Compressed Air Dryer

Similar documents
PROTEK DRYER CONTROLS

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Installation & Operation Manual Ice Cream Freezers

RATIO:GUARD Model E-1S EC Monitor

USER S OPERATING AND INSTRUCTION MANUAL

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Ice Cream Freezers

Steam Distribution. Installation Manual. Includes installation instructions for steam distributions ASD/BSD/CSD/RSD/SSD.

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

Installation and Operations Manual

Desiccant Tank Retrofit Kit for CD100/CS101 dehumidifying dryers

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

HB CDA SERIES WITH TEMPERATURE SETBACK

RPI Industries, Inc.

STEAM DISTRIBUTORS ASD / BSD / CSD. Installation Manual C

SPI Communications Option

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Deluxe Discharge Alarm

Propane Fume Detection System With Solenoid Valve Control

Air Pump Up to 800 gallons

Service Parts, Kits and Accessories

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

V LPM Desiccant Air Dryer Installation and Operation Manual

SACKSAFOAM QUICK FILL OPERATIONS MANUAL 2019A

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

Propane Fume Detection System With Solenoid Valve Control

Propane Fume Detection System

NOVALYNX CORPORATION MODEL A EVAPORATION PAN AUTOMATIC REFILL SYSTEM INSTRUCTION MANUAL

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

Desiccant / Pump Dehumidification System. Model Operating Manual

INSTALLATION AND OPERATING MANUAL

InstructIon Manual KrEs EQuIPMEnt stands

PROOF BOX (All SD,DD, and TD 99 Models)

Model TWBS.EW.H Tempered Water Blending System

VACUUM LOADERS GSL Series

Blade Series Heat Exchanger Operation and Installation

Model OP155 Air Dryer

Dust Collector. Sizes DC1 and DC2 U S E R G U I D E UGC

OPERATION, SERVICE & PARTS MANUAL

Professional Warming Drawer and Warming Drawer Cabinet

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50

R A D I A N T O U T D O O R H E A T E R S OPERATION, INSTALLATION AND MAINTENANCE MANUAL. TT-MTM Wall Controller

C&M REAR FEED Long-stroke Vertical Down-stroke Baler for Baling Multi-Materials

Panel Mounted Heat Exchangers by Dantherm, Inc.

1/24/01 SYLVANIA Process Heat FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

A PROUD HERITAGE OF EXPERIENCE & QUALITY. Beverage Cooler VT-SC-1

RPI Industries, Inc.

Model 20201/20201-A/20201-B Wind Sensor Heater. User's Manual. All Weather Inc National Drive Sacramento, CA USA

Frosty Factory of America, Inc.

USE AND CARE GUIDE FOR MODEL MEK1, MEK15. Express Cordless Kettle

DUST FREE CARBON Whole House Air Purifier

CLIMAGUARD Air-to-Air Outdoor Heat Exchangers INSTRUCTION MANUAL. Rev. H 2015 Pentair Equipment Protection P/N

Cat 5 Pro Vacuum OPERATOR S MANUAL

OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions

20 High Velocity Fan with 135 Tilt Head

RPI Industries, Inc.

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

Operating Instructions Manual. Condensate Separators. Models 4GNL3 thru 4GNL9 and 53RG84 thru 53RG95

VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016

Electric Duct Heaters

Instruction Manual for the Globe Mixer. Model SP8-RL

48 MaxxAir Portable Evaporative Cooler Owner s Manual

OWNER/OPERATOR MANUAL COMPONENTS, INSTALLATION, OPERATION AND SERVICE INSTRUCTIONS

Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL

SONANCE GARDEN SERIES SGS SYSTEM INSTRUCTION MANUAL

DRY AIR SYSTEMS, INC Metro Boulevard Maryland Heights, Missouri (314) fax (314)

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT

Armstrong ExpressPack Multi-Tube Steam Dispersion Panel Assembly and Installation Instructions

