Certificate of Conformity Certificate num. Registration date Version Valid until Number Issue date

Similar documents
Certificate of Conformity Certificate num. Registration date Version Valid until Number Issue date

Certificate of Conformity Certificate num. Registration date Version Valid until

Certificate of Conformity Certificate num. Registration date Version Valid until Number Issue date

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

Certificate of Conformity Certificate num. Registration date Version Valid until

AFP-2800/2802 Fire Alarm Panel

Certificate of Conformity Certificate num. Registration date Version Valid until

Fire Alarm Control Panel AFP Installation Manual. New Zealand Edition. Document DOC Rev: E 19/11/2018 ECN:

Fire Alarm Control Panel AFP Installation Manual. Australia Edition. Document DOC Rev: F 19/11/2018 ECN:

Fire Alarm Control Panel AFP Installation Manual. New Zealand Edition. Document DOC /08/2016 Rev: P/N DOC :B

Leaders in Life. Safety. Technology. Product Catalogue New Zealand Edition. Subject to change without notice.

Data/ Specification Sheet

NFS-320. Intelligent Addressable Fire Alarm System

APPLICATION NOTE. Document Type. Application Note. Document Title. Date January Version DS0167/Iss 2. ESP Technical Summary

SECTION FIRE ALARM SYSTEMS

The SCS-8A Smoke Control Module & SCE-8A Smoke Control Expander are used to control and monitor fans connected to an addressable fire panel.

Detection and Control Components

Opal TM AV Devices. Data Sheet. Benefits

FS-1600 Fire Alarm Panel

AFP-300/400 OPERATORS MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

Vigilant MX4428 Fire Alarm System

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

A World of Solutions

Intrinsically Safe Solutions

FireFinder TM AS OPERATORS MANUAL

AutoPulse. AUTOPULSE IQ-318 AGENT RELEASING CONTROL PANEL Data/Specifications

NFS-320(E) Intelligent Addressable Fire Alarm System

NFS-320C. Intelligent Addressable Fire Alarm System

NFS-320C. Intelligent Addressable Fire Alarm System

A World of Solutions in Fire Protection Systems

MX4428. Addressable Fire Alarm System. Features. Advantages & Options

Conventional Fire Alarm Systems. ACCLAIM SERIES 10 Conventional Fire Alarm System ACCLAIM SERIES 10.

EXTINGUISHING AGENT RELEASE MODULE

Data/ Specification Sheet

Fire Alarm Control Panel CFP-16 OPERATION, INSTALLATION & PROGRAMMING MANUAL AUSTRALIAN EDITION. 26/05/2015 Rev D DOC

FIRE ALARM SYSTEM 1.1 GENERAL REQUIREMENTS

Precept Marine Control Panel Application Guide

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

Advance American Products & Services

Input/Output Modules Data Sheet

PSN-1000 & PSN 1000(E) Installation Manual

Opal TM AV Devices. Data Sheet. Benefits

STROBE / SOUNDER INTERFACE

MATERIALS AND PROCUREMENT DEPARTMENT 1900 YONGE STREET PAGE 1 OF 1 TORONTO, ONTARIO M4S 1Z2

ZXSe Range Data Sheet

NOTIFIER TECH TIPS. The Fire Panel displays an isolate that is listed as an Unknown Point or Unnamed Point

NFS-320. Intelligent Addressable Fire Alarm System

POL-200-TS User Manual

OPERATION / INSTALLATION

Installation, Operating and Maintenance Manual

Full Line Catalog and Product Brochures

MEA. NFS-3030 Intelligent. Addressable Fire Alarm System

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Solution F2. Fire Alarm Control Panels one step ahead.

