Protective Cabinet STI-7534, STI-7535 and STI-7535AED

Similar documents
Exit Stopper. STI-6400 Series

Exit Stopper. STI-6400 Series

Addendum for STI-6406 with Dual Access Control

EPO STATION. EPO Station with push to activate, turn to reset button complete with a clear cover to help

Installation and ZONES: Operation Manual. Model: ON STI-34108

STI-1229-HAZ STI-1229HTR-HAZ STI-1229HTR240-HAZ

Installation and Operation Manual. Model: STI TRIGGERED OUTPUT PLUG 12VDC, 75mA, 3 SEC. EMBOSSED PROGRAMMING

Stopper Station Series SS-2008 Push Button Pneumatic Timer Button

Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9

Stopper II Heated Enclosure

Illuminated Stopper Station Push Button

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

INSTALLATION MANUAL SOUNDER MODELS RIALTO L LS X LSX TRIADE L LS QL QLS LIDO L X LS LSX

SP-4004 OPTICAL-ACOUSTIC OUTDOOR SIREN sp4004_en 03/13

Caliber Series LED Edgelit Exit Sign EXPORT AC Only or Emergency Operation READ AND FOLLOW ALL SAFETY INSTRUCTIONS

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Pilot devices Stacklights Signal beacons

Auto Dialer. Manual E-921APQ E-921GPQ

Stopper II SERIES ADA. We protect the things that protect you

Conventional Fire Alarm System 2014 V1.2

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

AED Alarm System Model Operations Manual

Smart Home Outdoor Siren

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

Wireless D.I.Y. Alarm Kit

CONTENTS NBM-06 Bell (6") Page 1

Product Catalog. For specs & details go to sti-usa.com 1

SPECIFICATIONS. Contents List

Conventional Fire Detection

Beacon 800 Gas Monitor Operator s Manual

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Wireless Keypads LKP(E)S8M Series

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Installation & Operations Manual

FW-SIREN2EXT -8/9F FW-SIREN2CP -8/9F

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

Product Catalog. For specs & details go to sti-usa.com 1

Alarm Tone Generator Model AG17

Gate Mount Pool Alarms

KUFO/SECO DUST COLLECTOR

No INSTALLATION INSTRUCTIONS m (7.6-3 ft.) Far area mirror Masking plate for far area Fixing rubber form

SIRENS PROGRAMMABLE MULTI-SOUND SIGNAL by Tomar Electronics

Go Smart. Go Wireless.

LA5579 Wireless Siren Operation Manual

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

4 & 8-POINT ANNUNCIATORS Instruction Manual

COMPANY PROFILE PROTECTING THE THINGS THAT PROTECT YOU

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

User s Information Guide R2A

SECURIT 700L USER MANUAL

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

HX-80NRAM. High Mount Outdoor Detector

DE5300 Delayed Egress System. General Information

LS800S Intruder Alarm System. Engineering Manual

Potter Wall Mount Select-A-Strobe

Industrial Horn & LED Strobe Warning System - 12V DC - Weatherproof - NEMA 4X - Class 1 Beacon


Xenex Conventional Fire Detection & Alarm System

STANDARD FEATURES SPECIFICATIONS

INSTRUCTION MANUAL FOR: WIRELESS SECURITY STARTER KIT MODEL NO: SWSKIT

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

Rack Mount Series Installation Guide

Installation and Operation Manual. Wireless Indoor Strobe

Movement Detector GJD 300

SENSIT HXG-2d Combustible Gas Detector

Wireless Internal Siren System Installation Guide

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

Remote Chexit Module (RCM) System. General Information

Installation & Programming Guide

Quick Start Guide. 4MP Vandal Dome Fixed Lens IP Camera O4D1

INTRODUCTION / TABLE OF CONTENTS

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR FEATURES INSTALLATION HINTS PARTS IDENTIFICATION

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

DS160/DS161 Request To Exit PIR sensors Installation Instructions

Installation Instructions

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

ETSA380MF SHOWN WARNING. shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.

