Compact 4-way Cassette ( ) Type

Similar documents
Digital Inverter 4 series 8 & 10HP

SERVICE MANUAL/INTEGRATION

AIR-CONDITIONER SPLIT TYPE

SERVICE MANUAL SPLIT TYPE

SERVICE MANUAL SPLIT TYPE R410A <DIGITAL INVERTER> INDOOR UNIT RAV-SM562MUT-E FILE NO. A06-005

AIR-CONDITIONER SERVICE MANUAL SPLIT TYPE R410A OUTDOOR UNIT

4-Way Cassette type. Contents MMU-AP 2H2UL

SERVICE MANUAL MMU-AP0092H, MMU-AP0122H, MMU-AP0152H, MMU-AP0182H, MMU-AP0242H, MMU-AP0272H, MMU-AP0302H, MMU-AP0362H, MMU-AP0482H, MMU-AP0562H,

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE

AIR-CONDITIONER SPLIT TYPE

Ceiling type. Contents MMC-AP 1H2UL MMC-AP0181H2UL MMC-AP0361H2UL MMC-AP0421H2UL

Air to Water Heat Pump

RAV-SP180AT2-UL (2 HP) RAV-SP240AT2-UL (3 HP) RAV-SP300AT2-UL (4 HP) RAV-SP360AT2-UL (4, 5 HP) RAV-SP420AT2-UL (5 HP)

Air to Air Heat Exchanger

Air to Water Heat Pump

Engineering. Super Heat Recovery Multi System

SERVICE MANUAL AIR-CONDITIONER (SPLIT TYPE)

AIR-CONDITIONER TOSHIBA SERVICE MANUAL SPLIT TYPE, HEAT PUMP COOLING ONLY FILE NO. A Tel: Fax:

MiNi-SMMS WHEN COMMERCIAL MEETS RESIDENTIAL

LIGHT COMMERCIAL RANGE Inverter heat pumps suitable for both homes and commercial premises

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

AIR CONDITIONER (MULTI TYPE) SERVICE MANUAL

Index. Toshiba Solutions. Absolute comfort

AIR-CONDITIONER SERVICE MANUAL

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

SERVICE MANUAL AIR-CONDITIONER (SPLIT TYPE) RAV-SM1104AT8P-E (TR) RAV-SM1404AT8P-E (TR) RAV-SM1104AT8JP-E RAV-SM1404AT8JP-E

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TOSHIBA Carrier (UK) Ltd. LC DX Interface Installation manual ENGLISH. For commercial use. Model name:

SERVICE MANUAL MMU-AP0071MH MMU-AP0091MH MMU-AP0121MH MMU-AP0151MH MMU-AP0181MH. <Compact 4-Way Air Discharge Cassette Type> FILE NO.

AIR-CONDITIONER RAS-M10YKV-E, RAS-M13YKV-E / RAS-M18YAV-E RAS-M10YKCV-E, RAS-M13YKCV-E / RAS-M18YACV-E SERVICE MANUAL SPLIT TYPE R410A SUPPLEMENT

for Light Commercial Use

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

Super. Digital Inverter. Inverter Air Conditioning for Light Commercial Use

AIR-CONDITIONER SERVICE MANUAL (MULTI TYPE) R410A

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

Product Launch SHRMi

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

DESIGN & TECHNICAL MANUAL

Technical HandBook. Version

DESIGN & TECHNICAL MANUAL

MiNi-SMMS Design Manual HFC R-410A. Indoor unit. Outdoor unit

TABLE OF CONTENTS ERSQ-AAY1

DESIGN & TECHNICAL MANUAL

Simultaneous. Heating and Cooling Solution for Large Buildings. Air Conditioning for large buildings

