A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

RTM / & 01/ / RTM

Environmental, Pollution & Security Monitoring. Radiation Protection & Nuclear Security. Radon, Thoron, Daughter Products & Radioactive Aerosols

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

ß-Aerosolmonitor FHT 59 C

Thermo Scientific Aerosol Monitor FHT 58 S Technical Specification ZT-221E

stationary dose rate measuring systems

Radiation Monitoring System RMS

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

icam -HD High Flow Rate Alpha/Beta Air Monitor Radiation Safety. Amplified. DESCRIPTION KEY FEATURES BENEFITS OPTIONS

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

Portable Survey Instruments NISP-RP-01

Nuclear Associates

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE

Identify the following features and specifications for the ESP1

Scientific Production Company Doza. Radiation monitoring equipment

Radiation Monitoring Systems

North American Technical Services

SVG 2 and Probes. Innovation with Integrity. The new Generation of Semiconductor Radiation Meters and Handheld Radiation Detection Probes

Portable Instruments For First Response & In-Situ Analysis of Radiation

A Continuous Air Monitoring Sampler for 125 I - RIS-125

Quality and Technology - Made in Germany -

Detecting Radiation. Protection through Detection. February Animations in this training work best in Windows XP

Application Note. Application Note for BAYEX

Alpha Spectroscopy. Vacuum Light. Important things to know before you load your samples:

SEAWATER RADIATION DETECTION SYSTEM WATER PROTECTION

Using the GammaRAE II Personal Radiation Detector

COMPANY PROFILE. DETECTION & MEASUREMENT OF IONIZING RADIATIONS RADIOLOGICAL MONITORING SYSTEMS HEALTH AND ENVIRONMENTAL SAFETY

Kata products Kata DGM-1500 Turva

Pico Envirotec Inc., CA & ENVINET a.s., CZ NEW APPROACH TO GLOBAL MONITORING OF THE RADIOLOGICAL SITUATION; INDUSTRIAL, ENVIRONMENTAL & EMERGENCY

Product data sheet Palas Fidas 200 S

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S)

Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One. Firmware Version 3.00 D August 2006

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

PORTABLE or FIXED PERSONNEL & VEHICLE MONITOR

COMPACT RADIOACTIVE AEROSOL MONITORING DEVICE FOR EARLY WARNING NETWORKS

Introduction...1 Specifications... 1 Limitations... 1

Fundamentals is subdivided into Sources of Radiation, Biological Effects, Mathematics, Chemistry, Physics, and Units and Terminology.

Development of high sensitivity radon detectors

Measurement Devices. Topic 5 - Audio 56

Measurement system for detection of Radon in building

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

Radiation Monitoring Equipment

AERIAL RADIATION & CHEMICAL DETECTION SYSTEM. DroneSENSOR TM Series. Particulate Alpha, Beta, Gamma & Airborne Chemicals

ISO 3999 INTERNATIONAL STANDARD. Radiation protection Apparatus for industrial gamma radiography Specifications for performance, design and tests

Dosimeters/Survey meters

Radiation Alert Frisker INTERNATIONAL

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

P U B L I C N O T I C E

Turnkey Solutions for Radiation Protection in PET Laboratories R A D I A T I O N P R O T E C T I O N

AERIAL RADIATION DETECTORS

Instruments and Consumables

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor

HSD Dry Cabinet. Outstanding performance

portable gas analyser

Laboratory Impex Systems Ltd

Battery-operated, hand-held alarm and measuring instruments for radiation protection

Contamination Meter Users Manual

Our Extended Personal Electronic Dosimeter (PED) Family

Canberra icam: the worldwide alpha/beta air monitoring solution. James Forde-Johnston EMS Product Manager Japan User Group Meeting

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Comprehensive applications of the gas flow proportional counters for Radiological Surveillance

MSD Cabinets. Modular Dry Cabinet. Outstanding performance

RadEye N / NL Personal Highly Sensitive Neutron Radiation Detector

Dräger X-am 7000 Multi-Gas Detection

LAUNDRY MONITORING SYSTEM Model # LIM-64S

VIBRA-series: VIBRA, VIBRA +

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter

RadEye B20 RadEye B20-ER Multi-Purpose Survey Meter

POSITRON EMISSION TOMOGRAPHY (PET) CENTER MONITORS

Dynamic Radon Detection Over Measurement

TRITIUM IN WATER MONITOR REAL TIME CONTINUOUS Model # LIQ-X-(H3)

Environmental radioactivity surveillance system of ANPA

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

HSD Dry Cabinet

RIID capability in the palm of your hand

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020

Danfoss gas detection units

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020

metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD.

