CONNECTA SYSTEM The fire performance tunnel lighting and power system

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

The world s most trusted cable brand

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

The world s most trusted cable brand

Introduction.

PASSIVE FIRE PROTECTION FTI-MARNEROS LTD

Fire Resistant Cables

Retro-DWS Other Methods Internal Heating Cable System for Sewer Pipe and Waste Drain Applications

Snifter ATEX22 VERSION. User Manual. Distributor

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

M7100 Pressure Transducer

Cable Actuated Sensor Industrial User Scalable VDC Output

Installation Manual Universal Top-of-Pole Mount UNI-TP/02

Small Box for Cable Termination. 3.1 Preparation of box 3.3 Mounting of the box on the wall

ENERGY /// RAYCHEM CABLE CLAMPS RAYCHEM CABLE CLAMPS. Quick Reference Guide

REDI PVC Injection Moulded Sewer Fittings

THE COMPLETE SOLUTIONS PACKAGE

GLOBAL ENCLOSURE STANDARDS WITHIN THE ELECTRICAL INDUSTRY

PT9101. General. Potentiometer Cycle Life 250,000 Maximum Retraction. Weight, Aluminum (Stainless 8 lbs. (16 lbs.) max. Electrical

Cable Actuated Sensor Industrial User Scalable 4 20mA

PROFILE. industrial services rental trading

SPECIALISTS IN CONNECTING TECHNOLOGIES AND ENCLOSURES.

Electrical Safety The Hidden Perils

SPECIFICATIONS. SENSOR SOLUTIONS ///LM Page 1 09/2015

LC3000 Level Controller Installation and Maintenance Instructions

Stored Water District Heating Interface Units. Heat Interface Units

30 mm 180 mins RWS / HCM. 24 mm 120 mins RWS / HCM. GS Kitchen Extraction & Ventilation up to 240 mins, BS 476 pt 20 & 24

PT9420 (Extended Range)

DP86 Constant Voltage with Fitting

The Professional Choice

Low Voltage Catalogue_Final ai 11/8/09 11:37:27 AM BICC 1 BICC Final Brochure-NEW.indd 1 7/5/10 3:02 PM

Advanced Fire Rated Ductwork Solutions

For Heavy Duty Commercial and Industrial Environments

Products Overview. Your trusted partner in process instrumentation

Gambling with your fire security?

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

RHT RAIL HEATER. Rail & Switch Point Heating System. Pre-Terminated Lengths or Cut-to-Length from the Reel

The Professional Choice

PT9600. Cable Actuated Encoder Reel. General. Environmental

Retro-DWS Internal Heating Cable System for Non-Pressurized Sewer and Waste Drain Pipes

RayClic Connection System

FIST-EDSA-D4. 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop cable. 6 Gel part replacement

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

The DEF-System by BRUGG. The Best Way to defeat the problem of DEF heat Installation Instructions

Industrial Strength Leak Detection

Ingersoll Rand. Refrigerated Air Dryers

AT-G-DETECT Gas Sensing System

All Valve Industries. General Product Overview. Distributed by All Valve Industries. Ph: Fax:

GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

Hazardous Area Zirconia Oxygen Systems

TOMORROW S SOLUTIONS TODAY

Notice No. 7. Rules and Regulations for the Classification of Ships, July Issue date: March Working together for a safer world

OPTISENS TUR 2000 Technical Datasheet

Cistern-fed water heating

Commercial. Tel:

Legal Requirements. There is no general legal requirement to install sprinklers. in places of work

PT9150 (Extended Range)

WKE Spelsberg. The name in maintaining electrical integrity.

Self-Regulating Point Heating Performance Requirements

Installation and Safety Instructions Cone Wall Light with PIR Stainless Steel Model: S083S

The Professional Choice

Snifter. User Manual. Distributor

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

aquilar - leak detection solutions

Side Entry Bushing (SEB) High Temperature Cable Clamp Bushing Installation Instructions

SELF PRESERVATION SOCIETY By Jim Creak

Dublin airport - Dublin, Ireland

Unvented Water Heating. Zircon

TSL hand dryer. installation + maintenance

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

Gardian W51. Approvals

Installation Manual Universal Top-of-Pole Mount UNI-TP/08LL

3M Benchtop Air Ionizer 963E. User s Guide

Risk Management Services. Electrical Safety Inspection and Testing. We can show you more.

SELF STORAGE SOLUTIONS

LABORATORY ILLUMINATED FLOTATION BATH

Installation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5

aquablend thermostatic mixing valves

Masterseal Plus. IP66 Ingress Protected. Thrives in the Toughest Conditions.

Cable Actuated Sensor Industrial Incremental Encoder Output

XT Series Thermostats

Installation Manual Universal Side-of-Pole Mount UNI-SP/01A

Controlled Door Closing Devices

commercial-type cabling and connectivity products into the industrial landscape.

