Product Data FEATURES AND BENEFITS. QHF 50Hz Heat Pump Inverter Single Phase 2.5kW to 8.0kW

Similar documents
V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Installation Instructions

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Installation Instructions

Hi - Wall Split Systems 12K - 18K - 24K

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

Ducted inverter reverse cycle air conditioning

CAUTION DLFEHA. SERVICE MANUAL High Wall Ductless System Sizes 09 to 24

Installation Instructions

Installation Instructions

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

AURORA SERIES CHANGING THE GAME FOR WALL SPLIT AIR CONDITIONERS

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Service Manual. Multi Split Type Heat Pump Air Conditioners. Applied to: HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_HOS-21U11IM

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

Installation, Operation & Maintenance

Installation Instructions

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

CASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Multi Split Systems. Reverse Cycle, Inverter Air Conditioner. Exclusively distributed by

Service Manual CAUTION ! WARNING INTRODUCTION. 619PB High Wall Ductless System Sizes 09 to 36

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

Wall Split System Air Conditioning

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

DESIGN & TECHNICAL MANUAL

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

Installation Instructions

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Technology that works fast. Inverter Ducted Systems

WALL MOUNTED UNITS SDH W SDH W SDH W SDH W

Service Manual for TAS-18EHN, TAS-24EHN

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Before using your air conditioner, please read this manual carefully and keep it for future reference. ACDC12B

C&H NORDIC Commercial 4 SERVICE MANUAL

SUPER DC INVERTER MULTI TYPE INSTRUKCJA SERWISOWA

DUCTED. SYSTEMS Enhanced for superior comfort and smart energy management by AirTouch 3. fordanddoonan.com.au 1800 AIR CON

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

Inverter Ducted Air Conditioners

Slim Line Ceiling Concealed Ducted Split Systems. Medium Static Pressure. Ducted Split System Heat Pump

Service Manual CAUTION. 38MAQ Outdoor Unit Single Zone Ductless System Sizes 09 to 30 ! WARNING SAFETY CONSIDERATIONS

INVERTER DUCTED SYSTEMS

Q Series. Inverter Split Systems

Service Manual CAUTION

SERVICE MANUAL 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* Indoor unit.

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

PRODUCT LINE-UP Residential & Light Commercial air conditioners

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

HI-WALL SPLIT SYSTEMS

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL SPLIT WALL-MOUNTED TYPE MODELS MWCOHC30S/MRCOHC30AS MWCOHC36S/MRCOHC36AS

Technical Manual. Multi Split Trio Quattro DCI REFRIGERANT R410A HEAT PUMP

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Now with WiFi as standard Find out more at

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

SERVICE MANUAL Room Air Conditioner DC Inverter Multi Split Outdoor units

Inverter Ducted Air Conditioners

Installation Instructions

Submittal Data Sheet

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Product Data. 38MAQ Outdoor Unit Single Zone Ductless System Sizes 09 to 30 INDUSTRY LEADING FEATURES / BENEFITS

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Bosch Split-Type Ductless Air Conditioner / Heat Pump

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

DuctlessAire ES Series. Service Manual 2016 ABSSA-B4-1601

Service Manual CAUTION ! WARNING SAFETY CONSIDERATIONS INTRODUCTION. 38MA*R Outdoor Unit Single Zone Ductless System Sizes 09 to 36

CEILING type (60Hz) SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

FAN COILS wall mounted

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

TCL SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS

Product Brochure 2017

Compact design & easy maintenance

KSIN INVERTER SERIES Service Manual 2013

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL. KSIO MINI Split DC Inverter Air Conditioner. Model Numbers:

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

Westinghouse. Split System Inverter Series. Service Manual

Change for Life. Service Manual

Product Brochure Smart Power. Low Profile Ducted

Installation Instructions

Mission 3D Inverter Series

Just feel well. 2017/2018 Air conditioning

DESIGN & TECHNICAL MANUAL

TROUBLESHOOTING TROUBLESHOOTING. Indoor unit EEPROM parameter error. Indoor / outdoor units communication error. Zero-crossing signal detection error

TAC-09CHSA/*** TAC-12CHSA/*** TAC-18CHSA/*** TAC-24CHSA/*** SERVICE MANUAL WALL MOUNTED SPLIT-TYPEAIR CONDITIONERS. No.TE1307.