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

Device Compatibility Guide

Technical Data Sheet

The EN54 Part 2 & 4 Fire System

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

NFS Intelligent Addressable Fire Alarm System

NOTIFIER TECH TIP. AFP-3030 VeriFire Tools AUS NFN Gateway V1.0 CH 11/05/16

AFP-300/400 INSTALLATION AND PROGRAMMING MANUAL INTELLIGENT FIRE DETECTION AND ALARM SYSTEM SOFTWARE VERSION 2.2 REVISION AUS 3

NFS-320C. Intelligent Addressable Fire Alarm System. General. Features NFS-320C. Intelligent Fire Alarm Control Panels FLASHSCAN INTELLIGENT FEATURES

FireNET Plus Wiring Instructions

NFS-320. Intelligent Addressable Fire Alarm System. General. Features NFS-320. Intelligent Fire Alarm Control Panels FLASHSCAN INTELLIGENT FEATURES

Touch Screen 1 loop Addressable Fire Alarm Panel

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL


DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

A World of Solutions

VERIFICATION OF FIRE ALARM SYSTEMS

The EN54 Part 2, 4 and 13 Fire System

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

NFS Intelligent Addressable Fire Alarm System

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

AU MX Digital Loop Card Installation Instructions

Quick Selection Guide Analog Addressable Fire Systems

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

Intelligent addressable fire alarm control panel

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

The EN54 Part 2 and 4 Fire System

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

AND ARCHITECT SPECIFICATIONS

Consultant Specification AGILE Wireless Fire Detection System

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

Intelligent Analog/Addressable Fire Alarm/Voice Integration Systems. IntelliKnight TM Series

CAN/ULC-S E1. FIRE ALARM SYSTEM ANNUAL TEST & INSPECTION REPORT (Reference: Clause 5.1.2)

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

Harrington Signal HS-3100/3200 Fire Alarm Control Unit

PRODUCT LISTING DATA SHEET (Active Fire Protection Equipment)

1 INTRODUCTION NOTICE WARNINGS AND CAUTIONS NATIONAL APPROVALS EN54 INFORMATION UNPACKING...

Interface Modules for SENTRI

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

Fire Alarm Control Panel NFS2-640/E. Installation Manual. Document /06/2012 Rev: K1 P/N 52741:K1 ECN

1.3 REFERENCES A. ANSI/NFPA 70 - National Electrical Code. B. ARI Commercial and Industrial Humidifiers.

Transcription:

CSIRO Verification Services Clayton, Victoria, Australia +61 (0)3 9545 2777 http://www.activfire.gov.au/ Page 1 of 5 FireSense, Model AFP-2800, fire indicator panel Issued by Product designation (Refer to the Schedule/enclosures for further specified details) Agent/distributor FireSense Pty Ltd 18-20 Brookhollow Avenue, BAULKHAM HILLS, NSW, AUSTRALIA, 2153 Registrant Honeywell Security and Fire 9 Columbia Way, BAULKHAM HILLS, NSW, AUSTRALIA, 2153 Producer Honeywell Security and Fire 9 Columbia Way, BAULKHAM HILLS, NSW, AUSTRALIA, 2153 Conformance criteria and evaluation The FireSense, Model AFP-2800, fire indicator panel has been evaluated and verified as conforming with the relevant requirements of the following criteria. 1. Australian Standard AS 4428.1-1998, 'Fire detection, warning, control and intercom systems - Control and indicating equipment - Fire'. Limitations/conditions of conformance Limitations/conditions of conformance, where identified on this certificate, are derived from qualifications from evaluation(s) for conformity and/or other related technical documentation. All details with respect to design, assembly and installation instructions and restrictions should be checked against the producer's current technical manual/data sheets and the requirements of the Authority having Jurisdiction. Specified limitations/conditions, determined from the evaluation for conformity, include the following. i. Compatibility of this equipment with new or existing actuating devices should be verified prior to installation. Producer's description The FireSense, Model AFP-2800, fire indicator panel is a microprocessor based fire indicator panel configured as a Class 1 distributed digital/analogue addressable system. The system supports a maximum of two RS485 communication loops driving conventional modules as well as 10 loops of Flashscan or Classic Loop Interface Protocol (CLIP) devices via the LCM/LEM modules. Each LCM or LEM provides one two-wire fault tolerant loop. The manufacturer states that each loop provides a maximum of 159 analogue addressable detectors and 159 control/monitor modules. This certification is issued within the scope of CSIRO Verification Services Rules governing ActivFire Scheme and is valid only for the product(s) as submitted for evaluation and verification of conformity, subject to the following conditions. to details, limitations and requirements, where documented as a schedule/enclosure with this certificate. The Registrant is responsible for their attestation of conformity and ensuring that on-going production complies with the conformance criteria defined in this certificate. This certificate will not be valid if any changes or modifications are made to the product which have not been notified and validated by CSIRO Verification Services. This certificate is subject to periodical re-validation upon verification that all requirements, as determined by the conformity assessment body, continue to be satisfactorily met by the Registrant. This certificate may only be reproduced in its published form, without modification and inclusive of all schedules/enclosures. Any changes, errors or omissions, must be submitted in writing and if necessary or requested, substantiated with relevant evidence. Any representations, such as advertising or other marketing related activities or articles shall reflect the correct contents of this certificate and conform with all relevant trade practices.and consumer protection legislation and regulations. Any terms or conditions of use as applicable to content and documentation as published or accessed through web sites administered by the CSIRO Verification Services. David Whittaker Executive Officer ActivFire Scheme CSIRO Australia, 2018 This certificate remains the property of CSIRO and may be subject to amendment, suspension or withdrawal at any time. The validity and authenticity of this certificate can be verified by the certification register located at http://www.activfire.gov.au

