Technical Data Manual

Similar documents
Installation Instructions VITOTRONIC 300

Installation Instructions VITOTRONIC 200

Technical Data Manual Model Nos. and pricing: see Price List

Service Instructions for use by heating contractor

Installation Instructions. Replacement of Control Console, Part No , Safety and Installation Requirements

Technical Data Manual Model Nos. and pricing: see Price List. VITODENS r 222-F

Technical Data Manual Model Nos. and pricing: see Price List. VITODENS r 200-W

Operating Instructions and User s Information Manual for use by engineers and heating contractors VITOTRONIC 100 IMPORTANT

Technical Data Manual Model Nos. and pricing: see Price List. VITODENS r 200-W

Application Guide. Vitodens 100-W B1HA/B1KA Residential Boiler

Technical Data Manual Model Nos. and pricing: see Price List

Technical Data Manual Model Nos. and pricing: see Price List VITOCROSSAL 300

Control Panel Checklist

Technical Data Manual Model Nos. and pricing: see Price List. VITODENS r 200-W

Quickheat 30 weather compensated boiler control

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

prestige Control Application Supplement - TriMax

Communication. Versatronik 581 & 581D LON Communication Gateway. Technical, Installation and Configuration Information. Cautionary Statement

Leading Word on Lag Modules

Technical Data Manual Model Nos. and pricing: see Price List

- Data Brochure Boiler Control 274

Control Application. Supplement - ACVMax

CM907- TRV PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

INSTRUCTION FOR THE USER THC V E OIL BLU

G a

prestige Control Application Supplement - TriMax

B-40/B-41 Modulating Temperature Controller

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

CM901 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

prestige Control Application Supplement - ACVMax

RVL481. Heating Controller. including d.h.w. heating

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

- Data Brochure Universal Reset Module 422

Boiler Demand Mix 1 Demand Mix 2 Demand DHW Demand Setpoint Demand

DHW / Setpoint Demand WWSD Modulation Boiler Output (x10,000 BTU/hr) External Input Signal Offset / Priority Override

Installation & Operation Manual

- Data Brochure Boiler Control 264e

INSTALLATION & USER MANUAL

Application Guide. Vitodens 200-W B2HA,B2HB Residential Boiler

Daikin Altherma/Viessmann Integration Notes (used with schematics M1 thru M5)

- Data Brochure Universal Reset Module 423

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

VITOSOL. Solar hot water heating systems Flat plate and vacuum tube solar collectors

VIESMANN. Datasheet For part no. and prices: see pricelist VITOLIGNO 300-P. Pellet boiler 4to48kW. Vitotec folder, register 12. File in: Type VL3B

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

Heating Controller for 2 heating circuits, d.h.w. and boiler, communicating

Application Guide. Vitodens 222-F B2TB Residential Boiler

SC-3 Controller INSTALLATION AND OPERATING INSTRUCTIONS FOR GAS-FIRED, OIL FIRED AND DUAL FUEL HOT WATER HEATING PLANTS. SC-3 Applications CONTENTS

- Essay Control Functions and Benefits

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

Better Design, Better Control, Better Systems.

Installation & Operation Manual

RVL470. Heating Controller. Use. Functions. Series B

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

Installation & Operation Manual

RVL479. Heating Controller. for use with a partner unit

VR 90 Remote control unit

RVP310. Heating Controller. Building Technologies HVAC Products

/2010 US/CA

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Electronic Pellet Burner Controller NPBC-V3M

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

RET2000 MD Electronic digital thermostat with LCD, delayed start. Danfoss Heating. Installation Guide

Honeywell SLATE ICM Platform

Hydronic & HVAC Control Systems

Installation & Operation Manual

Installation & Operation Manual

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

be liable for any other loss or damage, whether direct, indirect, incidental or consequential.

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

- Data Brochure Boiler Control 264

PRELIMINARY EDITION

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

Automation System TROVIS 5400 Boiler Controller TROVIS 5474

Sola Hydronic Control. An Eco-Friendly Solution.