DECORATIVE GAS LOG PLACEMENT INSTRUCTIONS

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

GASGUARD NH 3 2% Ammonia Sensor OPERATING & INSTALLATION MANUAL

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

MS-600 DESICCANT DEHUMIDIFIER

Instruction Manual. Double Candy Apple Cooker

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

Portable Dehumidifier

Inline Heater for Solvent or Gas. Installation and Operation Manual

CELDEK Evaporative Cooler Module Installation, Operation, and Maintenance Manual. CELDEK Evaporative Cooler

Model 9201EFE Tempered Water Blending System

GETZ MANUFACTURING PART # CYLINDER DRYER

Horizontal Bottle Cooler Installation and Operation Manual

GL-DEH Series Portable Dehumidifier Operating Instructions

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

Portable Dehumidifier with Internal Pump

INSTALLATION, OPERATION AND MAINTENANCE

10810 W. LITTLE YORK RD., STE. 130 HOUSTON TX VOICE (713) FAX (713) web: IMPORTANT!!!

Models Goldfisch Fat Extraction Apparatus


INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

GG-R REFRIGERANT SENSOR. Installation and Operation Manual

OPERATING INSTRUCTIONS

Ledco XL-44 Wide Format Pouch Laminator

Vent Master. OWNER S MANUAL Read these instructions before you install or operate the Orton Vent Master System

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Model 9201EW Tempered Water Blending System

PRODUCT MANUAL. TT-MTM2 Hard-Wired Controller with Remote

Installation Instructions / Warranty. Starck 10111XX XX XX1

NATURAL GAS MODELS: SGC-36N/SGC-48N/SGC-60N/SGC-72N SGR-24N/SGR-36N BARBECUE - CARE AND USE

KNHE48 SERIES WATER-TO-AIR HEAT EXCHANGER

Transcription:

Compressed Air Dryer INSTRUCTION MANUAL IB200602 THORESON-McCOSH INC 1885 Thunderbird St. Troy MI. 48084 Phone 1-248-362-0960 Fax 1-248-362-5270 sales@thoresonmccosh.com parts@thoresonmccosh.com

FORWARD The information contained in this Instruction Manual is provided to you for the maintenance of your Thoreson-McCosh equipment. Also included in this manual are operating instructions, a service parts list, and wiring diagrams. Please file this manual for future use. For additional information, please contact: THORESON-McCOSH Inc. 1885 Thunderbird Street Troy, MI 48084 Phone: (248) 362-0960 Facsimile: (248) 362-5270 sales@thoresonmccosh.com parts@thoresonmccosh.com CUSTOMER RECORDS Upon receipt of your Thoreson-McCosh equipment, it is very important that you complete the table below. The information will be needed to best serve you when you call the Thoreson-McCosh Service Department with questions or to order replacement parts. The information is located on the Serial Tag on the unit and inside the door of the control box. Model Name Serial No. Wiring Diagram No. Insert No. Program No. Layout No. High efficiency resin handling and preparation equipment for the plastics industry

Table of Contents SECTION 1: WARRANTY...2 SECTION 2: INTRODUCTION...3 2.1: QUICK START...3 2.2: POWER CONNECTIONS...3 2.3: UNITS WITH COMPLETE DRYING HOPPER...3 SECTION 3: COMPRESSED AIR DRYER METHOD OF OPERATION...4 SECTION 4: DRYER CONTROLS...5 4.1: TURNING THE DRYER ON...5 4.2: CHANGING THE TEMPERATURE SET POINT...5 4.3: DRYER COMPONENTS...6 SECTION 5: PRELIMINARY TD DRYER CHECKS...7 5.1: VISUALLY CHECKING DRYING SYSTEM...7 5.2: CHECK THE DRYING HOPPER INLET TEMPERATURE...7 5.3: CHECK THE HOPPER TEMPERATURE DISTRIBUTION...7 5.4: CHECK THE DRYER RETURN AIR TEMPERATURE...7 5.5: CHECK THE DISCHARGE DEWPOINT OF THE DRYER...7 SECTION 6: MAINTENANCE...7 6.1: FILTERS...7 6.2: REPLACEMENT PARTS...7 6.3: MAINTENANCE SCHEDULE...8 SECTION 7: ADDITIONAL INFORMATION... WIRING DIAGRAMS... Revision Date 5/6/06 1 IB200602

