Axiom Technologies L.L.C Telephone: Pennbright Dr., Suite 220 Fax: XP7 USER S MANUAL

Similar documents
Model 17A00 Expansion Enclosure

Dual Column Dehydrating Breather Manual

918 Clock Gauge Installation, Operation, and Maintenance Instructions

RK CO 2 Transmitter Operator s Manual

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

MODEL 5100 VOTING LOGIC MODULE

INTRODUCTION / TABLE OF CONTENTS

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

Sierra Series 900 Single & Dual Channel System. Instruction Manual

Basic Vehicle Fire Protection Manual

B-40/B-41 Modulating Temperature Controller

Analog Room Pressure Monitor RPC Series

ANSUL ANSUL AUTOMAN II-C RELEASING DEVICE

BENTEL SECURITY reserves the right to modify the technical features of this product without prior notice.

RK Hydrogen Sulfide Transmitter Operator s Manual

ECO N DATE DESCRIPTION OF CHANGE CHG

FlashGuard 3000B Dual Lighting System Troubleshooting Guide

RK-05 Combustible Gas Transmitter Operator s Manual

Fisher LCP100 Local Control Panel

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

Sitron s CF Line of Flow Switch Monitors

Heat Pump Defrost Board Replacement Kit

RK-03 Hydrogen Detector Operator s Manual

Installation, Operating and Maintenance Manual

CT-7 Series Toxic Gas Transmitter Operator s Manual

Across-the-Line SERIES MP300 Combined Manual and Automatic

1126 Series Ceiling Mount PIR Motion Detector

RK/ RK Oxygen Detector Operator s Manual

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

BERMAD Fire Protection

Table of Contents 1. OVERVIEW SYSTEM LAYOUT SPECIFICATIONS FUNCTION... 11

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Install Guide 8046 ENGLISH. Customer Support: or: visit our website Printed in China ON.

MODEL B2 INSTALLATION MANUAL

ANSUL AUTOMAN II-C EXPLOSION PROOF RELEASING DEVICE Installation, Operation, and Maintenance Manual

M2000 Engine Controller

AS DIGITAL FIRE PUMP CONTROLLER

RK/ RK Carbon Monoxide Detector Operator s Manual

Carbon Monoxide Transmitter

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

AUTOTROL 363TC AUTOMATIC FILTER VALVE SERVICE MANUAL

Install Guide Customer Support: or Visit our website

Soft Start Series MP700 Solid State, Reduced Voltage

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

Model TG 1000 External Toilet Water Shut-Off Valve User Manual

FLT93 Installation, Operation and Troubleshooting Guide

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Beacon 800 Gas Monitor Operator s Manual

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

GUIDE BOOK FROSTIE FROST FIGHTING CONTROLLER

RF280THS. Installation Instructions Wireless (RF) Photoelectric Smoke Detectors

CHECKFIRE 210 Detection and Actuation System

Installation Instructions

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

EL-TSTAT-8820 Safety & Installation Instructions


EC Series Wall Unit Humidifier

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

Installation Instructions Azatrax Dual Infrared Model Train Detector MRD2 'Turnout' Edition

RK/ RK Oxygen Detector Operator s Manual

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

Troubleshooting Guide For FG3000 Dual Medium Intensity Lighting System

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

WARNING This is a Warning statement that is related to the use of this heater. These statements warn of actions that may result in physical injury.

RK / RK Methane Detector Operator s Manual

Caliber Series LED Edgelit Exit Sign EXPORT AC Only or Emergency Operation READ AND FOLLOW ALL SAFETY INSTRUCTIONS

STEAMPRO. Steam Generator Troubleshooting and Service Guide

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

RK Carbon Monoxide Transmitter Operator s Manual

Installer manual AG-WL10

IMPORTANT SAFETY INFORMATION READ ALL...

1125 PIR Motion Detector

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

Remote NAC Power Supply D7038

Ethernet General Purpose

RK-02 Multi Point Detector Operator s Manual

PRE-ASSEMBLED RADIANT CONTROL PANEL INSTALLATION MANUAL

LMS-188-4P-BMS 4 POINT DIGITAL MONITOR/ALARM WITH PROTOCOL CONVERTER OPERATING INSTRUCTIONS

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

OPERATION MANUAL KP4041 POLY SCRAP COMPACTOR

Thermostatic bar mixer valve with adjustable head Installation guide

WM3000 WIRELESS MODULES

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

ACL TC 200 TEMPERATURE CONTROLLER

Tox-COMB/ANA Combustible Gas Transmitter Operator s Manual

Instruction Manual for Electric Ovens OO757X OO986X

D3000. Installation & Setup Guide

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

Pump-Down Controller MODEL 4052

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

Instructions for TA HR 2 Shear Rheometer 6 November 2013

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

Transcription:

