Available online Journal of Scientific and Engineering Research, 2017, 4(12): Research Article

Similar documents
Compression of Fins pipe and simple Heat pipe Using CFD

Performance Analysis of Axial Flow Cooling Coil and Mixed Flow Cooling Coil in a Cold Storage using Numerical Method

A Study of Drying Uniformity in a New Design of Tray Dryer

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Available online Journal of Scientific and Engineering Research, 2017, 4(10): Research Article

Investigations Of Chinese Cabbage Cold Storage Chamber Operation

ENERGY SAVING IN A DOMESTIC SPLIT-TYPE AIR CONDITIONER WITH EVAPORATIVE COOLING SYSTEMS

MAL-DISTRIBUTION MODEL OF HEAT EXCHANGERS IN MICRO CHANNEL EVAPORATOR

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Performance investigation of Air-conditioning system using ejector as expansion device

Experimental Research and CFD Simulation on Microchannel Evaporator Header to Improve Heat Exchanger Efficiency

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

A study of Transient Performance of A Cascade Heat Pump System

Comparative Study of Transcritical CO 2 Cycle with and Without Suction Line Heat Exchanger at High Ambienttemperature

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Adsorption refrigeration system using waste heat

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

Evaluation of a dynamic model for a cold climate counter flow air to air heat exchanger

Specific Energy Consumption comparative study of Hot Air dryer and Heat Pump dryer for highland drying process Sayompon Srina

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

Global Journal of Engineering Science and Research Management

Effect of domestic storage and cooking conditions on the risk distribution in ready to cook meat products

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

International Journal of Scientific & Engineering Research, Volume 5, Issue 7, July-2014 ISSN

Performance Study on A Window Type Air Conditioner Condenser Using Alternative Refrigerant R407C

ENSC 388: Engineering Thermodynamics and Heat Transfer

PERFORMANCE ANALYSIS OF A RE-CIRCULATING HEAT PUMP DRYER

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

Design, Manufacturing of Chilled Water System for Process Cooling Application

H EDRICK ASSOCIATES OF GRAND RAPIDS West Michigan s Factory Representative

Constant climate chamber with ICH-compliant illumination

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

R07. Answer any FIVE Questions All Questions carry equal marks *****

Drying Parawood with Superheated Steam

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

COOLING SYSTEMS FOR CONTINOUS GALVANIZING LINE Miroslav Raudensky a, Milan Hnizdil a, Jaroslav Horsky a, FrédéricMarmonier b

Study of Hot-air Recirculation around Off-road Tier-4 Diesel Engine Unit Using CFD Abbreviations Keywords Abstract Introduction and Background

How to ensure Thermal Comfort in buildings with CFD

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

Available online Journal of Scientific and Engineering Research, 2018, 5(11): Research Article

APPLICATION OF CFD SIMULATIONS FOR LOCATING OUTDOOR UNITS ON HIGH RISE TOWER Basant Kumar Gupta 1, Anand Patil 2

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Development of Gas-Liquid Two-Phase Flow Distributor for Improving Energy Efficiency in Air-Conditioners

Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling

Constant climate chamber with humidity

THERMAL ANALYSIS OF CAR AIR COOLER

Constant climate chambers

Thermal Simulation of a Heat Pipe Tempered Injection-Mould Tool

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Flexible and efficient: Close Climate Control for IT equipment

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Solar Drying Techniques And Performance Analysis: A Review

Multiphase-Simulation of Membrane Humidifiers for PEM Fuel Cells

2. HEAT EXCHANGERS MESA

The Experimental Validation of Numerical Modeling of the Air Distribution in the Indoor Ice Rink Arena

Low GWP Refrigerants for Air Conditioning Applications

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Constant climate chambers

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

Optimized fan system design for the one-year cycle of a Heat Pump. Ziehl-Abegg SE Frieder Lörcher

High-efficiency Turbo Chiller (NART Series)

Feasibility of a Liquid Desiccant Application in an Evaporative. Cooling Assisted 100% Outdoor Air System

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Energy Transfer Based Test Method Development and Evaluation of Horizontal Air Flow Re- Circulatory Air Curtain Efficiencies

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Numerical study of heat pipe application in heat recovery systems

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

RIGID DC LIQUID CHILLER

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Design and Development of Water Cooled Condenser for Domestic Refrigerator

