Java Development Program on Parallel and Counter Flow Heat Exchanger

Similar documents
Design, Development & Testing of Double Pipe Heat Exchanger With Heat Transfer Enhancement Liners

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

Design and Experimental Analysis of Concentric Tube Heat Exchangers with Various Fins

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Performance Study of Triple Concentric Pipe Heat Exchanger

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

ANALYSING THE EFFECTIVENESS OF THE HEAT EXCHANGER BY INCREASING OVERALL HEAT TRANSFER COEFFICIENT

CHAPTER 7 COMPARISON OF HEAT EXCHANGERS

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Influence of Pressure Drop, Reynolds Number and Temperature in the Design of Double Pipe Heat Exchanger on Cold Fluid Side in Outer Pipe

DESIGN AND ANALYSIS OF PIPE HEAT EXANGERS WITH INSIDE FINS

HEAT EXCHANGERS. Heat exchangers are broadly classified based on the following considerations.

As we discussed early in the first chapter that heat can transfer through materials and the surrounding medium whenever temperature gradient exists

Experimental Comparison of Natural Convection Heat Transfer from a Blackened V-Fin Array

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

CL4001 HEAT TRANSFER OPERATIONS

Design and Development of Water Cooled Condenser for Domestic Refrigerator

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

How is the heat transfer?

IMPROVE THE EFFICIENCY OF HEAT EXCHANGER IN OIL COOLER.

Enhancement of COP in Vapour Compression Refrigeration System

STUDY, ANALYSIS AND DESIGN OF AUTOMOBILE RADIATOR (HEAT EXCHANGER) PROPOSED WITH CAD DRAWINGS AND GEOMETRICAL MODEL OF THE FAN

Design, Manufacturing of Chilled Water System for Process Cooling Application

Keywords: Triple tube heat exchanger (TTHE), hot water, cold water, CFD simulation.

Gandhinagar Institute of Technology Mechanical Engineering (Thermal Engineering) Semester II. Design of Heat Exchange Equipments [ ]

In the name of God. Jami Institute of Jami - Mehdi Rasti

A Study of Heat Transfer Using Corrugated Al 2 o 3 microparticles

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) AN EXPERIMENTAL STUDY OF HEAT TRANSFER IN A CORRUGATED PLATE HEAT EXCHANGER

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Experimental analysis of condensation heat transfer enhancement of steam at low pressures using modified twisted tape insert

Design of Air Pre-Heater for Blast Furnace Gas Fired Boiler

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

COMPARATIVE ANALYSIS OF SINGLE AND DOUBLE EFFECT LiBr-WATER ABSORPTION SYSTEM

Analysis of a Condenser in a Thermal Power Plant for Possible Augmentation in its Heat Transfer Performance

An Experimental Study on Clothes Drying Using Waste Heat from Split Type Air Conditioner

Sant Gadge Baba Amravati University. Amravati, Maharashtra, India, Maharashtra 2

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

CFD Analysis of Double Pipe and Triple Pipe Heat Exchanger

International Journal of Scientific & Engineering Research, Volume 5, Issue 7, July-2014 ISSN

Design and analysis of household direct cool refrigerator with vertical evaporator

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Waghmare Tushar Ramrao, D.S.Nakate

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 04, 2016 ISSN (online):

EXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE

HEAT TRANSFER ENHANCEMENT IN SHELL AND TUBE HEAT EXCHANGERS USING INSERTS

Safety Hazards Thermal Systems Laboratory Rooms 106 & 110

THE GATE COACH All Rights Reserved 28, Jia Sarai N.Delhi-16, ,-9998

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

An Optimized Plate Fin Type Heat Exchanger

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

I. INTRODUCTION. Types of Fins:

Reheating Refrigeration System

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Solar air heater duct having triangular protrusions As roughness elements on absorber plate

DESIGN AND MANUFACTURING OF CHEMICAL AGITATOR

Adsorption refrigeration system using waste heat

STUDY OF HEAT TRANSFER IN A CORRUGATED PLATE HEAT EXCHANGER USING AL 2 O 3 MICROPARTICLES

CFD ANALYSIS OF DOUBLE PIPE PARALLEL FLOW HEAT EXCHANGER

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

2. HEAT EXCHANGERS MESA

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Numerical Analysis of the Bearing Capacity of Strip Footing Adjacent to Slope

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Performance Analysis Of Double Inclination Ribbed Solar Air Heater Rectangular Duct By Liquid Crystal Thermography

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Mechanical Engineering Department Sheet (1)

Experimental Investigation of Heat Transfer Enhancement from Waveform Pin-Fins

American International Journal of Research in Science, Technology, Engineering & Mathematics

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

[Jhansi, 5(10): October 2018] ISSN DOI /zenodo Impact Factor

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

Global Journal of Engineering Science and Research Management

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

THERMODYNAMIC PERFORMANCE EVALUATION OF AN AIR-AIR HEAT PIPE HEAT EXCHANGER

ENSC 388: Engineering Thermodynamics and Heat Transfer

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

Modified Air Cooler with Split Cooling Unit

A Review on Comparative Study of Thermal Performance of Artificially Roughened Solar Air Heaters

Thermal Analysis of Concentric Tube Heat Exchanger Using Louvered Strip Inserts

WASTE HEAT RECOVERY FROM DOMESTIC REFRIGERATOR Soma A. Biswas 1, Sandeep M. Joshi 2 1,2 Pillai College of Engineering

EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE

PERFORMANCE EVALUATION OF TWO STAGE AIR COOLER IN DIFFERENT SPEED

Influence of Feed Water Heaters on the Performance of Coal Fired Power Plants

Design & Development of Tube in Tube Helical Coil Heat Exchanger

Transcription:

Java Development Program on Parallel and Counter Flow Heat Exchanger Mr. Tanmay Sahuji 1 Dept of Mechanical Engineering Walchand Institute of Technology (WIT), Solapur, India. Mr. Pritish Chitte 3 Assistant Professor, Dept of Mechanical Engineering Walchand Institute of Technology (WIT), Solapur, India. Abstract The concept of heat exchangers plays a major role in the refrigeration and air conditioning system.this project discusses about the parallel flow and counter flow heat exchanger using LMTD and NTU effectiveness method. The main objective of this project is to calculate theoretical parameters of heat exchanger like Effectiveness, Area, Inlet and outlet temperatures, Log mean temperature difference (LMTD), Number of Transfer units (NTU), by using concepts of OOPs & java. To calculate this all parameters java program is done on the parallel and counter flow heat exchanger. Keywords LMTD, NTU, Java, Parallel flow heat exchanger, Counter flow heat exchanger. I. INTRODUCTION A heat exchanger may be defined as an equipment which transfer the energy from a hot fluid to cold fluid, with maximum rate and minimum investment and running cost. In heat exchanger the temperature of each fluid changes as it passes through the exchangers, and hence the temperature of the dividing wall between the fluids also changes along the length of exchanger. In heat exchangers the temperature of each fluid changes as it passes through the exchangers, and hence the temperature of the dividing wall between the fluids also changes along the length of the heat exchanger. A. Classification of Heat Exchanger In order to meet the widely varying applications, several types of heat exchanger have been developed which are classified on the basis of nature of heat exchange process, relative direction of fluid motion, design and constructional features, and physical state of fluid. Following two types of heat exchanger which are classified on the basis of relative direction of fluid motion are the area of interest of this Article. Mr. Prasad Suryawanshi 2 Dept of Mechanical Engineering Walchand Institute of Technology (WIT), Solapur, India. Mr. Sudeep Paniyadi 4 Associate Engineer, Cognizant Technology Solution, Pune, India. 1. Parallel flow heat exchanger In parallel flow heat exchanger, as the name suggest, the two fluid streams (hot and cold) travel in the same direction. The two streams enter at one end and leave at bother end. It is evident from fig.2 that the temperature difference between the hot and cold fluids goes on decreasing from inlet to outlet. Since this type of heat exchanger needs a large area of heat transfer, therefore, it is rarely used in practice. As the two fluids are separated by a wall, this type of heat exchanger may be called parallel flow recuperator or surface heat exchanger. Fig.1 Representation of Parallel Heat Exchanger Fig.2 Temperature Distribution of Parallel Flow Heat Exchanger 222

2. Counter flow heat exchanger In a counter flow heat exchanger, the two fluids flow in opposite directions. The efficiency of counter flow heat exchanger is higher than parallel flow heat exchanger. Temperatures within the two streams tend to approach one another in a nearly linearly fashion resulting in a much more uniform heating pattern. The maximum temperature difference across the exchanger wall thickness (between the wall surfaces exposed on the hot and cold fluid sides) either at the hot- or cold-fluid end is the lowest, and produce minimum thermal stresses in the wall for an equivalent performance compared to any other flow arrangements. Fig.3 Representation of Counter Flow Heat Exchanger Fig.4 Temperature Distribution of counter Flow Heat Exchanger 3. LMTD & NTU Method To determine the temperature driving Force for heat transfer in flow system of heat exchanger Logarithmic mean temperature difference is used. The LMTD is a logarithmic average of the temperature difference between the hot and cold feeds at each end of the double pipe exchanger. The larger the LMTD, the more heat is transferred. The use of the LMTD arises straightforwardly from the analysis of a heat exchanger with constant flow rate and fluid thermal properties. The Number of Transfer Units (NTU) Method is used to calculate the rate of heat transfer in heat exchangers (especially counter current exchangers) when there is insufficient information to calculate the Log-Mean Temperature Difference (LMTD). In heat exchanger analysis, if the fluid inlet and outlet temperatures are specified or can be determined by simple energy balance, the LMTD method can be used; but when these temperatures are not available The NTU or The Effectiveness method is used. It is a dimensionless parameter. II. LITERATURE SURVEY Prabhat [1] studied on a performance evaluation of counter flow heat exchanger considering for low temp application. He found those Counter flow heat exchangers are commonly used in cryogenic systems because of their high effectiveness. They observed that losses such longitudinal conduction through wall, heat in leak from surrounding, flow mal distribution etc. They extended their study to understand quantitative effect of heat in leak and axial conduction parameters on degradation of heat exchanger performance for 300-80k and 80-20k temperature range. Christian [2] has discussed about experimental Investigation on the Effect of Fluid Flow Rate on the Performance of a Parallel Flow Heat Exchanger. Physical characteristics and thermal performance of a real heat exchanger were studied in this work. Also the convective heat transfer coefficient increases with both Reynolds and Nusselt numbers, which increases the overall heat transfer coefficient. Akshay Kumar Magadum [3] has discussed about Review of Experimental analysis of parallel and counter flow heat exchanger. In this paper, we have discussed about various literature review of various paper and we are now going to calculate LMTD by varying flow rate and temperature of hot water and cold fluid. III. JAVA PROGRAM ON PARALLEL FLOW AND COUNTER FLOW HEAT EXCHANGER package heatexchanger; import java.util.*; class Lmtd1 public double qh,qc,t1,t2,l,b,c,a,cph,cpc,mh,mc,thi,tho,tci,tco,u; Lmtd1() Scanner input =new Scanner (System.in); int pc = 0,ans=3; System.out.println (" cp of hot fluid (J/kgk) ="); cph= input.nextdouble(); System.out.println(" cp of cold fluid(j/kgk) ="); cpc= input.nextdouble(); System.out.println(" overall heat transfer coefficient(w/m^2 k)="); u= input.nextdouble(); System.out.println(" mass of hot fluid in kg/sec="); mh= input.nextdouble(); System.out.println(" mass of cold fluid in kg/sec="); mc= input.nextdouble(); System.out.println(" Temperature of hot fluid at inlet Thi in c="); thi= input.nextdouble(); System.out.println(" Temperature of hot fluid at outlet Tho in c="); tho= input.nextdouble(); System.out.println(" Temperature of cold fluid at inlet Tci in c="); tci= input.nextdouble(); System.out.println(" Temperature of cold fluid at outlet Tco in c="); 223

tco= input.nextdouble(); qh=mh*cph*(thi-tho); System.out.println(" heat generated (qh=qc=q) in WATT =" +qh); while(ans==3) System.out.println(" calulation of change in temperature at inlet & outlet as follows"); System.out.println(" 1: for parallel flow press 1,2: for counter flow press 2"); pc=input.nextint(); switch(pc) case 1: t1=thi-tci; System.out.println(" change in inlet temperature t1 in c = "+t1); t2=tho-tco; System.out.println(" change in outlet temperature t2 in c= "+t2); l=(t2-t1); b=math.log(t2/t1); c=(l/b); System.out.println(" log mean temperature difference is in C="+c); A=qh/(u*c); System.out.println(" area of heat exchanger is in m^2 = "+A); case 2: t1=thi-tco; System.out.println(" change in inlet temperature t1 in c= "+t1); t2=tho-tci; System.out.println(" change in outlet temperature t2 in c= "+t2); l=(t2-t1); b=math.log(t2/t1); c=(l/b); System.out.println(" log mean temperature difference is in C ="+c); A=qh/(u*c); System.out.println(" area of heat exchanger is in m^2 = "+A); System.out.println(" if you want to calculate for another type press 3,otherwise press any key "); ans=input.nextint(); if(ans!=3) public class Ntu public static void main(string args[]) double ch,cc,cmin,n,c,cmax,e,d,f,g,h,tho,tco,i; Scanner output =new Scanner (System.in); int nc = 0; int ans=3; Lmtd1 l=new Lmtd1(); System.out.println("cp of hot fluid (J/kgk) ="); System.out.println(l.cph); System.out.println(" cp of cold fluid(j/kgk) ="); System.out.println(l.cpc); System.out.println(" mass of hot fluid in kg/sec="); System.out.println(l.mh); System.out.println(" mass of cold fluid in kg/sec="); System.out.println(l.mc); System.out.println(" Temperature of hot fluid at inlet Thi in C="); System.out.println(l.thi); System.out.println(" Temperature of cold fluid at inlet Tci in C="); System.out.println(l.tci); System.out.println(" Area of heat exchanger in m^2="); System.out.println(l.A); ch=l.mh*l.cph; System.out.println("capacity of hot fluid in W/ C"+ch); cc=l.mc*l.cpc; System.out.println("capacity of cold fluid in W/ C"+cc); if(ch>cc) cmin=cc; cmax=ch; System.out.println(" c min ="+cmin); else cmin=ch; cmax=cc; System.out.println("c min="+cmin); c=cmin/cmax; System.out.println("Overall Capacity Ratio is "+c); n=(l.u*l.a)/cmin; System.out.println("Number Of Transfer Unit (NTU)="+n); while(ans==3) System.out.println(" 1: for parallel flow press 1,2: for counter flow press 2"); nc=output.nextint(); switch(nc) case 1: d=(-n*(1+c)); g=math.pow(2.17,d); f=(1+c); h=(1-g); e=(h/f); System.out.println("effectiveness of parallel flow heat exchanger"+e); tho=l.thi-e*cmin*(l.thi-l.tci)/ch; System.out.println("the outlet temperature of hot fluid in C= "+tho); 224

