Flues and chimney systems

Similar documents
Flues and chimney systems

Air Excellent AE45SC. Technical Datasheets

Air Excellent AE55SC. Technical Datasheets

The intelligent alternative for flue gas venting systems

Air Excellent. Straightforward, effective air distribution

Venting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4

INSTALLATION AND OPERATING INSTRUCTIONS TABLE OF CONTENTS IMPORTANT

Z-DENS Z-FLEX. Polypropylene Vent Systems for High Efficiency Condensing Appliances. Single Wall Rigid Flexible Liner Concentric

Single Wall Flue system. Installation manual WARNING. Installation Manual CoxDENS PPs MC-CG-105 EN_892054

Wall-hung boilers. Spare parts catalogue. ecotec plus

The New Remeha Quinta Pro Selection, Design and Installation of Flue Systems

200i. Vent/air manual. Installation instructions for vent and air piping. Also read and follow: 200i Boiler manual 200i Control manual

COMBINATION SOLUTION FOR COLLECTIVE FLUE, AIR VENTILATION AND EXHAUST

This document is a preview generated by EVS

DURAVENT POLYPRO VENTING PRODUCTS

TW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40

Direct Vent Training & Installation Instructions for Venting 40/50 gallon models Telescoping Vent Kit (standard)

CHAPTER 8 CHIMNEYS AND VENTS

PelletVent Multi-fuel venting system. UL 641.

TWIN - GAS. Concentric flue gas system for decorative gas fires.

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

NEW * for buildings 2-24 floors

ZC Kit AGP Pellet Insert

BDM Direct Vent systems are for use with direct vent gas fired appliances.

Technical Guidance CE Marking of Metal Chimneys and Flues

Chimney Renovation Kit

PowerVent. Installation manual (GB) English. Store this document in a safe place UK

GAS FR25 IR FRYERS. Grande Carte SPECIFICATIONS CONSTRUCTEUR. Part A: Technical characteristics Part B: Technical instructions for installation

Importance of a Draught Regulator

CHAPTER 8 CHIMNEYS AND VENTS

Irish Standard I.S. EN :2009

CHIMNEYS AND VENTS CHAPTER 8

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

D e s i g n e d t o b e d i f f e r e n t

Prextherm Rsw High efficiency steel pressurised boilers

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

GB162 Concentric Horizontal Vent Kit

JEREMIAS GROUP. CE MARK according to EN / 2.

PowerVent. Installation manual (GB) English. Store this document in a safe place UK

CI/SfB (57.5) November 2008

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING

GRINNELL Rapid Installation Pivot-Bolt

CQS POWER VENT. General. Venting Requirements. Venting Instructions PREEVA Indoor, Power-Vented Heater Model PDH

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

Free-standing chimneys Part 6: Steel liners Design and execution

Easy to assemble. Silicone gasket sealed. Laser-welded seams. Smooth joint connections. 360 Lock-Tab secure rotation

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

VAILLANT SPARE PART CATALOGUE

INDOOR INSTALLATION AND VENTING

This document is a preview generated by EVS

Z-DENS Polypropylene Vent Systems

COMMON VENTING SYSTEM SUBMITTAL SHEET

LEIHDC70SC - LEIHDC70BB LEIHDC70BC. Instructions Manual.

Thermo Scientific Round Top Hotplate Stirrers. Make safety and accuracy part of your routine

Z-VENT MODEL SVE SERIES III INSTALLATION AND MAINTENANCE INSTRUCTIONS

Skorstenar Utförandestandard för metallskorstenar

TONAdin triple-wall insulated chimney of round design. TONAtec plus air/flue chimney for all fuel types (specifically biogenic solid fuels)

CELEBRATING WARMTH. New products brochure 2015

This document is a preview generated by EVS

Gas Fired Humidifier. SKG Series Combustion Field Adjustment Instructions. SKG Combustion Field Adjustment Instructions

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

Expansion vessel in a solar installation. White paper

This document is a preview generated by EVS

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

MASTERTEMP HEATER REPLACEMENT PARTS

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

GOLD GV. Venting Supplement for 3 venting. Water Boiler Series 3 & 4

Fundamentals of Making Energy-Saving and Cost-Efficient Boiler Exhaust Systems Design Solutions and Applications

AEROLINE. fast easy reliable. The sophisticated connection technology for heat pumps

Installation and maintenance instructions

Direct Exhaust Venting Kit Instructions

9. Check condensate piping for sagging and/or leakage. Repair any sags or leaks before restoring power to the appliance.

P3HAFEX. System Description

MX 200. MX-200 Technical Specifications FEATURES:

COMMON VENT SYSTEM. Features and Benefits. Model Applicability

Vent and air piped through a side wall (concentric termination)

PUCCI S.r.l. COMPONENTS AND ACCESSORIES FOR GAS BOILERS 0051 CPD CPD 0081

POWER VENT. Standard Power Vent, Fan Type Unit Heaters: Standard Power Vent, Blower Type Unit Heaters: General WARNING WARNING. Model UDAP & Model APD

PowerVent Installation manual. English. Store this document in a safe place EN

Installation Instructions

Smoke extraction duct of sheet steel

SEPARATED COMBUSTION WARNING

GWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions

GB125 Concentric Vent

V201 INSTALLATION MANUAL & USER MANUAL

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

ULC S636 System. PolyPro. PolyPro Flex. Terminations

Installation, Operation and Service Manual

AMSCO STERILIZATION CONTAINER SYSTEM User s Guide

Global Pressure Sensitive Adhesives Market Study ( )

RS Chimney Fan for Solid Fuel Applications

MX 200. MX-200 Technical Specifications FEATURES:

Draft Controls. When to use a Draft Control

Installation Instructions

GAS FRYERS GRANDE CARTE MANUFACTURER S INSTRUCTIONS. Part A: Technical characteristics Part B: Installation instructions.

Transcription:

Flues and chimney systems Complete systems overview

CLV systems concentric Description 4 4 1 3 The concentric CLV system is a collective chimney system especially for apartment buildings. It brings combustion air to the boilers on each floor and evacuates the individual flue through one common flue duct. The PP rigid inner ducts are suitable for condensing gas and oil boilers with a maximum flue temperature of 10 C. The outer ducts are made of galvanized steel. The system has a H1 tightness class which enables operation with positive pressure. This reduces the required diameters compared to a negative pressure system. T-pieces with 1 or boiler connections (90 or 180 ) are available. Each T-piece contains a compensator to absorb the elongation and shrinking of the PP flue pipes due to temperature variations. A special ring in the T-piece ensures that condensate flows back to each individual boiler. This limits drying-out of boiler siphons which are out of operation. A telescopic pipe makes it easier to adjust the length to the height of the room. An optional inspection opening at the bottom guarantees an easy access. 1 3 4 Terminals/outlet parts page 36 In the chimney page 36 System support page 37 Boiler connection materials page 5 for concentric materials page 54 for single-wall materials 34 Ubbink Centrotherm Group

Technical details CE marking Temperature class Seals Pressure class of the system EN14471 T10 H1 T10 EPDM for flue pipe connections, silicon for air inlet side H1 (5.000 Pa) Diameters with cap [mm] 80/130, 110/160, 15/00, 160/50, 00/300 Installation types C4 Features and benefits For multiple boiler installation (positive-pressure) Room sealed (type C) operation Maximum number of boilers depending on national regulations Number of boilers per floor depending on installation of the various T-pieces Reduced diameter for the flue pipes Telescopic pipes for easy adjustment to room height Special ring in T-piece limits drying-out of boiler siphons Gas flue systems 35

CLV systems concentric 1 Terminals/outlet parts CLV Terminal In INOX or coated steel Coating colors; black or terracotta Flue pipe in UV-resistant PP Roof parts Roof tile for pitched roofs; in INOX Rain collar for pitched roofs; in INOX Fixing plate for chimneys In the chimney Extension pieces 500 mm 1000 mm Telescopic extension pieces Easy adjustment to room height Fixation with security clamp 36 Ubbink Centrotherm Group

CLV systems concentric In the chimney Floor connection pieces (T-pieces) 1 connection connections; 90 connections; 180 Special parts Inspection piece Bottom part; for siphon placement 3 System support System support Adjustable, 3 feet tripod Can be fixed to the floor Gas flue systems 37

Ubbink Netherlands www.ubbink.nl Ubbink Belgium www.ubbink.be Ubbink France www.ubbink.fr Ubbink Spain www.ubbink.es Ubbink United Kingdom www.ubbink.co.uk Centrotherm Germany www.centrotherm.com Centrotherm Italy www.centrotherm.it Centrotherm U.S.A. www.centrotherm.us.com Centrotherm China www.centrotherm-china.com www.ubbink-centrotherm.com 015 - Ubbink Centrotherm Group Content is subject to change without notice Availability and configurations may differ per country UCG-015-03-V01