SUNSTAR 单片机专用电路 TEL: FAX: Features 6 Digit 6 Function LCD Alarm Watch with RGB LE

Similar documents
CW-5000/ 5200 INDUSTRIAL CHILLER USER MANUAL

LEVEL SENSORS & FLOAT SWITCHES

RAS-DX18HDK/RAC-DX18HDK

Portable Ionizing Air Gun PIA 型离子风枪 型号 : 94101

BT9290. English. 1 Make sure the appliance is switched off and the laser guide is in off position.

PolyBox TM. Edition II. Operation Manual

SOLARBOX Models 1500e RH and 3000eRH Accelerated xenon light fastness and weathering test chambers

所有的资料是按最新出版的产品资料编写而成遥科勒公司保留任何时候不经通知即可改变产品特性尧包装或产品可供类型的权利遥 说明书包括重要的安装内容袁请把这些资料交给用户阅读遥

"Three Preventions" System Design Based On Single-Chip Microcomputer SCM Control Jiaxiong Wen

2016 Koninklijke Philips N.V. All rights reserved 保留所有权利 (12/2016) > 75% 循环再造纸 BT9290. >75% recycled paper >75% papier recyclé

KMART Corrective Action Plan

DC MOTOR FAN COIL UNIT 直驅無刷电机风机盤管

Hitachi Highly. Spezifikation Manual

brass material mould. 500USD (2 pcs) Baby safety swab 500USD (2 pcs) Cosmetic swab brass material mould. 500USD (2 pcs) Cosmetic swab

Rosemount 214C Sensor. Quick Start Guide , Rev BB March 2019

Service Manual. Solar Direct Drive Vaccine Refrigerator / Freezer. Model :HTC-40/110; HTCD-90 Pictures :

FOB NINGBO PORT PRICE: 29,000USD

TSI FMS Particle Monitoring Applications TSI FMS 在线粒子监控系统的应用. 2008, TSI Incorporated

Question? 有疑问? Contact Philips 请联系飞利浦 FC6132 FC6130

HC1089 HC Koninklijke Philips N.V. All rights reserved 保留所有权利 (25/9/2017) > 75% 循环再造纸

Shaking Peltier Device

Register your product and get support at 在以下网站注册并获得支持

安装使用说明书. 维格一体化智能座便器 305mm/400mm 坑距 VOGUE INTELLIGENT INTEGRATED TOILET305mm/400mm RI 20127T-M-WK/20128T-M-WK

说明书 澳大利亚 ARTUSI KH90A-F1N160 薛孝田 印刷说明 : 2.. 此印刷品自 起开始实施 3. 此印刷品最终成品大小为 A4 纸一半大小 4. 此印刷品黑白印刷 5. 此印刷品要求字迹清晰 不能有漏印 错印 模糊现象 客户名称 产品型号 会签 型号经理

GreenUp Lowbay G2 BY288P. Lucia Liu Indoor Segment, PLP Growth Market Feb. 2016

R-S32EPH R-S32EPHL

Prospects and challenges for sustainable urbanization in China

Beijing Urban Design Studio Summer 2008

WARNING/CAUTION DESCRIPTION OF COMPONENTS FUNCTION EXPLANATION OPERATION INSTRUCTIONS CONTINUOUS DRAINAGE CAUTIONS MAINTENANCE/EMERGENCY

Senab Interior established on the Bund introducing Scandinavian design and new ways to organize the office

EJX-A and EJA-E Series Differential Pressure and Pressure Transmitters

Award-winning and absolutely new, Very stacks, swivels, and flexes far beyond ordinary seating to inject comfort and life into any space.