tco=l.tci+e*cmin*(l.thi-l.tci)/cc; System.out.println("the outlet temperature of cold fluid in C= "+tco); case 2: d=(-n*(1-c)); g=math.pow(2.17,d); h=(1-g); i=(c*g); f=(1-i); e=(h/f); System.out.println("effectiveness of counter flow heat exchanger"+e); tho=l.thi-e*cmin*(l.thi-l.tci)/ch; System.out.println("the outlet temperature of hot fluid in C= "+tho); tco=l.tci+e*cmin*(l.thi-l.tci)/cc; System.out.println("the outlet temperature of cold fluid in C = "+tco); System.out.println(" if you want to calculate for another type press 3,otherwise press any key "); ans=output.nextint(); if(ans!=3) IV. RESULTS 225

160 140 120 100 80 60 40 20 0 AREA PARALLEL FLOW COUNTER FLOW 1 2 Fig.5 Area Required for Counter flow and Parallel Flow Heat Exchanger. 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 EFFECTIVENESS COUNTER FLOW PARALLEL FLOW 1 2 Fig.6 Effectiveness of Parallel and Counter Flow Heat Exchanger In results all input values are given by user so any type of problems can be solved. From graph 5 and 6 it is observed that the area required for counter flow heat exchanger is less as compared to parallel flow heat exchanger. it also observed that the effectiveness of counter flow heat exchanger is greater than parallel flow heat exchanger. V. CONCLUSION At the end of this project we came to conclusion that: 1. The area required for counter flow heat exchanger is less than parallel flow heat exchanger. 2. Because of the counter flow the effectiveness of counter flow heat exchanger is greater than parallel flow heat exchanger inspite of counter flow heat exchanger having less area compared to parallel flow. Because of grater effectiveness of counter flow the efficiency is also greater than parallel flow heat exchanger. 3. Concepts of OOP s helps us to calculate variety of problems of mechanical components like calculation of problems of heat exchanger, design calculation of Pressure vessel, gear etc. 226

REFERENCES [1] Prabhat Gupta,M.D. Atrey. Performance evaluation of counter flow heat exchangers considering the effect of heat in leak and longitudinal conduction for low-temperature applications, Elsevier Science, Cryogenics 40 pp.- 469-474, (2000). [2] Akshay kumar Magadum, Aniket Pawar, Rushikesh Patil, Rohit Phadtare. Mr. T. C. Mestri. Experimental Investigation of Parallel and Counter flow Heat Exchanger. International Journal of Advanced Research in Science, Engineering and Technology Vol. 3, Issue 3, March 2016. [3] A text book of Heat and Mass Transfer, by Yunus A. Cengel. page no. 667-705. [4] A text book of Head First Java, by Kathy sierra and Bert Bates. Page no. 8-14. [5] E.Balagurusamy Programming with Java 3 rd ed. The McGraw-Hill Companies, Inc., 2007. Page no. 1-121 [6] Christian O. Osueke, Anthony O. OnokwaiAdeyinka O. Adeoye. Experimental Investigation on the Effect of Fluid Flow Rate on the Performance of a Parallel Flow Heat Exchanger, International Journal of Innovative Research in Advanced Engineering (IJIRAE) Issue 6,Volume 2,pp. - 2349-2163,( June 2015) 227