INSTALLATION AND MAINTENANCE GUIDE TRENDY 1000 T ELECTRONIC LAVATORY FAUCET

Surface Mount Wall PIR Light Controller. Model: PDWM1500. Installation & Operating Instructions

NUMERICAL SIMULATION OF FIRE SPREAD IN TERMINAL 2 OF BELGRADE AIRPORT. PO Box 522, Belgrade, Serbia and Montenegro

INSTRUCTIONS. MODEL: CPC and CPC1 PIE CABINETS

Weed Instrument Application Driven Designs for Pharmaceuticals and Biotech

INSTALLATION INSTRUCTIONS SAFETY INSTRUCTIONS USER INSTRUCTIONS PIE CABINET

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

Multi Branding Strategy

Installation, Operation and Maintenance Manual

Howler Go-Link Evacuation Alarm

Seal Kits for BUDI Enclosures

The Legal Obligations of Employers to Maintain all Electrical Installations in a Safe Condition

Sub psi SPECIFICATIONS

Retail solutions by Tenos. Value engineered fire safety solutions for landmark retail developments.

Information Sheet LIA IS 07 Issue 1 08/2013 Page 1 of 5 For LIA members use only

Transcription:

Connecta System THE FIRE PERFORMANCE TUNNEL LIGHTING AND POWER SYSTEM

Connecta. Deliveri safety for tunnel e When it comes to specifying fire performance cables, zero halogen building wires and power cables, you have to choose products from a company you can trust. Draka is that company, an international cable manufacturer with a turnover of 1.7 billion and over 9,000 employees worldwide. As part of Draka Cableteq Low Voltage Europe, a division of Draka Holding NV, we are the leading supplier of fire performance cables, zero halogen power cables and building wires in the UK. With over 80 years of in-depth experience, our vast product range has been developed and manufactured with leading-edge technology and is backed by the resources of one of the world s major specialist cable companies. The Group s expertise delivers a wideranging product portfolio including communication, low voltage and special purpose cables. In addition we have the capability to manufacture customerspecific cable types. Part of our continuing success is down to our commitment to ongoing product development through investment in innovation. We are constantly working to improve our product range to meet your specific needs. Indeed, the development of our product range forms the cornerstone of our entire operation. Connecta maintains the integrity of a circuit even if a local device suffers fire damage.

ng optimum power nvironments. Luminaire Fire Resistant cleats Connecta socket and plug Secondary cable Primary cable Brown L1 Black L2 Grey L3 Example of take off sockets at pre-determined lengths Connecta, part of our market-leading Firetuf range, is one such product. Manufactured in partnership with Custom Design Group of Cwmbran, South Wales, Connecta has been specifically developed to provide lighting and small power applications in tunnel environments. In the event of a fire, Connecta maintains the integrity of the circuit even if a local device fails, allowing escape routes further up and down the line to remain illuminated.

Connecta. Simple to install, easy to maintain. At Draka, we fully understand the importance of fire performance cables. This is why we are deeply committed to a policy of ongoing product development through investment in innovation. This is not just because we want our products and range to be consistently improved, so that they are better able to satisfy your needs, but because we understand that lives are at stake and that the performance and effectiveness of our products can help prevent loss of life. In short, at Draka we know that the safety of occupants and passengers in mass transit systems, especially road and rail tunnels, is of paramount importance. One factor that can play a key role in making these environments safer is the appropriate use of fire performance cables for critical safety systems. In the event of a tunnel fire and smoke filled environment, it is vital that the emergency lighting remains secure, to ensure that escape routes are clearly illuminated. Moreover, the correct selection and installation of these vital safety cables ensures that, in the event of an emergency, systems can continue to function and people will have time to evacuate safely, as well as helping the emergency services to operate effectively.

The technical resources of Draka and Custom Design Group have combined to deliver a system that offers optimum fire safety performance in tunnels. Connecta is manufactured with high quality injection moulded zero halogen, low smoke (OHLS ) components and features a male joint and female plug with an optional integral fuse and coupling nut. It is available with a primary cable of 2.5mm 2 to 50.0mm 2, in 3, 4 or 5 core variations and with a wiring loom length of approximately 700 metres.* This ensures the system is ideally suited to a wide variety of tunnel environments for the provision of emergency lighting and 3 phase power supplies. Another significant benefit of Connecta is the ease in which it can be installed and maintained. With project deadlines becoming tighter and tighter, Connecta offers both time and cost-saving benefits to a variety of applications. Installation is quick and simple With all of the lighting or power joints manufactured in a clean factory environment, rather than in-situ on site, installation times can be significantly reduced. This can assist in meeting or bringing forward project milestones or deadlines. In addition, with the jointing pre-manufactured, the need for highly skilled electrical installers can be reduced, as Small Large Extra Large Connecta Connecta Connecta Diameter (mm) 70 90 90 Length (mm) 150 220 260 Weight (Kg) 1.5 2 2.2 Dust Cap Socket Outlets Support Brackets * Dependant on cable size and number of sockets