COMPARATIVE ANALYSIS AND PEDESTRIAN SIMULATION EVALUATION ON EMERGENCY EVACUATION TEST METHODS FOR URBAN RAIL TRANSIT STATIONS

Premium Desoldering station with Electric Pump Ref. DIS-D

Work Report of Chinese Steering Commi.ee of Landscape Architecture Educa8on

8 Filtration Systems Air Purifier 8 重過濾空氣清新機 User Manual 產品說明書

Always there to help you

TECHNICAL PRODUCT DATASHEET

EJX-A and EJA-E Series Differential Pressure and Pressure Transmitters

Dr. Qiaoling Luo. Publications

Cooker Hood User Manual

践行里约 +20 决议, 示范新型城镇化 : 国际人居环境范例新城倡议

美的吸尘器 使用说明书 VACUUM CLEANER OPERATION INSTRUCTIONS MANUAL C5 PRO (C5-L121D) 使用产品前请仔细阅读本说明书 并请妥善保管

Application of Distributed Fiber Optic Sensing Technology in the Transportation Engineering Monitoring

EJX / EJA-E series. For the description on the applicable page of users manual as shown in the item 1, please use revised information as shown in 2.

Collaborative efforts for sustainable campus 可持续校园建设多方协作机制的初探

Preparation. Name of Each Part. Safety Precautions (Be sure to always follow these precautions) ECLEAR MIST. HCE-HU03 Series. Turning the power on

IMPORTANT: Read carefully before assembly and use Techtronic Floor Care Technology Limited. All Rights Reserved.

Hot Air Station without Extractor desk Ref. JTSE-QA

YVP110 Advanced Valve Positioner. Please use the attached sheets for the pages listed below in the following manuals. IM 21B04C01-01E (10th)

compact Bagless Cyclonic Vacuum Cleaner IMPORTANT: Read carefully before assembly and use.

qianlong garden restoration project 乾隆花园修复工程

PE Series Jaw Crusher P E

AirFloss Ultra. 5_020_9188_2_DFU-Booklet_A6_v3.indd 1 21/09/16 09:11

The Home Depot Quality System Audit. * Example Report * North America Latin America

MultiTemp IV Thermostatic Circulator

New Rural Planning Guidelines in the Chengdu Plain: The Case of Tianfu New Area

TRANSPORTATION EXISTING 交通现状

Personal Care Appliances in Sweden

LEC TF55207W(CE-BCD275WM-SQ) 重量 (g) WEIGHT. 比例 scale 第页 NO. OF SHEETS

Contents. Precision Lead-free Reflow Oven. Model: AT-R3028

Automated Pressure Steam Sterilizer. Operating Instructions

Personal Care Appliances in Thailand

Periuk Nasi Elektrik Kegunaan di Rumah 白米饭 泰国香米 杂粮 快煮 糙米或糯米...25 蛋糕 / 面包...29 汤 / 慢煮...30 使用计时器...31 清洁和保养...32 如何使用可调节式蒸笼 / 屏显代码应对措施...

User Manual. OCTAVIUS Detector 729 (T10040) and Detector Interface 4000 (T16039)

PAC-10P PAC-15P. 移動座地式冷暖空調 Portable Reverse Cycle Air Conditioner 在使用之前請詳細閱讀 使用說明書 及 保用條例, 並妥為保存

Jiangbei New District, Nanjing ISOCARP Urban Planning Advisory Team Report

A New Generation of Active Intrusion Detection System for Physical Protection

丹麦,Fuglsang 美术馆 / Tony Fretton Architects

SC8130S /SC8136S /SC8130W /SC8136W SC8830BS /SC8836BS /SC8830BW/SC8836BW SC8130S /SC8136S /SC8130W/SC8136W SC8830BS /SC8836BS /SC8830BW/SC8836BW

Urban Models for the 21st Century

Technical Code for Engineering of Security and Protection System

KTT-109. Foldable Travel Kettle USE R MA NUA L GPU-6SSL GPNB-6SSL. 2-in-1 Free Standing Steam Oven