AIR-CONDITIONER SPLIT TYPE

DESIGN & TECHNICAL MANUAL

RAS-10JKVP-E RAS-10JAVP-E RAS-13JKVP-E RAS-13JAVP-E

technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

Ceiling Cassettes PLH-3AKH1.UK PLH-3AKH.UK PLH-4AKHS1.UK PLH-4AKHS.UK PLH-5AKHS1.UK PLH-5AKHS.UK PLH-6AKHS1.UK PLH-6AKHS.UK

ASU18RLF ASU24RLF AOU18RLXFWH AOU24RLXFWH CONTENTS WALL MOUNTED TYPE ROOM AIR CONDITIONER FOR EXTRA LOW TEMP. DISTRICT

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Single Fan MiNi VRF Apartment Ready

Side blow VRF. Engineering Data Book. Outdoor units E Model name: MCY-MHP0404HT-E MCY-MHP0504HT-E MCY-MHP0604HT-E

ASU18RLF ASU24RLF AOU18RLXFW1 AOU24RLXFW1 SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE CONTENTS

DESIGN & TECHNICAL MANUAL

Air Conditioners. Technical Data FBQ-C

TECHNICAL DATA & SERVICE MANUAL

6. DUCT TYPE AR 60FUAK, AR 60UUAK

INVERTER DUCTED SYSTEMS

DESIGN & TECHNICAL MANUAL

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit

Please read this Installation Manual carefully before installing the. This Manual describes the installation method of the. You must also refer to the

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

MUH-24RV - MSH-30RV -

RAS-24UKHP-ES-1 / RAS-24UAH-ES-1 RAS-18UKHP-ES2 / RAS-18UAH-ES2 RAS-24UKP-ES-1 / RAS-24UA-ES-1 RAS-18UKP-ES2 / RAS-18UA-ES2

AIR-CONDITIONER SERVICE MANUAL UNDER CEILING / CONSOLE TYPE

Service Manual AIR TO WATER HEAT PUMP. Outdoor unit. Hydro unit

technical data air conditioning systems Indoor Units FBQ-C7VEB

TABLE OF CONTENTS RMXS-E8V1B

DESIGN & TECHNICAL MANUAL

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

ELECTRICAL QUANTITY WEIGHT (LB)

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Blending Commercial and Residential. MiNi VRF

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

FILE NO. SVM SERVICE MANUAL AIR CONDITIONER SPLIT WALL TYPE RAS-24NKHP-E / RAS-24NAH-E RAS-18NKPX-T / RAS-18N2AX-T RAS-24NKPX-T / RAS-24N2AX-T

RAS-M10GKCVP-E RAS-M13GKCVP-E RAS-M16GKCVP-E

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

SERVICE MANUAL AIR-CONDITIONER (SPLIT TYPE) RAV-SM564UTP-E (TR) RAV-SM804UTP-E (TR) RAV-SM1104UTP-E (TR) RAV-SM1404UTP-E (TR) RAV-SM1604UTP-E (TR)

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER

SERVICE MANUAL AIR-CONDITIONER (SPLIT TYPE) RAV-SM304ATP-E (TR) RAV-SM404ATP-E (TR) RAV-SM304ATJP-E RAV-SM404ATJP-E OUTDOOR UNIT <DIGITAL INVERTER>

PUHZ-SHW140YHA PUHZ-SHW230YKA

DESIGN & TECHNICAL MANUAL

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER

Service Manual AIR TO WATER HEAT PUMP. Outdoor unit. Hydro unit HWS-804XWHT6-E1(TR) HWS-1104H-E1(TR) HWS-804XWHM3-E1(TR) HWS-804H-E1(TR)

SERVICE MANUAL SPLIT TYPE RAS-10N3AV2-E1 RAS-B10N3KV2-E1 RAS-B13N3KV2-E1 RAS-B16N3KV2-E1 RAS-13N3AV2-E1 RAS-16N3AV2-E R410A. Indoor Unit Outdoor Unit

DESIGN & TECHNICAL MANUAL

AUXG18LRLB AUXG24LRLB UTG-UKYA-W AOYG18LBCA AOYG24LBCA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) CONTENTS

Transcription:

E08-0 Engineering Data Compact 4-way Cassette (600 600) Type Indoor Unit RAV-SM40MUT-E RAV-SM4MUT-E Outdoor Unit RAV-SP404AT-E RAV-SP44AT-E Contents. Specifications. Connecting pipe length and lift difference between indoor units vs. capacity correction value. Dimension 4. Wiring diagram. Refrigerant cycle diagram 6. Sensible capacity table 7. Part load performance 8. Air speed distribution 9. Sound characteristics (NC-Curve)

. Specifications -. Indooor unit (Compact 4-Way Cassette(600 600) Type) Seires SDI4 SDI4 Model Indoor unit RAV-SM40MUT-E RAV-SM4MUT-E Outdoor unit RAV-SP404AT-E RAV-SP44AT-E Cooling capacity (kw).6 4.0 Heating capacity (kw) 4.0 4. Power supply phase 0V (0-40V) 0Hz Running current (A).0-4.6.8 -. Power consumption (kw).00.9 Power factor (%) 90 9 Cooling EER.60.6 Energy efficiency class * A A Energy rating **.0 4. Electrical characteristics Running current (A) 4.79-4.9.67 -.0 Power consumption (kw) 0.97.6 Power factor (%) 9 9 Heating COP 4..88 Energy efficiency class * A A Energy rating **..0 Maximum current (A).00.00 Main unit Zinc hot dipping steel plate Appearance Ceiling panel Model RBC-UMPG(W)-E (Sold separately) Panel color Moon-white(Muncel.GY 9.0 / 0.) Height (mm) 68 68 Main unit Width (mm) 7 7 Depth (mm) 7 7 Outer dimension Height (mm) 7 7 Ceiling panel (Sold separately) Width (mm) 700 700 Depth (mm) 700 700 Main unit (kg) 7 7 Total weight Ceiling panel (Sold separately) (kg) Heat exchanger Finned tube Fan Turbo fan Turbo fan Fan unit Standard air flow H/M/L (m/min).0 / 9. / 7.8.0 / 9. / 7.8 Motor (W) 60 60 Air filter attached (long life) Controller (Sold Separately) RBC-AMTE, ASE,TCB-AXE Sound pressure level H/M/L (db A) 40 / 6 / 40 / 6 / Sound power level H/M/L (db A) / / 46 / / 46 Connecting pipe * EC standard **AS standard Gas side (mm).7.7 Liquid side (mm) 6.4 6.4 Drain port (mm) VP

-. Outdoor unit Model Serieas SDI4 SDI4 Outdoor unit RAV-SP404AT-E RAV-SP44AT-E phase 0V (0-40V) 0Hz Power supply 0Hz(Power exclusive to outdoor is required.) Type Hermetic compressor Compressor Motor (kw).. Pole 4 4 Refirigerant charged (kg).0.0 Refirigerant control Pulse motor valve Standard length (m) 7. 7. Max. total length (m) 0 0 Pipe Additional refrigerant chrge under long piping connection 0g/m(m to 0m) 0g/m(m to 0m) Outdoor lower (m) 0 0 Height difference Outdoor higher (m) 0 0 Height (mm) 0 0 Outer dimension Width (mm) 780 780 Depth (mm) 90 90 Appearance Silky shade (Muncel Y8.-0.) Total weight (kg) 40 40 Heat exchanger Finned tube Fan Propeller fan Fan unit Standard air flow (m/min) 40 40 Motor (W) 4 4 Gas side (mm).7.7 Connecting pipe Liquid side (mm) 6.4 6.4 Sound pressure level Cooling/Heating (db A) 4/47 4/47 Sound power level Cooling/Heating (db A) 6/64 6/64 Outside air temperature, cooling (C) 4 to - C Outside air temperature, Heating (C) to - C