Detectors used in the intercomparison

requirements. Serial: USB or RSXXX Bluetooth GPS/GSM Ethernet Standard or rugged desktop or laptop PC or tablet; Android smartphone or tablet

RAM GAM-1C Gamma Survey Meter TYPE TEST

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

ELD500 PRECISION LEAK DETECTOR

CONTAMINATION MONITORING INSTRUMENTATION RCT STUDY GUIDE LEARNING OBJECTIVES:

Laboratory Refrigerator/Deep Freezer TC 802

INTERNATIONAL STANDARD

HSD Dry Cabinet. Outstanding performance

Drying and heating chambers

RAM GENE / RAM GENE-1

INTERNATIONAL JOURNAL OF RESEARCH SCIENCE & MANAGEMENT

Transcription:

Aer 5200/5300 Portable Alpha/Beta Continuous Online Air Monitor (CAM) The Aer5200 monitors continuously the ambient air to detect airborne radioactive aerosols (LLRD). Typical application fields are nuclear facilities, the NORM industry, mines and nuclear medicine (e.g. DIN ISO 16639 / VDE 0493-1-6639). The aerosols will be deposited on the surface of a filter by the internal pump and will be analysed by spectroscopy. The natural background due to Radon and Gamma irradiation will be fully compensated. The Aer5200 is instantly ready for operation after powering. The intuitive touch screen operation and the straight forward menu structure allow the operation even by unskilled staff. The ergonomic design, big wheels and low weight makes it easy to relocate the instrument if required. The stylish unit with plain surfaces can be easily de-contaminated. The pump works very quiet. The open face air inflow, in combination with a regulated flow rate ensures a uniform and low-loss deposition of the aerosols on the filter surface. The large active filter diameter and the long filter tape used in the filter stepping unit results in outstanding operation periods without intervention. The unique mechanism for dynamic filter sealing avoids leakages as present in conventional movablefilter solutions. Optionally, the unit may be equipped with a vacuum adapter (KF/DN16) to connect sampling pipes or flexible tubes. Particle losses at the inlet become negligible by the special construction. Contaminated filter pieces can be cut out easily for further analysis due to the quick stepping drive access. All parameters, necessary for proper operation are monitored continuously and are part of the stored measurement data. A flexible alert system warns the user in case of the exceedance of a threshold or any deviation from the regular operation mode. The Aer5300 offers a detector/filter unit separated from the body of the instrument. This allows the user to place the sampling head independently under conditions with limited space. There are many options for additional detectors/sensors (e.g. NaI probe with nuclide identification) and system integration.

Aer 5200 Technical Data Detector Sampling Filter/Stepper Pump 1200mm² ion-implanted silicon detector Option G : double detector for dynamic Gamma background compensation Energy range 80keV...3MeV (Beta); 3 10MeV (Alpha) Counting efficiency (4π) approx. 20% Open face sampling for minimum collection losses Standard version with open face sampling (free inflow of ambient air) Option S : Air inlet by a vertical standard vacuum pipe connector (KF/DN16) and filter stepping unit for stack monitoring Option F : manually changeable filter (d = 47mm) instead of the filter stepping unit Membrane filter tape (PTFE); 5µm pore size; length 30m; width 65mm; good for more than 300 filter steps Deposition rate >99,9% Active filter test with respect to perforation and exhaustion Tool-less replacement of filter coils More than 12 month autonomous operation in normal environment Configurable trigger for filter stepping (e.g. each sample interval, fixed period, filter exhaustion, activity detected) Required period for filter replacement <2s Oil-less, long-life, low noise quality rotary van pump (Becker) Nominal air flow 35 SLPM (adjustable range 30 to 50 SLPM) Processor controlled air flow for constant deposition conditions (mass flow sensor) Pressure drop across the filter 15 100mbar (at 35 SLPM) Noise emission approx. 51dBA (in 1m distance)

Results Exposure for Alpha and Beta emitters (LLRD) in Bqh/m³ Dose for Alpha and Beta emitters in µsv or DAC-hrs (dose coefficients adjustable by user) Detection of Natural Uranium with automatic selection of the U nat dose coefficient Average activity concentration for Alpha and Beta emitters in Bq/m³ Equilibrium Equivalent Concentration (EEC) for Radon and Thoron daughter products in Bq/m³ Separate channel for Alpha gross counting in cps or Bq Option: dose rate in µsv/h Temperature, humidity, pressure, battery voltage Flow rate, filter exhaustion, filter stepping, end of filter tape Signals Alert, Warning, Good Standards IEC 60761-1 IEC 60761-2 IEC 61578 IEC 61577-3 IEC 1263 CE, VDE DIN ISO 16639 (VDE 0493-1-6639) Compensation LLRD Sensitivity Measurement range Measurement s Compensation of natural Radon background by Alpha spectroscopy with dynamic fitting of peak shape with respect to progressive filter exhaustion Upper Alpha energy threshold for LLRD = 5,6MeV Static compensation of Gamma background Option: dynamic compensation of Gamma background by double detector Dynamic shock rejection (mechanical shock) by pulse signal shape analysis approx. 25cpm/(Bqh/m³) 10000Bqh/m³ (50000DACh(Pu)) 0.6MBq/m³ over 1 minute Up to 16 user definable sampling cycles (1s to 1year) Predefined sampling cycles 1, 5, 15, 60 minutes Predefined test cycles See tables below