即熱式電熱水器即热式电热水器. Instantaneous Water Heater 使用說明書

Gas Pipeline Locating Leak detection and Safety Assessment

Rosemount 848T High Density Temperature Measurement Family

Boiler Safety Technical Supervision Administration Regulation

Ketuhar Elektrik Terbina Dalam Manual Pengguna. Built-in Electric Oven User Manual 嵌入式电烤箱用户手册

English (original instructions) 2 中文 ( 简体 ) 7 繁體中文 11 한국어 15. Copyright DeWALT

Kitchen Exhaust Duct (KED) Requirements

BUREAU VERITAS GREATER CHINA 必维国际检验集团 大中华区 CRANE SERVICES 起重机服务

WAT E R S O U R C E H E AT P U M P S

亚太地区世界遗产培训与研究中心 ( 上海 ) 简讯 World Heritage Institute of Training and Research - Asia and Pacific, Shanghai

Projects. Studio. Index. Office 2 Retail 28 Education and research 44 Residential 58 Mixed use 80 Arts and installations 100

SS IN 1 SMD HOT AIR REWORK STATION

Controller for Constant Temp. and Humidity Unit

CONTENTS. I Description II Specification III Structure IV Mounting and Wiring V Application VI Troubleshooting...

公司願景 業務項目 我們的願景是能為您帶來更加 健康 舒適 便利 的生活環境 水的控制專家 晴立實業 創立於 1993 年 十幾年來致力於排水器及週邊產品之研究與開發 多年來的創新及研發成果獲得多項產品專利, 深受各界的肯定, 於業界亦趨領導地位 為了服務客戶長久以來的支持,

RECENTLY, multicarrier modulation techniques, such

Operating and Installation Instructions

Ammonia Mercerization of Denim 牛仔布液氨絲光. The use of ammonia in mercerization has been known since the 1930 s and was developed

Operating and Installation Instructions

矿用电缆 矿 用 电 缆 江苏亨通电力电缆有限公司

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

RURAL URBAN FRAMEWORK Sample

Owner s Manual / 使用手冊

DIGITAL ARIA FRYER 電子控制無油煎炸鍋 MODEL NO.: GAF W A GILMAN GROUP BRAND

WPHO - LED HIGH OUTPUT WALL PACKS

Liebert DM Chilled Water Series User Manual. Precision Cooling For Business-Critical Continuity

AIR COOLER. Model: MAC-215F. Please read this manual carefully before running this air cooler and save it for reference.

Transcription:

Features 6 igit 6 Function LC Alarm Watch with RGB LE Backlight plit operative stopwatch(accurate to 1/100 ond) Hour, inuet, econd, onth and date normal display 6 digit chronograph: Auto ranging after 30 minutes to hour, minute, ond from minute, ond, 1/100 ond Alarm output for melody IC Alarm function with 4 to 5 minutes snooze User selectable 12/24 format & 4 year calendar Chime on every hour One touch correction of time error within ±30 onds Oscillating built-in capacitor irect drive of piezo buzzer RGB LE Backlight with 3 onds delay function 特点 跑表有分段计时功能 ( 准确至 1/100 秒 ) 显示时 分 秒 月 日及星期 6 位计时器 : 以分 秒 1/100 秒显示方式, 计满 30 分后自动转换至时 分 秒 可接音乐电路芯片作音乐闹铃输出 具有 4~5 分钟再闹功能 整点发声报时 可选用 12 或 24 小时制 ;4 年日历 按键一次可校正 ±30 秒时间误差 振荡器内置电容 直接驱动压电蜂鸣片 RGB LE 背光,3 秒延迟功能 ELECTRICAL CHARACTERITIC 电特性 Characteristics ym in Typ ax Unit Remarks Operating Voltage 工作电压 V 2.2 3.0 3.6 V Quiescent Current 静态电流 I B - - 2 ua No Load Input High Voltage 输入高电压 V IH V -0.3 V V Input Low Voltage 输入低电压 V IL V V +0.3 V wich Activation Current 按键开关消耗电流 I W 3 ua V IN =V Oscillating tart Voltage 振荡起振电压 Within 3 V OC 1.3 V onds Alarm rive Current 闹铃驱动电流 I ALA 0.5 2 ma V ALA =0.5V Oscillation Frequency 振荡频率 F OC 32768 Hz ±30% Tol LC Frequency LC 频率 F LC 32 Hz Time tability 时间稳定度 T TB 1 ppm V =0.3V Page 1 of 7

