Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Similar documents
Excel-EN Conventional Fire Control Panel

Matrix2000 MEMBER OF BSIA. Installation and Operation Manual. Conventional Fire Alarm Panels 4-24 Zones. British Security Industry Association

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

KFP-CF Series Operation Manual

Technical Speci fications 220V AC 50Hz or 110V AC 60Hz Accessories operational voltage. 2x 12V / 7Ah sealed lead acid gel batteries

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

636 and 646 Keypads. User s Manual

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

Installation, Operating and Maintenance Manual

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

KM300 Carbon Monoxide Detection System Installation Manual

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

ViewMatrix. Software for Online Monitoring & Control of Matrix2000 Conventional Fire Alarm Panels. Version: 2.0 Revision: 0.1

Operation & Maintenance Manual

Booster Power Supply Manual

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Intelligent Security & Fire Ltd

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Intelligent Security & Fire Ltd

FEC403EN Installation Manual

System 800 Addressable Fire Detection & Alarm System

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

INSTRUCTION MANUAL PC255O

Fire Alarm Control Panel. System Maintenance and Log Book

Panel Functions & Indicators - Key to Icons General & Zone Fire LEDs ACCEPT SOUNDERS START/ STOP RESET BUZZER MUTE KEYSWITCH DELAY ON/OFF ITEM SELECT

INSTRUCTION MANUAL PC255O

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

AL600ULADA. NAC Power Extender. Installation Guide

USER MANUAL & MAINTENANCE GUIDE OG OO

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Control Panel User Guide

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

MODEL B2 INSTALLATION MANUAL

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

Application, Installation, Operation & Maintenance Manual

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

ZP2 Series Operation Manual

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

AL800ULADA. NAC Power Extender. Installation Guide

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

FEC400 Series. Installation Manual

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

RAM-208. Remote Multiplex Annunciator Panel. Wiring & Installation Installation Manual COMMON TROUBLE A.C. ON SIGNAL SILENCED BUZZER SILENCE

External Wireless Sounder

BSR Addressable Fire Detection control panel. Installation operation manual

The EN54 Part 2 and 4 Fire System

1X-F Series Installation Manual

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

VA301C CONTROLLER WITH BACnet OPTION

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

OPERATION AND INSTALLATION MANUAL

FW-RA-LED Remote Multiplex Annunciator Panels

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Installation Instructions 4 Zone Fire Panel

QA16 Addressable System

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

User Operation Manual

Conventional & Twin-wire Fire System

PRO-TEC SYSTEM ONE. Trailer Security Systems Model # PTS-2. Photo includes PTS-2 with optional pager unit

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Model 17A00 Expansion Enclosure

CONVENTIONAL CONTROL PANEL FL2/4/8/12 LT-XP

RAM-216. Remote Multiplex Annunciator Panel. Wiring & Installation Manual COMMON TROUBLE A.C. ON SIGNAL SILENCED BUZZER SILENCE SIGNAL SILENCE

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

Control/Communicator

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

Conventional Fire Alarm System 2014 V1.2

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

FIRE ALARM CONTROL PANEL FVC01-08

INSTALLATION INSTRUCTIONS

MR-2316-AT/Z Remote Annunciator

D2E Duct Smoke Detector

RP1r-Supra / VSN-RP1r+ / ESS-RP1r-Supra Extinguishing Control Panel User Manual. HLSI-MN-103I v.06 September 2017

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Fire Alarm Control Panel. Installation, Commissioning & Operating Manual

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

DH100ACDCI Ionization Air Duct Smoke Detector

FireNET Plus Wiring Instructions

RE 102 RE Fire Alarm Control Panel. Installation, Commissioning & Operating Manual

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

RELEASE DEVICE CONTROLS

Transcription:

Matrix2000 User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 s Version: 2.0 Revision: 1

IMPORTANT INFORMATION Limitation of liability It is mandatory, Matrix2000 panel to be installed in accordance with this manual, applicable codes, and the instructions of the Authority Having Jurisdiction. The manufacturer shall not under any circumstances be liable for any incidental or consequential damages arising from loss of property or other damages or losses owing to the failure of products beyond the cost of repair or replacement of any defective products. The manufacturer reserves the right to make product improvements and change product specifications at any time. The manufacturer assumes no responsibility for errors or omissions, while every precaution has been taken during the preparation of this manual to ensure the accuracy of its contents. Warranty Paradox Hellas warrants its products to be free from defects in materials and workmanship under normal use for a period of two (2) years (the Warranty Period ) from the production-delivery date, identified by date code(s) indicated on the products. Because Paradox Hellas does not install or connect the products and because the products may be used in conjunction with products not manufactured by Paradox Hellas, Paradox Hellas cannot guarantee the performance of the fire alarm system and shall not be responsible in any way whatsoever for faulty installation or connection. RoHS directive compliance The EC RoHS guideline has been released in order to reduce the heavy metal load in electrical and electronic products caused by e.g. lead and mercury. All manufacturers are obligated to provide only RoHS-compliant products to the European market, effective from July 1st, 2006. PARADOX FIRE hereby states that Matrix2000 panel is fully compliant with RoHS 2002/95/EC directive. Disposal of your old appliance 1. When this crossed-out wheeled bin symbol is attached to a product it means the product is covered by the European Directive 2002/96/EC. 2. All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities. 3. The correct disposal of your old appliance will help prevent potential negative consequences for the environment and human health. 4. For more detailed information about disposal of your old appliance, please contact your city office, waste disposal service or the shop where you purchased the product.

TABLE OF CONTENTS 1. General Description 4 2. Keyboard Indications and Controls 4 2.1 POWER Indication 4 2.1.1 Battery faults 5 2.2 System FAULT indication (General Fault) 5 2.3 Additional system fault indications 6 2.3.1 SIGNALING DEVICE fault 6 2.3.2 EARTH fault 6 2.3.3 AUX POWER Fault 6 2.4 Fault indications 6 2.5 System ALARM indication 7 2.6 s ALARM indications 7 3. Central Electric Keyswitch 8 4. Controls Via Keypad 9 4.1 System SILENCE button 9 4.2 System TEST button 9 4.3 System RESET button 9 4.4 s BYPASS buttons 9

1. General Description The Matrix2000 advanced analog fire alarm control panels have been designed to provide full fire detection coverage to buildings or installations that require fire detection systems of 4 to 24 zones. There are six (6) basic models for the Matrix2000 panel: Model s Common Relays M2004 4 2 M2008 8 2 M2012 12 2 M2016 16 2 M2020 20 2 M2024 24 2 Table 1. Matrix2000 panel models Operating Voltage 220-240 VAC / 50-60Hz or 110-120 VAC / 50-60Hz. Matrix2000 panel has the following optional components: - Expansion Board - Expansion Relay Board - Remote Annunciator The analytic indications and the simple controls of the Matrix2000 panel ensure the easy handling and controlling of the system by the operator. 2. Keyboard Indications and Controls Operating, monitoring and programming of the panel is performed in three different access levels. In access level 1 the panel controls are locked. Access to level 2 is achieved by the keyswitch on the face of the panel (Figure 1). Operations at access level 2 are performed with the keypad. Access level 3 operations are accomplished with the micro switches on the main circuit board of the panel. Figure 1. Matrix2000 keyboard 2.1 POWER Indication The POWER indication is permanently ON if the main power is present and batteries are healthy. This condition signifies normal system operation. POWER indicator OFF signifies a total power failure of the system. This can be due to a number of reasons. Some of them are: 4

Main power failure for an extended period of time during which the batteries have been depleted. Blown main board fuse. Other malfunction of the power supply, main board disconnected from PSU (power supply unit) etc. Blinking power indicator signifies one of the following: (a) Removal or power loss of the batteries. (b) Main power loss. (c) Blown main power fuse or PSU fuse. In the above cases, SYSTEM FAULT indicator turns ON and the on board buzzer sounds continuously. 2.1.1 Battery faults The Matrix2000 panel uses a battery fault detection system that will generate a battery fault indication in the following cases: Battery missing. Battery wiring open circuit. Battery not able to charge (low voltage). Battery wear (increased internal resistance of batteries). When the battery power is the only available source the supplied voltage is constantly checked. In the case that this voltage drops bellow the 21.7 VDC ±5% the panel enters a fault state with all zone fault indications activated. At the same time the power to the zone circuits is removed. This state is automatically reset once the mains power is restored. This mechanism ensures that the low voltage from depleted batteries will not cause the zone detection circuits giving false alarms. 2.2 System FAULT indication (General Fault) GENERAL FAULT, indicates a problem in the system. It turns ON in case of: wiring connection problems. Signalling devices output wiring problems. Relays outputs wiring problems (auxiliary relays MER4 or MER8). Auxiliary power faults. Earth fault condition. The above mentioned problems could be open circuits, shorts between wires or shorts between wires and earth. Consequently the Fault relay output is activated. At the same time there will be a continuous audible notification from the on board Buzzer. It is possible to silence the Buzzer by pressing the SILENCE key, with the keyswitch in position Control Enable. When the problems causing the indication are restored all the above indications will turn off automatically. Matrix2000 - Advanced Analog Fire Alarm Control Panel 5

2.3 Additional system fault indications In this group three distinct fault conditions are indicated: 2.3.1 SIGNALING DEVICE fault When active, this indicator signifies a fault condition of the signaling device output. The fault can be one of the following: Short circuit of the two output wires Open circuit in the connecting cable between the block connector and the signaling device. The signaling device must be terminated with a 4.7K Ohm resistor (EOL). Blown fuse that protects the system from shorts while the signalling device is in operation. 2.3.2 EARTH fault When active, this indicator signifies a short circuit between any of the panel s wiring (zones, relays, outputs etc.) and the building s earth is detected. The signaling device output wires are also monitored for the earth short condition. 2.3.3 AUX POWER Fault When active, this indicator signifies that an overcurrent condition at the auxiliary power output is detected. The maximum allowed current is 1 Amp. The device is capable of continuous operation even at full short circuit of this output; though any device powered from this output will stop functioning. If more than 1 Amp is required, a compatible EN 54-4 approved fire alarm power supply must be used. When such a power supply is used, the negative output of the extra power supply must be connected to the negative terminal of the AUX terminal (-AUX). 2.4 Fault indications The Fault indications will blink, in a different pattern, (Figure 2, page 7) depending on the type of the problem that occurs. In detail: (a) If a short-circuit or an opening of a zone is detected (See Table 2), System FAULT indication will turn ON, the corresponding s FAULT indication will blink as in Pattern A, (Figure 2, page 7) and at the same time there will be an audible notification from the on board Buzzer. Possible causes of a zone problem are: (a1) Disconnection or interruption of wiring of the zone. (a2) Short-circuit in the wiring of the zone. (a3) Removal of sensor from its base. (a4) Removal of the terminating resistor (EOL). (b) When a Relay expansion module is used the s FAULT indication is also triggered by: A short-circuit or opening of the wiring in the corresponding zone relay output (See Table 2). 6 Matrix2000 - Advanced Analog Fire Alarm Control Panel

Removal of the output terminating resistor (EOL). In case (b) as listed above the System FAULT indication will turn ON and the s FAULT indication of the corresponding zone will blink (Figure 2, Pattern b). At the same time there is also an audible notification from the on board Buzzer. (c) In the case that both of the above cases occurs, the LED indication starts blinking (Figure 2, Pattern c), while at the same time there is an audible notification from the on board Buzzer. Fault LED Indications Duration that LED is turned ON 1750msec Duration that LED is turned OFF Pattern A fault (short-circuit or open zone) 250msec Pattern B Expansion Relays Outputs Fault (short-circuit or open) 2sec 2sec Pattern C 500msec Fault + Relays Outputs Fault Time Figure 2. s Fault indications To silence the Buzzer, press the SILENCE button, with the keyswitch in position Control Enable. The System FAULT indication remains ON in order to show that a problem exists in the installation. The Buzzer sounds in regular time intervals, in order to remind the user the existence of the problem. All the indications will turn OFF automatically after all problems are restored. See page 11, RESPONDING TO TROUBLE SIGNALS. 2.5 System ALARM indication When the system detects a condition of fire (smoke, high temperature etc), the panel turns in Alarm Mode and the System ALARM indication turns ON. At the same time there is a continuous audible alarm from the sounder or sounders that are connected on the main board. System ALARM indication also turns ON when the evacuation of a protected area is required. It can be accomplished by turning the keyswitch in the Evacuate position. In both cases the indication is blinking when a s ALARM has occurred (Figure 3). In the above cases the on board buzzer will also sound. 2.6 s ALARM indications s ALARM indicators blink (Figure 3) each time a detector or a manual call point from the corresponding zone is triggered. Matrix2000 - Advanced Analog Fire Alarm Control Panel 7

When the call point and all smoke detectors are restored, the system will continue in Alarm Mode. To silence the Buzzer, press the SILENCE button, with the keyswitch in the Control Enable position. All indications will remain ON until the system RESET button is pressed. Keypad buttons are active only when the keyswitch is turned to the Control Enable position. Figure 3 shows the alarm LED indications when activated by detectors, manual call points and evacuation keyswitch. Alarm LED indications s in Alarm from detector or evacuation keyswitch Duration that LED is turned ON Duration that LED is turned OFF 250msec s in Alarm from manual call point (120 Ohm) 2 sec Figure 3. s Alarm indications Alarm LED indication will blink according to the main signalling device alarm output pattern. See page 11, RESPONDING TO ALARM SIGNALS. Time 3. Central Electric Keyswitch The electrical keyswitch allows the operation of the panel in access level 2 as well as the activation of the immediate evacuation (an access level 2 action). The central electric Keyswitch has three positions: 1 st position (Access Level 1) Normal: This is the Normal operation mode. The panel waits for alarm events or any faults that may develop in the installation. All buttons on the keypad are disabled. 2 nd position (Access Level 2) Control Enable: Alarm events and possible faults are detected, all buttons on the keypad are active and the system is controllable. For Normal operation the keyswitch must be in the 1 st position. 3 rd position (Access Level 2) Evacuate: After a small delay of approximately 2 seconds all the system zones turn into Alarm Evacuation Mode resulting in the activation of all signaling devices in the protected area. The sounder connected on the main board produces the selected Alarm sound. In case that MER relay module(s) is used, the extra relays are activated and connected sounders produce the selected Alarm sound. The system returns to standby mode by turning the key to the Control Enable position and pressing the system RESET button. The key from the Keyswitch can be removed only when the keyswitch is in the Normal position. 8 Matrix2000 - Advanced Analog Fire Alarm Control Panel

4. Controls Via Keypad Keypad buttons, are activated only when the key of the Keyswitch is set in the Control Enable position. 4.1 System SILENCE button Pressing the SILENCE button will cause any existing audible signal to stop. If a new event occurs, the silenced condition will be canceled and the appropriate devices will resound. 4.2 System TEST button By pressing the System TEST button all the visual indicators of the keypad turn ON, confirming that none of the LEDs are damaged. The condition is maintained for as long as the System TEST button is kept pressed. The buzzer and the main sounders are also active during the test. 4.3 System RESET button The System RESET button is used for resetting the system s zones in Standby mode after an alarm. 4.4 s BYPASS buttons (also called zone disablements) The s BYPASS buttons are used to prevent the corresponding zone from causing an alarm. Note that zone disablements must not be a permanent working condition and they must be used only as a temporary action. For example zone bypassing can be used in case of building maintenance or other activities that can trigger false alarms on the detectors. Bypassing a zone is achieved by positioning the keyswitch in the Control Enable position and then pressing the corresponding s BYPASS button. At the same time the indicator is turned ON. It only returns to normal operation by pressing the same button again (toggle action). If one of the s BYPASS button indicators is turned ON (yellow color) the corresponding zone is isolated and does not cause alarms. If an error occurs to a bypassed zone, the General FAULT indicator is activated but the system stays in silent mode. An alarm condition to a bypassed zone is recognized and indicated but do not activate the sounders. If any of the zones is in bypass state the buzzer sounds every 1 minute to remind the user of the existing disablement. Matrix2000 - Advanced Analog Fire Alarm Control Panel 9

Matrix2000 Fire Alarm Control Panel Operating Instructions RESPONDING TO ALARM SIGNALS 1. 2. 3. Evacuate the area. Notify the proper authorities immediately and state the nature and location of the emergency. Be prepared to provide directions to firefighters when they arrive. TO SILENCE ALARM NOTIFICATION SIG- NALS Alarm notification signals should not be silenced until after all occupants have been evacuated. 1. Turn the keyswitch of the keyboard to Control Enable and press the Silence button. The Silenced button turns ON and all audible notification circuits turn OFF. New alarm events turn the notification circuits back on. TO RETURN THE SYSTEM TO NORMAL AF- TER AN ALARM 1. Make sure all smoke detectors are free from smoke and all manual pull stations are reset 2. Turn the keyswitch of the keyboard to Control Enable. 3. Press Reset. TO PERFORM A LAMP TEST (panel and remote annunciators) 1. Press and hold the Test button. RESPONDING TO TROUBLE SIGNALS 1. Turn the keyswitch of the keyboard to Control Enable. 2. Silence the panel buzzer. 3. Investigate the cause of the trouble and notify the authorized service personnel immediately. TO SILENCE THE PANEL BUZZER 1. Press Panel Silence. The buzzer turns OFF. Any new events turn the buzzer back on. Trouble conditions not cleared resound the buzzer after a predetermined time. Trouble conditions may affect the panel s ability to provide early detection and indication of a fire. Clear trouble conditions immediately. Installed by Name: Company: Address: Phone: For service contact Company: Address: Phone: Acceptance Inspection by Date: DEVELOPED BY Korinthou 3, Metamorfosi 144 51 - Athens, Greece Αριθμός πιστοποίησης: GR11450Q Compliance Statement Matrix2000 panel is designed and manufactured so that it fulfils the requirements of CDP 89/106/ EEC directive and are certified to directive CDP 89/106/EEC and EN 54 Part 2 and 4,1998 Standards. 10 Matrix2000 - Advanced Analog Fire Alarm Control Panel

ZONES DESCRIPTION 1: 2: 3: 4: 5: 6: 7: 8: 9: 10: 11: 12: 13: 14: 15: 16: 17: 18: 19: 20: 21: 22: 23: 24: Matrix2000 - Advanced Analog Fire Alarm Control Panel 11

Document Part Number: MATRIX-UG01, CPD version 2.0, revision 1 - June 2011