Alert indication Data storage Handling Interface Power supply Housing Ambient conditions Configurable alert thresholds for all measured results Alert tower with green, yellow and red light, 360 visible 90dB signal buzzer Alert indication at display Alert reset is configurable (either with confirmation by the user or automatic reset if the alert condition is no longer present) Pre-defined alerts for LLRD activity, low/high count rate, filter perforation, end of filter tape 2GB SD card (> 1,200,000 data records) Storage of all measured raw data incl. spectra Touch screen 6cm x 9cm (4.5 ); Graphic 240 x128 High contrast even in direct sunlight Backlight Key switch Intuitive, straight forward menu structure USB, RS232 (RS422/RS485 optionally) Option: Net Monitors wireless (ZigBee) Option: TCP/IP (Ethernet/WLAN) 6 additional configurable analogous sensor inputs 1 additional counter input (for models without GM-tube option only) Option: relay contacts instead alert light tower 230VAC/50Hz Approx. 500VA Internal NiMH buffer battery 12V/3.8Ah for more than 12 hours operation in case of mains power interruption (without pump) Self-coiling power cord Ergonomic and smart design Ease of decontamination 1110mm x 520mm x 490mm 54kg 8 tyres for good portability 0 50 C 5 95%rH, noncondensing

Software dvision Additional options Calibration/Test Remote control Data transfer, visualization Data management, export to text files System configuration Creating/Editing of measurement cycles Network management Separate filter unit (connection by hose and cable) Wall mounted housing Sodium Iodide gamma probe (2 x 2 ) with spectroscopy and nuclide identification GM tube for dose rate measurement CO and Methane sensors for usage in underground mines GPS receiver Factory calibration in a Radon daughter product atmosphere with aerosol generator Test sources Am-241 (Alpha) and Cs-137 (Beta); recommended are area sources with 25mm or 36mm diameter and 185Bq nominal activity such as Eckert & Ziegler AMR02011/CDR02011 or AMR03011/CDR03011 or similar Flow rate check on top of the filter using adapter dome and low differential pressure air flow meter ( p < 15mbar @35l/min) Aer 5300 The Aer5300 offers a separated (instead of the fixed one) detector/filter unit. The unit is connected by a flexible tube and a cable to the body of the instrument. Thus, the sample can be taken at the preferred place (where contamination is most likely) even in case of limited space. Dimensions Foot print (width x length): 308mm x 180mm Height: 175mm plus height of detector head Connections Flexible tube with quick lock connector (max. 6m) Cable (connectors at both sides; max. 6m) Positioning The detector/filter unit must be operated only in right up position (detector up) The unit is fixed on top of the instrument body during transportation

Detection Limits The detection limits stated in the tables below are valid for following operational conditions: Flow rate = 35l/min k 1-α =3 (99.8%) k 1-β = 1.65 (95%) 1DAC(Pu) = 0.2Bq/m³ (10CRF835) 1DAC(Sr90) = 200Bq/m³ (10CRF835) Additionally for Beta measurement: F = 0.6 Gamma background = 0.1µSv/h The assumption for the detection limit of the concentration is a momentarily step-like increase of air activity concentration up to the detection limit at the beginning of a sampling interval. Furthermore it is presumed that there was no LLRD activity deposited on the filter. Po-218 *) T = 1min Alpha LLRD T = 5min T = 15min Bq/m³ Bqh/m³ DACh Bq/m³ Bqh/m³ DACh Bq/m³ Bqh/m³ DACh Bq/m³ 10 0.92 4.6 55 0.38 1.9 4,6 0.22 1.1 0.9 20 1.25 6.2 75 0.54 2.7 6,5 0.33 1.6 1.3 50 1.92 9.6 115 0.88 4.4 10,6 0.58 2.9 2.3 100 2.70 13.5 168 1.33 6.7 16,0 0.95 4.7 3.8 Po-218 *) T = 1min Beta LLRD T = 5min T = 15min Bq/m³ Bqh/m³ DACh Bq/m³ Bqh/m³ DACh Bq/m³ Bqh/m³ DACh Bq/m³ 10 2.75 0.014 165 1.21 0.006 14.5 0.69 0.004 2.8 20 3.74 0.019 224 1.65 0.008 19.8 0.95 0.005 3.8 50 5.76 0.029 345 2.55 0.013 30.7 1.47 0.007 5.9 100 8.06 0.040 483 3.58 0.018 43.0 2.06 0.010 8.3 *) The activity concentration of Po-218 is always less than the one of Rn-222

Possible modifications of Air Monitor Aer5X00-XXXX Aer 5X00-XXXX D with dual spectrometer special modification for Thorium (Th227) therapy *) S with vacuum adapter for stack monitoring F fixed filter holder for single filter, diam. 47mm G double detector for dynamic gamma background compensation 2 trolley-mounted standard version 3 trolley-mounted version with removable filter/detector unit 4 wall-mounted version with fixed installed filter /detector unit 5 wall-mounted version with removable filter/detector unit *) options D and G cannot be combined