SP-220. Features. Combustible handheld gas leakage detector

Similar documents
Portable Gas Leak Detector SP-220 Series TYPE FUM TYPE SC Operating Manual

PT0E Portable Gas Leak Detector. SP-220 Series. Operating Manual (PT0E-139)

OLC(T) 100 FIXED GAS DETECTOR

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

3M Oldham OLCT 100. Description. Fixed Gas Detector

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

ESD500. ESD500 Combustible / Toxic Gas Detector

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

ESD3000 ESD200 Combustible / Toxic Gas Detector

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

Sieger Apex. Flexibility that meets your requirements

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

ALTAIR 5X Multigas Detector

Monitores Personales. Personal Monitor

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Toxic Gas Detection. Model F12. Toxic Gas Detection

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

MICRO III (G202 / G202s / G212) Single Gas Detector

Gas Detection For Life

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Micro III (Models G203, G203S, and G213) Operation Manual

Xgard. Fixed detectors For flammable, toxic or oxygen gases

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

VASTHI ENGINEERS. Vasthi Multi Gas Monitor/Analyzer. Sheet No. 1 of 4. Vasthi Multi Gas monitor/analyzer with alarm and Graphical Display.

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

ALTAIR 5X Multigas Detector Product Specification

MICRO IV. Operation Manual. Single Gas Detector

Satellite XT. Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Micro IV. Single Gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

Model D12. Digital Gas Transmitter

GAS DETECTOR ST400EC PART.NO

E1000 Portable gas detector

SC-01 Operator s Manual

Frequently Asked Questions

MODEL: SP2nd (Portable Single Gas Detector) Operating Manual

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

IMR EX610. Portable Gas Detector. Operation Manual

FX-SMT Series INSTRUCTION MANUAL P/N THERMO ELECTRON CORPORATION ENVIRONMENTAL INSTRUMENTS 27 FORGE PARKWAY FRANKLIN MASSACHUSETTS 02038

Installation and Wiring 1.

Single Gas Detector. Long-term solution H 2 S O 2 SO 2 NH 3 PH 3. Cl 2. ClO 2 NO 2 HCN ETO O 3

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

Low mg/m

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

ALTAIR 5X Multigas Detector

G-TECTA TM. Portable Gas Detection Instruments

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

Micro IV Operation Manual

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

APPLICATION DATA SHEET

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

MERIDIAN UNIVERSAL GAS DETECTOR

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

Safe Operation Manual. Honeywell IQ Force Gas Detector

Portable Combustible Gas Detector GP-1000 Operating Manual (PT0-120)

Portable Gas Leak Detector SP-220 Series TYPE F Operating Manual

UniSens 2-Wire Gas Transmitter

Meridian. Universal Gas Detector. Description. Features. Minimal drift High specificity Digital ID Broader toxic gas detection

Dräger Pac 8000 Single-Gas Detection Device

NGD8800 USER S MANUAL

GasAlertMicroClip X3 Specifications

Equipment. Model R002. Description. SF6 leak detector

Understanding the practicalities of using gas detectors in confined spaces

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Stand Alone DYNAGARD SP Operation Manual

MODEL: Q8 SERIES NON-INTRUSIVE CALIBRATION GAS TRANSMITTER/SENSOR

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

MICRO IV. Installation & Maintenance Instructions. (G221 / G222 / G223) Single Gas Detector

The GasWatch 2 will operate for over 3,000 hours on one battery (about 1 year normal use). And yes, the GasWatch 2 even tells the time!

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

UniSens. 2-Wire Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

Gas Detection. Honeywell BW Solo. The next generation in portable single gas detection.

Model GX Operator s Manual

IMR IX176 Portable Gas Detector User Manual

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

MSA XCell Sensors. Because every life has a purpose

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

The Dräger X-am 1700/2000 are a new generation of personal gas detectors.

Gas detector tubes are most effective as a reference device for conducting spot checks, which gives an idea of present gas at that moment in time.

Leak detector for refrigerant gases R22, R134a, R410A, R407C...

Toxic Smarter Transmitter Instruction Manual

and storage tanks. CO and NOx detection from diesel engine emissions Hospitality Hotels and restaurants LPG detection in commercial kitchens

VENTIS PRO SERIES. Product Guide

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

PRODUCT CATALOG 2016 PT. Victoria Globalindo Teknik PT. Victoria Agfasindo

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

ENMET Corporation. PO Box 979 Ann Arbor, MI MX Operation and Maintenance Manual. Manual Part Number MCN-407, 09/30/08

GMA 36 Pro. Operation Manual. Stand Alone Monitor

Portable Instrument Application Guide

Transcription:

SP-220 Combustible handheld gas leakage detector The SP-220 gas leakage detector is a simple to operate unit with high sensitivity to a variety of gases. The SC version (SP-220SC) is able to detect super-toxic, combustible and Freon based gases - a total of 40 altogether! An alternative variant exists specifically for fumigation type gases (SP220). Features Easy grip & robust structure Target gas selectable from a list of 40 gases (Type SC) and 7 gases (Type FUM) Calibration to only one gas (PH 3 ) is needed Data logging / Snapshot logging High speed, low concentration readings Sensor detects as low as 0.1ppm Up to 12 hours of continuous operation Impact-resistant rubber protective over-mold IP-55 Two (2) visual LED alarms LED torch light

Technical specifications SP-220 FUM & SP-220 SC Model SP-220 TYPE FUM (Fumigation) SP-220 TYPE SC (Toxic, Combustible, CFC) Target gas Detection principle Sensor Measuring range Alarm set point Accuracy Alarm pattern Alarm method Display of alarm Alarm delay time Sampling method Response time Output signal Refer to the gas list Hot-wire semiconductor method SH-8662 Depends on target gas Depends on target gas Displays 0.1 ppm-bar when applied PH3 0.3 ppm. Gas alarm: Gas concentration reached or over the setting point. Trouble alarm: Sensor connection / breaking, Low battery, Low flow, Circuit error, Calibration Non-latching Gas alarm: Flashing LED, Buzzer Trouble alarm: Flashing LED, Buzzer, Display of error message 0 sec. Sample draw 10 sec.: Time to reach 0.1 ppm when applied PH3 0.3 ppm. IrDA Switch AIR MODE POWER Display device Display contents Power source Continuous operation Operating temp. & humidity LCD Gas name, Gas concentration, Time, Battery, Pilot indicator, Pump driving indicator 2 AA dry cell batteries More than 12 hrs. -20~+55 C (-4 F~+131 F), 0~95%RH(Non-condensing) 200mm(H) x 43mm(D) x 47mm(W) (Taper nozzle not included), 215g Dimension & weight IP 55 Ingress proof Function Manual LCD backlight (Automatically ON when alarming), Peak value, Snap logging, Time, Cal alarm

Technical specifications SP-220 M, L & ML Model SP-220(TYPE M) SP-220(TYPE L) SP-220(TYPE ML) Detection principle Hot-wire semiconductor method Target gas Town gas (switchable to LPG) LPG (switchable to town gas) Town-gas, LPG (switching) *2 gases are needed for calibration. Concentration display Measuring range Sample draw Alarm set point Display Response time Gas alarm display Gas alarm method Trouble alarm Trouble alarm display Trouble alarm method Power source Continuous operation Operating temperature Operating humidity Safety design Approvals Ingress proof Dimension Weight LCD level meter + Scale 10~10000ppm Sampling method Default: 30ppm (selectable from 10,30,150,500,2000ppm) Operating state disp., Flow check disp., Gas concentration disp., Alarm sound disp., Operation sound disp., Battery level icon, Level meter disp., Mode disp., Gas name and message disp. 3 sec. Flashing LED, Buzzer Non-latching Sensor error, Low battery, Low flow, System error, Calibration error, Clock error, Pump error Flashing LED, Buzzer, Trouble message Latching 2 AA dry cell batteries Approx. 13 hrs. -20~55 C (-4 F~131 F) 0~95%RH (Non-condensing) Intrinsically safety ExiaIICT4 Ex-proof: IECEx, ATEX / Other: CE marking IP55 200(H) 43(W) 39(D)mm (Taper nozzle not included) 215g (Dry cell batteries not included)

Target Gas for SP-220 Concentration No. Gas name Display Display 1 Display 2 1 Phosphine PH 3 0.1 2 2 Acetone C 3 O 3 Arsine AsH 3 0.2-4 Ammonia NH 3 10-5 Isobutane i-c 4 H10 6 Isopropyl alcohol IPA 7 Carbon monoxide CO 10 30 8 Ethyl alcohol C 2 H 5 OH 9 Ethylene C 2 10 Vinyl chloride VCM 1-11 Methyl chloride CH 3 CL 12 Xylene C 8 H 10 13 Ethylene oxide EO 14 Silane Si 0.5-15 Methyl bromide CH 3 Br 1 20 16 Hydrogen H 2 17 Trichloroethylene C 2 HCL 3 10-18 Toluene C 7 H 8 19 1,2-Dichloroethane EDC 20 Sulfur dioxide SO 2 1-21 Propane C 3 H 8 5 20 22 R-134a R-134a 50 250 23 R-22 R-22 10 50 24 R-32 R-32 10 50 25 n-hexane n-c 6 H 14 10 50 26 Benzene C 6 0.5 10 27 Formaldehyde HCHO 10 50 28 Methane C 1 20 29 Methyl alcohol CH 3 OH 30 Methyl ethyl ketone MEK 31 Hydrogen sulfide H 2 S 0.1-32 Diborane B 2 0.1-33 Germane G e 0.2-34 Hydrogen bromide HBr 10-35 Hydrogen chloride HCL 10-36 R-407C R-407C 10 50 37 Hydrogen selenide H 2 Se 0.5-38 R-410A R-410A 10 50 39 R-404A R-404A 10 50 40 2,3,3,3-Tetrafluoropropene CH 2 C 2 F 4 10 30 Note 1: Means there is sensitivity, but no value can be given. Note 2: Alarm accuracy, response time etc. are confirmed with calibration gas (PH3) Note 3: The measuring results of the gas selection are intended for guidance only. The most accurate measurement is for calibration gas (PH3). No. Gas name Display Display 1 Concentration Display 2 Display 3 1 Phosphine PH 3 0.1 2 4.05 2 Methyl bromide CH 3 Br 1 20 100 3 Carbon disulfide CS 2 0.1 - - 4 Methyl iodide CH 3 I 30 5 Hydrogen cyanide HCN 1 - - 6 Sulfuryl fluoride SO 2 F 2 - - 800 7 Ethylene dibromide C 2 Br 2 30 www.bruusgaard.no postmaster@bruusgaard.no +47 67 54 93 30 Rev: 436-1

The Bruusgaard System TBS is a unique turnkey portable gas detection solution, giving you increased safety and substantial cost savings through standardised instruments, routines, training and procurement. Logistic Support At any given time we know the status of all vessels and sites covered by The Bruusgaard System. We consolidate all shipments and make sure you have everything you need on board until next scheduled delivery. This results in fewer shipments and substantial savings! Year round follow up of instruments, spares and consumables Handling of all shipments & logistics Annual reports per vessel including budgeting Instruments All the equipment used for gas detection and calibration is placed in a custom-made wall cabinet. Including Log & Instruction Manual, which are crucial to maintaining the safety integrity. Standardised vessel specific gas detector solutions Total solutions including all equipment and routines necessary for efficient and safe use, storage and maintenance Cost Savings Some of our customers have been able to go from 8 to 10 suppliers down to 1 translating into cost savings of up to 40-50%. For one vessel, this could be thousands of dollars annually, and for a whole fleet, the cost savings can be dramatic. This is achieved through: Safety QA strict routines and logging Crew are able to use instruments and follow routines correctly Instruments are in proper working condition at all times Instruments are calibrated at correct intervals Sensors and other items are replaced at correct intervals Usage of instruments is logged, including abnormal observations Traceability instrument history and usage Routines and procedures can merge into the overall QA-system One contact for worldwide supply of spares & gases All service and calibration can be done on site. Reductions of instrument types from 10-12 to 2-3 Reduced maintenance costs through: On board calibration Fewer instruments on board No need for spares on board One PO per year Increased safety Less use of administrative time Effective and proven training is an integrated part of The Bruusgaard System. www.bruusgaard.no postmaster@bruusgaard.no +47 67 54 93 30