. Connecting pipe length and lift difference between indoor units vs. capacity correction value -. RAV-SM40MUT-E Cooling Cooling performance Outdoor unit hight (m) 0 0 0-0 -0 - -0 - -0 00% 98% 97% 96% 9% 94% 0 0 0 0 Pipe length (m) RAV-SM4MUT-E Heating Heating performance Outdoor unit hight (m) 0 0 0 0 - -0 - -0 - -0 00% 9% 90% 8% 80% 7% 0 0 0 0 Pipe length (m) 4

Model name MMU-AP007MH MMU-AP009MH MMU-AP0MH MMU-AP0MH MMU-AP08MH 4-way air Discharge Cassete Type Arialbi0c0p4;TOSHIBA CARRIER CORPORATION. Dimension -. RAV-SM40MUT-E/RAV-SM4MUT-E Bottom face of ceiling For branch duct knockout square hole O/ 0 Bottom face of ceiling Electric parts box O/ 6 0 7 unit external dimension 0 9 70. Knockout for flesh air intake O/ 00 9 07 7 49 64 0. hanging bolt pitch 9 to 660 ceiling open dimension 700 Panel external dimension 68. 4. 64 4 Refrigerant pipe (Gas) O/.7 Refrigerant pipe (Liquid) O/ 6.4 97. 77 0 hanging bolt pitch 9 to 660 ceiling open dimension 700 Panel external dimension 4 0 6 4 48 O/ 6 90. 9. 9 0 6 4 4. 0. 68 70. 7 unit external dimension. Hanging bolt M0 or W/8 local arrange Drain discharge port Wiring connection port For branch duct knockout square hole O/ 0 8 4 0 Ceiling panel 7 Bottom face of ceiling (NOTE) As ABS is used for the drain discharge port of the main unit, the vinyl chloride paste cannot be used. Use the flexible hose (Band fix) included in the package. Indoor unit 00 Stand-up 87. or less Stand-up 80 or less 9 to 660 ceiling open dimension 9 to 660 ceiling open dimension Drain-up standing-up size 000 or more or more Bottom face of ceiling Check port ( 40) 000 or more 000 or more or more 00 Wired remote controller RBC-AMTE Simple wired remote controller RBC-ASE Wireless remote controller kit TCB-AXE Weekly timer application RBC-AMTE and RBC-EXWE Obustacle Space required for installation and servicing Note:All dimensions are in mm.

4. Wiring diagram 4-. RAV-SM40MUT-E/RAV-SM4MUT-E TA TCJ TC LM LM 4 4 4 4 4 4 FM FS CN4 (RED) CN (WHI) 4 4 CN (WHI) 4 4 CN4 (WHI) 4 4 CN68 (BLU) CN04 (YEL) CN7 (CHK) CN7 (DISP) CN0 (RED) Motor drive circuit CN04 (GRY) CN0 (BLK) CN80 (GRN) MCC-40 Power supply circuit Fuse F0 T.A 0V~ DC0V DCV DCV DC7V 4 4 (EXCT) CN7 (RED) Control P.C. Board for Indoor Unit RY 0 RY 0 Fuse F0 0V~ T6.A CN67 (BLK) + ~ ~ RED WHI BLK P0 BLK CN70 (WHI) CN66 (WHI) CN0 (WHI) 4 4 6 4 CN60 (WHI) CN (WHI) (FAN DRIVE) 6 4 Connection interface (option) CN6 (YEL) CN09 (YEL) CN (RED) 4 4 BLK B WHI A CN4 (BLU) P.C. Board CN40 (BLU) U U4 Terminal for central remote controller BLK WHI Adapter for Wireless Remote Controller BLK WHI CN00 (WHI) B A Wired Remote Controller DP NOTE FM : Fan motor TA : Indoor temp. sensor TC : Temp. sensor TCJ : Temp. sensor LM,LM : Louver motor DP : Drain pump motor FS : Float switch RY0 : Drain control relay Serial L N signal Single phase 0 to 40V 0Hz Indoor unit earth screw Outdoor unit earth screw Color Identification BLK : BLACK BLU : BLUE RED : RED GRY : GRAY PNK : PINK GRN : GREEN WHI : WHITE BRN : BROWN ORN : ORANGE YEL : YELLOW 6

