LED Explosion proof Torch Light. Ex Marking:Ex ibⅡc T4 Gb Ex ib ⅢC T130 Db IP 68. KHJ-LED Explosion Proof Lighting

Similar documents
LED Explosion proof Por table light

Ex Mark:Ex d eb ⅡB T6 Gb

INTRINSICALLY SAFE LIGHTING RANGE

Specification Sheet. Certificates. Features. Application. Anti-Explosive Lamp

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

LED NEW FB-SERIES LED NEW-SF FIXTURE LED NEW-SD FLOODLIGHT LED NEW-SD STREET. LED Explosion-proof Platform Light. LED Tri-proof Light

High Quality LED Lighting!

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

OLUX LED Flood Light OSRAM. Datasheet APPLICATIONS.

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

LED Explosion Proof MXL-90/100/120 MXLK-45/60/80

High bay LED lighting fixture

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

Technical Application Guide for UP-SHINE LED Spotlight

OLUX LED IN-GROUND OSRAM. Datasheet

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof

CCA-03EX. - Easy installation - Low energy consumption - New COB LED technology - Zone 1, 2, 21, 22. Directional LED spotlights

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

XLFE-4/1. Borosilicate glass globe

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Urbanlite. We light your world IK08 IP

ATEX. Wolf Safety Lamp Company. The widest range of portable ATEX lighting approved for use in explosive atmospheres

SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending

Technical Application Guide for UP-SHINE LED wall lamp UP-WL08-8W

Specification. Date Version V1.2. Foshan NationStar Optoelectronics Co., Ltd. LED Lighting Branch DRAFT CHECK CONFIRM

SafeSite LED Area Light - ATEX / IECEx. for Indoor and Outdoor Industrial Applications

40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated

ATEX. Wolf Safety Lamp Company. Includes NEW LinkEx LED. The widest range of portable ATEX lighting approved for use in explosive atmospheres

BC9700 series High Power LED Explosion Proof Light

Explosion Proof Light - Base Stand Mount - 16 Inch Watt LED - Class I Div 1 C&D

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

distributed by Sole Agent in Great China Universky (Jiangsu) Technologies, Inc. Phone: Fax:

LUXCOMFO TM LED Flood Light Datasheet

48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2

Vaya Linear LP, White & Mono

FLASHLIGHT ANSI STANDARDS

SPARTAN SPX-HPBY LED Zone 1 Bay Light - IIB Applications

Safe Operation Manual. Honeywell IQ Force Gas Detector

PRODUCT OVERVIEW. Light fittings, boxes & custom built control panels for explosive atmospheres

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

PRODUCT DATA SHEET ilh8

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

Albeo LED Luminaire. Heavy Industrial Low Bay Lighting. (ALR1 - Series)

0118M Series. Vision For Future LED SURFACE MOUNTED PANEL LIGHT WITH SENSOR OPTION. High light efficiency Energy saving Long life

Technical Application Guide for UP-SHINE LED Panel Light

EXPLOSIONPROOF LED LIGHT FITTINGS TO USE IN ZONES 1,21 & 2,22 KDB 15ATEX0049X NEW

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications

LED ECO PANEL.

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

LED Panel Light Specification List

WARRANTY LED ECO PANEL.

STRUCTURED LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED

Explosion Proof Emergency Fluorescent Light Combination - Dimmable Ballast - C1D1-2 T8 lamps - 4'

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated

Mustang Vaporizer. Installation, Operation & Maintenance MV

Certificate of Compliance

Operating Instructions

Explosion Proof LED Light - Equivalent to Watt HID C1D2, UL Listed

Technical Application Guide for UP-SHINE LED Panel Light

WZ-T8-W18 T8 LED Tube Light

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

User s Manual YTA610 and YTA710 NEPSI Certification

Rating. Class I Div II

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-AN

Fan Heaters Type VLEx

300W EXP LED Light - 35,000 Lm - 3' Cart Mount - Quick Change Mount - C1D1-100' 16/3 SOOW- EXP Plug

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

110 lm w STANDARD SERIES

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

FLASHLIGHT ANSI STANDARDS

manual addendum DELPHI Ex

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-E

Technical Application Guide for UP-SHINE LED Panel Light UP-PL W-L

SECTION INTERIOR LIGHTING

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

LaserMethane mini (LMm)

GasAlertMicroClip X3 Specifications

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09

Products for the area

Certificate of Compliance

Dimmable LED Retrofit Kit

Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

DTS Light fittings for explosive atmospheres

Challenges in SSL Design and Photometric testing Gautam Brahmbhatt, Head Technical (Verification Service)

GSM S EX PLUS. Maximum lone working protection in areas with explosive substances. II 2 G D Ex ib IIC T4 Gb. Position alarm.

Dräger Polytron 5720 IR Toxic Gas Detection

JAMIN 100. Compact impervious luminaire for ATEX zones. Zones 2, 21, 22

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Technical Application Guide for UP-SHINE LED Panel Light

OPTIBAR DP 7060 Supplementary Instructions

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

LED Tri-proof Light. LED Tri-proof Light SPEC. Microwave Motion Sensor. Option: Remote control. Suitable for a variety of scenes

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

Transcription:

Alcidae Series LED Explosion proof Torch Light Ex Marking:Ex ibⅡc T4 Gb Ex ib ⅢC T130 Db IP 68 KHJ-LED Explosion Proof Lighting 1

INTRODUCTION Features and benefits 1.Made of top famous LED source Cree/OSRAM,high efficacy, long lifespan, maintenance free. 2.High-strength aluminum alloy enclosure is smoothly sculpted for a comfortable and secure grip, extreme resistance to abrasion and corrosion,ip68. 3.High quality tempered glass with excellent light transmittance. 4.Designed with advanced optical principle,making visual distance up to 200m. 5.Three stages click-type switch: high output,working output, and flashing light. 6. Constant current ensures brightness stability 7. Lithium batteries : large power capacity, long lifespan. Application: 1.Petroleum Industry, Petrochemical Industry, Metallurgical Industry, Power Generation Industry, Power Transmission Industry, Railway Industry, Public Security and Fire Fighting, etc. 2.Petroleum and petrochemical, aircraft, military, outdoors, indoors, portable emergency kits. Executive standard: IEC 60079-0:2007 IEC 60079-11:2006 EN 60079-0:2007 EN 60079-11:2007 EN 60598-1:2008+A11:2009 EN 55015:2013 IEC 62321:2008 Division: ATEX Zone 1 & 21 and 2 & 22 Class Ⅰ Divison 1&2 Groups A B C D Class Ⅱ Divison 1Groups E F G Class Ⅱ Divison 2Groups F G Class Ⅲ Divison 1 Class Ⅲ Divison 2 Certifications and Ratings: Ex ib IIC T4 Gb; Ex ib lllc T130 Db IP 68 ATEX Compliant CE Compliant RoHS Compliant IP 68 Rated 12

CHARACTERISTIC DETAILS Three stages Click-type switch:high output, working output, and flashing light. Lithium batteries: large power capacity, long lifespan. Designed with advanced Optical Principles, making visual distance up to 200m. High-strength aluminum alloy housing is smoothly sculpted for a comfortable and secure grip, extreme resistance to abrasion and corrosion, IP68. OSRAM/Cree LED source, high efficacy lumen output. CHARACTERISTIC DETAILS 13

PERFORMANCE PARAMETER Electrical Parameter K AC F XX X XX -X Brand Series Type Candela Distribution Housing Color CCT(K) Area K-KHJ F-Torch Light(Flashlight) G-Gray E-English AC-Alcidae 80-80 WM-2700~3300K NH-3700~4300K CH-5400~6400K Electrical Parameter Product type Rated input voltage(v) Rated battery capacity(ah) Battery working time(h) Battery charging time(h) Battery lifespan Flashing frequerncy(hz) High output work light KACF80 3.7 2.2 9 18 6 300(cycles) 5 Photometric Parameter Product type P/N Color temp. CCT(K) CRI Luminous flux(lm) Spotlight beam angle ( ) Floodlight beam angle ( ) KACF80 KACF80GWM-*-E Warm white 2700~3300 82 129 KACF80GNH-*-E Natural white 3700~4300 70 157 KACF80GCH-*-E Cool white 5400~6400 70 157 10 80 Other Parameter Product type Size(mm) Weight(Kg) Ambient temp.( ) code Temp.classification Insulation KACF80 φ35* 156 0.19-20-+55 IP 68 T4 Ⅰ 14

SIZE Size(unit:mm) 156 ACCESSORIES NO. Name Picture Weight(Kg) QTY 1 Car charger 0.12 1 2 Charger 0.06 1 15

SERVICE Caution 1.To avoid the risk of fire, explosion, or electric shock, this product should be installed, inspected, and maintained by a qualified electrician only, in accordance with all applicable electrical codes. 2.To avoid electric shock: Be certain electrical power is OFF before and during installation and maintenance. 3.To avoid explosion: 1)Make sure the supply voltage is the same as the luminaire voltage. 2)Do not install where the marked operating temperatures exceed the ignition temperature of the hazardous atmosphere. 3)Do not operate in ambient temperatures above those indicated on the luminaire nameplate. 4)All gasket seals must be clean. 5)Before opening, electrical power to the luminaire must be turned off. Keep tightly closed when in operation. Package Check 1. Check the carton and all the components according to the packing list. 2.Make sure the product is in good conditions. Transportation Please keep this product from heavy mechanical shock, exposure to strong sunshine, throwing, rolling and stress during transport. Storage: Kept in dry,clean and well-ventilated,non-corrosive medium warehouse,the ambient temperature should be -20 to 55. After-sales service Installation and maintenance must be according to the instruction. If customer can not deal with it by themselves,please contact with sales department. Contact SHENZHEN KHJ SEMICONDUCTOR LIGHTING CO., LTD. -------------------------------------------------------------------------------- Address: 4-5 Floor, Building 1,Chuangxin industrial park,xintian community,guanlan, Longhua new district, Shenzhen,China. Tel: +86-755-82949977 Fax: +86-755-82949800 E-mail: khjledsales@khj.cn Web: www.khjled.com 16