Outdoor Reset IQ Option Card, p/n

Electronic Pellet Burner Controller NPBC-V3-1

- Data Brochure Mixing Control 360

RVL480. Heating Controller

Heating Controller SDC. District Heating Controller DHC 43 OPERATING INSTRUCTIONS

COnDEnSInG BOIlERS TAU UNIT OIL USER parameters manual

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

Installer Manual KNX Touchscreen Thermostat

Hydronic Mechanical Panels

- Data Brochure Steam Control 279

M2500 Engine Controller Installation Manual

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler

Logamax plus GB142. Applications Manual. Gas condensing boiler

Installation & Operation Manual

Vokèra OpenTherm 711 without external sensor connected

Condensing Boiler RS100 Controller Training Program

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money. How hydronic heating systems work

Transcription:

VITOTRONIC 300 Weather-responsive indoor/outdoor, digital boiler control for heating systems with one or more heating circuits Technical Data Manual Vitotronic 300 Model KW3, Part No. Z001 231 For operation with modulating boiler water s and single-stage, two-stage or modulating burners For heating systems with one heating circuit without mixing valve and up to two heating circuits with mixing valves With DHW tank sensor and integrated diagnostic system Operating module with clear text LCD display Remote control interface with or without room sensing Viessmann quick-connect plug-in system 09/2011 Certified as a component part of Viessmann boilers only

Product Information/Standard Equipment/ Application Product Information The benefits at a glance: Easy and uniform operation: - Different programming levels for system user and heating contractor - Large, clear text LCD display format facilitates legibility of all data - Illuminated operating mode and heating circuit keys - Easy-to-program switching times - Digital tracking of day and week. Programmed times for domestic hot water production and recirculation pump is adjusted automatically when heating program is altered. - Plug & Work quick-connect system for automatic sensor/system recognition and adaptation - Automatic resetting to daylight savings time - Service interval display for demand-related maintenance - Fuel consumption display Program selection for controlled drying of concrete floor in radiant floor heating application Short installation time, start-up and maintenance due to Rast-5 connector system, plug-in function modules and integrated diagnostic system Vitotronic 300, Model KW3 STS OTS STS Weather-responsive indoor/outdoor, digital boiler and heating system control: - for heating systems with one boiler - for heating systems with one direct-connected heating circuit and up to two mixing valve circuits - for single-stage, two-stage and modulating burners - with DHW tank sensor - with digital tracking of day and week - with separate switching times for space heating, domestic hot water heating and recirculation pump - with integrated diagnostic system Standard Equipment Vitotronic 300, Model KW3 (Part No. Z001 231) with operating module with clear text LCD display outdoor sensor boiler water sensor DHW tank sensor Power/Pump Module For a heating circuit with a mixing valve, a mixing valve actuator accessory kit is required. Due to the low return water of condensing boilers only 3-way mixing valves should be installed. For non-condensing boilers, such as Vitogas 100, Vitorond 200 and Vitola 200, a 4-way mixing valve may be used. The circulation pump with a flow check valve for DHW tank control must be ordered separately. Heating system with underfloor heating The underfloor heating circuit requires an accessory kit for operation with a mixing valve. A control with high limit must be installed into the flow of the radiant floor heating application. The underfloor heating circuit must not be controlled by a remote control with room sensor. Application WARNING When extending wire, there is the possibility of exposure to electromagnetic interference. Avoid running wires beside or near high voltage 120/240 VAC conductors. If proximity to high voltage conductors cannot be avoided, use stranded, twisted pair or shield design wire. Ensure that only one end of the shielding is grounded. In conjunction with the following Viessmann boilers Boiler Model and Series Oil-/gas-fired hot water heating boiler with power burner Atmospheric gas-/propane-fired hot water heating boiler Atmospheric gas-fired hot water heating boiler Fuel Vitola 200 Oil/Gas x Minimum boiler water without low limit with low limit (average temp.) Vitogas 050, RS Series Gas 120 ºF / 49 ºC Vitogas 100, GS1 up to 240 MBH / 70 kw Vitogas 100, GS10 up to 380 MBH / 111 kw Gas Gas 104 ºF / 40 ºC 120 ºF / 49 ºC 2