Table of Contents. Page. 1. Safety Precautions Specifications Product Features Maintenance and Disassembly...

Transcription:

0Hz Heat Pump Inverter Single Phase.kW to 8.0kW turn to the experts Product Data FEATURES AND BENEFITS AVAILABLE SIZES: Nominal capacity are available from.kw through 8.0kW to meet the needs of residential applications. CERTIFICATION: All models are registered with MEPS. ELECTRICAL RANGE Units offered in single phase 0V ~ 40V. ENVIRONMENTAL REFRIGERANT The uses R410a, the environmentally sound refrigerant that provides home owners with additional peace of mind because R410a has zero ozone--depletion potential. UNIT DESIGN: The copper tube(i-g), coated fin, enhanced sine wave, aluminum fin coil is designed for optimum heat transfer and corrosion protection. The sereis 0 Hz Split--System of inverter Heat Pumps are designed for quiet, reliable heating during the winter and cooling during the summer. These heat pump systems provide economy of operation through energy conservation when used with components designated by the manufacturer. The series recovers heat for indoor comfort from outdoor air during the heating season and, by automatically reversing the refrigerant system, remove indoor heat and excess humidity during the cooling season. SOUND SHIELD All ODU have compressor sound SHIELD for noise attenuation. OPERATING RANGE: Minimum outdoor operating ambient in cooling mode is -10 C, and maximum is 48 C. Minimum outdoor operating range for heating mode is -1 C, maximum is 4 C. HIDDEN DISPLAY The lights can be turned off by remote controller when the unit is running. -WAY DRAINAGE CONNECTION Both left and right sides of indoor unit are possible for drainage hose connection, easy for installation. LOUVER POSITION MEMORY When starting the unit again after shutting down, its louver will restore to the angle originally set by the user. 1

FEATURES AND BENEFITS ( CONT.) REFRIGERANT LEAKAGE DETECT (1)Only be active in cooling mode. ()If the refrigerant have leakage, the display area will show EC and AC will turn off. (3)The refrigerant leakage detect function can better prevent the compressor being damaged by refrigerant leakage or compressor overload. 8 HEATING (1)In heating operation, the preset temperature of the air conditioner can be as lower as 8, which keeps the room temperature steady at 8 and prevents household things freezing when the house is unoccupied for a long time in severe cold weather. ()This function can be memorized if the power fails. QUIET DESIGN Select SILENCE on remote controller to enter silence operation.(press the button for second). Indoor fan will run at super breeze, which can keep indoor in a very low noise level, make a comfortable feeling for sleep. FOLLOW ME ( 1) With this function, the room temperature sensor built in remote controller is activated and replaces the one in indoor unit. Then the air conditioner will regulate the room temperature based on the temperature around the remote controller, just like the air conditioner is following the user. ()Pressing the Follow me button on remote controller to active this function. Then the remote controller will send PCB the signal every three minutes. If the PCB doesn t receive the signal for 7 minutes or pressing Follow me button again, the follow me function will terminate. LOW AMBIENT COOLING The outdoor fan speed can be changed according to the condenser temperature and the AC can run smoothly under the temperature as low as -10. PRODUCT NUMBER NOMENCLATURE 4 / 38 Q H F 0 4 - IDU 38 - ODU Nominal Capacity Platform name H - Split and Wall Mounted K - Cooling only Q - Heat pump and cooling

PART NAMES Parts list Part No. Name of Part Qty 1 Indoor Unit 1 Mounting Screw A ST3.9x -C-H 1 3 Mounting Plate 4 Anchor Air Filter 1 6 Remote Control 1 7 Mounting Screw B ST.0x10 -C-H 1 8 Remote Control Holder 9 Outdoor Unit 1 Indoor 8 Outdoor 9 Display symbols OPERATION TIMER PERIOD SELECTION PREHEAT OR DEFROST IN PROGRESS SELECTED TEMPERATURE SELF-DIAGNOSTIC CODES 3