Page 2 of 5 Technical specification The following details are a representative extract of the technical specification for the FireSense, Model AFP-2800, fire indicator panel and may be subject to change. Complete and current details should be determined from the designated producer s technical manual/data sheets. Schedule of properties/characteristics The following schedule is an extract of physical and operational properties/characteristics of the certified/listed equipment. Loops Networking Cabinet colour Schedule of components and/or assemblies 10 x Flashscan or Classic Loop Interface Protocol (CLIP) XLS-NET Charcoal The following is a schedule of validated components and/or assemblies of the certified/listed equipment. Module description Module identification Rev. PCB number CPU board IFS713 C IFS713 Termination board IFS724 A IFS724 Loop/Network Interface module IFS725 (REM/LIM) A PSI (Power supply Interface) NI2012-01 H NI2012-01-1A NI2017-01 C Loop control module (LCM) ELCM-PCB (LCM-320PCA) M 066 Loop expansion module (LEM) ELEM-PCB (LEM-320PCA) L 03451 NCM-W network control module NCM-WCPA H 03423 LCD 2800 LCD - P141-10A Annunciators 32 Red LED ACM-32A 16 x Pushbutton inputs 16 x Red LED ACM-16AT 16 x Yellow LED 8 x 3 Position switches 8 x Red LED 8 x Yellow LED SCS-8 8 x Green LED 1 x Fire Trip (A/C) Reset switch 1 x Fire Trip (A/C) Activated/Latched LED 24 x LED outputs & 25 digital inputs SCS-8L 32 x LED outputs (Open Collector) LDM-32 32 x Relay outputs rated to 1A @ 30Vdc LDM-R32 AFP-2800/2802 Manual DOC-01-010 Power supplies NI-2012 or NI-2017 control board with Models PS243 PBC-70-27 PBC-150-27 SP-320-27 Type Switch mode Switch mode Switch mode Switch mode Input voltage 240 Vac 240 Vac 240 Vac 240 Vac Nominal output voltage 27.8 V 24 Vdc 24 Vdc 24 Vdc rated output current 3 A 2.6A @ 27 Vdc 5.5A @ 27 Vdc 11.7A @ 27 Vdc Circuit current limit 4.6 A - - - Circuit limit fuse rating 3.5 A (Electronic) - - - Battery charger: Charger voltage setting: 27.6 Vdc 27.6 Vdc 27.6 Vdc 27.6 Vdc Circuit current limit: 4.6 A - - - Circuit limit fuse rating: 7.4 A (PTC) - - -