L.L.C Telephone: 281 931 0907 255 Pennbright Dr., Suite 220 Fax: 281 931 6562 Houston, Texas 77090 www.axiomsafety.com XP7 USER S MANUAL COMPACT MULTI-CHANNEL ALARM & SHUTDOWN SYSTEM

GENERAL The XP7 alarm and shutdown system is a self-supported, compact shutdown device that has been designed to provide a safe and reliable mean to detect abnormal conditions on a production process and initiate a shutdown if any of the reading shows the operation is no longer within the pre-set safety margins. The system has been built to withstand the adverse conditions of the oil-field environment and provides a straightforward interface with the operator. Abnormal conditions are indicated by indicator lamps (LEDs), each associated with a label indicating the condition detected. Powered by lithium batteries, the system is expected to operate for about three years without replacing batteries and there is little or no maintenance needed besides recommended periodic function testing and gentle cleaning of contact points. In addition to the High and Low pressure alarms associated with the bourdon assembly included in the box, the XP7 can connect up to four (4) loop monitored external alarms plus two solid state outputs for indicating shutdown and service needed respectively. The external alarms channels can be connected to any dry contact (or open collector ) type of sensor such as pressure or level switches, manual ESD station, telemetry shutdown commands etc. Each remote loop is monitored for wire integrity for insuring that wiring faults are also detected. Field Connection Box (Four Input and two output Channels) Reset Test Switch Indicator LEDs Solenoid Valve Low Pressure Alarm Setting Fig. 1 XP7 General Layout Pressure Sensing Port High Pressure Alarm Setting Manual_XP7_Rev2017.doc September 21, 2017 Page 2 of 9

INSTALLATION Typically, the XP7 is shipped with the battery module installed in the storage position for shipment. Remove the four studs holding the battery module, rotate it 180º and carefully re-install as shown on page 9 of this manual. The XP7 is now energized and the green LED blinking every second. The unit can be wall mounted or mounted directly on the process line. The box has a drain at the bottom to remove water condensation. Do not mount the XP7 sideways or upside down as this may allow rainwater to ingress and accumulate in the enclosure. NOTE: XP7 DEVICE IS TO BE MOUNTED UPRIGHT IN THE VERTICAL POSITION ONLY. XP7 / Pressure Sensing Monitored pressure (i.e. flow-line pressure) is to be connected to the Sensing Port. Sensed pressure is not to exceed 10% over full scale as this would cause damage in the instrument and void warranty. If the flow is prone to pressure spikes, a pulsation dampener is to be installed between the sensing port and sensed fluid. It is recommended that an isolation valve is installed between the sensing port and process to allow for maintenance and testing. NOTES: Do not exceed rated range. When connecting pressure bourdon assembly (bottom of XP7), pipe dope or use Teflon tape on connection threads. Use wrench on shank to tighten or loosen bourdon connection. Do not twist case when installing, this will cause damage and void warranty. Do not overtighten. The typical connection the solenoid valve is as follows: Port 1 (normally closed) Port 2 (common) Port 3 (normally open) Supply Pneumatic Pressure (100 PSI Typ.) Actuator Exhaust Port No. 1 - Pneumatic Supply (100 PSI Typical) Port No. 2 - To Actuator. Port No. 3 - Exhaust Note: Port numbers are stamped near the ports Fig. 2 Solenoid pneumatic/hydraulic typical connection Manual_XP7_Rev2017.doc September 21, 2017 Page 3 of 9

Adjusting High and Low Pressure Alarm The Low Limit contact is controlled by the knob on the left, while the High Limit contact is controlled by the knob on the right. To set the limit contact, simply turn the knob to the desired position in the scale. Connecting Remote Sensors As indicated before, the XP7 can connect up to four (4) external alarm sensors and each external loop is independently monitored for detecting alarm conditions. In addition to the above, the unit monitors the wiring integrity for wiring interruption, insulation degradation, etc. Each alarm loop is non-incendive. Each input channel has an End Of line Zener (EOZ) that is to be connected in parallel with the sensing element. For example, if channel 3 of the field alarms is to be connected to a level switch installed on a water tank, then the EOZ is to be removed from the XP7 junction box and connected in parallel with the level switch as shown in Appendix A. Inputs (4) Outputs (2) Common Fig. 3 Field Connection Box for non-incendive field wiring (See Appendix A for field wiring details) When in normal operation, the XP7 sends short pulses of current to the remote sensors to verify wiring conditions and the existence or absence of alarms. Manual_XP7_Rev2017.doc September 21, 2017 Page 4 of 9