Structure and Operation Structure and Operation Modular structure The complete control consists of a control base, control unit (electronic operating modules), and a Power/Pump Module. The control unit comprises: Power on/off switch, an electronic high limit, a gage and a low control - adjustable high limit - fixed high limit TUV test switch, override switch, buttons for: - holiday program - party and economy modes - reduced operating mode s - domestic hot water - programming of heating curves for boiler water, mixing valve circuit - heating circuit selection, a selector knob for normal operating s and a digital timer. Heat-demand-controlled circuit pump and burner activation, adjustment option for variable limit, pump cycling, integrated diagnostic system and flue gas monitoring in connection with the flue gas sensor (optional) and maintenance display. Boiler-specific functions The Vitotronic control modulates the boiler water. It gradually regulates the boiler water (= the supply water of the direct-connected heating circuit) as well as the supply water of a mixing valve circuit. The control contains an adaptive tank control logic with priority switching (heat pump off, mixing valve closed). An additional function for domestic hot water heating (short-term heating to an increased ) can be selected. The Vitotronic 300 is an ideal control option for your heating system with mixing valve circuit. It is the perfect solution for your underfloor heating circuit with supply and return water sensor or for controlled drying of a concrete floor. Control characteristics - Boiler circuit control unit (high ) - Heating circuit control with mixing valve - Dead band: ±1.80 ºF/1 ºC - Adjustable high limit factory default setting: 167 ºF/75 ºC 205 ºF/96 ºC - Fixed high limit: 230 ºF / 110 ºC 212 ºF / 100 ºC - Adjustment range of heating curve: Slope: 0.2 to 3.5 Shift: 23 ºF to +72 ºF 13 ºC to +40 ºC High limit: 68 to 266 ºF 20 to 130 ºC Low limit: 34 to 261 ºF 1 to 127 ºC Differential for heating circuit with mixing valve: 0 to 72 ºF 0 to 40 ºC - Adjustment range for domestic hot water setpoint : 50 to 140 ºF 10 to 60 ºC, 50 to 203 ºF 10 to 95 ºC Technical data Rated voltage: 120 VAC Rated frequency: 60 Hz Rated current: 6 A Power consumption: 5 W - at operation: 32 to 104 ºF 0to 40 ºC (in rooms and installation sites with normal ambient conditions) - when storing or transporting: 4 to +149 ºF 20 to +65 ºC Relay output rating in conjunction with a Power/Pump Module: - Heating circuit pump : 3 FLA / 120 VAC *1 - Circulation pump for DHW tank heating : 3 FLA / 120 VAC *1 - DHW recirculation pump : 3 FLA / 120 VAC *1 - Compiled fault indicator : 3 FLA / 120 VAC *1 - Burner plug : 2 FLA / 120 VAC Two-stage burner plug *2 : 0.5 FLA / 120 VAC - Power supply to Power/Pump Module: max. 12 A / 120 VAC *1 Total 9 A / 120 VAC *2 Available only with extension module for two-stage burner (included in boiler package). Boiler coding card For adapting the control to the heating boiler and the respective heating system characteristics (included in boiler package). Connections - Sensors, burner and Power/Pump Module are connected to the back of the control unit via system plugs. - Pumps and power supply are connected to the Power/Pump Module via screw terminals or system plugs. - Mixing valve pumps and mixing valve supply sensors are connected to the mixing valve controller. The mixing valve controller receives power from a separate power source and communicates with the Vitotronic via the 2-wire KM-BUS. Operating unit - With digital timer - Clear text LCD display - Temperature and error message display - Coding via display of operating unit - All adjustments and basic coding information in clear text 3

Structure and Operation Digital timer of operating unit A digital timer with day and week feature, calendar, automatic resetting to daylight savings time and automatic functions for domestic hot water heating and recirculation pump. Time, day and standard switching times for space heating, domestic hot water heating and the domestic hot water recirculation pump are factory preset (individually programmable), max. four time switch intervals programmable per day Shortest interval: 10 minutes Power reserve: 5 years Adjusting the operating mode All operating modes provide freeze-up protection *1 for the heating system. With the program selector buttons the following can be selected: - heating and domestic hot water - domestic hot water only - standby operation *1 see Freeze-up protection function below. Freeze-up protection function The freeze-up protection function is - activated when the outdoor drops to +34 ºF / 1ºC. Freeze-up protection activates the circulation pumps and keeps the boiler water at the reduced operation setpoint level, at a minimum of approx. 68 ºF/20 ºC (for heating boilers with low limit the respective will be maintained). - deactivated when the outdoor exceeds 37 ºF/3ºC. When the freeze-up protection function is deactivated, heating boiler and circulation pumps are turned off. Heating curve adjustment The weather-responsive Vitotronic 300 regulates the boiler water (= supply of the heating circuit without a mixing valve) and the supply of the heating circuit with mixing valves. Boiler water is maintained from 0 to 72 ºF / 0 to 40 ºC above the calculated supply of either mixing valve circuit (factory default setting 5 ºF / 8 ºC). The required boiler supply for a certain room depends on the heating system and the insulation of the building in question. The adjustment of each heating curve allows for the boiler water and the supply water of the mixing valve circuits to adjust to these conditions. Heating curves: Low heating system, e.g. radiant floor heating Medium heating system, e.g. cast iron radiation, staple-up radiant floor heating High heating system, e.g. fintube radiation, fan coils Boiler water sensor Cable length 5.2 ft./1.6 m, ready to plug in. at operation: 32 to 266 ºF 0 to 130 ºC when storing or transporting: 4 to +158 ºF 20 to +70 ºC Outdoor sensor Installation site: - North or northwest side of building - 6.6 to 8.2 ft. / 2 to 2.5 m above ground, for multi-storey buildings mount sensor on upper half of second floor. Connection: - 2-wire cable, cable length 115 ft. / 35 m with a wire size of min. AWG 16 copper. - the cable to the outdoor sensor must not be laid near line voltage wiring (120 / 240 V). at operation, when storing or transporting: 40 to +158 ºF 40 to +70 ºC Domestic hot water tank sensor Summer economy mode (Domestic hot water heating only, program selector switch ) The burner only activates if domestic hot water needs to be produced (as required by DHW setpoint). The maximum boiler water is restricted by both the adjustable high limit and the electronic maximum limit. The supply water cannot exceed the boiler water. Cable length 19 ft. / 5.8 m, ready to plug in. : at operation: 32 to 194 ºF 0 to 90 ºC when storing or transporting: 4 to +158 ºF 20 to +70 ºC 4

