PRINCIPLE MAIN APPLICATION

Similar documents
UV disinfection. System. Type A Series. Main applications: Potable water, process water, hot water/legionellae DIN EN ISO 9001 DIN EN ISO 14001

Design and manufacture process of DUV units comply with international standards for UV disinfection of potable water such as CE certificate.

Section 3: Ultraviolet - UV

SmartStream UV. Ultraviolet Water Disinfection System. Maximize Water Quality Without Chemicals. Watts.com

ULTRA-VIOLET STERILIZATION

UV I UNIT030W / UV I UNIT055W

Water temperature LBX 3 LBX 33: recommended range 5-25 C (41 77 F) LBX 90e LBX 1500e: recommended range 5-45 C ( F)

S-Series. Protect your water from pathogens and disease with the UV-Guard S-Series. Protect:

Quadron UV Series. Sustainable UV Disinfection with Minimum Footprint

Spektron UV Series SHINING NEW LIGHT ON DRINKING WATER DISINFECTION

ULTRA-VIOLET STERILIZATION

88MLV Series Open Channel Modular UV Systems

PureLine D. Technical Specification

WEDECO Quadron UV System

NANO TECH UV-C DISINFECTION SYSTEM

Intensive UV light means not a chance for germs!

Based in the UK, Triogen is a world leading company with over twenty years experience in the design and manufacture of specialist Ozone and UV

AEM EASY DRUM M A N U A L

STUNNING DESIGN AND LEADING EDGE TECHNOLOGIES COMBINE TO CREATE THE ULTIMATE WATER DISPENSER.

Ultraviolet Air Disinfection Equipment

254 Nanometer Germicidal UV Disinfection Systems

Professional Amalgam Non-regulated

VIQUA is an ISO9001:2008 registered company specializing in the design, manufacture and sale of ultraviolet systems for:

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

1020 Industrial Drive, Orlinda, TN fax

PRECAST CONCRETE. Never Looked So Good!

A measured step forward

uv and ozone for commercial pools

Model LIND30-EVO. Model. Model LIND24-EVO LIND24-EVO-2PM

PRO Series PRO10 PRO20 PRO30

Catalog of UV sterilizer

3kW 6kW, QUBE Fiber Lasers

ULTRAVIOLET INDIRECT AIR DISINFECTION

products O, UV, AOP safe water comes naturally

OptiVenn TM Series INDUSTRIAL UV SYSTEMS. High performance, cost-effective system for stringent Industrial applications

Customized Drinking Water

ULTRAVIOLET (UV) DISINFECTION EQUIPMENT: MAJOR APPLICATIONS AND GLOBAL MARKETS. IAS037C January Shalini Ramamurthy Project Analyst

Intense, cold and dry Efficient disinfection of packaging materials Premium UV solutions from Heraeus Noblelight

WATER STERILIZERS TYPE: AM1; AM2; AM3; AM4; AM5; AM6; AM8; AM10; AM12; AM15

Table of contents: Chapter V. V. Disinfection systems DOSADes

Comefresh CF-8608 Air Purifier

The reference standard in UV Proven, validated treatment solutions for disinfection and taste & odor control

Operating Manual UV Monitor UVT 18

GERMICIDAL ULTRAVIOLET FIXTURES

ULTRAVIOLET PORTABLE AREA SANITIZER

PURION UV plants for disinfection

Installation & operating manual. Swimming pool water. UV disinfection device UV10+

ieog Indirect Electrolytic Ozone Generation Technology Handbook

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

GERMICIDAL ULTRAVIOLET IRRADIATORS

Motion Sensor. For Outdoor Use. Wall & ceiling mounted. Quick & Easy Installation 2 Channels

DP-500. Target Flowmeter. Flow measurement of Gases and Liquids. Instrumentation for fluids

TROJANUVSWIFT SC. Drinking Water Treatment

Model D24-1S. Model D24-2S

for Drinking Water Systems

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

STANDARD SINGLE UV GERMICIDAL CLEANING DELUXE DUAL UV GERMICIDAL CLEANING PREMIUM DUAL UV GERMICIDAL CLEANING

SLT-Series Installation and maintenance instructions

Bernd Eichler Sales Manager

Static differential pressure measuring instruments. Pascal-ST/Z. for low measurement ranges Pa oder Pa

ADVANCE Ultraviolet (UV) Water Treatment System

Powerful and yet environmentally-friendly

NEW GENERATION INTELLIGENT ADIABATIC PRE-COOLING SYSTEM

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

PCR UV cabinets DNA/RNA

'W' HATENBOERWATER Fresh In water since l906.

UV-medium pressure. Latest manufacturing technologies for your success product. Individual is our standard

Ultraviolet Sterilizers

ENGLISH AIR160 AIR PURIFIER

For Better Hygiene around the clock

PRODUCT CATALOGUE 2011

ULTRAVIOLET WATER TREATMENT

Description FEATURES. l Innovative dual mount system requires only one sensor for either flush or surface mount applications

The SMART COOLING adiabatic precooling panels will reduce up to 30% of your cooling systems energy consumption!