Experimental Study on Performance of Double pipe Length on Instantaneous Air Source Heat Pump Water Heater. Yin Shaoyou 1, a

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Performance Study of Triple Concentric Pipe Heat Exchanger

Transcription:

Available online www.jsaer.com, 2017, 4(12):203-209 Research Article ISSN: 2394-2630 CODEN(USA): JSERBR Evaluation of Ambient Temperature and Relative Humidity Distribution in Empty Cold Store with Chiller Serap Akdemir Technical Sciences Vocational School, Air Conditioning and Refrigeration Programme, Namik Kemal University, Tekirdağ, Turkey Abstract Properties of the ambient conditions in cold storage are very important for cold stored products. The homogeneity of storage environment conditions increases the storage time of stored products. The differences between the ambient temperature and relative humidity values were measured for different Y axis and levels (top, medium, base) for empty cold store with chiller unit. Spatial variability was tried to be determined at different levels. According to the results; mean temperature and relative humidity was measured as 2.82 o C and 87.86% for top, 2.81 o C and 88.24% for middle level and 2.82 o C and 87.93% for base level in the empty cold storage. There isn t big differences between levels in the experimental cold store with chiller. All the results showed that distribution of the ambient temperature and relative humidity were less than the conventional cold stores which has evaporative cooling system. Keywords cold storage, chiller, ambient temperature, relative humidity 1. Introduction The reason of this research is irregular distribution of cold air in the cold store. Differences in the ambient temperature and relative humidity have negative effects on the quality of the stored products. These irregularities cause quality and quantity losses in cold stored products. In practice, modern humidification systems are used rarely in the cold stores. Conventional humidification such as wetted nuts, water spraying by hand on surface or watering in aqua containers) have been used. The conventional humidification methods causes uneven distribution of the ambient the temperature and relative humidity Uneven distribution of the storage conditions cause quality loss and deterioration in the stored product. There is a direct relationship between moisture content and product quality in cold air storage during storage. For this reason, it is important to make the homogeny humidification in the cold stores. Heterogeneity in humidification is inevitable as commercial cold storage warehouses manufactured in large sizes. Temperature and humidity (vapour pressure difference) gradients between two media contacted with each other was gradual. The water-giving product first attempts to fill the air layer nearest to its surface. As a result, the vapour pressure gradually increases in the form of a hyperbolic curve. The air current removes the closest and most saturated air layer to the fruit, replacing the most unsaturated air mass. For this reason water loss from the crop increases significantly compared to the stagnant weather conditions [1]. The purpose of the study is to determine the differences in storage temperature and relative humidity for different layer in the cold store with chiller unit. Our hypothesis is that "if the ambient temperature and the local variability in relative humidity are reduced, the quality loss of the stored product will be less". 2. Review of the Literature The amount of the losses and quality changing of cold stored agricultural products in a cold store is very much dependent on the temperature fields which are highly related to the air flow fields [2] designed a two- 203