With the EOZ, the input should have a voltage between 7 and 7.5VDC, however, given the shortness of the pulse, this voltage cannot be verified with a regular voltmeter. To overcome the above difficulty, the XP7 offers a mode where the inputs are energized for a few seconds at a time by following the procedure below: - Open junction box and have voltmeter ready for reading voltage - Press and hold the Test Reset switch down to Test for about three seconds and then release. - The first remote alarm blinks the corresponding LED for five seconds while the input is sending a current to the field connection. - Read the voltage on first remote channel and confirm it is between seven (7) and seven and a half (7.5) volts (around 7.3V being typical). A voltage below three (3) Volts is considered as alarm. - Voltages above 8 VDC indicate the remote sensor is not connected or an EOZ (End Of line Zener) is missing - A reading of about 0 VDC may indicate the corresponding sensor is close, or there is a short circuit in the loop or the XP7 timed out the test on that channel. - A low voltage of about 0.5VDC may indicate the EOZ (End Of line Zener) has been connected backwards. - Other low voltages (between 3 and 5 VDC) may indicate insulation s deterioration in the field wiring. - Once the XP7 stops the blinking the first channel and moves to channel 2, repeat voltage reading. OPERATION The system can be commanded to Reset or Test by pressing the toggle switch up or down respectively. By pushing to Reset the operator commands the unit to return to the flowing condition. Pushing the Test function allows the operator to see the last recorded cause of shutdown (corresponding LED blinks fast) and then the system proceeds to slow blink each red LED to confirm all indicator circuits are operating normally. The system is shipped in the RESET condition. The needle of the gauge touching either the Low or High set point causes the XP7 to switch the solenoid valve into shutdown. The corresponding alarm LED will blink once a second to indicate the actual cause of the shutdown even if the alarm goes away or another alarm is later detected. EXAMPLE. If an XP7 senses a High Pressure in a production line it will cause a shutdown and the High Pressure LED will blink. After a number of hours, because of the shutdown, the sensed pressure may fall to the point where the high pressure clears and the needle of the gauge is now touching the low pressure alarm. In this case the XP7 continues flashing the High Pressure alarm LED until the operator presses Reset. If the operator wants to confirm the cause of alarm after the system is back to normal, they Manual_XP7_Rev2017.doc September 21, 2017 Page 5 of 9

just need to press Test and the XP7 will blink the High Pressure LED to show the last recorded cause of shutdown. After the XP7 is installed, the operator is to set the high and low alarm settings and open the isolation valve to allow pressure into the sensing port. If the operator presses Reset, any existing alarm will be ignored for 30 minutes to allow the process to return to normal; there is no need to disturb the set-point before restoring the process. It is recommended not to move the set points out of the alarm condition as this involves the risk of the operator forgetting to return the alarms to the proper setting once the process returns to normal. If more than 30 minutes is needed, then it is suggested that the operator press Reset again before the time expires, re-starting the 30 minute countdown. If the pressure returns to normal before the 30 minutes expires, the XP7 will re-arm itself and will initiate shutdown again if an alarm is sensed. Time Delay on Alarm Inputs In some cases, it may be desirable to have a slower response to a given alarm channel, e.g. a tank level sensor may respond to waves or fluid motion in a tank. The XP7 offers the capability of introducing an eight (8) seconds delay on any of the four remote alarm channels. For setting a time delay in any of the four field inputs, proceed as follows: 1- Open XP7 enclosure 2- While holding the Test Reset switch down, momentarily depress the Initialize pushbutton on the controller board (upper left corner as shown on Fig 4, Page 7) and then let go the Test Reset switch. The green LED responds by flashing rapidly for a few seconds. 3- Next, the XP7 flashes the first field alarm LED, rapidly to show that there is no time delay set, slowly if a time delay exists. 4- If the flashing indicates the desired setting, then take no action and the XP7 will move to the next channel. 5- If a time delay is desired and the LED is flashing rapidly, press the Test Reset down to set a time delay. 6- If a time delay is not wanted and the LED is flashing slowly, press the Test Reset up to remove the time delay. 7- As the XP7 moves on to the next channel, repeat step 4 through 6 for setting the desired operation mode. 8- Once all channels have been set, the operator may repeat step 2 and confirm each channel has been set correctly. 9- Close the enclosure and confirm the actual delay by tripping the alarm channels and observing the response on the XP7. Manual_XP7_Rev2017.doc September 21, 2017 Page 6 of 9

Fig 4 Initialize Pushbutton MAINTENANCE The XP7 requires little maintenance but a minimum of a monthly visual examination and testing is recommended to insure that the unit as well as the systems and devices associated with the safety shutdown are operating properly. It is recommended that once a year the gauge pointer and High and Low limit points be cleaned with a soft piece of cloth and a non residue contact cleaner to insure optimum performance. Note When cleaning contacts do not use abrasives materials or fluids as they will cause damage and severely reduce system s reliability. Note Avoid opening the enclosure in a rainy or dusty environment. The batteries are expected to have a life of about 3 years before replacement is needed. The XP7 routinely reads battery voltages and provides warning if the batteries need replacement. When the batteries are beginning to go low the XP7 will alternatively blink the green and Lo Batt LEDs to indicate that battery replacement is needed. If the batteries are not replaced within a few days the XP7 will blink only the Lo Batt. LED and initiate shutdown as further reduction in voltage may prevent the system from protecting the process. Manual_XP7_Rev2017.doc September 21, 2017 Page 7 of 9

