FSB Series II Gas-Fired Hot Water Induced Draft Boilers

Similar documents
15B Cast Iron Gas Fired Boilers For Forced Hot Water

DXL SERIES II CAST IRON GAS FIRED BOILERS FOR FORCED HOT WATER

Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES

Cast Iron Gas Boiler For Forced Hot Water REPAIR PARTS AND OPTIONAL ACCESSORIES

Models TRB4075 TRB4095 TRB4110 TRB5100 TRB5115 TRB5135 TRB6130 TRB6145 TRB6165 TRB7165 TRB7180 TRB7190

GMOS Series OIL-FIRED CAST IRON STEAM BOILER PARTS AND OPTIONAL ACCESSORIES

Model SSV-399 GAS BOILER PARTS, KITS & OPTIONAL ACCESSORIES

EXCELSIOR. High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS

STARFIRE IV WATER OIL FIRED CAST IRON BOILER

Models EXB4075 EXB4095 EXB4110 EXB5100 EXB5115 EXB5135 EXB6130 EXB6145 EXB6165 EXB7165 EXB7180 EXB7190

OIL-FIRED CAST IRON HOT WATER BOILER. Parts and Optional Accessories

EMPIRE II SERIES II Models 3EW.65 3EW.75 3EW1.00 4EW.90 4EW1.25 4EW1.50 5EW1.20 5EW1.75

HOT WATER BOILER ( MBH)

Power Direct Vent PDV(S&T) Models

High Efficiency Oil Fired Hot Water Boiler REPAIR PARTS & OPTIONAL KITS. P/N# , Rev. C [01/09]

USER'S INFORMATION MANUAL

Ultra Boiler Series 1 & 2 Jacket Parts

USER'S INFORMATION MANUAL

12a. Replacement parts. GOLD CGs Gas-Fired Water Boiler Boiler Manual. Section assembly Base Jacket Trim Controls...

URGPV & ULGPV ECO MODELS

MASTERTEMP HEATER REPLACEMENT PARTS

USER'S INFORMATION MANUAL

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

Quantity X Section Assembly (Intermittent and Continuous Circulation Only)

Energy Saver Commercial Gas Millivolt (DM) Models

USER'S INFORMATION MANUAL

Figure 10 or Figure 6

FOR FORCED HOT WATER MODEL NUMBERS: 15045, 15070, 15096, 15120, 15145, 15175, 15195, 15245, 15295

USER'S INFORMATION MANUAL

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

Replacement parts EG/PEG

PUREFIRE PF-50, PF-80, PF-110 & PF-140 PF-50, PF-80, PF-110 & PF-140

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

GV Series 4 Section Assembly

13.2 Component Illustrations, Parts Lists, and Part Numbers

JE Series Cast Iron Commercial Natural Gas Steam Boiler Submittal/Specifications

AT SERIES C ELECTRIC BOILERS ABSOLUTE EFFICIENCY. TOTAL COMFORT! Save Money, Save Space, Save the Environment! RESIDENTIAL / LIGHT COMMERCIAL

USER'S INFORMATION MANUAL

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

WF WAVE SERIES: WF 42 AND WF 60 PIZZA OVENS REPLACEMENT PARTS LIST

/13 Price - $5.00

G and SL Series with NRG System

Effective february 9, 2015

Effective october 14, 2014

GM9T SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%

Commercial Water Heater Replacement Parts. Price List. For Models: SBS, SBD, SBN, SDV, SUF, PCE and CSB. Prices Effective

RAYPAK ILLUSTRATED PARTS LIST

Platinum Series Ranges

PT9 SERIES DOWNFLOW/HORIZONTAL 2-STAGE NATURAL GAS FURNACE (90%) (STYLE A)

G, SL & B-Series Old Honeycutt Road, Fuquay-Varina, NC

OR Replacement Instructions Heat Exchanger Assembly, ASME

PENTAIR/PUREX TROPIC ISLE HEATER

Technical Bulletin MODELS AFFECTED SW3, SW3T SW4, SW4T SW5, SW5T

GM9V SERIES - UPFLOW 2-STAGE VARIABLE SPEED NATURAL GAS FURNACE - 90% (STYLE A)

MP GS/GD 10 GAS. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

PUREFIRE PF-850 & PF PF-850 & PF-1000 Heat Exchanger

15B SERIES Cast Iron Gas Fired Boilers For Forced Hot Water

15B SERIES Cast Iron Gas Fired Boilers For Forced Hot Water

CG Section and Base Assembly Series 1 through 12

GM9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE J)

RAYPAK ILLUSTRATED PARTS LIST

Installation. Part Number /0209

FC9V SERIES 2-STAGE CONDENSING VARIABLE SPEED UPFLOW NATURAL GAS FURNACES (STYLE C)

GF9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE G)

GUH & GDD SERIES REPLACEMENT PARTS LIST SINGLE STAGE CONDENSING & NON-CONDENSING FURNACES 80+ AFUE 92.1% AFUE 95.0 % AFUE. GUH92A Upflow / Horizontal

FC9V SERIES - UPFLOW 2-STAGE CONDENSING VARIABLE SPEED NATURAL GAS FURNACES (STYLE A)

GM9S SERIES CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE K)

All repair parts orders - no minimum charges. Please order with code number. All prices quoted are in U.S. dollars. All prices subject to change

LGB Gas fired boiler

GM9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen (Style D) and 2nd Gen, STYLE B)

FL9M SERIES MODULATING CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE A)

PS9 SERIES (STYLE C) UPFLOW NATURAL GAS FURNACES - 90%

PUREFIRE PF-50, PF-80, PF-110 & PF-140 PF-50, PF-80, PF-110 & PF-140

Service Parts Catalog

PC9 SERIES MODULATING VARIABLE SPEED CONDENSING DOWNFLOW/HORIZONTAL NATURAL GAS FURNACES - (STYLE A)

Columbia Boiler Company

ODVB SERIES Gas Fired Boilers For Forced Hot Water INSTALLATION, OPERATION & MAINTANANCE MANUAL

Replacement Parts List For Models COS-20G

FC9V SERIES 2-STAGE VARIABLE SPEED UPFLOW CONDENSING NATURAL GAS FURNACES (1st Gen, Style D and 2nd Gen, Style B)

PS9 SERIES (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%

Repair Parts List DRYER MODEL NUMBER MDG30MNAWW. When requesting service or ordering parts, always provide the following information:

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

Repair Parts List DRYER MODEL NUMBER MDG30PN3AW. When requesting service or ordering parts, always provide the following information:

Exploded Parts Manual

DFG-100 XCEL SERIES GAS CONVECTION OVEN REPLACEMENT PARTS LIST

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model EGIS - AS. R EN - Edition 03-01/03/2008

MAGB SERIES Gas Fired Modu-Pac Multiple Commercial Boiler System INSTALLATION, OPERATION & MAINTANANCE MANUAL

TING INSTRUCTIONS AND OPERATING INSTR AL AND OPERA ALLATION MANUAL INSTALLA GAS FIRED BOILERS FOR FORCED HOT WATER

PS9 SERIES - UPFLOW 1-STAGE NATURAL GAS FURNACE - 90%

DFG-100 XCEL SERIES GAS CONVECTION OVEN REPLACEMENT PARTS LIST

VICTORY VSPH VICTORYVSPH THE PERFECT CHOICE FOR. Cast-iron sealed combustion, direct vent gas boiler

COOKTOP, BURNER AND GRATE PARTS For Model: JDRP430WP00 (Stainless)

Sunpak Infrared Heater. Model S34 TSR

PT9 SERIES - UPFLOW 2-STAGE NATURAL GAS FURNACE - 90% (STYLE A)

C-Spa XI Models

CYCLONE XHE - MODEL BTH-300A/400A See Page 2

Is a heating protection plan really worth it? Decide for yourself!

PrecisionTemp Shower-Mate

BCX-14 & BX-14 COMBINATION OVEN STEAMER CNVX-14 CONVECTION OVEN REPLACEMENT PARTS LIST

bc14g combi oven serial numbers with iw/ix/iz/jg/jo

Transcription:

FSB Series II Gas-Fired Hot Water Induced Draft Boilers Models FSB- FSB-3 FSB-4 FSB-5 FSB-6 FSB-7 REPAIR PARTS AND OPTIONAL KITS Ordering Instructions Order Parts through your nearest supplier. When ordering parts, obtain Model Number and Serial number from data plate on your boiler. Include following information when ordering. Part Number Part Description Boiler Model Number Boiler Serial Number 0 Dwyer Avenue, Utica, NY 350 Tel. 800 53 7900 www.ecrinternational.com All specifications subject to change without notice. 08 ECR International, Inc. PN 40009444 REV. C [06/5/08] BDR THERMEA GROUP

Jacket Sections and Base Parts REPAIR PARTS LIST 3 0 9 8 7 6 5 4 3 PN 40009444 REV. C [06/5/08]

Jacket Sections and Base Parts JACKET AND BASE KEY NO. DESCRIPTION PART NUMBERS FOR Section 3 Section 4 Section 5 Section 6 Section 7 Section Jacket, Top Panel 730000 7300003 7300004 7300005 7300006 7300007 Jacket, Back Panel 730000 7300003 7300004 7300005 7300006 7300007 3 Blower Cover Plate 6300070 6300070 6300070 6300070 6300070 6300070 4 Jacket, Right Side Panel 09008498 09008498 09008498 09008498 09008498 09008498 5 Rating Plate - - - - - - 6 Boiler Base 4500733 4500734 4500735 4500736 4500737 4500738 7 Jacket Tie Bar 4500653 4500654 4500655 4500656 4500657 4500658 8 Insulation, Base Side ( Required) 46400 46400 46400 46400 46400 46400 Insulation, Base Front 464 4643 4644 4645 4646 4647 Insulation, Base Rear 464 4643 4644 4645 4646 4647 9 Service Door 09008686 09008687 09008688 09008689 09008690 0900869 0 Control Standoff (See page 8) 09008496 09008496 09008496 09008496 09008496 09008496 J-Box Cover (See page 8) 09008506 09008506 09008506 09008506 09008506 09008506 Jacket, Left Side Panel 09008497 09008497 09008497 09008497 09008497 09008497 3 Control Panel 09008500 0900850 0900850 09008503 09008504 09008505 Cleanout Plate(s) & Insulation 450539 450540 45054 45054 450540 & 45054 45054 (x) Flue Collector 73000300 730003003 730003004 730003005 730003006 730003007 Jacket, Complete FSB 55000435 55000436 55000437 55000438 55000439 55000440 #0 x / Sheet Metal Screw 4695074 4695074 4695074 4695074 4695074 4695074 Block Assembly (7,0,,,3,7)) 4000 40003 40004 40005 40006 40007 Combustible Floor Plate 46403 46403 46403 46403 46403 46403 Not illustrated 3 PN 40009444 REV. C [06/5/08]

BOILER CONTROLS AND PIPING REPAIR PARTS Boiler Controls and Piping Repair Parts NOTE: Circulator is not pre-installed 3 4 5 6 7 9 8 0 4 PN 40009444 REV. C [06/5/08]

BOILER CONTROLS AND PIPING REPAIR PARTS Boiler Controls and Piping Repair Parts Key No. Description Part No. ¾ ASME Relief Valve 460 ¾ x 5½ Female Adapter 3000 3 Temperature Pressure Gauge (3½ Stem) 60006SP 4 Bushing ½ x ¼ 06000 5 Tee ¼ x ¼ x ¾ PF0590 6 Bushing ¼ x ½ " 4693008 7 Well 63500 8 ¼ x ¾" x 3/4" Tee 5000 9 Female adapter ¼ x 5½ " 460709 0 Induced Draft Blower and Gasket 400090 Pressure Switch -,3,4,5 Section 4655006 Pressure Switch - 6,7 Section 4655005 ¼ Bent Tube 4607004 Sensor 4000773 Clip 4000803 Rubber Tube (Blower to Pressure Switch) 5504 Rollout Switch 46900 3 x 4 Increaser Fitting - Galvanized 4680 Drain Valve 4000933 Not illustrated 5 PN 40009444 REV. C [06/5/08]

NATURAL GAS VALVE Natural Gas Valve FOR USE WITH NATURAL GAS ONLY NOTE: Actual gas valve may look different than gas valve shown. KEY NO. 3 DESCRIPTION Gas Valve, Natural Gas Pilot Tube With Fitting 0-3 x 3/6 Slotted Hex Head Screws NATURAL GAS BURNER & MANIFOLD PARTS PART NUMBERS FOR Section 3 Section 4 Section 5 Section 6 Section 7 Section 46605 46605 46605 46605 466058 466058 433000 433000 433000 433000 4330000 4330000 469530 469530 469530 469530 469530 469530 4 Gas Manifold 46604 466043 466044 466045 46604 46605 5 6 6A 7 *Orifice -Natural Gas **Main Burner Less Pilot Bracket Main Burner with Pilot Bracket Pilot with Orifice, Natural Gas 465030 46503 46503 46503 465035 465035 - - - 46553 46553 46553 46553 46553 46553 46553 46553 46553 46553 46553 4000903 4000903 4000903 4000903 4000903 4000903 Rollout Shield 450093 4500933 4500934 4500935 4500936 4500937 *Requires less than the number of sections. **Requires less than the number of sections. Not illustrated. Quantity is unless otherwise noted. 6 PN 40009444 REV. C [06/5/08]

PROPANE GAS VALVE Propane Gas Valve For Use With Propane Gas Only NOTE: Actual gas valve may look different than gas valve shown. KEY NO. 3 DESCRIPTION Gas Valve, Propane Gas Pilot Tube With Fitting 0-3 x 3/6 Slotted Hex Head Screws PROPANE GAS BURNER & MANIFOLD PARTS PART NUMBERS FOR Section 3 Section 4 Section 5 Section 6 Section 7 Section 55000740 55000740 55000740 55000740 5500059 5500059 433000 433000 433000 433000 4330000 4330000 469530 469530 469530 469530 469530 469530 4 Gas Manifold 46604 466043 466044 466045 46604 46605 5 *Orifice-Propane Gas 465039 465064 465064 465064 465036 465036 6 6A 7 **Main Burner Less Pilot Bracket Main Burner with Pilot Bracket Pilot with Orifice, Nat Gas _ 46553 46553 46553 46553 46553 46553 46553 46553 46553 46553 46553 4000903 4000903 4000903 4000903 4000903 4000903 Orifice Propane Gas PB0008 PB0008 PB0008 PB0008 PB0008 PB0008 Rollout Shield 450093 4500933 4500934 4500935 4500936 4500937 *Requires less than number of sections. **Requires less than number of sections. Not illustrated. Quantity is unless otherwise noted. Not illustrated pilot sold only in natural gas, must field convert. 7 PN 40009444 REV. C [06/5/08]

CONTROL MODULE CONTROL ASSEMBLY 3 4 7 6 5 ITEM DESCRIPTION P/N QTY. J-BOX 09008499 J-Box Cover 09008506 3 Control 400094 4 Grommet 0600005 5 Ground Screw #8 HW0770 6 Control Standoff 09008496 7 Transformer 4000878 * Line Voltage Harness 4000994 * Low Voltage Wire Harness 4000934 * Circulator Harness 40008767 * Pilot (with wires) [Shown on page 6] 4000903 * NOT SHOWN PN 40009444 REV. C [06/5/08]