Akdemir S, 2017, 4(12):203-209 dimensional mathematical model in a model cold room and developed a computer program. Simulation results reflect the characteristics of air velocity and temperature distribution. After that, the parameters affecting the flow field (corners, product stack) were analysed. The results have shown that the product stack is particularly influenced by flow and temperature. A modelling method for simulating heat and mass transfer in cold storage of orchard products has been developed. This method is used to estimate the mass transfer of water vapour of packaged garden products. Heat transfer paths considered to be the most important factor for the packaging system were modelled. Experimental tests were conducted for 10 product packaging systems. Single-zone packaging was found to be sufficient in all tests, although the model supports multi-zone packaging systems [3]. A model has been developed for the estimation of latent heat, audible heat, moisture losses and temperature distribution in bulk storage of fruits and vegetables. The porous media approach has been applied to model respiration, sweating, convective heat and mass transfer. Temperature, air velocity and relative local variability of floor, centre and ceiling planes were determined in an experimental cold room, [4]. Maps and descriptive statistics were used to show the spatial variability. In order to maximize the efficiency of food cooling and freezing processes, it is necessary to optimize the design of the appropriate refrigeration equipment required for refrigeration and freezing. The cooling time must be determined depending on the cooling load in the design of the cooling equipment. Accurate estimation of these factors depends on precise determination of surface heat transfer coefficients for cooling and freezing operations. In order to determine the surface heat transfer coefficients, a cooling curve of 295 different foods were obtained by an industrial survey [5]. Investigations have been made on an ultrasonic humidifier used for unpacked fruit and vegetables sold at retail. In this research study, the products and equipment were compared with the 7 day tests. Experiments have compared fogging and non-steady methods. No significant difference was found in average product temperature. However, there are minor differences in the cooling performance of the cooling cabinet (in terms of ambient temperature and cooling effect). It has been determined that moisturizing reduces weight loss in all products. It was also found that the moisture loss on the stored products decreased. The microbial quality of the products has not been adversely affected by moisturizing. There was a slight increase in airborne micros in the case of wet fogging, but there was no statistical difference between the two applications [6]. The airflow in a cold room was investigated using CFD (computational fluid dynamics). The airflow pattern is made according to the conditions accepted as permanent and incompressible. Turbulence was taken into account using the k-ε model. The forced air circulation of the refrigerant unit was modelled in accordance with the approximate body strength and resistance associated with the characteristics of the evaporator air duct and fan. The validity of the model was calculated by comparing the calculated time-averaged speed values with the sensor values measured everywhere. The relative error of air velocity was observed to be 26% [7]. In a study; it was aimed to optimize and improve air distribution systems in refrigerated vehicles to reduce temperature differences across the entire palletized cargo. This condition is essential to protect the shelf life, quality and safety of perishable foods. Experiments were carried out in a reduced model of cooling devices (1:3:3). Performance related to ventilation and temperature homogeneity was characterized by a system with and without air channels. These two systems are widely used in trucks with refrigerant systems. Numerical modelling of the airflow was performed using Computational Fluid Dynamics (CFD) and Reynolds Stress model (RSM). The results obtained using the RSM showed good agreement with the experimental data. The modelling results and the experimental results clearly show that the temperature decreases between the cargoes in air-blown systems through the pipe [8]. 3. Materials and Methods 3.1. Cold store The cold store was 4 x 5 x 3 m in size. It was located in Namik Kemal University (NKU), Tekirdag. This cold store has a cooling system with chiller and the air has been cooled in the external unit before being blown onto the fruits through ducts. Polyurethane sandwich panel were used for the construction of the walls. After the construction of the building, all the walls and floors of the cold depot were formed with prefabricated sandwich 204

Akdemir S, 2017, 4(12):203-209 panels filled with polyurethane. Panel thickness is 80 mm. The polyurethane thermal conductivity coefficient is 0.025 W/mK according to DIN 4108. Both surfaces of the wall and ceiling panels are 0.50 mm thick, galvanized sheet painted with polyester based paint. The floor panels are covered with stainless steel sheet with a thickness of 0.50 mm on the imported plywood with 9 mm thickness on the inner surface and galvanized with 0.50 mm thickness on the outer surface and filled with 80 mm polyurethane. Then the sliding door was installed. The door surface is in the same direction as the panel surfaces (Figure 1). Figure 1: Cold store general view The cooling system consists of a water chiller, air cooling group, air conditioner, suction and discharge channels, and suction and discharge vents. Water cooling; Technical characteristics are shown in table 1 and the general view of the group is shown in Figure 2 with water cooled by R404a refrigerant in the water cooling group. Table 1: Technical specifications of water cooling unit Compressor model HGX 34P/215-4S Semi- Hermetic Cylinder type Evaporator / compressor temperature 0/+40 C Capacity 15 kw Compressor power 4.59 kw C.O.P 3.27 Water inlet/outlet temperature 10 C /6 C Refrigerant R 404A Air conditioning device: The technical features of the air conditioning device are given in Table 2 and Figure 2. Table 2: Technical specifications Air-conditioning unit Ventilator type Axial Air flow rate 8.000 m 3 /h Cooling unit capacity 10 kw Heat capacity 5 kw Inlet Air temperature/relative humidity (%) 19 C / 65% RH Outlet air temperature/relative humidity (%) 15 C 85%RH Water Input/output 6/11 C Heating type Electrical resistance Ventilator air flow rate Adjustable with inverter Figure 2: Air-conditioning unit, suction and pressure channels 205