Accessories Accessories Note on the room sensing function (RS function) *1 when using a remote control Due to the slow response of underfloor heating systems, the RS function must not influence an underfloor heating circuit. For heating boilers with a low limit, the RS function must not influence the heating circuit without a mixing valve. Vitotrol 200, Part No. 7133 378 Vitotrol 300, Part No. 7133 382 *1 RS function = remote control with room sensor function *2 WS function = remote control only, no room sensor function The Vitotrol 200 remote control takes care of room setpoint adjustment at normal operation and determines the heating program from any given room. The Vitotrol 200 features illuminated heating program selector buttons as well as a party and an economy button. Error messages are displayed on the boiler control. A remote control can be connected for each heating circuit. WS function *2 : Installation at any given place in the building. RS function *1 : The remote control must be installed on an inside wall of the main living area, across from radiators, but not on shelves, in niches, in the close vicinity of doors or heat sources of any kind (e.g. direct sunlight, fireplace, TV etc.). The installed sensor measures room and, if necessary, takes corrective action and initiates fast heat-up at the outset of heating operation (if coded). Connection: - 2-wire cable, cable length max. 164 ft. / 50 m (also for the connection of several remote controls). - The cable must not be laid near line voltage wiring. - Low voltage connector is included. Rated voltage: 33 VAC Rated current: 10 ma Power consumption: 3.3 W at operation: 32 to 104 ºF 0 to 40 ºC when storing or transporting: 4 to +149 ºF 20 to +65 ºC Adjustment range of room setpoint: 50 to 86 ºF 10 to 30 ºC, 37 to 73 ºF 3 to 23 ºC or 63 to 99 ºF 17 to 37 ºC Adjustment of the room setpoint at reduced operation takes place at the Vitotronic 300. The Vitotrol 300 remote control takes care of room setpoint adjustment for one heating circuit at normal and reduced operation, switching times for space heating, domestic hot water heating and the domestic hot water recirculation pump. The Vitotrol 300 features illuminated heating program selector buttons, a party and an economy button, an automatic reset function to daylight savings time, buttons for the holiday program, day of the week and time. WS function *2 : Installation at any given place in the building. RS function *1 : The remote control must be installed on an inside wall of your main living area, across from radiators, but not on shelves, in niches, in the close vicinity of doors or heat sources of any kind (e.g. direct sunlight, fireplace, TV etc.). The installed sensor measures room and, if necessary, takes corrective action and initiates fast heat-up at the outset of heating operation (if coded). Connection: - 2-wire cable, cable length max. 164 ft. / 50 m (also for the connection of several remote controls). - The cable must not be laid near line voltage wiring. - Low voltage connector is included. Rated voltage: 33 VAC Rated current: 10 ma Power consumption: 3.3 W at operation: 32 to 104 ºF 0 to 40 ºC when storing or transporting: 4 to +149 ºF 20 to +65 ºC Adjustment range of room temp. setpoint: at normal operation: 50 to 86 ºF 10 to 30 ºC, 37 to 73 ºF 3 to 23 ºC or 63 to 99 ºF 17 to 37 ºC at reduced operation: 37 to 99 ºF 3 to 37 ºC 5