APPLICATION INFORATION 应用资料 Pad No Name Pad No Name Pad No Name Pad No Name 1 OCI 13 A1_U 25 T1 37 B4_C4 2 OCO 14 C1_B1 26 38 G4_4 3 LN 15 A2_ON 27 39 F4_E4 4 L 16 CL_TUE 28 T2 40 B3_C3 5 L1 17 A3_WE 29 T0 41 G3_3 6 L2 18 A4_TUH 30 V 42 F3_E3 7 L3 19 A5_FRI 31 B6_C6 43 B2_C2 8 V 20 A6_AT 32 G6_6 44 G2_2 9 ALA 21 TE_AL 33 F6_E6 45 F2_E2 10 22 CO1 34 B5_C5 11 CO2 23 T3 35 G5_C5 12 P_A 24 AC 36 F5_E5 注 :1 芯片底部接 V 2 T0 到 T3 为测试端 3 CO&EGENT to LC 的顺序与 A5190 完全相同 4 发光二极管控制端(ON) 按住不动时,3 个二极管以 2 秒速度变化出 7 种颜色和快速扫描 在任何一种状态下 ON 端松开, 此种状态被选中并存档, 三秒后熄掉, 以后每按一次 ON 键, 被选中状态亮 3 秒 如果需要改变被选 中的状态, 重复以上过程 LC Format CO2 P/A AEG1/UN C1/B1 A2/ON COLON/TUE A3/WE A4/THU A5/FRI A6/AT ATE/AL CO1 A P U O TU WE TH FR A COLON RTE F2/E2 G2/2 B2/C2 F3/E3 G3/3 B3/C3 F4/E4 G4/4 B4/C4 F5/E5 G5/5 B5/C5 F6/E6 G6/6 B6/C6 Page 2 of 7

IC Pad No CO1 CO2 IC Pad No CO1 CO2 11 CO2 31 B6 C6 12 P A 32 G6 6 13 A1 UN 33 F6 E6 14 C1 B1 34 B5 C5 15 A2 ON 35 G5 5 16 CL TUE 36 F5 E5 17 A3 WE 37 B4 C4 18 A4 TUH 38 G4 4 19 A5 FRI 39 F4 E4 20 A6 AT 40 B3 C3 21 TE AL 41 G3 3 22 CO1 42 F3 E3 43 B2 C2 44 G2 2 45 F2 E2 Page 3 of 7

ETTING EQUENCE AN WITCH OPERATION NORAL * TOPWATCH ALAR TIE ETTING *When or is used in the stopwatch mode or the alarm time setting mode the normal mode is obtained by depressing. * TIE/CALENAR ETTING Reset econd Reset HR:IN EC* inute et HR:IN*EC Hour et HR*:IN A/P:(12 hr) HR:IN H(24hr) ate et O ATE* NORAL Alarm inute HR*:IN A/P (12hr) HR*:IN H (24hr) Alarm monute set HR:IN *A/P (12hr) HR:IN *H (24hr) *12HR mode or 24HRmode is selected alternatdly on every 24*hour cycle during hour advance isplay stopped Time IN EC 1/100 HR:IN EC start stop isplay counting IN EC 1/100 HR:IN EC isplay stopped time Lap start isplay lap time IN EC 1/100 HR: IN EC stop isplay lap time IN EC 1/100 HR:IN Ec Release *Colon flashes at a 1Hz rate when the stopwatch is running Time display HR:IN EC & Calendar display O ATE onth set O*ATE isplay alarm time & disactivate alarm out put HR:IN A/P (12hr) HR:IN H(24hr) isplay alarm time & alarm enable/ disable alarm demonstrate HR:IN A/P (12hr) HR:IN H(24hr) set * O ATE *Flashing at 2Hz rate means date-mark isplay alarm time & chime enable/ disable day-of-week* HR:IN A/P (12hr) HR:IN H(24hr) * denotes date-mark *Alarm-mark appears in any mode when the alarm is enabled. *All day-of-week mark appear when the chime is enabled. Page 4 of 7

