Columbia Boat Alarms, Inc. Canvas snap sensor Installation.

Similar documents
Columbia Boat Alarms, Inc.

Speaker Wall Mount (MSP-DCCSPM)

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

Modular Drawer Cabinets Installation Instructions

Parts & Material Included

America s Best Home Products, L.C. 855-GF14FAN. CoolMyGarage.com

TS40 Product Assembly & Service Information Manual

INSTALLATION INSTRUCTIONS

Oreck Edge - Upright Tune-Up & Service Guide 02/26/2010

Models , Equinox, and Sirens Clutch Replacement Service Manual

USSC LLC 4 ONE LLC FIELD MODIFICATION INSTRUCTIONS

KIT NOTICE. These instructions are for replacing the three existing thermostats with a single new solid-state thermostat.

Everbrite LCD OrderRite Order Confirmation System

Water Distiller Service Manual

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

DRAIN WATER TEMPERING INSTALL

HydroCycle Vertical Aeroponic Systems

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

Secure the other corner. bracket using the remaining screw,

America s Best Home Products, L.C. 855-GF14FAN. CoolMyGarage.com

HD150. Introduction. Table of Contents

GETTING STARTED OPTIONAL HARDWARE A

pushing the tube into the rear of the water outlet housing with a slight twisting motion to evenly distribute the adhesive. After cleaning off any ext

WIRE GUIDE BLIND OUTDOOR DELUXE ROLLER. 5YR Warranty ASSEMBLY GUIDE

Arctica Solar 1500 Series Heater Installation Manual

CIB 3076 Extra Alert Strobe (61221)

BC BRONCOS AIR CONDITIONING UNIT

APEX Water Filters MODEL RO 5. Treat your body to pure goodness with Apex filtered water INSTRUCTION MANUAL. pure water in every drop

2-ZONE EASYFIT INTRUDER ALARM

WARNING. Tighten strain relief screws to secure cable. Make sure screw heads are facing up when tightening conduit nut.

INSTALLATION INSTRUCTIONS For The "North" Wood Burning Cook Stove energy saving Hot Water Kit

IB 835. Installation Manual. Integrated Bidet Toilet TABLE OF CONTENTS

Remote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI)

Camaro A/C Install Instructions

Installation Instructions

INSTALLATION, OPERATION, SERVICE & PARTS SUPPLEMENT for

HID312, HID525 and HID540 Service Parts

Threaded Faucet Installation

Instructions Apply For Model PHTT-6P-KFC. Panel Shelf Is Removed to install warming drawers

Mopar B-Body Condenser Kit with Drier

AQVA ULTRA Faucet Purifier AQ003-1 User s Guide

Glass Vessel Sink Installation

Super Deluxe Controller Assembly AC2089 & Base Kit AC2055

Installation Guide for Stern SPIKE 2 Speaker Light Kits

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

HydroCycle Vertical Aeroponic Systems

Nut & Bolt Faucet Installation

BUBBLE-Maker. Necessary tools and materials:

I had to remove front splash shield to drain the radiator.

FPU SYSTEMS OPERATION MANUAL (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH CONTAINERIZED LATRINES BOH FPU Field Pack-up Units

PARTS LIST. Specification code: (JAI 45231) (JA) (JCA) (JUK) (JHBV)

ARIN THERMOSTATIC SHOWER SYSTEM

Guidelines for Earthquake Bracing of Residential Water Heaters

CONTENTS

Table of Contents What to Expect with Your Installation. Ceiling Plate. Tools Needed.

AIR ONE PROFILER TOP and SIDE DRYER INSTALLATION MANUAL Part # DRYRPROFLRXXXXXX (ALL COLORS)

Flipper Fidelity FF SPK CX CV Coax Speaker Installation Instructions ( )

KIT NOTICE. These instructions are for replacing the two existing thermostats with a single new solid-state thermostat.

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST CHEVROLET CHEVELLE/ EL CAMINO NOTE: INSTRUCTIONS DEPICT CHEVELLE

Pilot devices Stacklights Signal beacons

Installation & Operation Instructions

COFFEE ROASTER VENTILATION HOOD INSTALLATION AND OPERATING INSTRUCTIONS

Building the seismograph

Integrated Refrigeration

Installation Instructions Component Systems Professional Line

by Water Purification Supplies

General System Layout Sketch

Page 1 of 18. Part# /5/2013

INSTANT HOT WATER DISPENSER

Building and testing Lunch Box Alarms By: Liam R.

HORIZONTAL AGITATOR ASSEMBLY

INSTALLATION INSTRUCTIONS

Taifun User Guide Notice Maintenance and cleaning

2-ZONE EASYFIT INTRUDER ALARM

400 SERIES REMOTE SIREN WITH REMOTE ROTARY CONTROL PANEL ETSA481RSR - 100W ETSA482RSR - 200W

Congratulations with your purchase of our high quality, corrosion-free hot water cylinder (HWC).

Modular Fillerplate Subassembly P/N: X Endcap P/N: Strike *, P/N: " Narrow Stile Plastic Template. Mortise.