REMOTE CONTROLLER Buttuns 1. Temp Up / Temp Down Buttons. Mode Button 3. On/ Off Button 4. Horizontal Swing ( ) Button. Self Clean Button 6. Follow Me Button 7. Fan Button 8. Timer On( ) / Timer Off ( ) Buttons 9. Sleep Button 10. Turbo Button / Silence Button 11. LED Button / F. P Button NOTE: Vertical Swing ( ) are not available on this model. Remote control display 1. OPERATING MODE DISPLAY: Indicates the current operation mode AUTO, COOL, DRY, HEAT (heat pumps only), or FAN.. TRANSMISSION INDICATOR: Illuminates when remote control transmits signals to the indoor unit. 3. TEMPERATURE/TIMER DISPLAY: Temperature setting from 17 C to 30 C) or set times for the timer operation (0~4h) will be displayed. If FAN mode is selected, there will be no temperature displayed. 4. ON/OFF INDICATOR: This symbol appears when the unit is turned on by the remote control, and disappears when the unit is turned off.. FAN MODE DISPLAY: Indicates when fan mode is selected. 6. FAN SPEED DISPLAY: Indicates the set fan speed. Nothing is displayed when the mode is set to AUTO or DRY. 7. FOLLOW ME DISPLAY: This indicator will be displayed when the remote sensing function is activated. This option is not available in DRY and FAN modes. 8. TIMER DISPLAY: Indicates the timer settings. It displays TIMER ON when the auto--on time function is set, TIMER OFF when the auto--off time function is set, and TIMER ON OFF when both functions are set. 4

SPECIFICATION Model Number - System - Indoor - Outdoor Refrigerant Type Power Supply 30 3036 300 40 4036 400 380 38036 3800 R410A R410A R410A Volts-Phase-Hz 0-40V~, 1Ph, 0Hz 0-40V~, 1Ph, 0Hz 0-40V~, 1Ph, 0Hz Capacity - Rated (Range) Kw.0(1.~3.0) 3.60(1.40~4.40) 4.89(1.60~.30) Cooling Power Input - Rated (Range) Kw 0.61(0.30~1.1) 0.88(0.3~1.0) 1.44(0.40~1.80) Efficiency - Rated (Range) EER 4.10(3.00~4.0) 4.10(3.60~4.70) 3.40(.90~4.40) Operating Current (Range) A.8(1.4~.3) 3.9(1.6~.4) 6.4(1.8~8.0) Capacity - Rated (Range) Kw.70(1.10~4.00) 3.80(1.10~4.80).0(1.40~6.00) Heating Powr Input - Rated (Range) Kw 0.68(0.30~1.0) 0.9(0.30~1.60) 1.6(0.40~.00) Efficiency - Rated (Range) COP 4.00(.70~4.0) 4.00(3.10~4.60) 3.40(3.00~4.60) Operating Current (Range) A 3.1(1.3~6.7) 4.(1.3~7.1) 7.1(1.8~8.8) Dimension (WxDxH) mm 800x188x7 940x0x7 940x0x7 Net Weight kg 7. 9. 9. Cooling Airflow (Turbo/H/M/L) L/s 17/161/139/114 /03/17/16 /11/178/18 Indoor Unit Moisture Removal L/hr 0. 0.7 1.6 Cooling - (Sound Pressure) (H/M/L) - 1m dba (@spl) 41/37/33 44/41/38 44/41/38 Cooling Sound Power (H) Outdoor Unit Heating- (Sound Pressure) (H/M/L) - 1m dba (@spl) 41/37/33 44/41/38 44/41/38 Heating - (Sound Power) (H) dba (@swl) Dimension (WxDxH) mm 780x0x40 810x310x8 810x310x8 Net Weight kg 30.0 3.0 37.0 Compressor Type Rotary Rotary Rotary Fan Motor Output W 36 40 40 Cooling - (Sound Pressure) (H) at 1m distance dba (@spl) 6 7 Cooling Sound Power (H) 66 67 68 Cooling Usable Temperature Range 0 C -10~48-10~48-10~48 Heating Usable Temperature Range 0 C -1~4-1~4-1~4 Liquid Line Ø/Gas Line Ø mm/inch 6.3/9. / 1/4"/3/8" 6.3/1.7 / 1/4"/1/" 6.3/1.7 / 1/4"/1/" Pipe Size Coupler Style flaring flaring flaring Drain (Inside Diameter) Ø mm 16 16 16 Minimum Length m 3 3 3 Maximum Length m 0 0 Chargeless Length m Additional Refrigerant Gm / m 1 1 1

