DOOR & WINDOW ALARM Cat No. TG232W INSTALLATION & OPERATING INSTRUCTIONS
TG232W Door & Window Alarm Please read the instructions before using the product and retain for future use. Alarm/chime PP3 battery (not supplied) 1 Battery connector Chime off/alarm slide switch Battery cover Fig 1
Introduction The TG232W uses a magnetically operated sensor to detect doors and windows being opened. It has two selectable sounder modes alarm and chime. The high output alarm (105dB) is useful when you wish to deter intruder entry and the chime mode can be used when you wish to be informed of movements at entry points or within the building. 2 Battery Installation/Change Move slide switch (see fig 1) to off. Press down on the raised arrow head on the battery cover and slide the cover in the direction of the arrow removing it from the alarm unit. Remove the battery connector from the old battery if necessary and push it onto the new battery. Slide the battery cover back into position.
Installation Fig 2 Alarm unit Door/window frame Door/window 3 Arrow facing arrow Magnet Switch Alarm unit Keyhole fixings Fig 3 (rear view)
4 InstallationDecide on a position for the alarm unit and magnet/sensor ensuring that the twin flex is sufficiently long to connect the sensor to the alarm unit and that there is good access to the slide switch and battery compartment on the alarm unit. Fix the magnet to the edge of the chosen door or window using two of the smaller screws or one of the double-sided adhesive pads provided. Fix the sensor to the door or window frame directly opposite the magnet with any arrow on the magnet pointing towards the arrow on the sensor. The gap between the magnet and the sensor must be 6mm or less. The alarm unit may now be fixed to the wall by drilling two holes 43mm vertically apart and using the two larger screws and wall plugs supplied. Remove the terminal cover from the sensor by pressing down at the centre and sliding out. Route the twin flex from the alarm unit to the sensor and remove any excess allowing for termination. Strip around 12mm of insulation from each wire and insert the stripped wires under the sensor terminal
5 Checking Operation Move the slide switch to chime and open the door or window. A two tone chime will occur immediately and will only repeat if the door/window is closed and opened again. Slide the switch to alarm and repeat the above test. The alarm will sound for around 30 seconds then stop unless the slide switch is moved to off. Closing the door/window will not stop the alarm once it has been activated. Specifications Alarm: 105dB Battery type: PP3 Alkaline 9V (not supplied) Battery life: Assuming that there are no more than 3 alarms or 25 chimes per day expected life is 4 months.
6 3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For the second and third years or any difficulty in the first year telephone the helpline on 020 8450 0515. THREE YEAR 3 GUARANTEE
HELPLINE 020-8450-0515 For a product brochure please contact: Timeguard Ltd. Victory Park, 400 Edgware Road, London NW2 6ND 020-8452-1112 or email csc@timeguard.com