THERMOSTAT i-basic 3 USER MANUAL Rev.100

Similar documents
Two-Position Electric Duplex Room Thermostats

ROOF TOP TYPE UNITS CENTRIFUGAL FANS ENGINEERING DATA MANUAL MODELS Rev. 100

BHW INSTALLATION, OPERATION AND MAINTENANCE MANUAL MEDIUM STATIC PRESSURE DUCTABLE TYPE. Models:

NON-PROGRAMMABLE THERMOSTAT «ETN»

Dual Technology Wall Switch Occupancy Sensor. Manual & Specification

L. Terminal block Connecting Label:

Touch Screen Thermostat. MTSC/SUPER, MTSC24/SUPER Series. MTS/SUPER, MTS24/SUPER Series. Owner s manual and technician settings

Heat Link. Technical Guide

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

TIREE FAN COIL CONTROLLER - T6580

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

ONX908PIT-V1-S1-F1/B Modulating Digital Thermostat

air systems Roomtop RTC-RTH 15 to 30 - L

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Touch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue

OPERATING INSTRUCTIONS

Across-the-Line SERIES MP300 Combined Manual and Automatic

EUROSTER 2510TX USER MANUAL EUROSTER 2510TX

TECHNICAL CATALOGUE SELF-CONTAINED VERTICAL UNITS AIR / AIR DC INVERTER

Model A1600 Series Annunciator

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

GreenCon On/Off Room Thermostat

M15051) INSTRUCTION MANUAL

T7984 A,B,C Electronic Modulating Control Thermostats

Soft Start Series MP700 Solid State, Reduced Voltage

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

FEATURES AND BENEFITS

READ AND SAVE THESE INSTALLATION INSTRUCTIONS

ROOM THERMOSTATS KNX BASIC DOCUMENTATION

Variable Frequency Drive SERIES MP800 VFD

Model: RT310. Installation Manual

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

1040 Gas Monitor INSTALLATION AND OPERATING INSTRUCTIONS AMC-1040 WITH INTEGRAL ELECTROCHEMICAL SENSOR

Installation Instructions

Installation, Start-Up, and Operating Instructions

T6580 FAN COIL CONTROLLER

AURATON 2005 / 2005 TX

Application Manual Loop Water Controller

Schneider Electric Erie T155 Series

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Pump Logic User Manual CB-1000 P/N ILK-CB1000-1

Table 1. Serie of Digital Room Thermostats.

ARATON 2100 TX 1 AURATON 2100 TX. Advanced Remote Control Programmable Thermostat

Cat No. 099A. Digital Programmable Thermostat for Weekday/Weekend Setting. User Maunal

T105 Advanced Remote Control Programmable Thermostat. User Manual

T6984 A,D,E Electronic Floating Control Thermostats

Wall-mounted room thermostat with LCD

SAS908WHB-3-RF/B WIRELESS THERMOSTAT

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

air systems Large Rooftop DIC-BIH-DIG 360 to 480 G

Installation, Service, and Troubleshooting Instructions

MD12-1 Vehicle Loop Detector

Networkable Fan Coil Controller Specification and Installation Instructions

GreenCon On/Off Room Thermostat

Catalogue 2015 AHU N Range: VENTUS VS 10 - VS 650

Model 4880 Status Output Display Module Manual

Instruction manual. WMCR-2, WMCR-3, WMCR-4 and WMCR-6 Circulator Zone Controllers WMCR-1E and WMCR-4E Expansion Modules

TEC Controller Unit Conditioner - Two-Pipe Fan Coil Cooling or Heating, Application Application Note Building Technologies

T6865 Series Large LCD Digital Thermostat 24 VAC 2-pipe fan coil control

Application Data ! WARNING FACTORY INSTALLED SMOKE DETECTORS FOR SMALL AND MEDIUM ROOFTOP UNITS 2TO25TONS TABLE OF CONTENTS PART NUMBERS

INTELLICOMFORT CH180WIFI TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION FOR REMOTE CONTROL

AVPTC. Air Handlers 1½ to 5 Tons

DXM2 Digital Heat Pump Controller

INSTRUCTIONS REHAU SILENT DIAL THERMOSTAT #

PROGRAMMABLE 7-DAY RF THERMOSTAT

RC300 IntelliFire Plus Multifunction Remote Control Installation & Operating Instructions

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM

T6590 Series FAN-COIL CONTROLLER

24 VAC Direct Spark Gas Ignition

TEC Controller Terminal Box Controller (VAV) - with Hot Water Reheat, Application Application Note Building Technologies

Floor heating controls, wire connection 1

EHW KH PF HIGH EFFICIENTY AIR CONDITONING UNITS TECHNICAL CATALOGUE

! "! # Please read these installation and operating instructions completely and carefully before starting.