SPECIFICATION (CONT.) Model Number - System - Indoor - Outdoor Refrigerant Type Power Supply 3060 306 3080 4060 406 4080 38060 3806 38080 R410A R410A R410A Volts-Phase-Hz 0-40V~, 1Ph, 0Hz 0-40V~, 1Ph, 0Hz 0-40V~, 1Ph, 0Hz Capacity - Rated (Range) Kw.93(1.80~6.70) 6.30(1.8~6.90) 8.00(3.40~8.0) Cooling Power Input - Rated (Range) Kw 1.80(0.0~.40) 1.91(0.~.30).3(0.80~.70) Efficiency - Rated (Range) EER 3.30(.80~4.00) 3.30(3.00~3.90) 3.40(3.10~4.40) Operating Current (Range) A 7.9(.~10.) 8.6(.~10.3) 10.4(3.6~1.0) Capacity - Rated (Range) Kw 6.0(1.60~7.10) 7.40(1.70~7.60) 9.00(3.10~9.90) Heating Powr Input - Rated (Range) Kw 1.97(0.0~.0).4(0.0~.40).0(0.80~3.10) Efficiency - Rated (Range) COP 3.30(.90~4.0) 3.30(3.00~4.10) 3.60(3.0~4.80) Operating Current (Range) A 8.7(.~11.0) 9.8(.~10.) 11.1(3.6~13.8) Dimension (WxDxH) mm 104x3x31 104x3x31 160x83x363 Net Weight kg 13.0 13.0 19.0 Cooling Airflow (Turbo/H/M/L) L/s 333/319/67/36 333/319/67/36 389/37/300/6 Indoor Unit Moisture Removal L/hr 1.8 1.9.4 Cooling - (Sound Pressure) (H/M/L) - 1m dba (@spl) 0/4/4 1/46/4 1/4/39 Cooling Sound Power (H) 61 6 6 Outdoor Unit Heating- (Sound Pressure) (H/M/L) - 1m dba (@spl) 0/4/4 1/46/4 1/4/39 Heating - (Sound Power) (H) dba (@swl) 61 6 6 Dimension (WxDxH) mm 84x30x700 900x31x860 900x31x860 Net Weight kg 48.0 6. 60.0 Compressor Type Twin Rotary Twin Rotary Twin Rotary Fan Motor Output W 3 100 7 Cooling - (Sound Pressure) (H) at 1m distance dba (@spl) 61 6 61 Cooling Sound Power (H) 7 73 7 Cooling Usable Temperature Range 0 C -10~48-10~48-10~48 Heating Usable Temperature Range 0 C -1~4-1~4-1~4 Liquid Line Ø/Gas Line Ø mm/inch 9./1.9 / 3/8"//8" 9./1.9 / 3/8"//8" 9./1.9 / 3/8"//8" Pipe Size Coupler Style flaring flaring flaring Drain (Inside Diameter) Ø mm 16 16 16 Minimum Length m 3 3 3 Maximum Length m Chargeless Length m Additional Refrigerant Gm / m 30 30 30 6

HEAT PUMP HEATING PERFORMANCE 160% 140% 10% Vs Rating Capacity % 100% 80% 60% 40% 0 036 0% 0% -10-7 7 Condenser Coil Entering Air Temperature 10% 100% 80% Vs Rating Capacity % 60% 40% 0% 00 060 0% -10-7 7 Condenser Coil Entering Air Temperature 7

