necessary. Valve Installation Note: Do not use teflon tape or pipe dope on the valve threads. 1. Close both the hot and cold water angle stop valves below the sink. (see Picture #3) Picture 4 2. Disconnect the risers. (see Picture #4) 3. Connect the 1/2"X1/2" flex hoses to the ports on the valve marked Hot Out and "Cold Out". (see Picture #5) 4. Connect the 1/2"X3/8" flex hoses to the ports on the valve marked "Hot In" and Cold In. (see Picture #5) Please note: By plumbing convention, the hot water is on the left side and cold water on the right, when looking at the sink. Your piping may be different. page 3

5. Connect the 1/2" hose fitting from the "Hot Out" port to the left side of the faucet. (see Picture #5) 6. Connect the 1/2" hose fitting from the "Cold Out" port to the right side of the faucet. (see Picture #5) 7. Connect the 3/8" hose fitting from the Hot In port to the left angle stop valve. (see Picture #5) 8. Connect the 3/8" hose fitting from the Cold In port to the right angle stop valve. (see Picture #5) 9. Open both hot and cold water angle stop valves. 10. Valve may be mounted to the wall with supplied mounting screws if desired. Valve Operation If there is no hot water at the faucet or there appears to be too much hot water on the cold water side the following steps will determine if the valve is operating correctly: 1. Close the cold water angle stop valve below the sink. 2. Open the cold water faucet. 3. Water should slowly flow from the faucet until hot water reaches the valve. The flow should gradually decrease until no water is coming from the faucet at which time the valve is closed. Picture 5 Hot Water IN Hot Water OUT page 4 Cold Water OUT Cold Water IN

Electrical SAFETY WARNING Warning - Risk of electrical shock - This pump is supplied with a grounding conductor. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded grounding type receptacle. The safe operation of this pump requires that it be grounded in accordance with the National Electrical Code and local governing codes and regulations. Electrical Requirements The operating voltage and other electrical data are marked on the motor label. Make sure that the motor is suitable for the electrical supply on which it will be used. Electrical Connection Insert the 115V plug on the line cord from the pump into a properly grounded 115V outlet. Timer Technical Data TIMER CONTROL Supply Voltage: 115-120 VAC, 60 hertz Contact Rating: 16 amps Ambient Temperature: -4 F to 175 F Shortest Switching Interval: 15 minute increment Switch Modes: Timer, ON Override, OFF Override Protection: Clear plastic cover for dust and moisture protection of the clock face. Timer Technical Application The Grundfos timer control is designed only for use with specified Grundfos Series UP circulators installed in indoor hot water service systems. The timer control is designed to turn the circulator on and off at preset times, allowing the user to select operation of the circulator during high use periods of the day. page 5

Timer Operation Setting & Operating The Timer Control Starting the Pump OFF TIMER ON NOTE: Before the circulator is started, the system must be filled with liquid and vented. 1. Set the timer switch to the actual time by turning the programming ring in the direction of the arrow until the timing arrow points to the actual time on the ring. 2. Plug in the power cord from the circulator and set the manual switch to the ON position. The circulator will now start. 3. Set the required ON / OFF times on the programming ring by pushing the programming tabs either away from or toward the center of the ring. Tabs pushed away from the center indicate the circulator is switched ON while tabs pushed toward the center indicate the circulator is switched OFF. 4. Set the manual switch to the TIMER position. The circulator will now start/stop according to the settings of the programming tabs. 5. For continuous operation, set the manual switch to the ON position. To switch the circulator off, set the manual switch to the OFF position. The ON / OFF modes may be used without affecting the function of either the programming ring or the timer switch. 6. In case of power outage the timer will not keep time. After power has been restored, the correct time of day must be reset by rotating the programming ring in the direction of the arrow until the timing arrow points to the actual time on the ring. page 6

Limited Warranty Products manufactured by GRUNDFOS PUMPS CORPORATION (GRUNDFOS) are warranted to the original user only to be free of defects in material and workmanship for a period of 24 months from date of installation, but not more than 30 months from date of manufacture. GRUNDFOS' liability under this warranty shall be limited to repairing or replacing at GRUNDFOS' option, without charge, F.O.B. GRUNDFOS' factory or authorized service station, any product of GRUNDFOS manufacture. GRUNDFOS will not be liable for any costs of removal, installation, transportation, or any other charges which may arise in connection with a warranty claim. Products which are sold but not manufactured by GRUNDFOS are subject to the warranty provided by the manufacturer of said products and not by GRUNDFOS' warranty. GRUNDFOS will not be liable for damage or wear to products caused by abnormal operating conditions, accident, abuse, misuse, unauthorized alteration or repair, or if the product was not installed in accordance with GRUNDFOS' printed installation and operation instructions. To obtain service under this warranty, the defective product must be returned to the distributor or dealer of GRUNDFOS products from which it was purchased together with proof of purchase and installation date, failure date, and supporting installation data. Unless otherwise provided, the distributor or dealer will contact the GRUNDFOS factory or authorized service station for instructions. Any defective product to be returned to the factory or service station must be sent freight prepaid; documentation supporting the warranty claim and/or a Return Authorization must be included if so instructed. GRUNDFOS WILL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSSES, OR EXPENSES ARISING FROM INSTALLATION, USE, OR ANY OTHER CAUSES. THERE ARE NO EXPRESS OR IMPLIED WARRANTIES, INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHICH EXTEND BEYOND THOSE WARRANTIES DESCRIBED OR REFERRED TO ABOVE. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages and some jurisdictions do not allow limitations on how long implied warranties may last. Therefore, the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from jurisdiction to jurisdiction. LUPTL043 04/04 PRINTED IN USA Grundfos Pumps Corporation 17100 W. 118th Terrace Olathe, Kansas 66061 Telephone: (913) 227-3400 Fax: (913) 227-3500 Grundfos Canada, Inc. 2941 Brighton Rd. Oakville, Ontario L6H 6C9 Telephone: (905) 829-9533 Fax: (905) 829-9512 Bombas Grundfos de Mexico, S.A. de C.V. Boulevard TLC #15, Parque Industrial Stiva Aeropuerto C.P. 66600 Apodaca, N.L. Mexico Telephone: 52-81-8144-4000 Fax: 52-81-8144-4010 www.grundfos.com