Akdemir S, 2017, 4(12):203-209 The water cooled in the water cooling group provides cooling of the air in the cooling battery in the air conditioner. Cooled is blown into the discharge air channels at desired temperature and relative humidity values. Suction and pressure air channels: Air channels of ventilation device (air handling unit) is made of galvanized steel (Figure 8). In order to distribute the conditioned air coming from the discharge channels and to allow exhaust air for suction. in the cold store, three pressure vents and three suction vents were located on the ceiling of the cold store. All of this construction was in a closed loop to ensure that the air is sent to the cold store at the desired temperature and relative humidity and to take back the exhaust air. In Figure 4-a, suction bores are shown, in Figure 4-b the location of the bores were given. Establishment of the humidifier: A humidifier which its capacity was 2 kg/h steam was located in the cold room. The humidification requirement is provided by a sprayer placed in the discharge port. Electric Control Box; The electric control panel has internal locks, fuse, contactor, relay, lamp, switch, ampermeter etc. (Figure 3). Automatic control in the cooling system: With the microprocessor digital control panel, the heating, cooling and humidification processes have been realised in order to distribute air at the desired temperature values into the cold store. If there is any uncontrolled overheating in the heating system, the whole system can be stopped and the alarming function was activated. Figure 4 shows the representation of the room with the control panel. Temperature and relative humidity values can be read and set values can be changed from here, PID control of the system was realized by digital panel. Figure 3: Electrical control box Figure 4: Automatic control system of the cold store 3.2. Temperature and relative humidity sensors Temperature Sensors: Testo 177 H1 data logger was used to measure temperature at same time and same point [9]. Measurement ranges of the TESTO 177-H1 was between -20 C and + 70 C for temperature and 0%...and 100% for relative humidity (Figure 5). 206

Akdemir S, 2017, 4(12):203-209 Figure 5: Testo 177 H1 data logger 3.3. Methodology Ambient temperature has been set to +1 C and relative humidity set to 90 %. Spatial distribution of temperature was used by Testo 177 H1 data logger. The data were measured from 3 different Y axis at 3 levels for 4 points (Figure 6). Total number of the measurements was 36 points Figure 6: Measurement points in the cold store The Y planes were called as 1, 2, 3, and 4 (Fig. 10 a) and Z plane were called as top, middle and base in the variance analysis and evaluations (Fig. 10 b). In the evaluations obtained in the measurements, the planes in the Y axis and the planes in the Z axis were considered. a Figure 7: Planes and its codes for Y axis (a) and Z axis (b) b 207

Akdemir S, 2017, 4(12):203-209 Temperature and relative humidity measurements realised for empty cold storage. The cold store worked for 24 hours. Testo 177H1 data logger measurement frequency was 1 minute. Mean values of ambient temperature (t mean, o C) and relative humidity (RH mean, %) were calculated from 1440 data from 36 sensors. Descriptive statistics such as mean, minimum, maximum, standard deviation and coefficient of variation were calculated from measured data [10]. 4. Results and Discussions Results of temperature and relative humidity measurement for empty cold store were given in Table3. When the results of the investigated; mean, standard deviation and coefficient of variation value of the ambient temperature were determined as 2.82 O C, 0.02 O C and 0.62 %, respectively. Mean, standard deviation and coefficient of variation of relative humidity were calculated as 88.0%, 0.61% and 0.70%, respectively. Mean values of ambient temperature and relative humidity for different levels were given in Table 4 and for Y- axis in Table 5. Table 3: Mean ambient temperature ( o C) and relative humidity (%) Y-levels Z levels t mean ( o C) RH mean (%) 1 1 2.83 87.43 1 2 2.80 87.67 1 3 2.83 88.13 2 1 2.83 88.23 2 2 2.83 89.57 2 3 2.83 87.47 3 1 2.83 88.07 3 2 2.80 87.47 3 3 2.80 88.53 4 1 2.80 87.70 4 2 2.80 88.23 4 3 2.80 87.60 Mean 2.82 88.01 Minimum 2.80 87.43 Maximum 2.83 89.57 Standard deviation 0.02 0.61 Coefficient of variation (%) 0.62 0.70 Mean temperature and relative humidity was measured as 2.82 o C and 87.86% for top, 2.81 o C and 88.24% for middle level and 2.82 o C and 87.93% for base level in the empty cold storage. There isn t big differences between levels. Table 4: Mean values of ambient temperature and relative humidity for different levels Levels Mean temperature ( o C) Mean relative humidity (%) Top 2.82 87.86 Middle 2.81 88.24 Base 2.82 87.93 Table 5: Mean values of ambient temperature and relative humidity for Y axis Y Axis number Mean temperature ( o C) Mean relative humidity (%) Y-1 2.82 87.74 Y-2 2.83 88.42 Y-3 2.81 88.02 Y-4 2.80 87.84 The results show that mean ambient temperature and relative humidity changing for Y axis was not so big. It is good for cold storage of agricultural products because spatial variability of the ambient conditions will be small. 5. Conclusions The cold store with chiller was different than conventional cold stores which has evaporative cooling system. Conventional cold stores includes compressor, condenser and evaporator. The cold store used in this research has chiller unit and air distribution system into the cold store. The results showed that distribution of the 208

