High Wall Duct-Free High Efficiency Single Zone

Similar documents
duct-free air conditioning systems Art cool inverter flex multi-split

MINI-SPLIT STANDARD CONDITIONERS SINGLE ZONE. Available styles

ART COOL MINI-SPLIT SINGLE ZONE. Neo Plasma. Outstanding air purification ART COOL. Customized good looks. Available styles and finishes

ENGiNEERiNG AND SPECiFiCATiONS GuiDE

HIGH WALL DUCTLESS MINI-SPLIT STANDARD SINGLE ZONE

ENGiNEERiNG AND SPECiFiCATioNS GuiDE

BENEFITS. Daikin North America LLC, 5151 San Felipe, Suite 500, Houston, TX, 77056

Ductless Split Systems Concealed Duct Heat Pumps

LG Electronics, HVAC Division 920 Sylvan Ave., Englewood Cliffs, NJ

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Ductless Split Systems Ceiling Cassette Heat Pumps

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

PRODUCT GUIDE Duct-Free Air Conditioning Systems Art Cool Mini-Split Flex Multi Split Floor Standing Ceiling Cassette Through-The-Wall PTAC PTHP

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

InverterFlex SerIeS InverterFlex Systems condition up to five rooms

LG Comfort Solutions. Comfort Solutions You Never Thought Possible

InverterFlex SERIES InverterFlex Systems condition up to five rooms

SINGLE-ZONE CEILING-CONCEALED DUCTED SYSTEM ENGINEERING MANUAL

Room Air Conditioner SVC MANUAL(Exploded View)

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.


MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

TECHNICAL SPECIFICATIONS

Specifications and Performance S2H

TECHNICAL SPECIFICATIONS

Single zone HIGH Efficiency

DUCTLESS MINI-SPLITS SINGLE-ZONE HYPERTEK MULTI-ZONE

SUBMITTAL DATA: MSZ-FH06NA & MUZ-FH06NA 6,000 BTU/H WALL-MOUNTED HEAT PUMP SYSTEM. Electrical Power Requirements. Indoor / Outdoor A 1 / 11

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Single - Zone Systems

MINI-SPLITS SINGLE-ZONE HYPERTEK MULTI-ZONE

Up to SEER 26.1 Wall Mount Heat Pump

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

SINGLE-ZONE HIGH EFFICIENCY WALL MOUNT ENGINEERING MANUAL

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

13 SEER CONDENSING UNITS & AIR HANDLERS

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Specifications, Performance & Submittal

LV Series. SEER 15+ Concealed Built in Heat Pump

DUCTLESS ROOM AIR CONDITIONERS

Feel the difference! Uncompromised Comfort Unrivaled Value C US. Mark of Superior Quality SERIES

Mini Splits Catalog SINGLE ZONE

FTQ. Daikin Inverter Ducted Heat Pump

SINGLE-ZONE ART COOL TM MIRROR WALL MOUNT ENGINEERING MANUAL

Thank you for selecting LENNOX air conditioners.

PTAC/PTHP. Packaged Terminal Air Conditioners and Heat Pumps. Residential & Light Commercial HVAC. Features: Performance:

TECHNICAL SPECIFICATIONS

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

THE WORLD S MOST EFFICIENT HEAT PUMP

Product Data Split System (R-410A) Air Handler for Multi Split Inverter System 9,000 to 24,000 BTU/Hr

DUCTLESS FULL LINE CATALOG

Condensing Units & Air Handlers

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

K sin. Mini Split Air Conditioners and Heat Pump

Technical Product Guide

Breeze A revolution in room cooling.

Model: Ceiling Cassette V 9k-24k

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

Single zone Art Cool Mirror

Whirlpool Split System 13 SEER Air Conditioner W2C3. Features

Product Data INDUSTRY LEADING FEATURES / BENEFITS

KE Series. SEER 14+ Wall Mount Heat Pump or Cooling Only

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

FBQ. DC Duct Heat Pump or Cooling Only

Samsung 360 Cassette, Single Zone, Split System

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems.

ADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW

WJH4 Product Specifications

manuflow AIR CONDITIONING & HEAT PUMP PRODUCTS SEER 17

Multi - Zone Systems. Specification and Performance. 208V-230V 18k-36k. Presents

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

PHD3. Product Specifications

Ruud Achiever Series Dedicated Horizontal Package Heat Pump

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

Packaged Terminal Air Conditioners

Well rounded. 360 CASSETTE. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting.

HEAT PUMPS. Efficient Comfort For Every Season

Lennox Mini-Split Systems Year-Round Comfort and Performance

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems.

Heating & Cooling Products

Air Conditioning & Heating. Ductless Product Catalog

TECHNICAL GUIDE MODELS: DCPM/DHPM PREMIUM SERIES DUCTLESS SINGLE-SPLIT AIR CONDITIONERS AND HEAT PUMPS 22 SEER 1 PHASE 3/4 THRU 3 NOMINAL TONS

Ductless Systems. Right product for the right application

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Transcription:

9,000 BTU/h Cooling 10,800 BTU/h Heating Interior Unit Includes: down to 14ºF (Cooling Mode) holder & holder hardware Condensate sensor connection - Model#: PQRCVSL0(QW) - Model#: ZLABGP01A (Low indoor coil and a 41 line set LS091HSV2 LSN091HSV2 LSU091HSV2 Capacity (BTU/h) 9,000 10,800 EER 13.3 SEER 20 HSPF 11.0 Air Circulation (CFM H/M/L) 335/272/212 Dehumidification (pts/hr) 2.6 Indoor H/M/L db(a)* 38/33/24 Outdoor db(a)* 45 W x H x D (inches) 34 13/16 x 11 1/4 x 8 1/4 Weight (lbs.) 22.1 W x H x D (inches) 30 5/16 x 21 1/2 x 11 5/16 Weight (lbs.) 77.2 30

