TABLE OF CONTENTS. IMPORTANT Please read this manual carefully.

Similar documents
The guarantee on this appliance is valid for 12 months from the first day of installation.

End User Manual ACO 35 MFFI COMBI

SERIES. End User Manual ACO 27 MFFI G.C.N: ACO 32 MFFI G.C.N: ACO 27 RFFI G.C.N: ACO 32 RFFI G.C.

Servicing Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER

A/23 MFFI - A/27 MFFI

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

E-COMBI EVO E-SYSTEM EVO

24/30/38. E-Combi. CONDENSING WALL HUNG COMBINATION BOILER G.C.N : (24 kw) G.C.N : (30 kw) G.C.N : (38 kw)

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

Mynute. Standard efficiency system boiler 12e - 16e - 20e. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

GENUS HE GENUS HE 24 GENUS HE 30 GENUS HE 38. User Manual. Condensing wall hung system boiler

Vokèra OpenTherm 711 without external sensor connected

USERS GUIDE 24, 30. For installation guide see reverse of book

Vokèra OpenTherm 711 with external sensor connected

Installation Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER


USER GUIDE VOGUE MAX SYSTEM

USERS MANUAL FOR GAS BOILERS

Powermax HE 85, 115 & 150 Litre Condensing Boilers with Integrated Hot Water Storage

INSTRUCTION FOR THE USER THC V E OIL BLU

SINGLE-CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

Linea HE. High efficiency combi boiler. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

User Manual for model RK 18 RK 25 RK 34 CE 0694 RK 18_25_34 - RAD - ING - MAN.UT A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD

User Manual for model

Safety. DANGER Indicates potentially fatal situations. WARNING Indicates possible danger to life and limb.

MURELLE EV HE 25/55-30/55

USERS GUIDE. LOGIC+ Combi 24, 30, 35

Installation Instructions Type C Boilers G.C.N:

Logic+ Combi

Baxi Maxflow Combi WM

Supplied by HeatingSpares247.com

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

Installation Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS WITH THE END-USER

MAKING MODERN LIVING POSSIBLE. FP975 7-Day Electronic Programmer. User Guide. Danfoss Heating

Baxi Maxflow Combi FS

E-Combi One E-System ONE

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

3 Channel Multi-Purpose Programmer User Instructions

GB24 & GB30. User Manual

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

Planet Super4F.S. User Instructions

WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILERS. Efficient, economical and easy

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

USER MANUAL ACQUAHOME 32 B BLU

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

SPECIFICATIONS - NIKE

RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY

Mikrofill Ethos Condensing combination boiler

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

Elegance. SMT-700 User manual. Ver

User's Instructions. Alpha CB50

TWIN CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

ES3247B. 3 Channel Programmer. User and Installation Instructions

iheat 25c iheat 30c iheat 35c

AquaNova. Water heater. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

MAINTENANCE AND SERVICE GUIDE

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

SERIES. Installation and Servicing Instructions Type C Boilers ACO 35 MFFI G.C.N: LEAVE THESE INSTRUCTIONS WITH THE END USER

Installation, Servicing and Operating Instructions. Type C Boilers LEAVE THESE INSTRUCTIONS WITH THE END USER

R. Room temperature controller with solar control FR 120. Operating instructions for the user (2012/02)

TAHITI CONDENSING KR 55 - KR 85

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

User manual and Installation instructions

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

Installation, Start-Up, and Operating Instructions

Operating instructions

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

CentroPelet ZV14 TECHNICAL INSTRUCTIONS HEATING TECHNIQUE. for regulation, use and maintenance of pellet stove

Read all instructions before proceeding. Store this manual for future reference

Installation & User s Instructions

Pure technology. Clean design and practical panel board with wide Power save display !DEA AR 23 !DEA RS !DEA AC 23 !DEA CS

Operating instructions

Combi Eco Elite Range. User s Guide and Important Warranty Information

CONTROL CABINET for cascade boiler systems

CEM-24 Series. Owner's Manual - Installation and Operating Instructions

EUROSTER 2510 USER MANUAL 1 EUROSTER 2510

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

WHE 2.24 / WHE 2.24 FF

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Condensing. Installation Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS WITH THE END-USER

Digital Programmable

Installation and user manual

Safety & Installation Instructions

MAKING MODERN LIVING POSSIBLE. CP715Si. Electronic 2-Channel Common Timebase Programmer for Heating and Hot Water. User Guide.