the system can be installed by semi-skilled labour, again offering a cost-saving benefit. Each coupling system is specifically designed and manufactured to meet the clients needs with pre-set lengths Sectional view of Connecta socket between each moulded socket outlet unique to each installation. Secondary outputs are then taken from the primary cable via moulded plugs to pre-wired individual luminaires. Therefore Secondary cable connection to luminaire Connecta. Three components pre-assembly Connecta fully assembled fuse View of joint retaining coupling nut not only is Connecta easy to install but because of its modular design, maintenance is also simple. Each Connecta is phase identified and circuit integrity meets the requirements of BS6387 Categories C, W and Z. Ingress protection meets IP 67 standards. As part of the Firetuf range of fire performance cables, Connecta also benefits from being a zero halogen, low smoke (OHLS ) system. Example of cable laying and socket positions

Dublin Port Tunnel

Connecta. Tried an No-one does more to ensure their products deliver optimum performance than Draka. As you would expect, Connecta has been tested to the highest possible standards and meets BS 7671, I.E.E. Wiring Regulations. Our testing and commissioning programme ensures all components are tested individually then again as a complete system with luminaires energised. Fire, Fire with Water and Fire with Mechanical Shock tests are all rigorously completed by our specialists and as a result Connecta is fully approved to BS 6387: 1994 and SS299 Pt1: 1998 (Singapore Standard). Furthermore the BS 6387 category C, W and Z is the internationally recognised UK test, used to determine if a cable is capable of maintaining circuit integrity under different fire conditions, as the illustrated tests show. Connecta from Draka. Tried, tested and trusted by specifiers and contractors throughout the world. Rated to IP67 The Connecta system has been installed in the Channel Tunnel Rail Link (CTRL), London Underground, Heathrow Terminal 5 Tunnels, Dublin Port Tunnel and the Singapore Mass Transit Network (MRT) amongst others.

INGRESS PROTECTION TESTS tested. First Degree of protection from foreign particles characteristic numeral Brief description Definition 0 Non-protected 1 Protected against solid foreign The object probe, sphere of objects of 50mm ø and greater 5Omm ø shall not fully penetrate 2 Protected against solid foreign The object probe, sphere of objects of I2,5mm ø and greater 12,5mm ø shall not fully penetrate 3 Protected against solid foreign The object probe of 2,5mm ø objects of 2,5mm ø and greater shall not penetrate at all 4 Protected against solid foreign The object probe of I,0mm objects of 1,0mm ø and greater shall not penetrate at all BS6387 Category W - Resistance to fire and water; 650ºC for 15 minutes, then for 15 minutes with fire and water 5 Dust-protected Ingress of dust is not totally prevented, but dust shall not penetrate in a quantity to interfere with satisfactory operation of the apparatus or to impair safety 6 Dust-tight No ingress of dust Second Degree of protection from water characteristic numeral Brief description Definition 0 Non-protected 1 Protected against vertically Vertically falling drops shall falling water drops have no harmful effects 2 Protected against vertically Vertically falling drops shall have falling water drops when no harmful effects when the enclosure tilted up to 15º enclosure is tilted at any angle up to 15º on either side of the vertical 3 Protected against spraying water Water sprayed at an angle up to 6Oº on either side of the vertical shall have no harmful effects 4 Protected against splashing water Water splashed against the enclosure from any direction shall have no harmful effects BS6387 Category C - Resistance to fire; 950ºC for 3 hours 5 Protected against water jets Water projected in jets against the enclosure from any direction shall have no harmful effects 6 Protected against powerful Water projected in powerful jets water jets against the enclosure from any direction shall have no harmful effects 7 Protected against the effects of Ingress of water in quantities temporary immersion in water causing harmful effects shall not be possible when the enclosure is temporarily immersed in water under standardised conditions of pressure and time BS6387 Category Z - Resistance to fire with mechanical shock; 950ºC for 15 minutes with 30 second hammer blows 8 Protected against the effects of Ingress of water in quantities continuous immersion in water causing harmful effects shall not be possible when the enclosure is continuously immersed in water under conditions which shall be agreed between manufacturer and user but which are more severe than for numeral 7

Draka Cableteq Low Voltage Draka UK Limited, P.O. Box 6500 Alfreton Road, Derby, DE21 4ZH, UK Tel: +44 (0)1332 345431 Fax: +44 (0)1332 331237 email: firetuf@draka.com www.drakauk.com www.cdg-uk.com All the information provided - including charts and diagrams - is believed to be correct at the time of going to press. However, Draka UK makes no warranties as to its accuracy, and accepts no liability regarding its use. Draka UK s Conditions of Sale for each product specify the company s obligations and are available on request. In the interests of continuous product improvement, Draka UK reserves the right to alter specifications or materials as appropriate. The suitability of individual products for specific applications should be determined by the user. Draka UK accepts no liability for any incidental, indirect or consequential damages arising from the sale, resale, use or misuse of the product. BS EN ISO 9001 Cert. No. CS1-094/001 Derby