HEAT PUMP HEATING PERFORMANCE (CONT.) 10% 100% 80% Vs Rating Capacity % 60% 40% 0% 06 080 0% -10-7 7 Condenser Coil Entering Air Temperature Note: Test mode: High fan speed and free frequency, inside condition(d/w) 0.0 /1.0. 7.0 /6.0 is the rated heating test condition;.0 /1.0 is the defrost test condition. -7.0 /-8.0 is the minimum heating test condition from ISO standard; -10.0 /-11.0 is the minimum heating test condition from Carrier standard. PHYSICAL DATA UNIT SIZE/SERIES 0 036 00 060 06 080 SHIPPING WT (kg) OPERATING WT(kg) IDU IDU 10. 7. 13.0 9. 13.0 9. 18.0 13.0 18.0 13.0 6. 19.0 ODU ODU 3.0 30.0 37. 3.0 40.0 37.0.0 48.0 60. 6. 64.0 60.0 COMPRESSOR Rotary REFRIGERANT Type Control Puron (R410A) Capillary Charge (kg) 1.11 1. 1.60 1.9.10.43 FAN IDU Cross Type,Direct Drive ODU Propeller Type, Direct Drive MOTOR DRIVE IDU AC DC ODU DC AC DC 8

ELECTRICAL DATA MODEL VPH / OPERATING VOLTS* COMPRESSOR Max Min MODEL RLA INDOOR FAN MOTOR MODEL FLA OUTDOOR FAN MOTOR MODEL FLA MRC MAX FUSE** OR CKT BKR AMPS 0 ASN98DUFZ.3 RPG0E 00. WZDK36-38G-W 0. 11. 0 036 ASN98DUFZ.3 RPG8D 06. WZDK40-38G-W-1 0. 11. 0 00 0-40 / 1 64 187 DA130M1C-31FZ 3.9 RPG8D 06. WZDK40-38G-W-1 0. 1. 0 060 DA10S1C-0FZ 970. RPG4C 0.3 YDK3-6F 0. 14. 30 06 DA10S1C-0FZ 9. 70 RPG4C 03. YDK100-6T 073. 14. 30 080 DA0SC-30MT 8. 8 WZDK8-38G 046. WZDK7-38G 0.6 16. 0 30 * Permissible limits of the voltage range at which the unit will operate satisfactorily ** Time --- Delay fuse. FLA --- Full Load Amps MRC --- Maximum Running Current RLA --- RatedLoadAmps CONNECTION DIAGRAMS CONNECTING CABLE OUTDOOR TO INDOOR 0-40V~,1Ph,0Hz FIELD POWER SUPPLY GND W 1(L) (N) S GND W 1(L) (N) S L N Indoor Unit Power Supply 0-40V~/1Ph/0Hz Indoor Signal High Voltage Ground IDU TERMINAL BLOCK Power to Indoor Unit 0-40V~/1Ph/0Hz Indoor Signal High Voltage Main Power Supply 0-40V~/1Ph/0Hz ODU TERMINAL BLOCK Notes: 1. Do not use thermostat wire for any connection between indoor and outdoor units.. All connections between indoor and outdoor units must be as shown. The connections are sensitive to polarity and will result in a fault code. 9

UNITS INSTALLATION 0cm or more 10

4 4 B B 6 Air freshening filter(1) (used to install on Air filter) The holes for fixing anchors should be mm. C D Indoor unit outline Left rear side refrigerant pipe hole φ6 A Right rear side refrigerant pipe hole φ6 40 :(A:800, B:7, C:100, D:9) C D Indoor unit outline Left rear side refrigerant pipe hole φ6 A 4036 / 400: (A:940, B:7, C:110, D:100) Right rear side refrigerant pipe hole φ6 11

4 B C Installation plate D Indoor unit outline 1. Left rear side refrigerant pipe hole φ6 A 4060 / 406 : (A:104, B:31, C:93, D:163) Right rear side refrigerant pipe hole φ6 C 389 33 D Indoor unit outline B Left rear side refrigerant pipe hole φ6 A Right rear side refrigerant pipe hole φ6 4080: (A:19, B:36, C:17, D:7) IDU Dimension H W D Model W D H 40 800 188 7 4036 / 400 940 0 7 4060 / 406 104 3 31 4080 160 363 83 1

Model 380 38036 / 3800 38060 3806 / 38080 700x40x40 810x310x8 84x30x700 900x31x860 333 90 Wire cross section is depending on the rated (max) current which is indicated as below: 13