Transcription:

User s Manual

TABLE OF CONTENTS 1) GENERAL INFORMATION page 5 2) OPERATING INSTRUCTIONS page 8 3) TIME CLOCK page 11 4) USEFUL INFORMATION AND TROUBLESHOOTING page 13 B003 IMPORTANT Please read this manual carefully. For additional information, please consult the Installation and Servicing Instructions. Please ensure manuals provided are kept with the appliance so that they can be used by the end-user, installer or our authorised engineer. 3

Dear Customer, Thank you for choosing an ARISTON boiler. We guarantee that your boiler is a reliable and technically sound product. This User s Manual provides detailed instructions and recommendations for proper installation, use and maintenance. Remember to keep this manual in a safe place for future reference i.e. by the gas meter. Your local MTS Servicing Centre is at your complete disposal for all requirements. MTS (GB) Limited The guarantee on this appliance is valid for 12 months from the first day of installation. Repairs to the electric, hydraulic or gas circuits may be carried out only by your local authorised MTS Servicing Centre. Every attempt has been made to avoid errors of any kind in this User s Manual, the Management invites customers to inform of any inaccuracies which they may find. This will help to improve our service 4 B003

TECHNICAL INFORMATION Genus 23 Genus 27 Genus 30 GENERAL DATA Heating input max Heating input min Heating output max Heating output min Efficiency at Maximum Thermal Capacity (see installation instructions) Efficiency at Reduced Thermal Capacity (see installation instructions) CENTRAL HEATING Operating Temperature max Operating Temperature min Maximum Heating Pressure Minimum Heating Pressure Built-in expansion vessel - Total capacity DOMESTIC HOT WATER* Maximum Temperature of Water for Domestic Use Minimum Temperature of Water for Domestic Use Working pressure max Working pressure min Flow rate T 25 C Flow rate T 35 C Minimum flow rate ELECTRICAL DATA Electrical Supply/Frequency Wattage Rating Protection of Electrical System CATEGORY Nominal Pressure/Methane Gas (G20) Nominal Pressure/Liquid Gas (G30-G31) kw(btu/h) kw(btu/h) kw(btu/h) kw(btu/h) % % C C bar bar litres C C bar bar l/min l/min l/min V/Hz W IP mbar mbar 25.6 (87364) 11.0 (37539) 23.1 (78491) 9.2 (31396) 90.2 87.8 82 42 3 1 7 56 36 6 0.2 13.2 9.4 2.6 230/50 150 X 4 D 20 30-37 29.8 (101707) 12.0 (40956) 27.1 (92492) 10.1 (34471) 91.6 88.3 82 42 3 1 7 56 36 6 0.2 15.6 11.2 2.6 230/50 150 X 4 D 20 30-37 33.0 (112629) 12.0 (40956) 30.3 (103414) 10.2 (34813) 92.0 88.6 82 42 3 1 7 56 36 6 0.2 17.3 12.4 2.6 230/50 150 X 4 D 20 30-37 * Combination versions only B003 5

Genus 23 MI Genus 27 RFFI SYSTEM Genus 23/27/30 MFFI LEGEND A) Ignition Lockout Reset Button/Safety (Overheat)Thermostat Reset B) Ignition Lockout L.E.D. C) Selector Knob for Summer/Winter/Flue Analysis Modes D) Low System Water Level L.E.D. E) Temperature Adjustment Knob for Domestic Hot Water F) Heating System Thermometer G) Safety (Overheat)Thermostat Intervention L.E.D. H) Adjustment Knob for Heating Temperature I) On/Off L.E.D. L) On/Off Switch N) Fume Sensor L.E.D. O) Heating System Pressure Gauge 6 B003

