Product Specifications

Similar documents
Technical Data Sheet 5mm Infrared LED, T-1

Technical Data Sheet 1.5mm Side Face Infrared LED

EVERLIGHT ELECTRONICS CO.,LTD.

Pyroelectric Infrared Sensors

Pyroelectric Infrared Sensors

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

A214B/SUG/S400-X6 LAMP. Features. Description. Applications. Revision 1. Expired Period: Forever. LifecyclePhase: Low power consumption

ML60171C FEATURES. φ5.6mm TO-CAN PKG (with monitor PD) APPLICATION Motion sensor Printing. Reverse voltage (PD)

Technical Data Sheet 1.6mm Side Looking Phototransistor

SPECIFICATIONS FOR REFOND SURFACE MOUNT LED

Technical Data Sheet. Pb Free. Specification NB104 SSC. Customer. Rev. 03 July 서식번호 : SSC- QP (Rev.0.

ML520G55 FEATURES. Package: φ5.6mm TO-CAN PKG APPLICATION. Reverse voltage

Technical Data Sheet 3mm Phototransistor T-1

TOCOS. Guidelines & Precautions. For Using Trimmer Potentiometers. Guidelines for Circuit Design. Guidelines for Production Processes

FSS-SMT Series. Low Profile Force Sensor

Technical Data Sheet 5mm Phototransistor T-1

Used as indicators of indicating the Degree, Functions, Positions etc, in electronic instruments

SPECIFICATIONS. US0603YG LED Chip 0603 Yellow Green SWISSDIS. Swissdis AG Grasweg 7 CH-4911 Schwarzhäusern

APPLICATION NOTES for LED DISPLAYs

Laser Collimated Beam Sensor

SURFACE MOUNT LED 405 nm, 1206 UV IL PACKAGE

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6130/6131 Series with SPI Communication

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

Preliminary specification

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6120/6121 Series

RoHS. Specification SAWW9H0A. 서식번호 : SSC-QP (Rev.00)

Pressure Sensors: Measurement Type: Gage, Vacuum Gage; Signal Conditioning: Unamplified; Pressure Range: ± 15.0 psi; Port Style: Straight

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

Application Notes For LED Displays

Reference Specification

Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Specification MBT801-S

Class 1 laser beam sensor safe for your eyes

2-wire Passive Intelligent Loop (LED) Display Meter

- For Continuous Radon Monitoring (CRM) Systems - Ultra Low Power Requirement

Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH6100 Series ±4.0 %RH Accuracy. Datasheet

Ionizer (Static Remover) STABLO-EX Instruction Manual

Gage Unamplified Noncompensated Flow-Through

Technical Data Sheet Opto Interrupter ITR

Super Mini Surface Mount Piezo Transducer

2-wire Passive Intelligent Loop (LED) Display Meter

SMD 2121 Black Frame MC-S2121BHA

FEATURES AND BENEFITS

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

ML501P73 TYPE NAME. FEATURES High Output Power: 1.0W (Pulse) 0.5W (CW) High Efficiency: 1.0mW/mA (typ.) Visible Light: 638nm (typ.) 5.

PRODUCT SPECIFICATION

Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH9000 Series ±1.7 %RH Accuracy. Datasheet

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

ML562G84 APPLICATION. Display system. Symbol Parameter Conditions Ratings Unit. Pulse (Duty 40%)

SPECIFICATION OF ANALOG MEMS MICROPHONE. ( Ultra Mini Top Port ) MODEL NO. : F1-(A)MOE-C110T42-4CP

M7100 Pressure Transducer

FIS30XXseries Gas sensor module SPECIFICATIONS

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:

Model Communication Interface Sensors 2JCIE-BL01 Bluetooth low energy Temperature, Humidity, Light, UVI, Absolute pressure, Noise, Acceleration

La Crosse Technology WT-8002U. Digital Clock with Indoor Temperature

Specifications Minimum Typical Maximum Unit

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

M5800 Pressure Transducer with Rotatable Display

Specific Lighting Product Data Sheet M08 CoB Product Series Data Sheet Spec No.: DS Effective Date: 12/15/2016 LITE-ON DCC RELEASE

PRODUCT SPECIFICATION

PRODUCT SPECIFICATION

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

General terms and conditions... F-7 General precautions... P panasonic.net/id/pidsx/global. Use as a warning. Sensor. Emergency stop.