SECTION 1: THORESON-MCCOSH PRODUCT WARRANTY Thoreson-McCosh warrants each product of its manufacture to be free from defects in material and workmanship for a period of 30 months (2-1\2) year from the date of delivery to the original purchaser. Thoreson-McCosh s obligation under this warranty is limited to repairing or replacing any part returned to the Thoreson-McCosh factory with transportation charges prepaid, and which, on examination by Thoreson-McCosh, shall disclose to Thoreson-McCosh s satisfaction to have been defective. The purchaser must notify Thoreson-McCosh of such defects and promptly deliver the defective part(s) in accordance with Thoreson-McCosh s shipping instructions, delivery prepaid. Parts will be replaced F.O.B. Thoreson-McCosh factory, by Thoreson-McCosh, and will be invoiced to the purchaser with "credit on return of defective part", if the part is returned within fifteen (15) days after shipment of replacement part. Thoreson-McCosh is not liable for installation or cost to install the replacement part or removal of the defective part. Thoreson-McCosh is not responsible for any failure of its product due to improper use, installation, or operation. Thoreson-McCosh shall not assume any expense or liability for repairs made to any Thoreson-McCosh unit or equipment outside Thoreson-McCosh s own factory unless specifically agreed to in writing by Thoreson-McCosh. Equipment and accessories furnished by us, but manufactured by others, are guaranteed to the extent of the original manufacturer s guarantee to Thoreson- McCosh, if that guarantee exceeds one (1) year. It is expressly understood that Thoreson-McCosh is not responsible for damage and/or injury caused to buildings, contents, products, or persons by reason of installation or use of any of our products. Thoreson-McCosh shall not be liable for loss, damage or expenses arising directly or indirectly from, or being consequential or incidental to, the use of its products or from any other cause. The above warranty supersedes, and is in lieu of all other warranties expressed or implied; and no person, agent, representative or dealer is authorized to give any warranties on behalf of Thoreson-McCosh, not to assume for Thoreson- McCosh any other liability in connection with Thoreson-McCosh products. Revision Date 5/6/06 2 IB200602

SECTION 2: INTRODUCTION SECTION 2.1: QUICK START Your Thoreson-McCosh dryer was thoroughly tested prior to shipment and checked to insure that its performance is up to specifications. Upon arrival in your plant, the unit should be carefully inspected for physical damage, which might have occurred in transportation. Should any damage be observed, it should be reported to the carrier at the earliest possible time. 1. Uncrate equipment. 2. Clean drying hopper. All hoppers are shipped with a light coat of oil. 3. Connect power. 115/1/60. 15 amp service 4. Connect compressed air to the units requiring compressed air. 3 P.S.I. minimum, 15 P.S.I. maximum. 5. Connect Air hoses. The smaller diameter red process hose connects from the dryer to the diffuser on the hopper. 6. Visually inspect drying system. 7. Fill hopper with material. 8. Begin drying, giving first batch of material sufficient residence time before beginning to use material (typically 3 to 4 hours). Check with resin manufacturer. SECTION 2.2: POWER CONNECTIONS The unit is supplied with a standard 115/1/60 power cord rated for at least 15 amps. This unit must have a properly connected ground. SECTION 2.3: UNITS WITH COMPLETE DRYING HOPPER Clean the inside of your hopper thoroughly to avoid contamination of plastic resin to be processed. Install the hopper cone mounting plate to the feed throat of your molding machine, being sure that it is well secured. Revision Date 5/6/06 3 IB200602