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

ALPHA+ Light Exposure and Weathering Testing Instrument. Xenotest Alpha+ Features. Xenotest Alpha+ Specifications. Sample Capacity

WASTEWATER Online UV%Transmission Analyzer

PCR UV cabinets DNA/RNA

NEW GENERATION INTELLIGENT CHILLER BOOSTER, ADIABATIC PRE-COOLING SYSTEM

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

Model RS72. Model RSCS280A. Model RSM2680

Ultraviolet Water Sterilizer Installation and Maintenance Manual

INSTALLATION & MAINTENANCE

HF Series R_RevB

NEW GENERATION INTELLIGENT ADIABATIC PRE-COOLING SYSTEM

UVC GERMICIDAL TECHNOLOGY APPLICATIONS IN HOSPITALS

OMA-300 Process Analyzer

Chemical Processes in the Combustion

INCREASE YOUR LAB EFFICIENCY

It is our NATURE, We are STRONG...

Ultraviolet (UV) Water Treatment System

SHENZHEN LAMPLIC TECH CO., LTD UV LED SPOT CURING SYSTEM TECHNICAL MANUAL

ultraviolet.com Effective Virtually all microorganisms are susceptible to MIGHTY PURE TM ultraviolet disinfection.

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

ZIP HYDROCHILL High capacity chiller systems

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

UV - Monitor UVT 16. Use. Description

Transcription:

UV-C Master Blaster

PRINCIPLE Inside the UV-C Master Blaster, a UV-C radiation with a wavelength of 253.7 nm is generated, ensuring a lethal effect on bacteria (including Cryptosporidium and Legionella bacteria) and other micro-organisms like viruses, algae, yeast and mould. The UV-C radiation neutralizes bacteria, viruses and other primitive organisms and stops them from multiplying. MAIN APPLICATION Deactivation of bacteria, viruses and other micro-organisms Municipal drinking water treatment equipment Municipal waste water treatment equipment Process water treatment equipment Swiing pool units Aquaculture units Agriculture units Equipment for the production of ultra-pure water, for example for the semiconductor, pharmaceuticals and cosmetics industries. CHARACTERISTICS HDPE reactor Variable design and dimensions on request 316L Stainless steel lamp connections Flanged connection 100% draining High performance amalgam low pressure UV lamp 325W each Electronic ballasts Lamp operating indicator light, lamp alarm indicator light and alarm contact Digital lifespan indicator for UV-C lamp UV sensor at 254 nm ADVANTAGES High quality of manufacture and high disinfecting performance Use of amalgam low pressure lamps to achieve required performance levels irrespective of the temperature of the water (particularly cold water) Dedicated electronic ballasts guaranteeing maximum lamp UV efficiency and integrated control

FEATURES UV Control Unit ZCON mini Out-of-the-box control unit UV-C monitoring Status indication: Multicolour LCD Green, red and yellow LEDs Status forwarding / remote operation: Remote start input 4-20mA signal input (e.g. flow meter or diing using analogue PLC) 4-20mA signal output (e.g. UV or Dim value forwarding to PLC) 3 switching outputs (status indication or remote switching) Installation data Supply voltage: Ambient temperature: IP code: Mounting: Dimensions (LxWxD) : 100...240V AC 50-60Hz 0-40 C (32-104 F) IP00 (IP54 at front with optional front panel) to be installed in a closed cabinet 130 x 130 x 50 (5,12 x 5,12 x 1,96 inch) with optional front panel: 200 x 200 x 50 (7,87 x 7,87 x 1,96 inch) Item No. Max. Flow rate in M 3 /h DN Performance in millijoules/cm 2 at actual recoended flow rates UV-Clamp: Number power consumption Height of reactor in Diameter of reactor in XP0733252 150 150 160 44 3x 325W 1630 315 x 7.7 XP0763252 250 200 225 50 6x 325W 1630 315 x 7.7 Contact us for other flow rates

MB3X325 MB6x325

PERFORMANCE Item No. Water speed connections in m/sec Water speed in reactor in m/sec L/min M3/h mj/cm2 Exposure time in sec 0,99 0,28 1167 70 100,76 5,38 1,13 0,32 1333 80 88,17 4,71 1,27 0,36 1500 90 78,37 4,19 1,42 0,4 1667 100 70,53 3,77 1,56 0,44 1833 110 64,12 3,43 1,7 0,48 2000 120 58,78 3,14 1,84 0,52 2167 130 54,26 2,90 1,98 0,56 2333 140 50,38 2,69 2,12 0,6 2500 150 47,02 2,51 0,91 0,66 2667 160 81,41 2,24 1,02 0,7 2833 170 76,44 2,11 1,08 0,74 3000 180 72,19 1,99 1,08 0,78 3167 190 68,39 1,89 1,13 0,83 3333 200 64,97 1,79 1,19 0,87 3500 210 61,88 1,71 1,24 0,91 3667 220 59,06 1,63 1,3 0,95 3833 230 56,5 1,56 1,36 0,99 4000 240 54,14 1,50 1,41 1,03 4167 250 51,98 1,44 Note: This is a calculation, not a scientific measurement. No rights can be claimed to these calculations. Calculation is based on 98% water transmission based at lamp output at end of life. For a flow rate above the 150M3/h in combination with model MB3X325 the connection diameter will become 225.