11,200 BTU/h Cooling 13,300 BTU/h Heating down to 14ºF (Cooling Mode) Condensate sensor connection Interior Unit Includes: holder & holder hardware - Model#: PQRCVSL0(QW) - Model#: ZLABGP01A (Low Indoor coil and a 41 line set LS121HSV2 LSN121HSV2 LSU121HSV2 Capacity (BTU/h) 11,200 13,300 EER 12.5 SEER 20 HSPF 11.0 Air Circulation (CFM H/M/L) 353/272/212 Dehumidification (pts/hr) 3.0 Indoor H/M/L db(a)* 39/33/24 Outdoor db(a)* 45 W x H x D (inches) 34 13/16 x 11 1/4 x 8 1/4 Weight (lbs.) 22.1 W x H x D (inches) 30 5/16 x 21 1/2 x 11 5/16 Weight (lbs.) 77.2 31

18,200 BTU/h Cooling 22,000 BTU/h Heating Interior Unit Includes: - Model#: PMNFP14A0 (PI485 V-net interface) down to 14ºF (Cooling mode) holder & holder hardware Condensate sensor connection indoor coil and a 24.6' line set - Model#: PQRCVSL0(QW) - Model#: ZLABGP02A (Low LS181HSV2 LSN181HSV2 LSU181HSV2 Capacity (BTU/h) 18,200 22,000 EER 12.6 SEER 20.5 HSPF 9.7 Air Circulation (CFM H/M/L) 622/509/399 Dehumidification (pts/hr) 5.5 Indoor H/M/L db(a)* 45/40/35 Outdoor db(a)* 53 W x H x D (inches) 40 9/16 x 12 13/16 x 9 11/16 Weight (lbs.) 30.9 W x H x D (inches) 34 1/4 x 31 1/2 x 12 5/8 Weight (lbs.) 132.3 32

22,000 BTU/h Cooling 27,600 BTU/h Heating down to 14ºF (Cooling mode) - Model#: PQRCVSL0(QW) Condensate sensor connection - Model#: ZLABGP02A (Low Interior Unit Includes: - Model#: PMNFP14A0 (PI485 V-net interface) holder & holder hardware indoor coil and a 24.6' line set LS240HSV2 LSN240HSV2 LSU240HSV2 Capacity (BTU/h) 22,000 27,600 EER 12.5 SEER 18.9 HSPF 10.2 Air Circulation (CFM H/M/L) 742/629/424 4/Auto/Chaos Dehumidification (pts/hr) 6.0 Indoor H/M/L db(a)* 46/43/39 Outdoor db(a)* 54 W x H x D (inches) 47 5/8 x 13 5/8 x 8 1/16 Weight (lbs.) 33.1 W x H x D (inches) 34 1/4 x 31 1/2 x 12 5/8 Weight (lbs.) 141.1 33

Inverter & Refrigeration Quick Reference Specifications Type Model BTU/h Voltage Rated MCA* MOP** Zone Indoor Outdoor Amps Art Cool Mirror H/P LA090HSV2 9,000 230/208 230/208 8.5 10 15 H/P LA120HSV2 11,200 230/208 230/208 8.5 10 15 H/P LA180HSV2 18,200 230/208 230/208 17.0 19 30 H/P LA240HSV2 22,000 230/208 230/208 17.0 19 30 H/P LS091HSV2 9,000 230/208 230/208 8.1 10 15 H/P LS121HSV2 11,200 230/208 230/208 8.1 10 15 H/P LS181HSV2 18,200 230/208 230/208 15.4 19 30 H/P LS240HSV2 22,000 230/208 230/208 15.4 19 30 All equipment single phase. NOTE: All communication cable, including the power wiring cable size must comply with the applicable local and national code. *Minimum Circuit Ampacity **Maximum Overcurrent Protection Refrigerant Line Specifications*** Type Model BTU/h Pipe Size Additional Max. Pipe Max. Zone Liquid Suction Refrigerant Length Elevation Art Cool Mirror H/P LA090HSV2 9,000 1/4 3/8 0.22 oz./ft. 65 32 H/P LA120HSV2 11,200 1/4 3/8 0.22 oz./ft. 65 32 H/P LA180HSV2 18,200 3/8 5/8 0.38 oz./ft. 98 49 H/P LA240HSV2 22,000 3/8 5/8 0.38 oz./ft. 98 49 H/P LS091HSV2 9,000 1/4 3/8 0.22 oz./ft. 65 32 H/P LS121HSV2 11,200 1/4 3/8 0.22 oz./ft. 65 32 H/P LS181HSV2 18,200 3/8 5/8 0.38 oz./ft. 98 49 H/P LS240HSV2 22,000 3/8 5/8 0.38 oz./ft. 98 49 Please choose a proper wire size based on local and state code *** Each system is pre-charged with enough refrigerant to charge 24.6 ft. (41 ft. for LA090HSV2, LA120HSV2, LS091HSV2, LS121HSV2) of line and the interior unit. Wired Wall Thermostat for Inverter. (Applicable to LS307HV2, LS360HV2, LXXXXHSV2, LAXXXHVP and LSXXXHYV models only) PQRCVSL0 PQRCVSL0QW 34