SECTION 3: COMPRESSED AIR DRYER METHOD OF OPERATION Revision Date 5/6/06 4 IB200602

SECTION 4: DRYER CONTROLS FIGURE 4.1: DRYER CONTROLS SECTION 4.1: TURNING THE DRYER ON To turn the dryer on, turn the Unit Off/On switch to the On position. SECTION 4.2: CHANGING THE TEMPERATURE SET POINT The dryer comes standard with a digital temperature control. The control displays the actual Process temperature and the Process temperature set point. To increase or decrease the temperature, push the up or down indicators on the face of the control, until it displays the desired temperature set point. The Process temperature set point can be selected from 0 to 400 F. The unit is shipped with normal factory defaults. To deviate from the normal settings, refer to the Temperature Control literature included in the Dryer Instruction Manual. We recommend that the normal factory settings be used. Failure to use these settings, can result in damage to the unit. Consult the service department before making changes. Revision Date 5/6/06 5 IB200602

SECTION 4.3: DRYER COMPONENTS FIGURE 4.2 DRYER COMPONENTS 1) Membrane\Filter MSD-03-CA2D 2) Regulator IR27231-300 3/8 3) 1PS pressure switch 4) 1SOL 3/8 solenoid 5) 1H 1.4 kw Heater 6) 1SSR solid state relay, 25amp 7) 1CB circuit breaker Revision Date 5/6/06 6 IB200602

SECTION 5 PRELIMINARY TD DRYER CHECKS SECTION 5.1: VISUALLY CHECK DRYING SYSTEM Check dryer hoses and hopper. Be sure that delivery hose is in good condition. The Hopper lid should be in place and well sealed.. SECTION 5.2: CHECK DRYING HOPPER INLET TEMPERATURE At the hopper air inlet, the drying temperature should match the recommended temperature specified by the material supplier. In general, as hot as possible without allowing thermal degradation or discoloration of the material being processed If the hopper inlet temperature is lower than the dryer discharge, the dryer temperature setpoint should be increased to compensate for the temperature drop in the process air flow hose. SECTION 5.3: CHECK THE HOPPER TEMPERATURE DISTRIBUTION Let dryer run for 3-4 hours. Air/material temperature in the hopper should be uniform around the hopper at any level, and hot (within 15 F/ 9 C of inlet temperature) up to 80% of the full hopper height when material is being added at the designed drying rate. Under static drying conditions (no new material added to hopper) the discharge temperature should approach inlet temperature after approximately 4-5 hours of operation. Should these checks show that the heat is not progressing upward through the hopper, the dryer should be checked for low airflow. SECTION 6 MAINTENANCE SECTION 6.1 FILTERS The filter should be checked weekly and cleaned with compressed air or replaced if necessary. It is important to remember to check the filter gasket and fix or replace as needed. SECTION 6.2 REPLACEMENT PARTS 1) Compressed air Filter 414958 Revision Date 5/6/06 7 IB200602

SECTION 6.3 MAINTENANCE SCHEDULE TO BE USED IN CONJUNCTION WITH DRYER INSTRUCTION MANUAL DRYER#: DATE: SPECIAL INSTRUCTIONS: WEEKLY CHECK AND CLEAN OR REPLACE FILTERS CHECK FOR UNUSUAL NOISE CHECK SYSTEM FOR AIR LEAKS (HOSES, HOPPER) SEMI-ANNUALLY CHECK AMP DRAW OF HEATER (SEE WIRING DIAGRAM ) PSI TO CFM CONVERSION TABLE PSI CFM DEW POINT 3 6-40 4 10-40 5 11-40 6 12-40 7 13-40 8 14-40 9 15-40 10 16-40 11 17-40 12 19-40 Revision Date 5/6/06 8 IB200602

NOTES: