Portable Alpha/Beta Continuous Online Air Monitor (CAM)

Similar documents
Aer 5200/5300. Data Sheet Aer 5200/5300. Portable Alpha/Beta Continuous Online Air Monitor (CAM) Closer to your application

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

RTM / & 01/ / RTM

Environmental, Pollution & Security Monitoring. Radiation Protection & Nuclear Security. Radon, Thoron, Daughter Products & Radioactive Aerosols

ß-Aerosolmonitor FHT 59 C

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

stationary dose rate measuring systems

Thermo Scientific Aerosol Monitor FHT 58 S Technical Specification ZT-221E

icam -HD High Flow Rate Alpha/Beta Air Monitor Radiation Safety. Amplified. DESCRIPTION KEY FEATURES BENEFITS OPTIONS

Radiation Monitoring System RMS

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

Scientific Production Company Doza. Radiation monitoring equipment

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

Portable Survey Instruments NISP-RP-01

Kata products Kata DGM-1500 Turva

Radiation Monitoring Systems

Nuclear Associates

Quality and Technology - Made in Germany -

Identify the following features and specifications for the ESP1

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

A Continuous Air Monitoring Sampler for 125 I - RIS-125

Using the GammaRAE II Personal Radiation Detector

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science

Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One. Firmware Version 3.00 D August 2006

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Development of high sensitivity radon detectors

COMPACT RADIOACTIVE AEROSOL MONITORING DEVICE FOR EARLY WARNING NETWORKS

Detecting Radiation. Protection through Detection. February Animations in this training work best in Windows XP

SEAWATER RADIATION DETECTION SYSTEM WATER PROTECTION

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter

Measurement Devices. Topic 5 - Audio 56

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S)

Introduction...1 Specifications... 1 Limitations... 1

Dosimeters/Survey meters

Radiation Monitoring Equipment

RIID capability in the palm of your hand

Portable Instruments For First Response & In-Situ Analysis of Radiation

Fundamentals is subdivided into Sources of Radiation, Biological Effects, Mathematics, Chemistry, Physics, and Units and Terminology.

ISO 3999 INTERNATIONAL STANDARD. Radiation protection Apparatus for industrial gamma radiography Specifications for performance, design and tests

PORTABLE or FIXED PERSONNEL & VEHICLE MONITOR

North American Technical Services

SVG 2 and Probes. Innovation with Integrity. The new Generation of Semiconductor Radiation Meters and Handheld Radiation Detection Probes

AERIAL RADIATION & CHEMICAL DETECTION SYSTEM. DroneSENSOR TM Series. Particulate Alpha, Beta, Gamma & Airborne Chemicals

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Application Note. Application Note for BAYEX

Contamination Meter Users Manual

RadEye N / NL Personal Highly Sensitive Neutron Radiation Detector

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

Product data sheet Palas Fidas 200 S

Measurement system for detection of Radon in building

Dräger X-am 7000 Multi-Gas Detection

Radiation Alert Frisker INTERNATIONAL

Environmental radioactivity surveillance system of ANPA

POSITRON EMISSION TOMOGRAPHY (PET) CENTER MONITORS

Pico Envirotec Inc., CA & ENVINET a.s., CZ NEW APPROACH TO GLOBAL MONITORING OF THE RADIOLOGICAL SITUATION; INDUSTRIAL, ENVIRONMENTAL & EMERGENCY

HSD Dry Cabinet. Outstanding performance

portable gas analyser

AERIAL RADIATION DETECTORS

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

Our Extended Personal Electronic Dosimeter (PED) Family

RadEye B20 RadEye B20-ER Multi-Purpose Survey Meter

Drying and heating chambers

THE NEW GENERATION VACUUM PUMP SYSTEM SC

Laboratory Impex Systems Ltd

User s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31

Danfoss gas detection units

Alpha Spectroscopy. Vacuum Light. Important things to know before you load your samples:

P U B L I C N O T I C E

Canberra icam: the worldwide alpha/beta air monitoring solution. James Forde-Johnston EMS Product Manager Japan User Group Meeting

FUNCTIONAL SAFETY MANUAL

Your competent partner for measuring and services.

HSD Dry Cabinet

Turnkey Solutions for Radiation Protection in PET Laboratories R A D I A T I O N P R O T E C T I O N

Comprehensive applications of the gas flow proportional counters for Radiological Surveillance

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

Dynamic Radon Detection Over Measurement

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor

Instruments and Consumables

requirements. Serial: USB or RSXXX Bluetooth GPS/GSM Ethernet Standard or rugged desktop or laptop PC or tablet; Android smartphone or tablet

Radiation Alert Area Monitor

ALTAIR 5X Multigas Detector Product Specification

Via Umberto Giordano, Padova Tel Fax VERSIONS ACCURACY

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

portable gas analyser

MSD Cabinets. Modular Dry Cabinet. Outstanding performance

ORTEC. Detective-Remote. Multiple Instrument Remote Monitoring and Control Software. The right software, the right solution, the right answer!

HSD Dry Cabinet. Outstanding performance

Ranger EXP RADIATION A L E R T

22 Radiological and Environmental Monitoring Systems Functions, Basic Configuration, and Interfaces

LAUNDRY MONITORING SYSTEM Model # LIM-64S

FLX380-30x FlexTester OTDR

Laboratory Refrigerator/Deep Freezer TC 802

TRITIUM IN WATER MONITOR REAL TIME CONTINUOUS Model # LIQ-X-(H3)

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Transcription:

Aer 5000 Desktop Portable Alpha/Beta Continuous Online Air Monitor (CAM) The Aer5200 monitors the ambient air continuously to detect airborne radioactive aerosols (LLRD). Typical application fields are nuclear facilities, the NORM industry, mines and nuclear medicine (e.g. DIN ISO 16639 / VDE 0493-1-6639). The unit is very suitable for limited space conditions due to its compact design. The aerosols will be deposited on the surface of a filter by the internal pump and will be analysed by spectroscopy. The natural background due to Radon and Gamma irradiation will be fully compensated. The Aer5000 Desktop is instantly ready for operation after powering. The intuitive touch screen operation and the straight forward menu structure allow the operation even by unskilled staff. The ergonomic design, big wheels and low weight makes it easy to relocate the instrument if required. The stylish unit with plain surfaces can be easily decontaminated. The pump works very quiet. The open face air inflow in combination with a regulated flow rate ensures a uniform and low-loss deposition of the aerosols on the filter surface. The large active filter diameter and the long filter tape used in the filter stepping unit results in outstanding operation periods without intervention. The unique mechanism for dynamic filter sealing avoids leakages as present in conventional movable-filter solutions. Optionally, the unit may be equipped with a vacuum adapter (KF/DN16) to connect sampling pipes or flexible tubes. Particle losses at the inlet become negligible by the special construction. Because of the high sensitivity of the Aer5000 Desktop, very low detection limits and alert thresholds for Alpha and Beta exposure can be achieved. All parameter, necessary for proper operation are monitored continuously and are part of the stored measurement data. A flexible alert system warns the user in case of the exceedance of a threshold or any deviation from the normal operation mode. The signal tower can be removed from the housing for optimal visibility. There are many options for additional detectors/sensors (e.g. NaI probe with nuclide identification) and system integration.

Aer 5200 Technical Data Detector Filter/Stepper Pump Results 900mm² ion-implanted silicon detector Option: Double detector for dynamic Gamma background compensation Energy range 80keV...3MeV (Beta); 3 10MeV (Alpha) Counting efficiency (4 ) approx. 20% Open face sampling for minimum collection losses Option: Tube connector for air inlet (vacuum flange KF/DN16) Membrane filter tape (PTFE); 5µm pore size; length 30m; width 65mm; good for more than 300 filter steps Pneumatic filter sealing for minimum leakage rate Deposition rate >99,9% Active filter test with respect to perforation and exhaustion Tool-less replacement of filter coils More than 12 month autonomous operation in normal environment Configurable trigger for filter stepping (e.g. each sample interval, fixed period, filter exhaustion, activity detected) Required period for filter replacement <2s Brush-less, long-life, low noise quality membrane pump Nominal air flow 8l/min (adjustable range 4 to 10l/min) Processor controlled air flow for constant deposition conditions Pressure drop across the filter 15 150mbar (at 10l/min) Noise emission approx. 51dBA (in 1m distance) Equilibrium Equivalent Concentration (EEC) for Radon and Thoron daughter products in Bq/m³ Exposure for Alpha and Beta emitters (LLRD) in Bqh/m³ Dose for Alpha and Beta emitters in µsv or DAC-hrs (dose coefficients adjustable by user) Detection of Natural Uranium with automatic selection of the U nat dose coefficient Average activity concentration for Alpha and Beta emitters in Bq/m³ Separate channel for Alpha gross counting in cps or Bq Option: dose rate in µsv/h Temperature, humidity, pressure, battery voltage Flow rate, filter exhaustion, filter stepping, end of filter tape

Standards IEC 60761-1 IEC 60761-2 IEC 61578 IEC 61577-3 IEC 1263 CE, VDE DIN ISO 16639 (VDE 0493-1-6639) Compensation LLRD Sensitivity Measurement range Measurement s Alert indication Data storage Handling Compensation of natural Radon background by Alpha spectroscopy with dynamic fitting of peak shape with respect to progressive filter exhaustion Upper Alpha energy threshold for LLRD = 5,6MeV Static compensation of Gamma background Option: dynamic compensation of Gamma background by double detector Dynamic shock rejection (mechanical shock) by pulse signal shape analysis approx. 7cpm/(Bqh/m³) 35000Bqh/m³ (175000DACh(Pu)) 2MBq/m³ over 1 minute Up to 16 user definable sampling cycles (1s to 1year) Predefined sampling cycles 1, 5, 15, 60 minutes See tables below Configurable alert thresholds for all measured results Alert tower with green, yellow and red light, 360 visible 90dB signal buzzer (option) Alert indication at display Alert reset is configurable (either with confirmation by the user or automatic reset if the alert condition is no longer present) Pre-defined alerts for LLRD activity, low/high count rate, filter perforation, end of filter tape 2GB SD card (> 1,200,000 data records) Storage of all measured raw data incl. spectra Touch screen 6cm x 9cm (4.5 ); Graphic 240 x128 High contrast even in direct sunlight Backlight Intuitive, straight forward menu structure

Interface Power supply Housing Ambient conditions Software dvision Additional options Calibration/Test USB, RS232 (RS422/RS485 optionally) Option: Net Monitors wireless (ZigBee) Option: TCP/IP (Ethernet/WLAN) 6 additional configurable analogous sensor inputs 1 additional counter input (for models without GM-tube option only) Option: relay contacts instead alert light tower Power adapter 18V/60VA Internal NiMH buffer battery 12V/1Ah for more than 6 hours operation in case of mains power interruption (without pump) Space saving desktop housing Ease of decontamination 308mm x 308mm x 175mm (12 x 12 x 7 ) plus detection head 8kg 0 50 C 5 95%rH, noncondensing Remote control Data transfer, visualization Data management, export to text files System configuration Creating/Editing of measurement cycles Network management Separate filter unit (connection by hose and cable) Sealed filter unit for connection to ventilation ducts Wall mounted housing Sodium Iodide gamma probe (2 x 2 ) with spectroscopy and nuclide identification GM tube for dose rate measurement CO and Methane sensors for usage in underground mines GPS receiver Factory calibration in a Radon daughter product atmosphere with aerosol generator Test sources Am-241 (Alpha) and Cs-137 (Beta); recommended are area sources with 25mm or 36mm diameter and 185Bq nominal activity such as Eckert & Ziegler AMR02011/CDR02011 or AMR03011/CDR03011 or similar Flow rate check on top of the filter using adapter dome and low differential pressure air flow meter ( p < 15mbar @10/min)

Detection Limits The detection limits stated in the tables below are valid for following operational conditions: Flow rate = 8l/min k 1- =3 (99.8%) k 1- = 1.65 (95%) 1DAC(Pu) = 0.2Bq/m³ (10CRF835) 1DAC(Sr90) = 200Bq/m³ (10CRF835) Additionally for Beta measurement: F = 0.6 Gamma background = 0.1µSv/h The assumption for the detection limit of the concentration is a momentarily step-like increase of air activity concentration up to the detection limit at the beginning of a sampling interval. Furthermore it is presumed that there was no LLRD activity deposited on the filter. Po-218 *) T = 1min Alpha LLRD T = 5min T = 15min Bq/m³ Bqh/m³ DACh Bq/m³ Bqh/m³ DACh Bq/m³ Bqh/m³ DACh Bq/m³ 10 2.7 13.3 160 0.74 3.7 8.8 0.4 2.0 1.6 20 2.7 13.3 160 1.0 5.0 12.0 0.57 2.8 2.3 50 3.7 18.3 220 1.54 7.7 18.5 0.95 3.7 3.7 100 5.0 24.9 285 2.21 11.1 26.6 1.41 5.7 5.6 Po-218 *) T = 1min Beta LLRD T = 5min T = 15min Bq/m³ Bqh/m³ DACh Bq/m³ Bqh/m³ DACh Bq/m³ Bqh/m³ DACh Bq/m³ 10 5.12 0.026 307 2.21 0.011 14.5 1.26 0.006 5.0 20 6.79 0.034 407 2.96 0.015 19.8 1.69 0.009 6.8 50 10.2 0.051 615 4.51 0.023 30.7 2.59 0.013 10.4 100 14.2 0.071 853 6.28 0.032 43.0 3.61 0.018 14.5 *) The activity concentration of Po-218 is always less than the one of Rn-222