Model 0 / 036 00 060 / 06 080 Rated (max) current of appliance (A) 11. 1. 14. 16.0 Indoor Wire Connection 1.Lift the indoor unit front panel..remove the indoor unit electrical cover and cord clamp by loosening the screws. 3.Pass the connecting wires from the back of indoor unit and connect to the indoor terminal block. Outdoor Wire Connection 1. Remove the electrical cover and cord clamp by loosening the screws.. Connect wires to the outdoor terminal block by same sequence to indoor unit. Connection Diagrams Power supply from outdoor W 1 (N) S W 1 (N) S L N For all family Power supply 14

0039166 S INDOOR WIRING DIAGRAM M SWING MOTOR1 WHITE INDOOR UNIT JX1 OUTDOOR UNIT CN M SWING MOTOR 3() IN FAN C_ C_1 FAN CAPACITOR BOARD KEY BOARD 0037391399 BLACK/BLUE CN11 L-IN AC-N CN16 CN6 CN4 L-OUT RY1 3 P_1 CN14 CN8 CN9 PLASMA 1 3 BLUE BLACK OLP TEMP. SENSOR HEATER : ION CN 41 COMPRESSOR U V W EXPANSIVE VALVE 6() CN 36 CN 31 CN 30 CN 3 CN CN 1 CN 4 4-WAY BLUE BROWN CN13_1 CN13_ 3 4 MULTI-FUCTION CONTROL BOX CN10A 8 DISPLAY BOARD CN3(CN301) CN-KEY Wire Contoller ROOM TEMPERATURE SENSOR PIPE TEMPERATURE SENSOR RFMOD (Wi-Fi Contoller) BLACK : CN 1 CN 0 BLACK REACTOR R100(R003) CN 40 CN 4 : CN 3 W NOTE:Four-way valve is used in the Cooling & Heating unit only 1(L)(N) S L N POWER SUPPLY OUTDOOR FAN HEATER 1 HEATER : HEATER OUTDOOR WIRING DIAGRAM CN44 WIRING DIAGRAMS AMBIENT SENSOR (WHITE) DISCHARGE SENSOR M ~ HEAT EXCHANGER SENSOR (BLACK) U V W W (N) 1(L) S CN1_1CN1_ BLUE L N CN 3 Wiring diagram 4/380 4/38036 4/3800 1

AC FAN WIRING DIAGRAMS (CONT.) SWING MOTOR INDOOR WIRING DIAGRAM 00399104 M M M ELECTRONIC EXPANSIVE VALVE VERTICAL SWING MOTOR TO OXYGEN ENRICHMENT OR ANION GENERATOR (ELECTRONIC HEATER) RELAY ASSISTANT BOARD C_1 C_ CN1_COMP CN_COMP N.O. COM. 1 3 4 BLACK BLACK CT1 1 3 4 WHITE A CN14 LOW/HIGH : 1 3 4 CN11 1 3 4 CN10 WHITE ION CN_N3 CN_HEAT Or CN4 CN_N CN8 Or Or CN_N CN_ION 4 BLUE BROWN BLACK OUTDOOR WIRING DIAGRAM HIGH PRESSURE PROTECT 003819034 : LOW PRESSURE PROTECT BLUE OUTDOOR AMBIENT TEMPERATURE SENSOR CN17 CN18 CN6 CN4 M ~ CONDENSER TEMPERATURE SENSOR DISCHARGE SENSOR OUTDOOR FAN 3 () CN11 CN1 CompTop : T4 T3 N-OUT L-OUT CN7 MAIN BOARD ON(4) CN4 CN COM(3) RY CN9 PLASAM MAIN BOARD 3 CN1 ~ ~ CN1 INDOOR MOTOR MIRCO SWITCH 1 1 CN13 IPM BOARD CN8 WHITE CNL CN10 U V W CN CN3 CN CN_TIN CN_TO 1 3 4 6 7 8 CNN CN_S BLUE(BLACK) 1()3(4) 1()3(4) (4) CN30 L-IN N-IN CN3 CN4 GND P-1(P-) CN CN3 Notes: This symbol indicates the element is optional,the actual shape shall be prevail. BLUE BLACK FAN CAPACITOR HEAT CN9 CN8 HEAT1 CN6 CN 4-WAY CN1 CN 1 1 1 1 1 1 S BLUE BLUE W 1(L) (N) S INDOOR UNIT T1_room T_pipe TRANSFORMER REACTOR BOARD DISPLAY POWER BOARD BLUE HEATER HEATER1 4-WAY V(S) W(C) U(R) 1(L)(N) S L N W COMPRESSOR L N POWER SUPPLY Wiring diagram 4/38060 4/3806 16