Control Accessories Vitotronic Control Accessories Mixing Valve Actuator Accessory Kit, Part No. 7133 392 (old version) Mixing Valve Actuator Accessory Kit, Part No. 7837 524 (new version) Room sensor, Part No. 7133 379 Fig. 1 (dimensions in mm) Rated voltage: 120 VAC Rated frequency: 60 Hz Rated current: 4 (2) A Power consumption: 4 W Max. ambient at operation: 32 to 104ºF 0 to 40ºC when storing or transporting: Relay output for heating circuit pump: Actuator torque: Time of 90 ºí: 4 to +149ºF 20 to +65ºC 4(2) A, 120 VAC 3 Nm 2 minutes Supply Temperature Sensor (strap-on sensor, included with mixing valve actuator accessory kit), Part No. 7133 895 (old version) when storing or transporting: 20 to+70ºc Fig. 3 (mm) The mixing valve actuator is mounted directly on the Viessmann ¾ to 2½ mixing valve. The mixing valve actuator is a motor-driven control unit. The rotational direction is reversible. The mixing valve actuator comes with a plug-in connector for a heating circuit pump, supply sensor (strap-on sensor with 7 ft. / 2.1 m connecting cable), power supply connecting cable (9 ft. / 2.7 m) and a connecting cable (9 ft. / 2.7 m) for the KM-BUS Expansion Module. Rated voltage: Rated frequency: Rated current: 120 VAC 60 Hz 4 A Power consumption: 5W max. ambient - at operation: 32ºF to 104ºF (0ºC to 40ºC) application in living areas and installation sites (normal ambient conditions) -storage & shipping: -4ºF to 149ºF (-20ºC to 65ºC) Max. relay outputs at 120VAC for: - Heating circuit 1.0 A - Mixing valve 0.2 A Supply Temperature Sensor Part No. 7183 288 (new version) A separate room sensor as an addition to the Vitotrol 200 or 300 remote control; to be used when the Vitotrol 200 or 300 cannot be placed in the main living area or in a position suitable for monitoring the room. The room sensor must be installed on an inside wall of the main living area, across from radiators, but not on shelves, in niches or in the close vicinity of doors or heat sources of any kind (e.g. direct sunlight, fireplace, TV etc.). The room sensor is to be connected with the Vitotrol 200 or 300. Connection: - 2-wire cable with a wire diameter of AWG 16 copper.cable length between control unit, remote control and room sensor must not exceed 115 ft. / 35 m. - Cable must not be laid near line voltage wiring. at operation: 32 to 104 ºF 0 to 40 ºC when storing or transporting: 4 to +149 ºF 20 to +65 ºC Fig. 2 (dimensions in mm) Installed with a strapping band. Cable length 19.7 ft. / 6 m, ready to plug in.max. ambient at operation: 32 to 212ºF 0 to 100ºC when storing or transporting: 4 to+149ºf ( 20 to+70ºc) Fig. 4 (mm) 6

Accessories KM-BUS Expansion Module, Part No. 7133 393 Flue gas sensor, Part No. 7133 389 For the flue gas readout, flue gas monitoring and maintenance display when exceeding a programmed. With cable (10 ft. / 3 m long) and low voltage connectors. To connect up to 6 devices to the single KM-BUS connection of the boiler control (Vitotrol, Switching Module-V, mixing valve etc.). Switching Module-V, Part No. 7133 387 With cable (10 ft. / 3 m long) and low voltage connectors. With the Switching Module-V the following additional functions are feasible: - external burner activation for heat demand (influences burner as well as pumps and mixing valves, if installed), e.g. pool heating, ventilation equipment etc. - external disabling of burner - remote switching of heating/operating program, separate for each heating circuit - external error message input - output of error message (SPDT contact) - connection for short-term operation of domestic hot water circulation pump (e.g. by external button). Cable length 8 ft. / 2.5 m, ready to plug in, with threaded cone. The flue gas sensor must be installed on the vent pipe. The distance must be approx. 1.5 times the flue gas pipe diameter from the flue gas collar of the boiler. For condensing boilers: The opening required for installation on the vent pipe must be provided for and checked by the manufacturer. The flue gas sensor must be installed (on site) into a stainless steel sensor well. : at operation: 32 to 1112 ºF 0 to 600 ºC when storing or transporting: 4 to +158 ºF 20 to +70 ºC 7

Technical information subject to change without notice. Printed on environmentally friend (recycled and recyclable) paper. Viessmann Manufacturing Company (U.S.) Inc. 45 Access Road Warwick, Rhode Island 02886 USA Tel. (401) 732-0667 Fax (401) 732-0590 www.viessmann-us.com info@viessmann-us.com Viessmann Manufacturing Company Inc. 750 McMurray Road Waterloo, Ontario N2V 2G5 Canada Tel. (519) 885-6300 Fax (519) 885-0887 www.viessmann.ca info@viessmann.ca 8