Akdemir S, 2017, 4(12):203-209 ambient temperature and relative humidity of the cold store with chiller unit was very good. If the results compare cold store with evaporative cooling system, ambient temperature of the cold store at 1 o C storage set up temperature was changed between 1.5 o C and 3.9 o C for evaporative cooling system, 2.80 o C - 2.83 o C for cold store with chiller unit. The relative humidity was changed between 81.1 % and 95 % for evaporative cooling system [11] and 87.43% -89.00& for cold store with chiller. All the results showed that distribution of the ambient temperature and relative humidity were less than the conventional cold stores which has evaporative cooling system Acknowledgements Authors would like to thank to TUBITAK for their support to TUBITAK Project No:110 O 147 - Investigation of Spatial variability effect of ambient conditions on storage losses, This manuscript was prepare from final report of the project. References [1]. Karaçalı, İ. (2009). Conservation and marketing of garden products. (7 th Edition). Ege University Agriculture Faculty Pub, 5 th Ed.,(486) [2]. Xie, J., Xiao-Hua Qu, A., Jun-Ye Shi, A., and Da-Wen, S. (2006). Effects of Design Parameters on Flow and Temperature Fields of a Cold Store by CFD Simulation. Journal of Food Engineering, 77(2): 355-363. [3]. Tanner, D.J., Cleland, A.C. and Robertson, T.R. (2002). A Generalised Mathematical Modelling Methodology for Design of Horticultural Food Packages Exposed to Refrigerated Conditions: Part 3, Mass Transfer Modelling And Testing. International Journal of Refrigeration, 25: 54 65. [4]. Akdemir, S., and Arin S. (2005). Effect of Air Velocity on Temperature in Experimental Cold Store. Journal of Applied Sciences, 5(1): 70-74. [5]. Becker, B. R., and Fricke, B. A. (2004). Heat Transfer Coefficients for Forced-Air Cooling and Freezing of Selected Foods. International Journal of Refrigeration, 27: 540 551. [6]. Brown, T., Janet, E.L. C., and Stephen, J. J. (2004). Humidification of Chilled Fruit and Vegetables on Retail Display Using an Ultrasonic Fogging System with Water/Air Ozonation. International Journal of Refrigeration, 27(8): 862-868. [7]. Hoang, M.L., Verboven, P. De Baerdemaeker., and J. Nicolaoe, B.M. (2000). Analysis of the Air Flow in a Cold Store by Means of Computational Fluid Dynamics. International Journal of Refrigeration, 23: 127-140. [8]. Moureha, J., and Flick, D.B. (2004). Airflow Pattern and Temperature Distribution in a Typical Refrigerated Truck Configuration Loaded with Pallets. International Journal of Refrigeration, 27: 464 474. [9]. Anonymyous., (2017). Testo 177H1 Datasheet, http://elcodis.com/parts/ 4018638/ 177H1.html# datasheet, access date: 18/12/2017) [10]. Soysal, M. I. (2007). Principles of biometry (in Turkish). Trakya University, Tekirdağ Faculty of Agriculture Pub. no:95, Lecture notes no:64 [11]. Akdemir, S., and Arin, S. (2006). Spatial Variability of Ambient Temperature, Relative Humidity and Air Velocity in a Cold Store. Journal of Central European Agriculture, 7 (1): 101-110 209