1. Introduction. 2. Product overview

Quick Installation Manual LED 99-Zone Autodial Wireless Alarm System

INSTRUCTIONS FOR. Wireless Refrigerator Freezer Thermometer (#10378)

Sonic Boom Travel & Bed side Alarm Clock with Bed Shaker Model SB200ss-v3

Wireless Keypad GKP-S8M

Operator's Manual. LIGHTNING 2 Laser Detector

SA3. 6 Zone Wirefree Alarm System. Installation & Operating Manual 0 # ESC ENTER ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8

FOR MORE INFORMATION AND PRODUCTS, VISIT: USER MANUAL TO REMAIN IN VEHICLE

Premium 8 Zone Wireless Alarm Kit

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

Gas Safety Products. Installation, operating and maintenance 11/18/2015. Merlin 1000S+ Gas Utility & Electrical Isolation Controller

Sentry 4 Zone Alarm Panel User Manual

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Sentrol. ShatterPoint Glassbreak Sensor. Installation Instructions DESCRIPTION. Models (3 Volt) (6 Volt) STEP 1 MOUNTING

MODEL AV2-C1D1M Hazardous Duty Class I. Div 1, Multitone Alarm Station

Columbia Boat Alarms, Inc.

External Wireless Sounder

AXI LED USER MANUAL (REV. 1.0)

Combustible Gas and Hydrogen Sulfide Beacon 200 Rig Monitor Operator s Manual

Installation Instructions & Operating Manual IMPORTANT

Transcription:

Protective Cabinet STI-7534, STI-7535 and STI-7535AED Features Clear, protective polycarbonate cover with siren/strobe alarm. Design allows visibility at any angle. Complete with mounting hardware and gasket. Includes wire shelf, backing plate and siren/strobe alarm AED models External mounting tabs or internal drill dimples. Cover includes a coated steel internal mounting plate with a baked on white enamel finish. Siren/strobe alarm lens is red. Also available with amber, green, blue or white lens. Siren offers 32 user selectable tones. Alarm can be set for a piercing 100 db or 85 db. Independent strobe and siren timing of 15 seconds, 30 seconds, 60 seconds or continuous. Powered by a 9 VDC battery or external 12-30 volts. Low battery indicator. We protect the things that protect you.

CONTENTS Warnings...page 2 Cleaning Instructions...page 2 Dimensions...page 3 Specifications...page 3 Installation of Cabinet...page 4 Installation of Alarm...page 4 Alarm Electronic Setup...page 5 Alarm Tones...page 5 Alarm Timing and Volume...page 5 Alarm Terminal Strip Connections...page 6 Alarm Electronics Assembly...page 6 Assembly Parts List...page 7 Operation...page 7 Warranty...page 7 Accessories & Replacement Parts...page 8 WARNINGS All units are recommended for indoor use. Unit must be tested periodically to verify the life of battery. STI recommends you change the 9 Volt battery twice a year. When purchasing a siren/strobe alarm, you will need to periodically test the connections to make sure audibles function at a sound level to alert staff. Installer may need to purchase a simple audio-meter, typically available at your local electronics store, to measure the sound in areas where the alarm is expected to be heard during normal noise environment. Results from this test may prove it beneficial to purchase additional siren/strobe alarm units. All specifications and information shown are current as of publication and subject to change without notice. CLEANING 1. Rinse cover with water to remove abrasive dust and dirt. 2. Wash with soap or mild detergent using a soft cloth. (DO NOT SCRUB.) 3. Rinse once more, then dry with a soft cloth or chamois. 4. To remove grease or wet paint, rub gently with a cloth wetted thoroughly with naphtha, then wash and rinse. (DO NOT USE RAZOR BLADES.) 2

DIMENSIONS 23.5 in. (597mm) 14.2 in. (360mm) 12.2 in. (310mm) 16.5 in. (419mm) 1/4 DIAMETER FRONT VIEW 6.44 in. (164mm) BOTTOM VIEW SPECIFICATIONS OPERATING VOLTAGE Internal power 9 VDC battery (not included) Remote power 12-30 VDC OPERATING TEMPERATURE 32 F -120 POWER CONSUMPTION Stand by: 50µA Siren low volume: 85mA Siren high volume: 90mA Strobe: 25mA SIREN VOLUME Low: 85 db High: 100 db ALARM TIMING Independent control for siren and strobe: 15s, 30s, 60s, continuous LOW BATTERY WARNING LED flash once every 30 seconds FORM C DRY CONTACTS 0-30VAC/DC, 1 Amp RATED FOR Contacts reset after longest alarm setting KEY SWITCH Alarm on: normally closed ALARM SWITCH Stand by: normally open contact required POLYCARBONATE UL94V-2 FLAMMABILITY RATING 3