Installation, start-up, adjustments and maintenance must be performed by a competent person only in accordance with the Gas Safety (Installation & Use) Regulations (1984) and the instructions provided. Improper installation may cause damage or injury to individuals, animals and personal property, for which the manufacturer will not be held liable. To ensure efficient and safe operation it is recommended that the boiler is serviced annually by a competent person. If it is known or suspected that a fault exits on the appliance, it must not be used until fault has been corrected by a competent person B003 HELPFUL SUGGESTIONS To get the most out of your boiler, we have provided you with some useful advice on the proper use and O maintenance: - Periodically check the system pressure using the pressure guage O, make sure that the pressure is between 1.0 and 1.5 bar (the blue part on the gauge) when the system is off and cool. The warning L.E.D. D will indicate if the pressure is below the minimum recommended value. Consult your installer for checking and refilling the system. - The outer panels of the unit's case must only be cleaned with a damp cloth. Do not use abrasive cleaners. The Control panel can be wiped with either a damp or dry cloth. Spray polishes must not be used on the control panel surface or knobs. Care must be taken in preventing any liquid entering the appliance. - If the water is exceptionally hard, install a water softener so that the efficiency of the unit remains the same over time, as this will consume less gas. - To improve comfort and take full advantage of the heat produced by the boiler, it is recommended that an external thermostat be installed. - If the boiler is not going to be used for an extended period of time, turn off the supply of electricity to the unit by pressing the On/Off switch L. The green L.E.D. I will turn off. Then turn off the supply of gas to the unit itself. I - It is good practice to clean and service the appliance and central heating system every year. L Call an Authorised Service Centre. 7

START-UP PROCEDURE LIGHTING L (FOR ALL MODELS ) Before starting the unit, check the following: The water pressure on the pressure gauge O ; That the gas cock and the inlet for domestic water are open. These models are equipped with electronic ignition which utilises contact ionisation. To make the boiler operational, simply press the On/Off switch L. The green L.E.D. I will then turn on. At this point the boiler is ready for use: a centralised electronic control unit will automatically light the main burner when needed. If the burner does not light within B the pre-set safety time limit, the red B L.E.D. will light up. To reset the ignition system, the reset button A must be pressed. Should the system fail to light a A second time, check to make sure that the gas cock is open. If the problem persists, contact one of our Authorised Service Centres for assistance. I WINTER AND SUMMER OPERATING MODES (FOR ALL MODELS) The boiler is fitted with a selector knob C which C allows you to switch between winter < > and summer < > operating modes and vice versa. When the knob is set to < >, the boiler can serve the dual purpose of providing heat and/or hot water for domestic use. The supply of hot water for domestic use always takes precedence over heating. When the knob is set to < >, the boiler cuts out the heating system and only provides hot water for domestic use (when needed). 8 B003

TURNING ON THE BOILER Installation without a room thermostat : - Turn on the power supply to the boiler by pressing the On/Off switch L ; the green L.E.D. I will then turn on; - Turn the C selector knob to < >; - Regulate the temperature of the water in the boiler by turning the H knob. The temperature can vary between 42 C and about 82 C; I L C Installation with a room thermostat: - Turn the C selector knob to < >; H - Turn on the power supply to the boiler by pressing the On/Off switch L ; the green L.E.D. will then turn on; - Turn the thermostat knob H to the highest temperature setting. - With this type of installation, the boiler is controlled by a room thermostat. Therefore, it runs until the ambient temperature has reached the temperature setting on the thermostat. At that point, the main burner will turn off and the circulation pump will stop. - Check the boiler temperature on the thermometer with the yellow L.E.D.s F. With this type of installation, the ambient temperature does not influence the operation of the boiler and the circulation pump always remains in operation. F H TURNING OFF THE BOILER Installation without a room thermostat: To turn off the heating, turn the C selector knob to < >. The boiler will still provide hot water for domestic use. I L B003 9

ADJUSTING THE HEATING TEMPERATURE To economise on consumption while achieving the highest level of comfort, the temperature adjustment knob is designed with three different heating zones based on the temperature outside the home. Rotate the knob H as shown below. F H PRODUCTION OF HOT WATER FOR DOMESTIC USE E (FOR ALL MODELS) - Turn on the power to the boiler by pressing the On/Off switch L ; - With these settings, the boiler is already ready for use, regardless of the position of the C selector knob. - Turn the E knob to select the temperature for the hot water (between 36 C and about 56 C depending on the flow rate of the water). ADJUSTING THE TEMPERATURE OF WATER FOR DOMESTIC USE (FOR ALL MODELS) It is recommended that the temperature for the hot water should not be set to high temperatures and then mixed with cold water. Setting the thermostat to medium temperatures is preferable (see figure). E 10 B003

B003 SHUTDOWN PROCEDURE (FOR ALL MODELS) To turn off the main burner, simply press the On/Off switch L ; the green L.E.D. I will also turn off. As a precautionary measure, it is recommended that the gas cock located on the bottom of the boiler be turned off as well. TIME CLOCK The steps marked with the symbol are necessary to carry out a switching program. PREPARING FOR OPERATION Activate the Reset switch to reset the time switch to it s default settings (activate using a pencil or similar pointed instrument). Do this: - every time you wish to Reset the time switch; - to erase all switching times and the current time of day I L After approximately two seconds the following display appears: Input time Enter switching time Summer and winter time setting Weekdays blinks Reset Enter weekdays Enter minutes Enter the hour Manual switch ENTER CURRENT TIME AND WEEKDAY Keep the key pressed down. During the summer time period press the +/-1h key once. Enter the hour using the h key. Enter the minutes using the m key. Enter the day using the Day key. 1 = Mon... 7 = Sun Release the key. 11

The colon now blinks once a second. AM/PM TIME DISPLAY If you press the +/-h and h keys at the same time, the time display switches into the AM/PM mode. Notes: If you keep the h and m keys pressed down for more than 2 seconds, the display will enter fast forward scroll mode. ENTERING THE SWITCHING TIMES If your entry is incomplete, the segments not yet selected will blink in the display. You have 20 memory locations available. Each switching time takes up one memory location. Keep pressing the Prog key until a free memory location is shown in the display -- : --. Program ON or OFF with the key: = ON - = OFF. Enter the hour using h ; enter the minutes using m. If a switching command is to be carried out every day (1 2 3 4 5 6 7) then store using the key, otherwise select the days it is to be carried out on by using the Day key. When the day selection is left blank, the programmed switching instruction operates at the same time every day. 1 2 3 4 5 6 7 Monday... Sunday 1 2 3 4 5 6 Monday... Saturday 1 2 3 4 5 Monday... Friday 1 2 3 4 5 6 7 Saturday... Sunday 1 Monday... (selection of single days) 7 Sunday Store using the key or push Prog key if you are going to continue programming. The time switch enters the automatic operating mode and displays the current time of day. Begin any further entry of a switching time with the Prog switch. If necessary, once you have finished programming and have returned to the current time display, by pressing the button, the timer will not automatically switch to the current programmed status until the next timed setting. You can put the timer into the correct mode with the key. 12 B003

ADDITIONAL FUNCTIONS Switching from summer time to winter and vice versa. Press the +/-1h key once. MANUAL OVERRIDE KEY With the key you can change the current switching settings at any time. The switching program already entered is not altered. Automatic Operation Manual Operation Continuous Operation [ ] READING THE PROGRAMMED SWITCHING TIMES Pressing the Prog key displays the programmed switching times until the first free memory location appears in the display -- : --. If you now press the Prog key once again, the number of free memory locations will be displayed, e.g. Fr 20. If all memory locations are occupied, the display Fr 00 appears. = ON = OFF = ON = OFF = ON = OFF The switching times correspond to the program entered. If the current switching mode is changed manually, the next switching time will be carried out automatically again according to the entered switching program. You can only return to automatic mode from the continuously ON and continously OFF switching modes by pressing the key. CHANGING THE PROGRAMMED SWITCHING TIMES Press the Prog key repeatedly until the switching time you want to change is displayed. You can now enter the new data. See Entering the switching times. B003 13

Notes on storing switching times: If you end your entry of the switching times by pressing the Prog key, the switching time you have entered will be stored and the next memory location displayed. Entry of further switching times is also carried out as described in Entering the switching times. TECHNICAL DATA Ambient temperature: - 10 C to + 55 C Running reserve: 5 h (not for 1,5 V DC) Memory locations: 20 Shortest switching time: 1 minute Programmable: Every minute In addition, a complete switching command is stored automatically after around 90 seconds provided no other key is pressed. The time switch then enters the automatic operating mode and displays the current time again. DELETING INDIVIDUAL SWITCHING TIMES Press the Prog key repeatedly until the switching time you wish to delete is shown in the display. Then set to -- using the h or m key and keep the key pressed down for around 3 seconds. The switching time is now erased and the current time is displayed. 14 B003

USEFUL INFORMATION AND TROUBLESHOOTING BOILER SHUTDOWN The boiler unit is equipped with safety devices which intervene in certain situations to shutdown the boiler. Some of these situations are signalled by the unit and can be corrected by the user. SHUTDOWN DUE TO THE FAILURE OF THE BURNER TO LIGHT AUTOMATICALLY SHUTDOWN DUE TO OVERHEATING This anomaly is signalled by the red G L.E.D. The boiler shuts off because the safety thermostat detected that the boiler temperature has reached the temperature limit. To reset the unit, wait until the boiler has cooled and then press the A button. If the safety thermostat shuts off the unit on a frequent basis, contact one of our Authorised Service Centres for assistance. A G This anomaly is indicated by the red B L.E.D. To reset the unit, press and then release the A button. At this point, the electronic ignition system will attempt to light the burner again. If lighting failure occurs repeatedly, it is recommended that you contact one of our Authorised Service Centres. B A B003 15

SHUTDOWN DUE TO INSUFFICIENT WATER CIRCULATION FLUE TEST FEATURE (only for authorised personnel) This anomaly is indicated by the red D L.E.D. One of the possible causes of this shutdown situation could be the lack of water in the boiler or water circulation failure in the primary heating circuit. Check the system pressure on the pressure gauge O and, if it is less than 0.5 bar, consult your installer for checking and refilling the system. Then reset the unit by turning the boiler off and then back on with the On/Off button L. If this situation persists, contact one of our Authorised Service Centres. O I D The C Summer/Winter/Flue Test selector knob can be set to < > to bypass temperature adjustment on the C heating circuit for the purpose of analysing the fumes produced by combustion. To access this mode, open a water tap or taps so that the flow rate is no less than 8 litres per minute. Then press the C selector knob in and turn it from < > or < > to the < >. WARNING! The flue test feature eliminates the slow-light feature. This mode must only be selected by a qualified service engineer. L 16 B003

MONITORING DEVICE FOR FUME DISCHARGE (For Genus 23 MI) These units are equipped with a device that monitors the discharge of the fumes produced by combustion and automatically shuts off the supply of gas to the main burner for approximately 12 minutes if it detects that the fumes have been discharged into the room where the unit is installed. The shutdown of the unit is immediately signalled by the yellow "N" L.E.D. which remains on for the entire shutdown period. N This period lasts approximately 12 minutes, after which time the unit automatically resets to normal operation mode. IMPORTANT! In the event this safety device shuts off the system a number of times in succession, it is recommended that the unit be turned off and one of our Authorised Service Centres be contacted to inspect both the unit and the room to determine whether there is proper ventilation and discharge of the combustion fumes. B003 17

NOTES NOTES 18 B003

Manufacturer: Merloni TermoSanitari SpA - Italy Commercial subsidiary: MTS (GB) LIMITED MTS Building Hughenden Avenue, High Wycombe Bucks HP13 5FT Telephone: (01494) 755600 - Fax: (01494) 459775 Technical Service Hotline: (01494) 539579 Cod. 23 99 84 1256 111 / B003 - bieffe RECANATI