. Refrigerant cycle diagram -. RAV-SM40MUT-E/RAV- SM4MUT-E RAV-SP404AT-E/RAV-SP44AT-E Indoor unit TCJ sensor TC sensor Air heat exchanger Outer diameter of refrigerant pipe Gas side ØA Liquid side ØB.7mm 6.4mm TS sensor TD sensor -step muffler Ø9.0 00L Refrigerant pipe at gas side Ø.7 Packet valve Packed valve Outer dia. ØA TO sensor Outdoor unit Refrigerant pipe at liquid side Ø6.4 Packet valve Min. m Packed valve Outer dia. ØB PMV (Pulse Motor Valve) (CAM-B0YGTF-) Strainer Max. 0m 4-way valve (STF-008Z) TE sensor Rotary compressor (DA0AF-0F) Muffler Ø9 L60 Heat exchanger Ø8 ripple, rows, 4 steps FP. flat fin Distributor R40A.0 kg Cooling Heating Cooling Heating Pressure (MPa) (kg/cm²g) Discharge Suction Pipe surface temperature ( ÆC) Indoor heat exchanger Outdoor heat exchanger Compressor revolutions per second (rps)* Indoor fan Indoor/Outdoor temp. conditions (DB/WB) ( C) Pd Ps Pd Ps (TD) (TS) (TC) (TE) Indoor Outdoor Standard.0 0.97.7 9.9 8 4 48 70 HIGH 7/9 / Overload.90.08 9.8.0 9 6 7 4 70 HIGH /4 4/ Low load.90 0.70 9.4 7. 48 7 0 0 LOW 8/. / Standard. 0.6.6 6. 87 40 97 HIGH 0/ 7/6 Overload.86 0.89 9. 9. 86 7 47 9 LOW 8/ 4/8 Low load.86 0. 9.0.6 69 4 98 HIGH / 0/(70%) * 4 poles are provided to this compressor. The compressor frequency (Hz) measured with a clamp meter is times of revolutions (rps) of the compressor. * For the details of the outdoor units during twin combination of a digital inverter and a super digital inverter, refer to page 4 (Digital Inverter) and also page 7 (Super Digital Inverter) of the Service Manual File No.A0-08. 7

6. Sensible capacity table 6-. Super Digital Inverter 4 Series Sensible Heat Capacity : RAV-SM***MUT-E unit size 40 outdoor air temp. CDB indoor air temp. 4.0CWB.0CWB 6.0CWB 7.0CWB 8.0CWB 9.0CWB 0.0CWB.0CWB 4.0CWB 0.0CDB.CDB.0CDB 4.CDB 6.0CDB 7.0CDB 8.0CDB 0.0CDB.0CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 0.0.4.7.6.8.7.0.9. 4.0. 4.. 4..4 4..6 4.7.8.0.4.7..8.7.0.8. 4.0. 4.. 4..4 4..6 4.7.7 4.0..7..8.7.9.8..9. 4.. 4.. 4.4. 4.6.7 6.0..7..8.7.9.8.0.9. 4.0. 4.. 4.4. 4.6.7 8.0..6..8.6.9.8.0.9. 4.0. 4.. 4.4. 4.6.6 0.0..6.4.7.6.9.7.0.9. 4.0. 4.. 4.. 4..6.0..6.4.7.6.9.7.0.8. 4.0. 4.. 4..4 4..6.0..6.4.7..8.7.9.8.0.9. 4.0. 4..4 4..6.0....7..8.6.9.8.0.9. 4.0. 4..4 4.4. 7.0....6..8.6.9.7.0.8..9. 4.. 4.4. 9.0....6.4.7..8.7.9.8.0.9. 4.. 4..4.0..4..6.4.7..8.6.9.7.0.8. 4.. 4..4.0.0.4....7.4.8.6.8.7.9.8.0 4.0. 4...0.0.4....6.4.7..8.6.9.7.0.9. 4.. 7.0.9...4..6..7.4.7..8.6.9.8. 4.0. 9.0.8..0.4....6.4.7..8.6.8.8.0.9. unit size 4 outdoor air temp. CDB indoor air temp. 4.0CWB.0CWB 6.0CWB 7.0CWB 8.0CWB 9.0CWB 0.0CWB.0CWB 4.0CWB 0.0CDB.CDB.0CDB 4.CDB 6.0CDB 7.0CDB 8.0CDB 0.0CDB.0CDB TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC 0.0.8.9 4.0.0 4.. 4.. 4.4.4 4.6. 4.7.6.0.8. 4.0.0.7.8.9.0 4.. 4.. 4.4.4 4.. 4.7.6 4.9.8. 4.0 4.0.7.8.9.0 4.. 4.. 4.4. 4..4 4.6. 4.9.8..9 6.0.7.8.9.0 4.. 4.. 4.4. 4..4 4.6. 4.9.7..9 8.0.7.8.8.9 4.0. 4.. 4.. 4.4.4 4.6. 4.8.7..9 0.0.6.8.8.9 4.0. 4.. 4.. 4.4.4 4.. 4.8.7.0.8.0.6.8.8.9 4.0.0 4.. 4.. 4.4.4 4..4 4.8.7.0.8.0.6.7.8.9.9.0 4.. 4.. 4.. 4..4 4.7.6.0.8.0..7.7.8.9.0 4.0. 4.. 4.. 4.4.4 4.7.6 4.9.7 7.0..7.7.8.9.9 4.0.0 4.. 4.. 4.4. 4.6. 4.8.7 9.0.4.6.6.8.8.9.9.0 4.. 4.. 4.. 4.6. 4.8.6.0.4.6.6.7.7.9.9.0 4.0. 4.. 4.. 4..4 4.7.6.0..6..7.7.8.8.9 4.0.0 4.. 4.. 4.4.4 4.6..0....6.6.8.8.9.9.0 4.0. 4.. 4.4. 4.6. 7.0...4.6.6.7.7.8.8.9.9.0 4.0. 4.. 4..4 9.0..4....7.6.8.7.9.8.9 4.0.0 4.. 4.4. TC:Total Capacity [kw] SHC:Sensible Heat Capacity [kw] 8

7. Part load performance 7-. Combination Indoor unit : RAV-SM40MUT-E Outdoor unit : RAV-SP404AT-E Cooling Heating Q W Q W MINIMUM 00 60 00 60 RATING 600 000 4000 970 Q : Capacity in W W : Power Consumption in W Cooling Outdoor temperature( C) 40 0 0 Heating Outdoor temperature( C) 0 0 7 0 - -7-0 - Load(%) 00 90 80 70 60 0 40 0 0 0 Q 40 080 740 400 00 70 40 40 40 40 W 070 90 780 660 40 40 90 90 90 90 Q 600 40 880 0 60 800 00 00 00 00 W 000 88 79 6 0 40 60 60 60 60 Q 70 70 000 60 0 870 60 60 60 60 W 90 790 670 60 460 70 0 0 0 0 Q 870 480 00 70 0 940 60 60 60 60 W 860 740 60 0 40 0 0 0 0 0 Q 970 70 80 780 80 990 60 60 60 60 W 800 680 80 490 400 0 90 90 90 90 Load(%) 00 90 80 70 60 0 40 0 0 0 Q 40 4800 470 740 00 670 40 000 000 000 W 0 000 880 760 640 0 40 40 40 40 Q 480 440 860 80 890 40 90 80 80 80 W 070 90 80 70 60 00 90 400 400 400 Q 480 940 00 070 60 90 70 640 640 640 W 00 900 780 680 70 470 70 80 80 80 Q 4000 600 00 800 400 000 600 00 00 00 W 970 860 70 60 0 40 0 60 60 60 Q 70 60 990 60 40 870 490 400 400 400 W 940 80 70 60 0 440 40 0 0 0 Q 40 00 680 40 00 670 40 0 0 0 W 890 790 690 600 0 40 0 0 0 0 Q 60 0 090 80 70 0 040 980 980 980 W 790 700 60 0 40 70 90 90 90 90 Q 60 0 090 80 70 0 040 980 980 980 W 790 700 60 0 40 70 90 90 90 90 Q 460 0 960 70 470 0 980 90 90 90 W 770 680 600 0 440 60 80 90 90 90 Q 0 00 800 70 0 0 900 840 840 840 W 740 60 70 490 40 40 70 70 70 70 Q 900 70 0 0 40 90 760 70 70 70 W 700 60 40 470 90 0 0 60 60 60 9

Combination Indoor unit : RAV-SM4MUT-E Outdoor unit : RAV-SP44AT-E Cooling Heating Q W Q W MINIMUM 00 60 00 60 RATING 4000 90 400 60 Q : Capacity in W W : Power Consumption in W Cooling Outdoor temperature( C) 40 0 0 Heating Outdoor temperature( C) 0 0 7 0 - -7-0 - Load(%) 00 90 80 70 60 0 40 0 0 0 Q 800 40 040 660 80 900 0 40 40 40 W 80 060 870 70 70 40 40 90 90 90 Q 4000 600 00 800 400 000 600 00 00 00 W 90 987 8 66 44 60 60 60 Q 460 70 0 90 00 080 670 60 60 60 W 00 90 70 60 490 80 90 0 0 0 Q 400 870 440 00 80 0 70 60 60 60 W 00 80 700 70 40 60 70 0 0 0 Q 440 970 0 090 60 0 760 60 60 60 W 90 780 60 0 40 0 0 90 90 90 Load(%) 00 90 80 70 60 0 40 0 0 0 Q 600 40 4800 400 600 000 400 000 000 000 W 0 90 040 890 740 60 470 40 40 40 Q 40 4880 440 800 60 70 70 80 80 80 W 80 0 980 840 690 70 440 400 400 400 Q 490 440 940 40 960 460 970 640 640 640 W 0 070 90 790 660 40 40 80 80 80 Q 400 400 600 0 700 0 800 00 00 00 W 60 00 890 760 60 0 400 60 60 60 Q 400 780 60 940 0 00 680 400 400 400 W 0 990 860 740 60 00 90 0 0 0 Q 760 90 00 60 60 880 00 0 0 0 W 070 940 80 700 80 480 70 0 0 0 Q 940 640 0 060 760 470 80 980 980 980 W 90 840 70 60 0 40 0 90 90 90 Q 940 640 0 060 760 470 80 980 980 980 W 90 840 70 60 0 40 0 90 90 90 Q 760 490 0 90 660 80 0 90 90 90 W 90 80 70 600 00 40 0 90 90 90 Q 0 80 00 770 0 70 00 840 840 840 W 880 780 680 80 480 400 00 70 70 70 Q 0 90 70 490 80 070 80 70 70 70 W 80 70 640 0 40 70 90 60 60 60 0

8. Air speed distribution 8-. RAV-SM40MUT-E/RAV-SM4MUT-E.9m 0.7m/s 0.m/s 0.m/s 0 4 m

9. Sound characteristics (NC-Curve) 9-. RAV-SM40MUT-E/RAV-SM4MUT-E Fan tap H M L Sound pressure level (db(a)) 40 0 70 Octave band sound pressure level (db) 60 0 40 0 0 0 Approximate threshold of hearing for continuous noise H M L NC-0 NC- 40 NC- 0 NC- 0 6 0 00 000 000 4000 8000 Octave band center frequency (Hz)

XXX. 008