INSTALLATION OF CABINET Note: Installation of cabinet should be before installation of alarm because the mounting bracket butts up to cabinet. 1. Insert the (4) 06298 mounting tabs fully into backbox mounting tab slots. Use rubber mallet if necessary. 2. After selecting a suitable location, place cabinet in 19033 ANCHOR (4) PROVIDED STI-7530 KEYLOCK STI-7531 AND STI-7531AED THUMBLOCK 07530 CABINET ASSEMBLY INSTALLATION OF ALARM STEP 1 - MOUNTING OPTIONS 04875 MOUNTING PLATE PROVIDED MOUNTING TAB SLOTS 06298 MOUNTING TABS (4) PROVIDED 19013 SCREW #10 x 1 1/2 in. (4) PROVIDED 6297530 GASKET PROVIDED closed position, against the wall. Mark and drill (4) 1/4 in. diameter holes. Insert the (4) 19033 anchors. Mount cabinet by driving in the four #10 x 1 1/2 in. screws. 3. For STI-7531AED select one of the two shelf mounting locations, install shelf. Close and lock cabinet. TO KEY MOUNT PLATE OR INTO WALL WITHOUT ELECTRICAL BOX 19002 SCREW #8-32 x 3/8 in. (4) PROVIDED OPTIONAL SHELF MOUNTING POSITION 07530WR ADJUSTABLE SHELF INCLUDED WITH STI-7531AED ONLY DRILL 3-/16 DIA HOLES SUB-SA505 KEY SWITCH MOUNTING BRACKET 18074 SWITCH LOCK 18075 REPLACEMENT #801 KEY 3 9/32 in. BASE PLATE 19039 SCREW #6 x 1 1/4 in. (2) PROVIDED 19018 ANCHOR #8-10 (2) PROVIDED 4

STEP 2 - ELECTRONIC SETUP - SELECT ALARM TONE AND TIMING SEQUENCE S1 ALARM TONE LED QTY 10 LOW BATTERY INDICATOR LED SIREN BATTERY S2 ALARM TIMING STROBE TIMING VOLUME STEP 3 - ALARM TONES - S1 * TAMPER SWITCH (REAR VIEW) TERMINAL STRIP 1 0 0 0 0 0 BUZZ 2 1 0 0 0 0 SLOW ON/OFF 3 0 1 0 0 0 SLOW SIREN 4 1 1 0 0 0 3 BEEP/PAUSE/REPEAT 5 0 0 1 0 0 UFO FAST 6 1 0 1 0 0 FAST SIREN 7 0 1 1 0 0 #5 FAST 8 1 1 1 0 0 #2 MEDIUM 9 0 0 0 1 0 #5 MEDIUM 10 1 0 0 1 0 SWOOP MEDIUM 11 0 1 0 1 0 #3 MEDIUM 12 1 1 0 1 0 BUZZ TONE 13 0 0 1 1 0 STEADY FAST 14 1 0 1 1 0 SWOOP SLOW 15 0 1 1 1 0 CONTINUOUS 16 1 1 1 1 0 FAST REPEAT NOTE: 1 2 3 4 5 1 2 3 4 5 WIRE ENTRY BATTERY CABLE Select-Alert must be on a flat surface and lens must be installed or the tamper switch will trigger the alarm. 17 0 0 0 01 STANDARD ALARM 18 1 0 0 0 1 #3 FAST 19 0 1 0 0 1 #5 SLOW 20 1 1 0 0 1 FAST BEEP 21 0 0 1 0 1 SOUND A 22 1 0 1 0 1 SOUND B 23 0 1 1 0 1 SOUND C 24 1 1 1 0 1 SOUND D 25 0 0 0 1 1 SOUND D LOUD 26 1 0 0 1 1 SOUND E 27 0 1 0 1 1 SOUND F 28 1 1 0 1 1 SOUND G 29 0 0 1 1 1 SOUND H 30 1 0 1 1 1 #4 LOW 31 0 1 1 1 1 SOUND K 32 1 1 1 1 1 CONTINUOUS FAST WIRES TO SIREN NOTE: Sound may be disabled by clipping wires to the siren. THIS WILL VOID ALL WARRANTIES. Remove two screws on circuit board; leave enough length of wire to possibly reattach in the future. Then insulate wires to prevent shorting to electronic components. STEP 4 - ALARM TIMING AND VOLUME - S2 1 0 ON OFF ALARM TIMING 1 STROBE TIMING VOLUME 2 3 4 5 * ALARM SIREN STROBE VOLUME TIMING 1 2 3 4 5 15 seconds 1 1 1 1 High 30 seconds 1 0 1 0 1 60 seconds 0 1 0 1 Low Continuous 0 0 0 0 0 1 = ON 0 = OFF *Factory default settings 5