Schedule of compatible or connectable devices/modules on analogue line FZM-1 input conventional zone interface module 159 - FMM-1 input monitor module 159 - FRM-1 output relay module 159 - FMM-101 input mini monitor module 159 - FCM-1 control output module 159 - XP6-C six circuit supervised control module 26 - XP6-MA six zone interface module 26 - XP6-R six relay control module 26 - XP10-M ten input monitor module 15 - Notifier, Model ABS32/W integrated detector base sounder Notifier, Model AIBS32/W (ABS32/W-I) integrated detector base sounder (with isolator) XF2010/R2, Jun 2004 64 n/a XF2493R1, October 2008 Page 3 of 5 Notifier, Model FSM500K, manual call point AWB/R Intelligent wall mounted beacon, red lens AWS32/R Intelligent wall mount sounder AWSB32/R/R Intelligent wall mount sounder, red body and lens FDM-1 Dual switch input module FDMR-1 Dual input/ output module ISO-X Loop (SLC) isolator module M700X Isolator module in 200 series NFX-BF-IVR Addressable strobe base (NFX Series) NFX-BSF-IVR Addressable sounder/strobe base (NFX Series) NFX-BS-IV Addressable sounder base (NFX Series) NFXI-BS-IV Addressable sounder base (NFX Series) NFX-MCP-GLASS Intelligent Manual Call Point (SS India) NFX-WF-RR Addressable strobe (NFX Series) NFX-WSF-RR Addressable sounder/strobe (NFX Series) NFX-WS-R Addressable sounder (NFX Series) NFX-WS-W Addressable sounder (NFX Series) WCP-5A Outdoor manual call point XP5-M 5 way input module XP5-R 5 way relay modules XP5-C 5 way control module These devices/modules have been designated by the Producer as connectable with the certified/listed equipment

Page 4 of 5 Loop protocol: Classic Loop Interface Protocol (CLIP) addressable points on analogue line M502M, input conventional zone interface module 159 - M500M, input monitor module 159 - M500R, output relay module 159 - M501M, input mini monitor module 159 - M500S, control output module 159 - SC-6, six circuit supervised control module 26 - CZ-6, six zone interface module 26 - CR-6, six relay control module 26 - IM-10, ten input monitor module 15 - AS 4428.1 1998 XL1960.04 XF2010/R2, Jun 2004 AS 4428.1 1998 XL1960.04 Single Line Circuit (SLC) actuating devices: Actuating or integrated device addressable points on analogue line Notifier, FSI-751, smoke ionization 159 40* Notifier, FSP-751, smoke photoelectric 159 40* Notifier, FAPT-751 Acclimate, Multi-sensor 159 40* Notifier, FST-751, heat type B 159 40* Notifier, FST-751R, heat type A 159 40* The above detectors with the System Sensor B501 base. Notifier, FSI-851AUS, smoke ionization 159 40* Notifier, FSP-851AUS, smoke photoelectric 159 40* Notifier, FAPT-851AUS, Acclimate, multi-sensor 159 40* Notifier, FST-851AUS, heat type B 159 40* Notifier, FST-851RAUS, heat type A 159 40* Notifier, FSL-751 VIEW, smoke photoelectric 159 40* The above detectors with the System Sensor B501 base Notifier, Model ABS32/W integrated detector base sounder 64 n/a Notifier, Model AIBS32/W (ABS32/W-I) integrated detector base sounder (with isolator) 64 n/a and xla-13, 22-Dec-2006 XF2493R1, October 2008 The above detector base sounders with the Notifier LPBW (mounting/wiring base) and one of the following actuating devices 1. Notifier, FSI-851AUS, smoke ionisation 4. Notifier, FST-851AUS, heat type B 2. Notifier, FSP-851AUS, smoke photoelectric 5. Notifier, FST-851RAUS, heat type A 3. Notifier, FAPT-851AUS Acclimate, multi-sensor 6. Notifier, FSL-751 VIEW, smoke photoelectric Notifier, SDX-751CTEM 99 40* XF2329/R1, July 2007 Notifier, FSC-851AUS 159 40* The above detectors with the Notifier B501 base XF2432/R1, November 2009 Notifier, FSB-200 159 40* Notifier, FSB-200S 159 40* XF2069/R1, August 2006 * number of detectors per AZF/AZC allowed by code. number of devices allowed per AZM-8, PAZM-8 & internal AZFs EOL 4K7-24 V Hochiki, DCA-B-60R Mk V, heat type A 40* Hochiki, DCA-B-90R Mk I, heat type C 40* Hochiki, DCC-A, heat type A 40* Hochiki, DCC-C, heat type C 40* The above detectors with Hochiki YBF-RL/4AH4M Base Hochiki, DCD-A, heat type A 40* XF1822/R1, July 2002 AS 4428.0-1997, Appendix E