IEC UC3 compliant (short current 3,000 A) 1 Form A 120A power latching relays

P14 Rapid Capacitive Humidity Sensor For weather balloons and radio sondes

FIS SMART SENSOR U (Draft 1) June 25, 2001

02/11/2015

TUBE DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution TUBE DRYERS

Class 1 laser beam sensor safe for your eyes

Miniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet

HM1520LF Relative Humidity Module

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

HM1500LF Relative Humidity Module

EL-USB-1-LCD Temperature Data Logger with LCD

ExplorIR -W CO2 Sensor

M5800 Pressure Transducer with Rotatable Display

Class 1 laser beam sensor safe for your eyes

MS4525 SPECIFICATIONS

Skymen Cleaning Equipment Shenzhen Co., Ltd. Ultrasonic Cleaner Instruction Manual

CM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications

Audible Alarm Basics Everything you wanted to know, but were afraid to ask by Dan O Brien, Sales Engineer, Mallory Sonalert Products, Inc.

MHTR1D Resistance humidity sensor. MHTR1D humidity and temperature sensor module Data sheet

Oxygen Sensing Solutions

Application note. LCD Module. Precautions for LCM handling. LCM handling V 1.1

TER Active Room Temperature Sensor (Controller),

SD Series Optoschmitt Detector, TO-46 Metal Can Package

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6000 Series ±4.5 %RH Accuracy

Guidelines for Analysis of Electromeric Sound Deadner (Under Seal) Silencer

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

June Humidity Sensor. CHS series

CAUTION WARNING CAUTION WARNING INSTRUCTION MANUAL 1. SAFETY PRECAUTIONS

Laser Series. Highly Visible Alignment Lasers For Visually Demanding Surfaces

HUM-M2 Humidity Sensor Module Description

Transcription:

For Reference Only Product Specifications HIS-06-N Humidity HIS-06-N Specification 2004/02/23 1/7

Contents 1. Application 2. Type Designation 3. Outline Dimensions 4. Ratings 5. Electrical Characteristic 6. Reliability tests 7. Impedance Measuring Circuit and Conversion Expression 8. Notes for Use 9. Temperature Humidity Characteristics (for Reference) HIS-06-N Specification 2004/02/23 2/7

1. Application This specification shall be applied to the relative humidity sensor element [ HIS ]. 2. Type Designation HIS - 06 - N Pb free Design No. Type Name of Humidity Sensor Element 3. Outline Dimensions +1 7 0.3 4 +/-0.5 A 10.5 +/-0.5 B C 4 +/-0.7 Typ 0.5 Typ 0.25 Typ 2.5 Unit : mm No. Name Material and Specification A Humidity Sensor Manufactured by Hokuriku Electric Ind. Co., Ltd. HIS-06-N (Protected Coat Goods) B Case Polypropylene (Translucence) C Lead Terminal PBR (Solder Plating(Pb free)) HIS-06-N Specification 2004/02/23 3/7

4. Ratings No. Item Rated Value 1 Rated Voltage The sine wave or square wave of AC 0 to 5V. 2 Rated Power 1.0 mw 3 Storage Temp. Range -25~+70 4 Storage Humidity Range 0~90 %RH (Do not let it have dewdrops.) 5 Operating Temp. Range -20~+60 6 Operating Humidity Range 20~90 %RH (Do not let it have dewdrops.) 7 Humidity Detection Range 0~ 45 20~90%RH Environment Conditions of Humidity Sensor [HIS-06 Environment Conditions of Humidity Sensor [HIS-06-N] Storage Probable Range Operating Probable Range Humidity Detection Range 100 90 80 Relative Humidity (%RH) 70 60 50 40 30 20 10 0-40 -30-20 -10 0 10 20 30 40 50 60 70 80 90 Temperature (Deg.C) 5. Electrical Characteristics The temperature condition regarding the table below is 25 degree and the measurement method indicated in item 7 (Impedance Measuring Circuit and Conversion Expression) shall be used. Item Conditions Min. Typ. Max. Unit Humidity 26.6 80.0 Detection Output 50 %RH 45.8 K.ohm (+5%RH) (-5%RH) (Accuracy) Hysteresis Characteristics 30 to 90 %RH - ±1 - %RH Humidity Response Characteristics 30%RH to 90%RH (90% arrival) Wind speed 1.2 cm/sec. - 3.5 - minutes HIS-06-N Specification 2004/02/23 4/7