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

Feature Summary. I. System

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Product Manual SZ1145

Room thermostats for fan-coils, 3 speeds + automatic

LCF Touch Modbus Datasheet Application Security Advice Caution

ADC150 Automatic Draft Control

TEC Controller Terminal Box Controller (VAV) - Series Fan Powered with Hot Water Reheat, Application Application Note

OPERATION MANUAL. ComfortSense 3000 Series Model No. L3011C Non-Programmable Thermostat. Table of Contents. L3011C Thermostat

BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

DXM CONTROLS. DXM Digital Heat Pump Controllers. Application, Operation, & Maintenance. Table of Contents

T6590 Series FAN-COIL CONTROLLER FEATURES APPLICATIONS PRODUCT DATA

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

Service Manual ES50LVS / ES90LVS MULTI-SPEED AIR HANDLER. Ecosmartair 105 Haist Avenue, Unit 10 Vaughan, ON L4L 5V ecosmartair.

PumpSaver ISS-105 IS Super Cell Installation Guide

Siemens Thermostats. RDY2000BN Thermostat

T-32-TS Touchscreen Thermostat. Installation Manual

RCS Residential Control Systems Inc.

C37. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C37. User's Guide. Installer's Guide *VI7CE602* *087R8070* *087R8070* *VI7CE602*

Transponder reader TECHNICAL SHEET (White) (Magnesium)

CXM/DXM. Application, Operation & Maintenance Instructions 97B0003N08 Revision: 01/10/05. CXM/DXM Digital Heat Pump Controllers.

USER'S MANUAL AURATON 1300

Product Manual SZ1144

Transcription:

USER MANUAL

Thank you for trusting the Hitecsa Products. Our company has been offering the market an extended range of specialized units for air conditioning and cooling installations for over 35 years. Our approach is based on efficiency, adaptability, usability and practical solutions. This has been the hallmark of our product catalogue. The versatility of our factory allows us to contribute solutions, almost tailored to each project s specifications, in search of a solution to every problem that arises in design and implementation of air conditioning installations. From all of us at Hiplus Aire Acondicionado, once again, thank you very much.

ÍNDICE... 4 MAIN FUNCTIONS... 4 Installation... 4 APPLICATIONS... 4 OPERATION... 4 I-BASIC 3... 5 SIMPLIFIED INTERNAL DIAGRAM... 5 WIRES COLOR FOR ON BOARD INSTALLATION... 6 Electrical diagrams... 7 Electronic control... 9 On board installation... 11 Wall installation... 11 DIP-Switch function (back of the thermostat)... 12 Led function... 13 3

Electronic thermostat for fan coil MAIN FUNCTIONS - Room temperature adjustment - Manual or automatic Heating/Cooling selection - Manual and automatic 3 speed setting - Programmability through micro switch of the functions: destratification, fan mode, system type (2/4 pipes), electrical heater mode, neutral zone value. Installation - Wall-mounted (surface mounting with centres for box 503) - Directly on the fan coil (only AIR units) - Power supply 230 Vac 50 Hz - Output: 1A 230 Vac APPLICATIONS Suitable for: - 2-pipe system - 2-pipe system + On/off or floating valve - 2-pipe system + valve and electric heater - 4-pipe system + 2 on/off valves with neutral zone OPERATION 1. 2 pipe fan coil with valve: the thermostat controls both the fan and the valve according to the desired temperature. If water sensor is present, the fan is overridden according to the water temperature (warm and cold start function). 2. 2 pipe fan coil with valve: the thermostat drives both the fan and the valve based on the desired temperature. 3. 2 pipe fan coil with valve and electrical heater: the thermostat controls the fan, the valve and the electrical heater according to the desired temperature. 4. 4 pipe fan coil with two valves: the heating or cooling function is automatically determined by the neutral zone. The thermostat controls the heat valve in heating mode and the cold valve in cooling mode. If closes the valves when room temperature of system (warm and cold functions). During the installation, it is possible to choose between fans continuously running or fan thermostatic control. 4

SIMPLIFIED INTERNAL DIAGRAM 5

WIRES COLOR FOR ON BOARD INSTALLATION 6

i-basic3 Electrical diagrams LEGEND L = phase - 230 Vac N = neutral 230 Vac M = motor 230 Vac I = speed min II = speed med III = speed max Com = common motor KA1 = electric heater on/off relay XA1 = terminal board i-basic 3 YV1 = heat/cool valve 230 Vac on/off YV2 = heat valve 230 Vac on/off YV3 = cool valve 230 Vac on/off 7

i-basic3 Electrical diagrams LEGEND L = Phase 230 Vac N = Neutral 230 Vac M1 = Fan motor 230 Vac I = Speed min II = Speed med III = Speed max XA1 = Terminal board i-basic 3 YV5 = Heat/cool valve floating (3 point) 230 Vac 8

i-basic3 Electronic control LEGEND A1 = YV6 = YV7 = YV8 = Motor with electronic control 0-10 VDC Heat/Cool valve 0-10 VDC modulating Heat valve 0-10 VDC modulating Cool valve 0-10 VDC NOTE: 1. Not short the J9 pins not used 2. Pins 4 and 5 should never be wired (only factory used) 3. Motor regulation with electronic control: - Speeds switch in the position I = out fix 3VDC - Speeds switch in the position II = out fix 6VDC - Speeds switch in the position A: If DIP 5 = OFF the output is variable according to the set-point and room temperature (fan off with set point reached) Si DIP 5 = ON the output is variable according to the set-point and room temperature (fan at minimum speed with set point reached 1,5 VDC) 9

Electronic control OPEN = Cooling CLOSED = heating Air temperature sensor NTC10K@25ºc Always be used in case of the board installation The sensors recognized automatically by the thermostat. With the remote air sensor connected is active the destratification cycle: the fan operate for 90 sec. at minimum speed every 15 minutes. Water sensor temperature NTC10K@25ºC 1. In the case of automatic change over with 2 pipe System and 3 way valve, the sensor is positioned upstream of the valve. 2. In the case of 4 pipe System the sensor is positioned in the heating coil ECONOMY OPEN = Confort CLOSED = Economy In economy mode is set a fixed temperature: 17ºC Heating mode 28ºC Cooling mode WINDOW OPEN = Fan OFF = Valve closed CLOSED = Confort 10

On board installation Wall installation Note for installation: 1) The thermostat is composed of two parts: the base with the terminal and the electronics control. For easy installation the two parts are supplied separately (dropped). After the electrical connections on the terminal in the base, the two parties must be joined by 4 clips on the four corners: insertion of 4 teeth of 4 slots (picture B). 2) The base standard is designed for mounting with Italian wall box (type 503). It is possible replace the standard base with another base (accessory) for wall-mounted (picture C). 11

DIP-Switch function (back of the thermostat) Nº DIP FUNCTION OFF ON 1 2/4 Pipe system 2 pipe 4 pipe 2 Heating / Cooling switching Manual Automatic or centralized if DIP 7 = ON 3 DIP 3 = OFF DIP 4 = OFF DIP 3 = ON DIP 4 = ON No electric Heater No electric Heater Electric heater (combination of DIP 3 and DIP 4) DIP 3 = ON DIP 4 = OFF Electric heater substitution (heating only with electric heater and valve - cooling with valve) 4 DIP 3 = OFF DIP 4 = ON Electric heater integration (heating with electric heater and valve - cooling with valve) 5 Fan motor Thermostatic control Continuously running 6 Actuator type ON / OFF (thermal) Floating (3 points) 7 Heating / Cooling control Manual (local) Centralized 8 Function of auxiliary input Economy Window / remote on / off 12

Led function Cooling (Umbrella) - Thermostat demand: Led green on with fan running and valve opened Led green blinking (1 time every 2 seconds) with fan stopped and valve opened (fan it is in stand-by because the water temperature it is > 15ºC) - Thermostat in the set point reached: Led off (fan stopped and valve closed) Heating (Snowman) Air Filter - Thermostat demand: Led red on with fan running and valve opened Led red blinking (1 time every 2 seconds) with fan stopped and valve opened (fan it is in stand-by because the water temperature it is < 35ºC) - Thermostat in the set point reached: Led off (fan stopped and valve closed) - Fan on for electric heater post-cooling Led red blinking (2 time every 2 second) - Led yellow or orange = dirty filter (after 800 hours of fan operation) Reset dirty filter: make 5 transition fast (between one and one should not spend more than three seconds) between minimum (I) and medium (II) speeds 13

14 We reserve the right to add modifications without prior notice