WIRING DIAGRAMS (CONT.) Wiring diagram 4/38080 INDOOR WIRING DIAGRAM M S ROOM TEMPERATURE SENSOR PIPE TEMPERATURE SENSOR SWING MOTOR1 WHI T E BLUE(BLACK) INDOOR UNIT JX1 OUTDOOR UNIT M (10) SWING MOTOR 00389144 HEATER W (N) S 1(L) ION IN FAN M CN1_1 CN1_ CN6_1 CN4 P_1 CN CN14 CN6_ L-OUT L-IN N CN11(CN1) CN16 RY1 CN10A ( CN 10) MULTI-FUCTION CONTROL BOX 8(7) DISPLAY BOARD MICRO SWITCH PLASMA CN43 CN44 CN8 CN9 Wire Contoller DC FAN CT1 CN1 BLUE BLACK L-IN N-IN CN3 CN4 ELECTRONIC EXPANSIVE VALVE A CN7 CN17 N-OUT ON(4) RY COM(3) CN1 CompTop CN14 LOW/HIGH MAIN BOARD T4 T3 U V W GND P-1 DISCHARGE SENSOR 4 BLACK 003809093 OUTDOOR WIRING DIAGRAM CN1 LOW PRESSURE PROTECT HIGH PRESSURE PROTECT CN CN3 CN4 CN ~ ~ IPM BOARD BLUE BLUE BLUE L-OUT CN38 CN37 CN6 CN11 CN1 REACTOR V(S) W(C) U(R) COMPRESSOR CN39 BLUE 4-WAY CN1 CN HEAT1 CN6 CN HEAT CN9 CN8 CN18 S CN10 OUTDOOR AMBIENT TEMPERATURE SENSOR CONDENSER TEMPERATURE SENSOR BLUE 4-WAY HEATER1 HEATER NOTE: As the standby control needs, the cross section area of cable connected to W, 1(L), (N) must be selected to suit the maximum system current. The maximum system current is equal to thesum of indoor unit and outdoor unit rated current. W 1(L)(N) S L N L N POWER SUPPLY 17

TROUBLESHOOTING For ease of service, the systems are equipped with diagnostic code display LEDs on both the indoor and outdoor units. The outdoor diagnostic display is two LEDs (Red and Green) on the outdoor unit board and is limited to very few errors. The indoor diagnostic display is a combination of flashing LEDs on the display panel or the front of the unit. If possible, always check the diagnostic codes displayed on the indoor unit first. The diagnostic codes displayed in the indoor and outdoor units are listed in the tables below. Operation lamp Timer lamp Display LED STATUS 1 time X E0 Indoor unit EEPROM parameter error times X E1 Indoor / outdoor units communication error 3times X E Zero crossing signal detection error 4 times X E3 Indoor fan speed has been out of control times X E4 6times X E Open circuit or short circuit of indoor room temperature T1 sensor Open circuit or short circuit of evaporator coil temperature T sensor 7 times X EC Refrigerant Leakage Detection 1time O E0 Current overload protection times O F1 Open circuit or short circuit of outdoor ambient T4 temperature sensor 3times O F Open circuit or short circuit of condenser coil temperature T3 sensor 4times O F3 Open circuit or short circuit of compressor discharge T temperature sensor times O F4 Outdoor unit EEPROM parameter error 6 times O F Outdoor fan speed has been out of control 1times P0 IPM malfunction or IGBT over-strong current protection times P1 Over voltage or over low voltage protection 3times P High temperature protection of compressor top diagnosis and solution times P4 Inverter compressor drive error = Flashing, X = Off O = Light For additional diagnostic information, refer to the Service Manual 18