6. Reliability Tests No. Test Item Test Condition Criteria 1 Drop Test Drop the test piece naturally 3 times from the height of 1 m onto the lauan material of 30 mm thickness. 2 Lead Traction Intensity 3 Lead Bending Intensity 4 Solder Heat Resistance The weight of 1 Kg is applied to the lead wire in the direction parallel to the sensor for 10 seconds. The sensor is held vertically, and the weight of 250 g is hung from the lead wire end. The sensor is bend in right angle, and returned to the original shape, and next bend in the same way to the reverse direction, and returned to original shape. Do soldering of 5 +/-2 seconds long on the lead terminal 1.6 to 3.6 mm away from the case side with soldering iron tip temperature 320 +/-10 deg.c. 5 Heat Shock The samples are subjected to 10 cycles of 60 minutes exposures of each of -25 degree and +70 degree. (Do not let it have dewdrops.) 6 Exposure to High Temperature 7 Exposure to High Humidity 8 Exposure to Low Temperature 9 Exposure to Low Humidity The samples are exposed to a temp. of +70 degree for 1000 hrs. The samples are exposed to a temp. of +40 degree with 95 %RH for 1000 hrs. The samples are exposed to a temp. of -25 degree for 1000 hrs. The samples are exposed to a temp. of +25 degree with 20 %RH for 1000 hrs. 10 Load Life The samples are subjected to consecutive electric load of AC 5V(1 khz) at normal temperature and humidity for 1000 hrs. The sample shall not have any abnormality in the appearance and the humidity detection output shall be in the electric characteristics of item 5. It should be without cominig-off of the terminal and within the electric characteristics of item 5. The variation of the humidity detection output shall be within +/-5 % against the initial value. Note 1 ) The measurement of the humidity detection output is done after 15 minutes have passed with the advantage way type precision humidity producing device after the temperature humidity setting. Note 2 ) The measurement of the reliability test parts is done after they are left for more than 2 hours in the normal temperature and the normal humidity. HIS-06-N Specification 2004/02/23 5/7

7. Impedance Measuring Circuit and Conversion Expression R1 R1 = 10 K.ohm to 100 K.ohm Z = (R1 x Vx) /(Vin Vx) Vin 3 to 5V HIS Z D.V. Vx 8. Notes for Use (1) This product has been processed to have water-resistant coating and even if a small amount of water sticks to the part, the humidity sensing membrane will not melt away. However please do not use this part under an environment where water adhesion or dewing occurs for a long period of time or frequently. (2) Do not make foreign materials such as a solvent, oil and fat stick to the humidity sensor. It may stop fulfilling normal features. (3) Please do not bend and extend the lead terminal more than once. (4) Attachment by flow soldering or re-flow soldering is not possible. (5) Please solder the terminal 1.6 mm or over away from the case side with the iron tip temperature 320 +/-10 deg.c within 5 seconds. (6) This part cannot be used by the DC power source. (7) Do not use for medical apparatus (application involving risk of affecting life). HIS-06-N Specification 2004/02/23 6/7

9. Temperature Humidity Characteristics (for Reference) By the measuring circuit of the item 7. Frequency : at 1 KHz Temp. (Deg.C) Relative Humidity (%RH) (K.ohm) 20 30 40 50 60 70 80 90 5 68057 4915 824.0 218.5 72.27 28.15 12.09 5.35 10 35993 3076 566.4 151.4 49.94 19.30 8.21 3.70 15 19368 1906 375.3 99.10 33.47 13.36 5.70 2.70 20 10780 1130 240.0 68.00 22.70 9.60 4.33 2.08 25 5916 694 149.9 45.80 16.00 7.00 3.28 1.68 30 3450 420 94.6 31.00 11.30 5.20 2.60 1.42 35 2053 268 60.6 21.18 8.05 3.83 2.08 1.20 40 1235 172 41.8 14.97 6.11 3.00 1.71 1.05 45 740 115 30.2 11.01 4.76 2.43 1.46 0.93 100000 5 10 15 10000 20 25 30 O utput Im pedance (K.ohm 1000 100 10 35 40 45 1 0.1 10 20 30 40 50 60 70 80 90 100 HIS-06-N R Specification e la tiv e H u m id ity (% 2004/02/23 R H 7/7