WARNING - EXPLOSION HAZARD BATTERIES MUST ONLY BE CHANGED IN AN AREA KNOWN TO BE NON-HAZARDOUS. REPLACE BATTERY MODULE WITH AXIOM TECHNOLOGIES PART NUMBER AT-LBP-36144. WARNING DO NOT ATTEMPT TO RECHARGE BATTERY MODULE AS THIS MAY TRIGGER AN UNSTABLE CONDITION WITHIN THE LITHIUM CELLS AND CAUSE AN EXPLOSION Return used battery modules to for safe disposal. XP7 - ENVIRONMENTAL SPECIFICATIONS Temperature range : -40 to +85ºC Humidity range : 0 To 95% max., non condensing Altitude : 2,000 m. max. Hazardous Area Classification : Suitable for Class I, Division 2, Groups C & D, Hazardous Locations. Temp. Code T3C XP7 - PRESSURE RATINGS Sensing Pressure : Ranges of up to 20,000 psi max Solenoid Valve Pressure : 100 psi max. (standard), up to150 psi available XP7 - ELECTRICAL RATINGS Electrical Source : Dual voltage lithium battery module 3.6 & 14.4 VDC Current consumption : 285 ma max. on 3.6VDC Circuits 435 ma (3 A max. pulse) on 14.4VDC Circuits Manual_XP7_Rev2017.doc September 21, 2017 Page 8 of 9

PLACING THE BATTERY MODULE Fig. 5 Remove screws from cover Fig. 6 Open front cover Fig. 7 Align the battery module with threaded studs and push it in place gently. The Axiom Technologies printing on the module is to be on the left. Fig. 8 Secure battery module by reinstalling nylon spacers. Verify the green LED blinks about once per second to confirm successful battery module installation. Manual_XP7_Rev2017.doc September 21, 2017 Page 9 of 9

1- The XP7 operates with normally open contact and contact closure indicates that an alarm is 5- present. 2-3- Appendix "A" - XP7 Installation Notes For supervising field wiring, each input channel is provided with a 7.5V "End Of line Zener" (EOZ) at the XP7's input terminals. At the time of installation, the EOZ is to be moved to the end of the loop and connected in parallel with the alarm switch. If more than one switch are daisy-chained, then the EOZ is to be installed at the very last switch. The EOZ at the end of the alarm wiring allows the XP7 to confirm the wiring's integrity. The EOZ must be connected in the correct polarity, Blue wire to "Signal" and White wire to "Common". Connecting the EOZ on a reverse polarity will cause the corresponding channel to stay on alarm. 4- The alarm switch may be located at 3,000FT or more from the XP7 6-7- Each input sends a pulse of 14VDC to the alarm switch. If the EOZ is connected (as it should), then the voltage is cut down to 7.4VDC (+/- 0.3VDC) and the XP7 accepts this voltage as a normal condition. If the EOZ would be missing or the wiring to the alarm switch disconnected, then the voltage may rise up to about 14VDC which is considered a "Wiring Failure" and cause a shutdown. Multiple XP7s may share a single alarm switch such as a tank level, ESD station or any "dry contact" alarm switch. The output of an XP7 can be used as input for another XP7, or MI6 or MX16. Make sure the EOZ is properly connected for wiring supervision. XP7 Junction Box SIGNAL INPUTS SIGNAL COMMON S.D. COM TRBL COM 1 2 3 4 1 2 3 4 Unused channel keeps EOZ connected to Field Wiring End-Of-line Zener (EOZ) on each input Typical of 4 supplied with XP7 EOZ must be removed and installed with remote alarm switch as shown on channels 1 through 5 of this sheet MUST BE CONNECTED FOR WIRING FAILURE ALARM TO GO AWAY! Polarity IS Important! R1 - Malfunction + 12 or 24 VDC source - Red Blue R2 - Shutdown blue Black Blue Wire goes to "Signal" White Wire Nuts EOZ (End Of line Zener) To be connected as shown white High Level Switch White Wire goes to "Common" Control panel, external to the XP7 (Example Only) XP7 Wiring Diagram Monitored Inputs for Safety Shutdown System (External Hi-Lo Pressure Switchgage) (High Tank Level) Reference: Sheet: Rev: Date: XP7 1 of 1 1 2/28/2011