Vehicle Tank Protection TANKSAVE. Fuel anti-theft system. Deters Warns

J-PRO-24 Soda Ash Injection Installation & Start-Up Guide

PolyMax H1-10 Dutch Bucket System

Vertical Blinds. Step by Step Installation Instructions

User Manual Box Exhaust Fan Series (Belt Drive)

Installation. Leveling

1. Physical Installation 2. In-app Setup 3. Features 4. Troubleshooting 5. Advanced Installation Options

JOHN DEERE GATOR HPX/XUV 2 PASSENGER HEATER INSTALLATION INSTRUCTIONS (p/n: 9PH20S30)

Single-Control Lavatory Faucet

EAGLE 2000B EAGLE 2000BE EAGLE 2000EBT MUST READ MANUAL PRIOR TO INSTALLING MACHINE

GENIE CLIP TYPE RST. Resilient Sound Isolation Clip INSTALLATION INSTRUCTIONS

Programmable Thermostat

INSTALLATION INSTRUCTION

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

400KV Van de Graaff Generator Kit Builders Manual

Installation and Maintenance for FlexValue Cleanroom Ceiling Model

Installation Instructions

Flipper Fidelity FF STN 10 WM Flippin Fantastic Big Ten Inch Stern Speaker Installation Instructions(03/14/16)

This document applies for optional accessories for the DSP70-C1 kit To read attentively and to conserve for further consultation

Installation Manual Mopar Engine Compartment Upgrade Kit

FLANGE ISOLATION KITS

Because it is possible. Because it is possible To eliminate the wiring work, the installation time is reduced dramatically. Installation time saving

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD PICKUP

Transcription:

Columbia Boat Alarms, Inc. Canvas snap sensor Installation http://www.columbiaboatalarms.com sales@columbiaboatalarms.com 1

FIRST A LITTLE ALARM STRATEGY Perimeter alarm protection is very desirable because we want to discourage a would-be intruder from boarding the boat. There are two forms of perimeter protection with the Model 411 boat alarm, the flashing LED and canvas snap sensors. The flashing LED placed in plain view near an alarm sticker will alert an intruder that this boat is protected with an alarm system. The canvas snap sensors should be located where an intruder is most likely to open the canvas to enter the boat. Then as soon as the canvas is opened the alarm siren will go off. It is not possible for an intruder to observe which snaps are protected or even if they are protected. An intruder most certainly will not reconnect the snap when the siren sounds. He will probably leave the area. For this reason the canvas snap sensors should be connected to alarm zone 1 (The two white wires on the alarm control). Alarm zone 1 will sound the siren only one time and then become inactive. Zones 2 and 3 still provide alarm protection. Think of the canvas snap sensor as a switch that replaces the existing canvas snap stud. This switch is on when the canvas cover is snapped to the sensor. When the canvas cover is unsnapped the switch turns off causing the alarm control to sound the siren. 2

BEGIN INSTALLATION THINGS TO CONSIDER BEFORE STARTING 1. Review the Columbia Boat Alarms, Inc. Recommended Wiring Procedure. 2. Select the snap locations that an intruder would need to open before boarding the boat. 3. Carefully check to be sure the sensor wires and sensor retaining nut can be accessed. 4. What will be the wire route between the alarm control and the sensor? Again check inside the boat to be certain of access to the back of the sensor to install the retaining nut and to connect the canvas snap sensor wires. At the selected locations remove the existing canvas snap stud. The snap stud is frequently fastened with a screw or poprivet. The screw or pop rivet holes make excellent pilot holes for drilling the holes for the sensors. Carefully drill a 25/64 hole thru the boat at the location for the sensor. Drill perpendicular to the surface at the sensor location so the sensor will fit square and tight to the boat surface. Remove the retaining nut from the sensor and insert the sensor through the hole as shown in the following photo. The O-ring remains on the stud. 3

After inserting the sensor into the hole secure the sensor with the nut on the threaded portion of the sensor stud. Tighten the retaining nut until the O-ring seals between the boat and the sensor stud. The next photo shows the backside of the sensor with the nut installed. 4

The canvas snap sensor stud is now mounted and should appear as shown in the next photo. 5

Repeat the above process until all the canvas snap sensor studs are installed. The next step is to place magnets in the canvas caps at the sensor locations. If a magnet is not in a cap when the cover is snapped to the sensor stud the alarm siren will sound one minute after the alarm has been activated. (One of the switches is open.) A magnet will hold to a flat screw driver which makes it easy to place it inside the cap on the canvas. Note the next picture. 6

The magnet fits into the riveted cap. If the magnet will not fit into the hole on the inside of the cap, then replace the cap. Be careful not to over rivet the new cap and deform the hole inside of the cap. A 1/8 th inch punch often works nicely to form the inside of the cap for the magnet. Use epoxy or super glue to hold the magnet inside the cap. Place a magnet in every cap that snaps onto a canvas snap stud. 7

The next step is to wire the sensors to the alarm control. The diagram below shows the sensors wired to zone 1 or the two white wires out of the control box. Other sensors such as the cable wrap can also be wired to zone 1. Many sensors can be wired in series to zone 1. The sensors added to zone 1 are wired in series. A description on how to connect three sensors to zone 1 follows. Sensors on Zone 1 and zone 2 are connected in series. First connect to one of the white wires. Then connect to the first wire on the first sensor. The second wire on the sensor connects to the first wire on the second sensor. The second wire on the second sensor connects to the first wire of the third sensor. The second wire on the third sensor returns back to the second white wire on the alarm control. Next is a schematic showing three sensors wired to zone 1. 8

9