PA Assignment and Location The IC substrate should be connected to V in the PCB layout artwork Pad No. Pad Name X Y Pad No. Pad Name X Y 1 OCI -698.90-392.80 24 AC 699.10 387.00 2 OCO -698.90-267.95 25 T1 699.10 262.20 3 LN -698.90-143.20 26 699.10 137.40 4 L -698.90-18.40 27 699.10 12.60 5 L1-698.90 106.40 28 T2 699.10-112.20 6 L2-698.90 231.20 29 T0 699.10-237.00 7 L3-698.90 387.00 30 V 699.10-360.50 8 V -698.90 511.80 31 B6_C6 699.10-486.60 9 ALA -698.90 636.60 32 G6_6 699.10-611.40 10-698.90 761.40 33 F6_E6 699.10-761.40 11 CO2-556.75 761.40 34 B5_C5 574.15-761.40 12 P_A -431.50 761.40 35 G5_5 449.75-761.40 13 A1_UN -307.35 761.40 36 F5_E5 324.80-761.40 14 C1_B1-181.80 761.40 37 B4_C4 199.90-761.40 15 A2_ON -57.25 761.40 38 G4_4 75.15-761.25 16 CL_TUE 66.90 761.40 39 F4_E4-49.55-761.40 17 A3_WE 192.70 761.40 40 B3_C3-174.65-761.40 18 A4_TUH 317.00 761.40 41 G3_3-299.25-761.40 19 A5_FRI 442.00 761.40 42 F3_E3-424.10-761.40 20 A6_AT 566.35 761.40 43 B2_C2-548.90-761.40 21 TE_AL 699.05 761.40 44 G2_2-698.90-761.40 22 CO1 699.10 636.60 45 F2_E2-698.90-611.40 23 T3 699.10 511.80 Page 5 of 7

Recommend Appliaction Citcuit 参考电路图 LC CO2 P_A A1_U C1_B1 A2_ON CL_TUE A3_WE A4_YUH A5_FRI A6_AT TE_AL ALA CO1 V L3 T3 AC 0.1u L2 L1 L LN C6292 IC 衬底接 V T1 T2 T0 32768Hz OCO OCI V B6_C6 F2_E2 G6_6 G2_2 B2_C2 F3_E3 G3_3 B3_C3 F4_E4 G4_4 B4_C4 F5_E5 G5_5 B5_C5 F6_E6 : 建议邦定时, 请调校邦机到适当超声焊接压力 ( 推荐压力调校值在 15g~18g 左右为宜 )! Page 6 of 7

Other Appliaction Citcuit 其它电路图 LC CO2 P_A A1_U C1_B1 A2_ON CL_TUE A3_WE A4_YUH A5_FRI A6_AT TE_AL ALA CO1 V L3 T3 AC 0.1u L2 L1 L LN C6292 IC 衬底接 V T1 T2 T0 32768Hz OCO OCI V B6_C6 F2_E2 G6_6 G2_2 B2_C2 F3_E3 G3_3 B3_C3 F4_E4 G4_4 B4_C4 F5_E5 G5_5 B5_C5 F6_E6 : 建议邦定时, 请调校邦机到适当超声焊接压力 ( 推荐压力调校值在 15g~18g 左右为宜 )! Page 7 of 7