Page 5 of 5 number of devices allowed per AZM-8, PAZM-8 & internal AZFs EOL 4K7-24 V Hochiki, DCD-C, heat type C 40* The above detectors with Hochiki YBN-R/4A or YBO-R/4A Bases Hochiki, DFE-60B, heat type B 40* Hochiki, DFE-90D, heat type D 40* The above detectors with Hochiki YBF-RL/4AH4M Base Hochiki, DFG-60BLKJ, heat type B (Cool Room) 40* Hochiki, DFJ-60B, heat type B 40* Hochiki, DFJ-90D, heat type D 40* The above detectors with Hochiki YBN-R/4A or YBO-R/4A Bases Hochiki, SIH-AM, smoke ionisation with Hochiki YBF-RL/4AH4M Base Hochiki, SIJ-AS, smoke ionisation with Hochiki YBN-R/4A or YBO-R/4A Bases Hochiki, SLK-A, smoke photoelectric with Hochiki YBF-RL/4AH4M Base Hochiki, SLR-AS, smoke ionisation with Hochiki YBN-R/4A or YBO-R/4A Base 40* * number of detectors per AZF/AZC allowed by code. Single Line Circuit (SLC) actuating devices: B524IEFT(W) Short circuit isolator base FDX-851AUS Intelligent thermal sensor FDX-851RAUS Intelligent thermal sensor FSD-751PL Innovair Low-Flow DSU FSL-751 View high sensitivity laser sensor FST-851R-WP Intelligent sealed thermal sensor FST-851-WP Intelligent sealed thermal sensor IDX-751 Intrinsically safe addressable photo-electric detector LPX-751AUS(L) View high sensitivity laser sensor NFX-TFI78-IV Intelligent High Temp Heat SDX-751CTEM SMART 4 SDX-851 Intelligent photo sensor SLC-IM Modbus interface module System Sensor, 2151BAUS, smoke, photoelectric System Sensor, 51A51, type A heat System Sensor, 51B51, type C heat System Sensor, 51C51, type C heat System Sensor, 51D51, type C heat The above System Sensor detectors with System Sensor P/N B401 base System Sensor, 885WP-B, type B heat Surface mounting; provided with "flying" leads for electrical connection These devices/modules have been designated by the Producer as connectable with the certified/listed equipment Notifier, FDX-751BAUS, type B heat Notifier, FDX-751RBAUS, type A heat The above detectors with System Sensor/Notifier, B501 base Notifier, SDX-751AUS smoke The above detectors with Notifier, Model B501, System Sensor, B501 or B501BH bases Notifier Innovair, Model FSD-751P, duct sampling unit Notifier, Model FSM500K, manual call point