STEP 5 - ELECTRONICS ASSEMBLY Wiring: After mounting circuit board assembly, connect wires. Refer to terminal strip connections (step 6). Lens installation: Slide lip of lens behind circuit board mounting plate. Rotate lens into position. Secure with tamperproof screw and special wrench.! Unit will not operate properly if lens cover is not installed. ELECTRONICS INSTALLED BASE PLATE WIRE ACCESS HOLE ROUTE WIRES THRU HOLE 19002 SCREW #8-32 x 3/8 in. (4) PROVIDED 05050- LENS COLORS A - AMBER B - BLUE G - GREEN R - RED W - WHITE 19011 TAMPER-PROOF SCREW 19016 TAMPER-PROOF TOOL (1) PROVIDED STEP 6 - TERMINAL STRIP CONNECTIONS REMOTE POWER IN 12-24 VDC, 125mA (OPTIONAL) + - DC IN + - OFF ON MAIN POWER CONTROL TO KEY SWITCH KEY SWITCH ALARM SWITCH ACTIVE STAND BY REED SWITCH FROM CABINET NC COM NO COM FORM "C" DRY CONTACTS NORMALLY OPEN NORMALLY CLOSED NOTE: DC IN are the only polarity sensitive terminals. When external power is used, battery will act as a backup. Dry Contacts: NC, COM, NO are used for remote alarm monitoring. 6

ASSEMBLY PARTS LIST SIREN/STROBE ALARM QTY. PART # DESCRIPTION 1 05000 Electronics assembly (includes base plate & electronics assembly) 1 05050-R Red lens (unless otherwise specified) 1 09723 Key switch mounting bracket 2 18075 #801 key 1 18074 Switch lock 1 18151 N.C. reed switch and magnet (installed in cabinet) 4 19002 Screw #8-32 x 3/8 in. 2 19039 Screw #6 x 1 1/4 in. 2 19018 Anchor #8-10 1 19011 #8-32 x 1/2 in. tamper screw 1 19016 Tamper wrench 1 BAT-9VDC 9 volt battery CABINET 1 07530 Hinged polycarbonate enclosure 4 06298 Mounting tabs 4 19013 #10 x 1 1/2 in. screw 4 19033 Plastic anchor 1 07530WR Wire shelf (Included with AED models only) 1 04875 Mounting plate 4 19002 #8-32 x 3/8 in. screw 1 06297530 Gasket 1 07503 Thumb lock - STI-7535 models 1 18050 Key lock 2 18054 CH751 Key} STI-7534 models STEP 7 - OPERATION Turn key switch on to arm. Cycle key switch to reset alarm. Alarm will sound when cabinet is opened (alarm switch is electronically closed), alarm cover is removed or unit is removed from the wall. To service, turn key switch off. WARRANTY INFORMATION Three year guarantee against breakage of polycarbonate in normal use (one year on electro mechanical and electronic components). Electronic warranty form at www.sti-usa.com/wc14. 7

ACCESSORIES AND REPLACEMENT PARTS AED-LBL AED label - 2 included (applied to sides of cabinet; must be factory installed) STI-SA5000-R Replacement Siren/Strobe Alarm 18054 Replacement key for cabinet lock on STI-7534 18075 Replacement key for Siren/Strobe Alarm 07530WR Wire shelf (included with AED models) 2306 Airport Road Waterford, Michigan 48327-1209 Phone: 248-673-9898 Toll Free: 800-888-4784 Fax: 248-673-1246 www.sti-usa.com Safety Technology International (Europe) Ltd. Unit 49G Pipers Road Park Farm Industrial Estate Redditch Worcestershire B98 0HU England Tel: 44 (0) 1527 520 999 Fax: 44 (0) 1527 501 999 Freephone: 0800 085 1678 (UK only) E-mail: info@sti-europe.com Web: www.sti-europe.com Printed in USA SUBJECT TO CHANGE WITHOUT NOTICE Inst. Sht. STI-7535/STI-7535AED, JAN2014